• Title/Summary/Keyword: an apartment house

Search Result 393, Processing Time 0.025 seconds

The Organization of Domestic Space in Belgium - With Special Reference to Flemish Area - (벨지움 주택의 평면구성에 대한 연구)

  • 김미희
    • Journal of the Korean housing association
    • /
    • v.7 no.1
    • /
    • pp.15-24
    • /
    • 1996
  • This study attempts to explore the organization of domestic space in Belgium and then to compare them with those found in Korea. Data were collected by questionnaires mailed to 110 staff members, both academic an dadministrative, working at Vrije Universiteit Brussel in Belgium.The major findings of the study can be summarized as fllows: First, the most common pattern of Belgian LDK(living-room dining-room and kichen) layout is the LD type, which separates K from L and D by wall or door while linking L and D to each other. On the other hand, a large portions of Korean LDK layout is the DK type , which seperates L from D and H, but D and K are interconnected. As expected, the bigger the size of floor space, the more likely L-D-K type is to be, which places L, D, and f, separate each other. And the smaller the sire the more probable the DK type and/or the one room type would be, where L, D and K are merged into one room. Second, the enterance of domestic space in Belgium is normally found adjacent to public space. The Belgian entrance often forms a space independent from other parts of the house, or a space that leads directly to garage. These two patterns are rarely found in Korea. Third, Belgians tend to locate Kichen in the front of the house when they design apartment units, Whereas it is not the case in Korea where it is located in the rear.

  • PDF

Older People's Innovativeness toward Technologies and Demand of Home Automation System (노년층의 기술수용성향과 홈오토메이션 시스템에 대한 요구도)

  • Kwon, Oh-Jung
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2005.11a
    • /
    • pp.67-72
    • /
    • 2005
  • The purpose of this study was to determine the factors which affect older people's innovativeness toward technologies and factors which affect their demand of home automation system. The study collected data from 289 persons who are 50 years and older with experience living in an apartment currently or past. Innovativeness toward technologies of respondents were low level and the significant factors which affect their innovativeness were age, education, employment, marital status, current housing types, health status of self and spouse, consideration of home automation system for a newly-moved house. Education, employment types, consideration of home automation system for a newly-moved house, and plan for moving were the major factors which affect demand of home automation system. Also, older people's innovativeness toward technologies was the most important factors which affect demand of home automation system. Th results of this study explained that high technologies which are adopted in residential environment should be considered target consumers' abilities and attitudes for acceptance toward new ideas. Especially, for older consumers, various ideas to expand their understanding of new technologies should be developed and the positive effect of technologies to increase the qualify of their later life should be educated.

  • PDF

Green Building Design Strategies for Multiplex Housing

  • Park, Won Ho;Ahn, Yong Han;Choi, Young-Oh
    • KIEAE Journal
    • /
    • v.16 no.4
    • /
    • pp.21-30
    • /
    • 2016
  • Purpose: Energy saving in the built facilities is getting important due to energy crisis. The Korea government has been implemented several energy and green building policies and practices. The both of government and industry also developed green building strategies ant technologies to reduce energy consumption and carbon emission. The purpose of this research is to identify applicable green building strategies and technologies for that can be cost effective and applicable to a multiplex house. Method: This research identified appropriate green building strategies from analysing green building strategies from G-SEED certified apartment projects and popular green building strategies. This study also adopted a survey research method to find out the applicable green building strategies for a multiplex housing. In addition, this research also conduct cost estimating to identify initial cost premium of green building strategies. Results: The research outcomes in this study guide a building owner to know about initial cost premiums of green building strategies and technologies and an architect and contractor to identify appropriate and cost effective green building strategies that can be applicable to a multiplex house.

