• 제목/요약/키워드: amplitude-comparison

검색결과 428건 처리시간 0.032초

Comparison of Tillage and Loads Characteristics of Three Types of Rotavators: Rotary-type, Crank-type, and Plow-type

  • Kim, Myoung-Ho;Nam, Ju-Seok;Kim, Dae-Cheol
    • Journal of Biosystems Engineering
    • /
    • 제38권2호
    • /
    • pp.73-80
    • /
    • 2013
  • Purpose: This study was conducted to compare tillage and loads characteristics of three types of rotavators in farmland working condition of Korea. Methods: Tillage operations using three types of rotavators, i.e. rotary-type, crank-type and plow-type, were carried out in a dry field of Korea. The same prime mover tractor was used for driving three types of rotavators, and under several operational conditions, tillage characteristics such as actual working speed, rotavating depth, rotavating width, actual field capacity, flow of tilled soil, soil inversion ratio, and pulverizing ratio were measured. In addition, loads characteristics like torque and required power of Power Take-Off (PTO) shaft were calculated. Results: The average rotavating depth was smaller than the nominal value for all rotavators, and the difference was the greatest in the plow-type rotavator. Nevertheless, the plow-type rotavator showed the largest rotavating depth. The rotavating width was the same as the nominal value of all rotavators. The flow of tilled soil at the same operational conditions was the greatest in the plow-type rotavator and was the smallest in the rotary-type rotavator. In the most commonly used gear conditions of L2 and L3, the average soil pulverizing ratio was the greatest in the rotary-type rotavator, and followed by crank-type and plow-type rotavators in order. In the gear L2 and L3, the plow-type rotavator also had the lowest average soil inversion ratio while the rotary-type and crank-type rotavators had the same soil inversion ratio each other. The average torque and power of PTO shaft in the gear L2 and L3 were the highest in the plow-type rotavator. The load spectra of PTO shaft applying rain flow counting method and Smith-Waston-Topper equation to the measured torque showed that the modified torque amplitude was the greatest in the crank-type rotavator. This may come from the large torque fluctuation of crank-type rotavator during tillage operations. Conclusions: The three types of rotavators had different tillage and loads characteristics. The plow-type rotavator had the deepest rotavating depth, the smallest soil inversion ratio, the largest soil pulverizing ratio and required PTO power. Also, the crank-type rotavator showed a large torque fluctuation because of their unique operational mechanism. This study will help the farmers choose a suitable type of rotavator for effective tillage operations.

Comparison of Upper Extremity Muscle Activity With Transverse Plane Angle Changes During Vertical Keyboard Typing (타이핑 작업 시 수직형 키보드의 수평면 끼인각 변화에 따른 상지의 근활성도 비교)

  • Lee, Kang-Jin;Roh, Jung-Suk;Kim, Tack-Hoon;Cynn, Heon-Seock;Choi, Houng-Sik;Oh, Dong-Sik
    • Physical Therapy Korea
    • /
    • 제16권2호
    • /
    • pp.67-76
    • /
    • 2009
  • In order to prevent upper extremity musculoskeletal disorders, effective keyboard selection is an important consideration. The aim of this study was to compare upper extremity muscle activity according to transverse plane angle changes during vertical keyboard typing. Sixteen healthy men were recruited. All subjects had a similar typing ability (rate of more than 300 keystrokes per minute) and biacromion and forearm-fingertip lengths. Four different types of keyboard (vertical keyboard with a transverse plane angle of $60^{\circ}$, $96^{\circ}$, or $120^{\circ}$, and a standard keyboard) were used with a wrist support. The test order was selected randomly for each subject. Surface electromyography (EMG) was used to measure upper extremity muscle activity during a keyboard typing task. The collected EMG data were normalized using the reference contraction and expressed as a percentage of the reference voluntary contraction (%RVC). In order to analyze the differences in EMG data, a repeated one-way analysis of variance, with a significance level of .05, was used. Bonferroni correction was used for multiple comparisons. There were significant differences in the EMG amplitude of all seven muscles (upper trapezius, middle deltoid, anterior deltoid, extensor carpi radialis, extensor carpi ulnaris, flexor carpi radialis, and flexor carpi ulnaris) assessed during the keyboard typing task. The mean activity of each muscle had a tendency to increase as the transverse plane angle increased. The mean activity recorded during all vertical keyboard typing was lower than that recorded during standard keyboard typing. There was no significant difference in accuracy and error scores; however, there was a significant difference between transverse plane angles of $60^{\circ}$ and $120^{\circ}$ with regard to comfort. In conclusion, a vertical keyboard with a transverse plane angle of $60^{\circ}$ would be effective in reducing muscle activity compared with vertical keyboards with other transverse plane angles.

