• Title/Summary/Keyword: an eel farm

Search Result 7, Processing Time 0.02 seconds

Status and Characteristics of JEECV (Japanese Eel Endothelial Cell-infecting Virus) and AnHV (Anguillid Herpesvirus 1) Infections in Domestic Farmed Eels Anguilla japonica, Anguilla bicolor and Anguilla marmorata (국내 양식 뱀장어(Anguilla japonica, Anguilla bicolor and Anguilla marmorata)의 JEECV (Japanese Eel Endothelial Cell-infecting Virus)와 AnHV (Anguillid Herpesvirus 1) 감염 현황 및 특성 연구)

  • Jang, Mun Hee;Lee, Nam-Sil;Cho, Miyoung;Song, Jun-Young
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.54 no.5
    • /
    • pp.668-675
    • /
    • 2021
  • The infection status of domestic farmed eels Anguilla japonica, Anguilla bicolor and Anguilla marmorata with Japanese eel endothelial cell-infecting virus (JEECV) and anguillid herpesvirus 1 (AnHV) was examined at the major eel farming areas in Korea. These viruses were detected in all areas examined, regardless of the eel species or age. Any farm with a history of viral infection in adult fish confirmed the infection to be transmitted to stocked fry within 3 to 5 months. It is proposed that both viruses are horizontally transmitted within a given farm. The primary symptoms and histopathological lesions produced by the two viral infections are similar, making it difficult to distinguish the two diseases through clinical symptoms. Both viruses displayed 100% detection in the gills, suggesting that the gills are an optimal tissue for JEECV and AnHV monitoring. This study concluded that JEECV and AnHV were prevalent on eel farms across the country and caused very high mortality when the two viruses co-infected fry. Additional studies, including experimental infections, are needed to clearly understand the pathogenicity of each virus and the risk of co-infection.

Study of Blast Ground Vibration & Noise Measurements In-situ and Effect Analysis for Numerical Analysis, Rational Blasting Design at an Eel Farm (양만장의 발파 진동소음 현장측정과 수치해석을 통한 영향검토 및 합리적인 발파설계 연구)

  • Lee Song;Kim Sung-Ku;Rhee Yong-Ho
    • Tunnel and Underground Space
    • /
    • v.16 no.2 s.61
    • /
    • pp.179-188
    • /
    • 2006
  • The vibration or/and noise generated by blast operations might cause not only structural damage to properties but mentally also to humans and animals. For that reason, maximum permitted vibration and noise levels are set by sensitivities of structures and they are used for the management of blast vibration. It is known that the fish lived in water are more sensitive to vibration than land animals, and thus the adverse impact of the blasting on fish farms should be very concerned. This study investigated the vibration and noise levels at a large eel farm located some 840 meters of the blasting site through the large real-scale experiments of blastings, prior to conducting the actual blasting. As a result, it was found that the noise met the requirement to be within maximum permitted level, while the ground vibration exceeded the permitted vibration. Accordingly, the impact of the excess vibration was investigated by an existing empirical method and verified by a new three dimensional numerical analysis. In this study, such an inspection process was briefly described, and a method was suggested for the examination of possible adverse effects from blasting on vibration-sensitive structures like the eel farm. The study also introduced a design method that controls the blast effects - ground vibration and noise.

An Evaluation of Major Nutrients of Four Farmed Freshwater Eel Species (Anguilla japonica, A. rostrata, A. bicolor pacifica and A. marmorata) (국내양식 민물장어 4 종(Anguilla japonica, A. rostrata, A. bicolor pacifica 및 A. marmorata)의 주요 영양성분의 평가)

  • Ahn, Jun Cheul;Chong, Won-Seog;Na, Jin Ho;Yun, Hyoeng Bok;Shin, Kyung Jae;Lee, Kyeong Woo;Park, Jun Taek
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.48 no.1
    • /
    • pp.44-50
    • /
    • 2015
  • The basic and main nutritive ingredients of two temperature (Anguilla japonica and A. rostrata) and two tropical (A. bicolor pacifica and A. marmorata) fresh water eel species that are farmed domestically were evaluated. With exception of A. rostrata, eels cultured at the same farm were used for analysis. The contents of crude protein were in the order A. marmorata (17.7%)>A. rostrata (17.5%)>A. bicolor pacifica (17.4%)>A. japonica (15.8%) and the contents of crude lipids were A. japonica (21.5%)>A. rostrata (15.4%)>A. bicolor pacifica (10.5%)>A. marmorata (8.9%). These values differed significantly even among the three species of eel farmed under identical culture conditions. In comparison, all four species of eel showed similar pattern in overall amino acid composition, although slight differences in the compositions of some amino acids were observed. The fatty acid compositions of muscle tissues were notably different among four species of eel, especially between the tropical and temperature eels. In a taste-test of the meat of the four eel species, which considered taste, flavor and texture, the overall preference was in the order A. japonica, A. marmorata, A. bicolor pacifica and A. rostrata.