Analysis of Factors for Improvement of Economic Feasibility of Construction Cost to Spread Application of OSC Construction Method for Apartment Housing (공동주택 OSC공법 적용 확산을 위한 공사비 분야 경제성 개선 요인 분석 - PC 부재 설계, 제작, 운송, 시공을 중심으로 -)

  • Yun, WonGun;Shin, Eun-Young;Kang, Tai-Kyung
    • Korean Journal of Construction Engineering and Management
    • /
    • v.22 no.6
    • /
    • pp.55-63
    • /
    • 2021
  • Recently, as the problem of the traditional on-site labor-intensive construction production method has been raised due to changes in construction work labor and site conditions, the OSC method is gradually spreading as an alternative to this. Even in apartment houses, the application of the PC method is expanding centered on the underground parking lot, but the high cost structure is a problem compared to the conventional formwork method. In this study, factors affecting the calculation of construction cost in the economic evaluation, which are the core of determining the construction method for apartment buildings, are derived through domestic and foreign literature review and expert advice, the importance was analyzed through an opinion survey targeting industry experts. The measures to reduce construction cost were mainly derived from the improvement of the design and manufacturing process. It is expected that the factors affecting the construction cost and improvement measures of the PC method derived from this study will serve as a direction for technology development to spread the application of the PC method for apartment houses in the future.

Dispute Issues and Improvement of Inter-layer Joints in Apartment Houses (공동주택 층간이음부의 분쟁 쟁점 및 개선 방안)

  • Bang, Hong-Soon;Bae, In-ho;Kim, Ok-Kyue
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.2
    • /
    • pp.129-139
    • /
    • 2021
  • Recent rise in the supply rate of new public apartment houses leads to an increasement in disputes regarding the construction quality of the apartments between the residents and the construction companies. According to the dispute cases filed for claiming the collective defect repair fees, inter-layer concrete joints turned out to be the most frequently disputed item. For this reason, this study selects the inter-layer concrete joints to further analyze the primary causes and details of each dispute case. From the results of this study, three primary causes of the disputes are found, which are 1) the absence of standard specifications for construction quality control and management after construction; 2) the absence of established standards for repair when construction defects are found; and 3) the fact that the court grants generous compensation for disputes concerning the apartment houses. In order to prevent construction defects in inter-layer concrete joints, this study provides three suggestions including 1) the current standard specifications for inter-layer concrete joints should be further specified by the Ministry of Land, Infrastructure and Transport; 2) a construction defect should be judged according to the compliance to the standard specifications; and 3) a clear and institutional protocol needs to be established for defect repair in cases that new public apartment houses have been judged to have defects.

The Change of Heating and Cooling Load according to the Thermal Insulation Performance of Window for an Apartment House (창호의 단열성능에 따른 공동주택 냉난방 부하량 변화)

  • Song, Su-Bin;Kim, Young-Tag;Yoon, Seong-Hwan
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.853-856
    • /
    • 2008
  • Windows have an great effect on annual building load because windows are the weakest parts of building envelope thermally. To reduce the consumption of building energy, the thermal performance of window has to be improved in first place. Therefore this research aims to make a quantitative analysis of the heating and cooling load according to the window thermal performance using the heat load simulation program. As a result of the simulation, annual heat load is down 38% according to the decrease of U-value of window, 1.00 W/$m^2K$. and annual heat load is up 10% according to the decrease of shading coefficient, 0.20. The annual load of the window with Low-E glass is 15% lower than the window with pair glass.

  • PDF

A Study on the Planning for PC Use Space in Residences - Focus on the Unit Plan of Apartments According to the Size - (주거 내 PC 사용공간 계획에 관한 연구)

  • Jeong, Byeol-Ah;Kim, Bong-Ae
    • Journal of the Korean housing association
    • /
    • v.18 no.3
    • /
    • pp.51-61
    • /
    • 2007
  • This study is aimed to provide a guide for PC use space in apartment. To achieve this, a design about PC use space which was considered adequate location, area, form was suggested. As methods of the study, survey research method and case study. The survey was taken by five hundred-eighty-nine people who used PCs in apartment from May 2005 to July 2005 in JeJu Special Self-governing Province for an analysis of data. The results of the survey were showed PC use space situation and furnitures layout patterns. The case was classified by unit plans of size, and it showed design example of PC use space. In types of $61{\sim}69$ square meters ($m^2$), PC use space was located in dead-space in the residence with minimum scale, because of $61{\sim}69$ square meters types are smaller than the other types. In types $100{\sim}129$ square meters, PC use space which was divided with a partition panel was located in the livingroom expanding the room space to the balcony. In types of 130 square meters, PC use space was located in the room of sons or daughters which was arranged with other furniture. The adequate area of PC use space is $1.4{\sim}2.2$ square meters, and it should take into account furniture size and human active sphere. And PC use space of form should consider traffic line, personal space and privacy. Besides it is required of ergonomic design in chair, table in its scale. And it is necessary development of systematic furniture for PC use space.