  • PDF

Comparison and Optimization of Parallel-Transmission RF Coil Elements for 3.0 T Body MRI (3.0 T MRI를 위한 병렬전송 고주파 코일 구조 비교와 최적화)

  • Oh, Chang-Hyun;Lee, Heung-K.;Ryu, Yeun-Chul;Hyun, Jung-Ho;Choi, Hyuk-Jin
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • 제44권4호통권316호
    • /
    • pp.55-60
    • /
    • 2007
  • In high field (> 3 T) MR imaging, the magnetic field inhomogeneity in the target object increases due to the nonuniform electro-magnetic characteristics of the relatively high RF frequency. Especially in the body imaging, the effect causes more serious problems resulting in locally high SAR(Specific Absorption Ratio). In this paper, we propose an optimized parallel-transmission RF coil and show the utility of the coil by FDTD simulations to overcome the unwanted effects. Three types of TX coil elements are tested to maximize the efficiency and their driving patterns(amplitude and phase) optimized to have adequate field homogeneity, proper SAR level, and sufficient field strength. For the proposed coil element of $25cm{\times}8cm$ loop structure with 12 channels for a 3.0 T body coil, the field non-uniformity of more than 70% without optimization was reduced to about 26 % after the optimization of driving patterns. The experimental as well as simulation results show that the proposed parallel driving scheme is clinically useful for (ultra) high field MRI.

The Modified Direct Torque Control System for Five-Phase Induction Motor Drives (5상 유도전동기 구동을 위한 수정된 직접 토크제어 시스템)

  • Kim, Min-Huei;Kim, Nom-Hun;Baik, Won-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • 제23권2호
    • /
    • pp.138-147
    • /
    • 2009
  • In this paper, improved direct torque control(DTC) system for five-phase squirrel-cage induction motor(IM) is proposed. Due to the additional degrees of freedom, five-phase 1M drives present unique characteristics. Also five-phase motor drives possess many other advantages compared with the traditional three-phase motor drive system, such as reducing an amplitude of torque pulsation and increasing the reliability. The DTC method is advantageous when it is applied to the five-phase IM, because the five-phase inverter provides 32 space vectors in comparison to 8 space voltage vectors into the three-phase inverter. However, five-phase motor has structural drawback of 3rd space-harmonics current component, it is necessary to controlled 3rd harmonic current. So to control 3rd harmonic current and enhance dynamic characteristics of five-phase squirrel-cage IM drive, modified DTC method should be demanded. The characteristics and dynamic performance of traditional five-phase DTC are analyzed and new DTC for five-phase IM is presented. A more precise flux and torque control algorithm for the drives can be suggested and explained For presenting the superior performance of the proposed direct torque control, experimental results are presented using a 32-[bit] fixed point TMS320F2812 digital signal processor with 2.2[kW] induction motor.

Performance Analysis of Adaptive Corner Shrinking Algorithm for Decimating the Document Image (문서 영상 축소를 위한 적응형 코너 축소 알고리즘의 성능 분석)

  • Kwak No-Yoon
    • Journal of Digital Contents Society
    • /
    • 제4권2호
    • /
    • pp.211-221
    • /
    • 2003
  • The objective of this paper is performance analysis of the digital document image decimation algorithm which generates a value of decimated element by an average of a target pixel value and a value of neighbor intelligible element to adaptively reflect the merits of ZOD method and FOD method on the decimated image. First, a target pixel located at the center of sliding window is selected, then the gradient amplitudes of its right neighbor pixel and its lower neighbor pixel are calculated using first order derivative operator respectively. Secondly, each gradient amplitude is divided by the summation result of two gradient amplitudes to generate each local intelligible weight. Next, a value of neighbor intelligible element is obtained by adding a value of the right neighbor pixel times its local intelligible weight to a value of the lower neighbor pixel times its intelligible weight. The decimated image can be acquired by applying the process repetitively to all pixels in input image which generates the value of decimated element by calculating the average of the target pixel value and the value of neighbor intelligible element. In this paper, the performance comparison of proposed method and conventional methods in terms of subjective performance and hardware complexity is analyzed and the preferable approach for developing the decimation algorithm of the digital document image on the basis of this analysis result has been reviewed.