Flicker Mitigation in a Wind Farm by Controlling a Permanent Magnet Synchronous Generator (영구자석형 동기발전기를 이용한 풍력단지의 플리커 저감)

  • Hoan, Pham Van;Kim, Dae-Hyun;Ahn, Jin-Hong;Kim, Eel-Hwan;Oh, Seong-Bo;Kim, Ho-Chan;Kim, Se-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.12
    • /
    • pp.1163-1168
    • /
    • 2009
  • The power quality of wind energy becomes more and more important in connecting wind-farms to the grid, especially weak grid. This paper presents the simulation of a wind farm of a permanent magnet synchronous generator (PMSG) and a doubly fed induction generator (DFIG). Flicker mitigation is performed by using PMSG as a static synchronous compensator (STATCOM) to regulate the voltage at the point of common coupling (PCC). A benefit of the measure is that integrating two function of to control the active power flow and to reduce the voltage flicker in a wind farm. Simulation results show that controlling PMSG is an effective and economic measure in reducing the flicker during continuous operation of grid connected wind turbines regardless of short circuit capacity ratio, turbulence intensity and grid impedance angle.

Monitoring of Japanese eel (Anguilla japonica) diseases from 2021 to 2023: significance of Japanese Eel Endothelial Cells-infecting Virus (JEECV) and Edwardsiella anguillarum (2021년부터 2023년까지 뱀장어(Anguilla japonica) 질병 모니터링: 혈관내피세포감염바이러스(JEECV)와 Edwardsiella anguillarum의 중요성)

  • Hyeon-Kyeong Kim;Mun-Hee Jang;Sung-Ju Jung
    • Journal of fish pathology
    • /
    • v.36 no.2
    • /
    • pp.239-250
    • /
    • 2023
  • Disease monitoring was conducted to investigate the recent disease occurrence in Japanese eels (Anguilla japonica). Between May 2021 and March 2022, an investigation was conducted on eels from seven farms experiencing mortality. JEECV (Japanese eel endothelial cells-infecting virus) was detected in all examined farms, each exhibiting co-infections with 1 or 2 bacteria, including Edwardsiella anguillarum, E. piscisida, Aeromonas sp., Citrobacter freundii, Lactococcus garviae, or Vibrio sp. From March 2022 to October 2023, monthly periodic inspections were carried out at a farm in Yeonggwang, Jeollanam-do, for a total of 22 times. JEECV was detected in 10 out of 22 times, even when mortality was not recorded. Bacteria such as E. anguillarum, C. freundii, Aeromonas sp., and Vibrio sp. were isolated, but consistent clinical signs of liver abscess and hemorrhagic lesions were only recognized in fish infected with E. anguillarum. Other bacteria were often isolated from apparently healthy fish. In conclusion, mortality in eel farms frequently occurs due to co-infections of JEECV with bacteria rather than JEECV alone. Therefore, to reduce eel mortality, it is crucial to decrease co-infections, with a particular emphasis of JEECV and E. anguillarum.

Effect of Fish Farm Fecal Solid Diets on the Growth and Energy Budget of Juvenile Sea Cucumber Apostichopus japonicus (육상어류양식장 고형오물을 공급한 해삼(Apostichopus japonicus)의 성장과 에너지 수지)

  • Jin, Feng;Jeong, U-Cheol;Choi, Jong- Kuk;Md, Anisuzzaman;Kim, Kyoung-Duck;Choi, Byeong-Dae;Kang, Seok-Joong
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.49 no.2
    • /
    • pp.168-175
    • /
    • 2016
  • We conducted a 90-day feeding experiment to evaluate the growth and energy budget of the sea cucumber Apostichopus japonicus. Sea cucumbers with a mean initial wet body weight of 3.03±0.06 g were fed one of the following three diets: an eel fecal solid diet, rainbow trout fecal solid diet, or a commercial diet at a water temperature of 17±1℃ and salinity of 32±1 psu. The results suggested that the diets affected the final body weight, specific growth rate (SGR), food ingestion, feces production ratio, and hence the growth and energy budget of the sea cucumbers. Sea cucumbers fed the eel and rainbow trout fecal solid diets showed poorer energy absorption, assimilation, and growth than those fed the commercial diet. The sea cucumbers fed the commercial diet had a significantly higher SGR and proportion of energy used for growth than those fed the other two diets. Sea cucumbers fed the rainbow trout fecal solid diet showed a comparatively higher ingestion rate and feces production ratio than those fed the commercial diet. The eel and rainbow trout fecal solid diets, therefore, were not suitable for sea cucumbers in intensive cultivation. Our findings will facilitate further development of more appropriate diets for culture of sea cucumber.

Analysis of fault current in offshore wind farm ccording to the grid connection method (해상풍력 발전단지의 전력망 연계방식에 따른 고장전류 분석)

  • Ahn, Jin-Hong;Kim, Eel-Hwan
    • Journal of IKEEE
    • /
    • v.24 no.3
    • /
    • pp.691-698
    • /
    • 2020
  • The installation cost or the magnitude of the fault current varies depending on the grid connection method of the offshore wind farm. Therefore, there is a need for an efficient power grid connection method considering the capacity and location of the complex. In particular, most power cables in offshore wind farms use 3-core considering cost and efficiency. In the event of a failure such as a short circuit, the entire cable must be replaced, which can lead to significant losses in terms of cost, considering repair costs and turbine downtime. Therefore, in this paper, a radial, ring, and molding method is introduced into a 100 MW wind farm to be installed at Jeju offshore, and a three-phase short circuit failure is performed using a PSCAD/EMTDC program to perform computer analysis. I would like to propose a suitable power grid connection method.