• Title/Summary/Keyword: analysis system

Search Result 69,940, Processing Time 0.075 seconds

Feasibility Analysis of STATCOM Application for Jeiu-Haenam HVDC System (제주-해남 HVDC 시스템에 STASTCOM 적용 타당성 분석)

  • Baek Seung-Taek;Choo Won-Gvo;Han Byung-Moon;Jang Gil-Soo
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.8
    • /
    • pp.401-409
    • /
    • 2005
  • This paper describes a feasibility analysis result of STATCOM application for the Jeju-Haenam HVDC system. The Jeju-Haenam HVDC system is one of the typical HVDC system interconnected with the low short-circuit-ratio AC system, which is vulnerable to the commutation failure due to the AC voltage variation. STATCOM has been considered as an effective reactive-power compensator to increase short-circuit-ratio of the interconnected AC system. In this study, a simulation model of Jeju-Hacnam HVDC system with STATCOM was developed using PSCAD/EMTDC. The developed simulation model was utilized to analyze the dynamic performance analysis of Jeju-Haenam HVDC system with STATCOM. The analysis results show that STATCOM can improve the dynamic performance of Jeju-Haenam HVDC system, such as load-change recovery performance and fault recovery performance.

Economic Analysis of Energy Storage System for power system in Jeju (제주지역 전력계통에 설치되는 에너지 저장장치의 경제성 분석)

  • Choi, Joon-Young;Lee, Jong-Hyun;Ahn, Jong-Wook;Ko, Won-Suk;Hong, Jun-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.8
    • /
    • pp.104-109
    • /
    • 2009
  • In this paper, economic analysis of Energy Storage System for power system is performed. Economic analysis is performed to show the benefits of Energy Storage System. Results illustrate the advantages of Energy Storage System not only acting as an alternative generation resource but also giving a better reliability and stability in power system.

Feasibility Analysis of STATCOM Application for Jeju-Haenam HVDC System (제주-해남 HVDC 시스템에 STATCOM 적용 타당성 분석)

  • Baek, Seung-Taek;Han, Byung-Moon;Jang, Gil-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.60-62
    • /
    • 2005
  • This paper describes a feasibility analysis result of STATCOM application for the Jeiu-Haenam HVDC system. The Jeju-Haenam HVDC system is one of the typical HVDC system interconnected with the low short-circuit-ratio AC system, which is vulnerable to the commutation failure due to the AC voltage variation. STATCOM has been considered as an effective reactive-power compensator to increase short-circuit-ratio of the interconnected AC system. In this study, a simulation model of Jeju-Haenam HVDC system with STATCOM was developed using PSCAD/EMTDC. The developed simulation model was utilized to analyze the dynamic performance analysis of Jeju-Haenam HVDC system with STATCOM. The analysis results show that STATCOM can improve the dynamic performance of Jeju-Haenam HVDC system, such as load-change recovery performance and fault recovery performance.

  • PDF

Parametric Design on Bellows of Piping System Using Fuzzy Knowledge Processing

  • Lee Yang-Chang;Lee Joon-Seong;Choi Yoon-Jong
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.6 no.2
    • /
    • pp.144-149
    • /
    • 2006
  • This paper describes a novel automated analysis system for bellows of piping system. An automatic finite element (FE) mesh generation technique, which is based on the fuzzy theory and computational geometry technique, is incorporated into the system, together with one of commercial FE analysis codes and one of commercial solid modelers. In this system, a geometric model, i.e. an analysis model, is first defined using a commercial solid modelers for 3-D shell structures. Node is generated if its distance from existing node points is similar to the node spacing function at the point. The node spacing function is well controlled by the fuzzy knowledge processing. The Delaunay triangulation technique is introduced as a basic tool for element generation. The triangular elements are converted to quadrilateral elements. Practical performances of the present system are demonstrated through several analysis for bellows of piping system.

Parametric Study on Bellows of Piping System Using Fuzzy Theory

  • Lee Yang-Chang;Lee Joon-Seong
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.6 no.1
    • /
    • pp.58-63
    • /
    • 2006
  • This paper describes a novel automated analysis system for bellows of piping system. An automatic finite element (FE) mesh generation technique, which is based on the fuzzy theory and computational geometry technique, is incorporated into the system, together with one of commercial FE analysis codes and one of commercial solid modelers. In this system, a geometric model, i.e. an analysis model, is first defined using a commercial solid modelers for 3-D shell structures. Node is generated if its distance from existing node points is similar to the node spacing function at the point. The node spacing function is well controlled by the fuzzy knowledge processing. The Delaunay triangulation technique is introduced as a basic tool for element generation. The triangular elements are converted to quadrilateral elements. Practical performances of the present system are demonstrated through several analysis for bellows of piping system.