  • PDF

Comparison of Current Density on Iontophoretic Transdermal Delivery of Methylene Blue in Rat Skin (이온도입의 전류밀도에 따른 메틸렌 블루의 경피전달 효과 비교)

  • Lee, Jae-Hyoung;Kim, Jin-Kyung;Kwon, Pil-Seung;Jekal, Seung-Joo
    • Journal of the Korean Society of Physical Medicine
    • /
    • 제9권2호
    • /
    • pp.133-140
    • /
    • 2014
  • PURPOSE: The purpose of this study was to compare the effect of current density on penetration depth, tissue concentration and transdermal transport of methylene blue(MB) by iontophoretic transdermal delivery. METHODS: Twenty-four male Sprague-Dawley rats were randomly divided into 1 mA($0.11mA/cm^2$), 2 mA($0.22mA/cm^2$), 4 mA($0.44mA/cm^2$), and 8 mA($0.89mA/cm^2$) groups. These rats were exposed to anodic iontophoresis of 1% MB using a direct current for 15 minutes. The penetration depth were measured using light microscopy from cryosections of skin tissue. The tissue concentration and transdermal transport were measured using biochemical analysis from target skin tissues. The data were analyzed with one-way analysis of variance. RESULTS: The significant differences in the penetration depth, tissue concentration and transdermal transport were detected among the groups(p<.001). Post hoc comparisons of the penetration depth, tissue concentration and transdermal transport of he 2 mA, 4 mA, and 8 mA iontophoresis groups were greater than in the 1 mA iontophoresis group(p<.05). There was no significant difference, however, among 2 mA, 4 mA, and 8 mA iontophoresis group. CONCLUSION: There was no difference in the efficiency of iontophoresis from 2 mA($0.22mA/cm^2$) to 8 mA($0.89mA/cm^2$). Higher current density can cause skin injury and discomfort sensation. In general, $0.5mA/cm^2$ is proposed to be the maximum iontophoretic current which should be used on human. The appropriate current amplitude should be selected by considering the safety current density and the depth of the target tissue.

Study on Characteristics of SCC and AE Signals for Weld HAZ of HT-60 Steel (HT-60강 용접부의 SCC및 AE신호특성에 관한 연구)

  • Na, Eui-Gyun;Yu, Hyo-Sun;Kim, Hoon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • 제21권1호
    • /
    • pp.62-68
    • /
    • 2001
  • In order to characterize the microscopic fracture behaviour of the weldment din stress corrosion cracking(SCC) phenomena, SCC and acoustic emission(AE) tests were carried out simultaneously and the correlation between mechanical paramenters obtained from SCC and AE tests was investigated. In the case of base metal, much more AE events were produced at -0.5V than at -0.8V because of the dissolution mechanism before the maximum load. Regardless of the applied voltages to the specimens, however, AE events decreased after the maximum load. In the case of weldment, lots of AE events with larger amplitude $range(40{\sim}100dB)$ were produced because of the singularities of weld HAZ in comparision to the base metal and post-weld heat-treated(PWHT) specimens. Numerous and larger cracks for the weldment were observed on the fractured surfaces by SEM examination. From these results, it was concluded that SCC for the weldment appeared most severely in synthetic seawater. Weld HAZ was softened by PWHT which also contributed to the reduced susceptibility to corrosive environment in comparison to the weldment.

  • PDF

Lateral Femoral Cutaneous Nerve Somatosensory Evoked Potential Study in Normal Adults (정상성인의 외측대퇴피부신경 체감각 유발전위 검사)