A Study on the Planning for PC Use Space in Residences;Focus on the Unit Plan of Apartments According to the Size (주거 내 PC 사용공간 계획에 관한 연구;평형대별 아파트 내부평면을 중심으로)

  • Jeong, Byeol-Ah;Kim, Bong-Ae
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2006.11a
    • /
    • pp.86-91
    • /
    • 2006
  • This study is aimed to provide a guide for PC use space in apartment. To achieve this, a design about PC use space which was considered adequate location, area, form was suggested. As methods of the study, survey research method and case study. The survey was taken by five hundred-eighty-nine people who used PCs in apartment from May 2005 to July 2005 in Je-Ju province for an analysis of data. The results of the survey were showed PC use space situation and furnitures layout patterns. The case was classified by unit plans of size, and it showed design example of PC use space. In case of the 20s pyeong(about 3.30 square meters) type, PC use space was located in dead-space in the residence with minimum scale, because of 20s pyeong types are smaller than the other types. In case of the 30s pyeong type, PC use space which was divided with a partition panel was located in the livingroom expanding the room space to the balcony. In case of the 40s pyeong type, PC use space was located in the room of sons or daughters which was arranged with other furniture. The adequate area of PC use space is 1.4$^{\sim}$2.2 square meters, and it should take into account furniture size and human active sphere. And PC use space of form should consider traffic line, personal space and privacy. Besides it is required of ergonomic design in chair, table in its scale. And it is necessary development of systematic furniture for PC use space.

  • PDF

A Design of Ubiquitous Home Automation System for Domestic 35-Pyung Apartment Based on USN Environment (USN환경을 도입한 국내 35평 아파트의 유비쿼터스 홈오토메이션 시스템의 설계)

  • Shin Kyung-Chul;Oh Yong-Sun
    • Journal of Game and Entertainment
    • /
    • v.2 no.1
    • /
    • pp.78-86
    • /
    • 2006
  • In this paper, we design a ubiquitous home automation system for Korean domestic 33-Pyung Apartment based on USN environment. The core of this home automation system is to give Home the 'Intelligence' so that the house can analyze and memorize the occurrences and react spontaneously on the user requirements by means of the World Model, USN, and LBS etc. Ultimately, the resident of this intelligent home might access all of these ubiquitous environments without any feelings about the equipments and peripherals. The methods of user identification, image recognition, and the ultrasonic sensors locations have been applied to Korean domestic 35-Pyung Apartment, but they will be easily generalized to be an extended model because of the flexibility of the World Model. which are confirmed by the imaginary scenario presented at the end of the main left.

  • PDF

A Study on the Change of Indoor Thermal Environment According to the location of Blinds (블라인드 설치 위치에 따른 실내열환경 변화에 관한 연구)

  • Hwang, Deuk-Soo;Lee, Kyung-Hee
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.5
    • /
    • pp.113-118
    • /
    • 2011
  • In order to prevent incoming solar radiation, it is necessary to study about blinds' blocking out effects of heat that are installed at the balcony at an apartment house. To figure out the heating effects from the windows, a study for indoor thermal environment according to the location of blinds is also needed. In order to find out the changes of indoor thermal environment, we'll compare models of a house building with or without Venetian blinds: one place has an extended living room removing a balcony and another one has a normal balcony. The result is as follows. Without blinds, the place with an extended living room has benefits for saving heat compare to the place with a normal balcony. It's because the warm air heated by the incoming solar radiation moves into the living room through convection current and radiation which causes an increase of the indoor temperature. At an extended living room, the temperature difference from outside and inside, when blinds were installed inside, was $1.9^{\circ}C$ while it was $0.6^{\circ}C$ when the blinds were installed at outside of the balcony. It is evaluated that setting up the blind outside prevents much heat. At the space with a normal balcony, installing blinds at living room windows can save much heat compare to installing blinds at windows at the balcony. The indoor temperature was low when blinds were installed. It can be said that blinds block heat from the incoming solar radiation. Moreover, when blinds are installed, there is a big change of indoor temperature due to the radiation from the blinds' slat and convective activities in between the blinds and windows. This also has to be considered.