Development of Analysis Model for Metro Railway Power System Using PSCAD/EMTDC (PSCAD/EMTDC를 이용한 전기철도 전력공급시스템 해석모델개발)

  • Jang, Gil-Soo;Cha, Jun-Min
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.11
    • /
    • pp.463-467
    • /
    • 2006
  • A direct current electric power system is one of the most important power source in a metro railway system. As railway system is growing up today, the importance of DC electric power system is emphasized. The study for systemization and standardization of design and operation technique in DC electric power system is undergoing nowadays. For these studies, the development of standard analysis model for metro railway electric power system is required. In this paper, a standard analysis model for metro railway electric power system which is using PSCAD/EMTDC program is proposed. The proposed model is explained and the validity is shown by using the case studies.

A Study on the Lateral Dynamics of a Train using Equivalent System (등가계를 이용한 열차의 횡방향 거동 연구)

  • 박동일;임진수
    • Proceedings of the KSR Conference
    • /
    • 1998.11a
    • /
    • pp.345-352
    • /
    • 1998
  • The dynamic analysis of a train system has tended to analyze one vehicle or subsystem of that rather than to analyze entire vehicles. But, the speeding and lightening of a train requires more accurate analysis. Thus, the analysis of entire vehicles is required but it spends much time. Therefore, it is needed to find out the new analytic method which is more accurate and efficient. This paper suggests a new method for analyzing a multi-vehicle system more efficiently, using‘mechanical impedance’At first, get the impedance of vehicles which influence the dynamics of the object car, through analyzing the dynamics of a vehicle. ‘Equivalent system’, a simple mechanical system, of which the impedance is similar to that ,is proposed. Then, the equivalent system was applied to a vehicle and it showed that the equivalent system works like a real vehicle system. Finally, we tried non-linear analysis of a vehicle to which the equivalent system is applied.

  • PDF

Torsional Vibration Analysis of a Multi-Stage Reduction Gear System (다단 감속치차계의 비틀림진동 해석)

  • 이동환;김영철;최상규;이안성
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.10a
    • /
    • pp.307-312
    • /
    • 1996
  • A torsional vibration analysis of a multi-stage reduction gear box connected to a gas turbine system is presented. For a free vibration analysis the Modified Hibner Branch Method, so called "Blank Matrix Method", and the .lambda.-Matrix Method are used in the modeling and the eigenvalue solution, respectively. Also, a short circuit forced analysis of the system is performed, utilizing the energy method modeling. It is shown that the results of the free vibration analysis have the same tendency as those of the short circuit analysis. analysis.

  • PDF

A Study on the Evaluation of the Impact of Power System according to the Connection of Renewable Energy (신재생 전원 계통 접속에 따른 전력계통 영향 평가에 관한 연구)

  • Park, Seoung-Jun;Cho, Yun-Sung;Hur, Jin;Park, Sang Ho;Yoon, Gi Gab
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.733-737
    • /
    • 2018
  • In this paper, we describe the effects on the power system by adding renewable generator. In order to examine the stability of the system, the system analysis was performed using the PSS/E software. We confirmed whether occur the line overload of system through the load flow analysis and contingency analysis. and confirmed whether exceed of fault current using the fault current analysis. Dynamic stability of the system is analyzed through dynamic simulation. The analysis of the system according to the addition of the renewable generator was carried out according to the power system reliability and electricity quality maintenance standard.

A Study on Performance-based Seismic Design Method of Fire Extinguishing Pipe System (소화설비 배관의 성능위주 내진설계 방법에 관한 연구)

  • Lee, Jae-Ou;Kim, Hong-Kyung;Cho, Soon-Bong
    • Fire Science and Engineering
    • /
    • v.31 no.4
    • /
    • pp.86-94
    • /
    • 2017
  • In the present study, a Cook Book method and a Static System Analysis method were compared with each other on the basis of a seismic design criteria of fire-fighting facilities and analyzed. The Cook Book method is analyzed by dividing a pipeline in each same section. In this method, a stress analysis is not possible except for the section analyzed in such a way that a brace is designed according to the weight of pipe, water and pipe fitting. To the contrary, in case of the Static System Analysis method, the stress analysis for the whole pipeline can be performed because the whole pipeline is regarded as a single structure. For the fatal stress values locally generated, it is necessary to actively perform a pipeline analysis by installing a device capable of locally relieving the stress of the pipeline. In Korea, only the Cook Book method is provided as the seismic design criteria of fire-fighting facilities, which causes many problems with diversification of seismic design. Thus, it is necessary to apply the seismic design method of the pipeline by using various kinds of engineered Static System Analysis methods.