  • Moon, Seung-Sik;Park, Mee-Young
    • Journal of Yeungnam Medical Science
    • /
    • 제18권1호
    • /
    • pp.67-74
    • /
    • 2001
  • Background: Meralgia paresthetica(MP) which is characterized by paresthesias and sensory impairment without motor weakness in the anterolateral aspects of the thigh is produced by compression of the lateral femoral cutaneous nerve(LFCN). Even though the diagnosis of MP is mostly based on the clinical symptoms, electrophysiologic study is mandatory to confirm the disease objectively. It has been known that Somatosensory evoked potential(SSEP) study of LFCN is a simple and very useful method to evaluate MP, so we studied SSEP of LFCN in normal adults and offer normal values. Materials and Methods: Thirty six normal adults(23 males and 13 females) ages from 21 to 73 years old($mean{\pm}SD$:$42.06{\pm}15.74$) were studied SSEP of LFCN bilaterally. The stimulation site was anterolateral aspect of thighs and the recording site was Cz'. Results: The mean values($mean{\pm}SD$) of $LP_0$, $SP_0$, $LN_1$ and $SN_1$ of all subjects were 35.10(${\pm}2.42$), 33.80(${\pm}2.4$), 43.68(${\pm}1.88$) and 42.16(${\pm}2.12$) and the mean values($mean{\pm}SD$ of $DP_0$, $DN_1$ and DA(${\mu}V{\pm}SD$ were 1.30(${\pm}1.14$), 1.52(${\pm}1.38$) and 0.32(${\pm}0.33$). Conclusion: For the diagnosis of MP. comparison of latency difference between both sides is more reliable than simple value of latency itself because of individual differences of body types. According to our results. the latency difference should be less than 2 msec and the amplitude difference was less than 1.6 times in normal adults.

  • PDF

Variation of the Sea Surface Height around the Korean Peninsula with the Use of Multi-satellite Data (Topex/Poseidon, Jason-1, ERS, Envisat) and its Association with Sea Surface Temperature (복합위성자료(Topex/Poseidon, Jason-1, ERS, Envisat)를 이용한 한반도 주변해역에서의 해수면 고도 변화와 해수면 온도의 상관성 연구)

  • Ha, Kyung-Ja;Jeong, Gi-Yong;Jang, Sae-Rom;Kim, Ki-Young
    • Korean Journal of Remote Sensing
    • /
    • 제22권6호
    • /
    • pp.519-531
    • /
    • 2006
  • Sea surface height (SSH) around fe Korean Peninsula was investigated as a rising rate of $3.89mm\;yr^{-1}$ on the average from 1993 to 2005, which is 1.3 times higher rising rate, compared to the world ocean. In the present study, to investigate SSH changes in regional sections of the East Sea, the Yellow Sea, the South Sea, and the Korea Strait, DT-MSLA (Delayed Time-Maps of Sea Level Anomalies) with multi-satellite data (Topex/Poseidon, Jason-1, ERS, Envisat), provided by AVISO (Archiving, Validation and Interpretation of Satellite Oceanographic data), was used. The periodicity in interannual variability was dominant for $4\sim5$ year in summer, and 3 year in winter as well as an increasing trend. The amplitude and phase for the annual and semi-annual mode in SSH and SST were investigated with harmonic analysis. The geographical distribution of amplitudes for comparison of SSH and SST are slightly reverse in southwest-northeast tilted direction. The monthly SST and SSH is highly correlated correlation coefficient about 0.7 with lag of one or two months over the East Sea and the South Sea during June-August. These results suggest that the Kuroshio stream is dominant during summer over these regions.

Performance Analysis of Monopulse System Based on Third-Order Taylor Expansion in Additive Noise (부가성 잡음이 존재하는 모노펄스 시스템 성능의 3차 테일러 전개 기반 해석적 분석)

  • Ham, Hyeong-Woo;Kim, Kun-Young;Lee, Joon-Ho
    • Journal of Convergence for Information Technology
    • /
    • 제11권12호
    • /
    • pp.14-21
    • /
    • 2021
  • In this paper, it is shown how the performance of the monopulse algorithm in the presence of an additive noise can be obtained analytically. In the previous study, analytic performance analysis based on the first-order Taylor series and the second-order Taylor series has been conducted. By adopting the third-order Taylor series, it is shown that the analytic performance based on the third-order Taylor series can be made closer to the performance of the original monopulse algorithm than the analytic performance based on the first-order Taylor series and the second-order Taylor series. The analytic MSE based on the third-order Taylor approximation reduces the analytic MSE error based on the second-order Taylor approximation by 89.5%. It also shows faster results in all cases than the Monte Carlo-based MSE. Through this study, it is possible to explicitly analyze the angle estimation ability of monopulse radar in an environment where noise jamming is applied.