• Title/Summary/Keyword: amplitude-comparison

Search Result 428, Processing Time 0.03 seconds

Comparison of P300 between Schizophrenia and Bipolar Disorder (정신분열병과 양극성 장애의 P300 비교)

  • Park, In-Joon;Jeong, Hee-Yeon;Kwon, Young-Joon
    • Korean Journal of Biological Psychiatry
    • /
    • v.8 no.1
    • /
    • pp.123-130
    • /
    • 2001
  • Objective : Asymmetries in evoked potential P300 topography of schizophrenia and bipolar disorder are still controversial. The purpose of this study was to examine the difference in P300 topography between schizophrenia and bipolar disorder. Method : P300 was recorded from 16 schizophrenic, 15 bipolar manic, and 16 control subjects. All were right-handed. Subjects silently counted target stimuli(2.0kHz) among trains of standard stimuli(1.0kHz). Averages were constructed from brain responses to target stimuli. Results : 1) Schizophrenics displayed significantly smaller peak amplitude of P300 over Cz, Pz, T3 than controls. 2) Schizophrenics displayed significantly smaller peak amplitude of P300 over T3 than bipolar manics. 3) Schizophrenics displayed significantly smaller peak amplitude of P300 over T3 than their T4. 4) Schizophrenics displayed significantly delayed latency of P300 over T3 than bipolar manics. 5) Schizophrenics displayed significantly delayed latency of P300 over T3 than their T4. Conclusions : Left-sided P300 abnormality, especially left superior temporal gyrus, in schizophrenics relative to bipolar manics and controls suggests that psychophysiological cause of schizophrenia and bipolar disorder is different and P300 asymmetry is specific to the psychophysiological cause of schizophrenia.

  • PDF

CA/C Ratio of Adults in Their Early Twenties with Normal Binocular Vision (양안시가 정상인 20대 초반 성인의 CA/C비)

  • Lee, Mu-Hyuk;Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.2
    • /
    • pp.153-158
    • /
    • 2012
  • Purpose: The purpose of this study was to evaluate the convergence accommodation to convergence (CA/C) ratio and to investigate relationships among age, accommodative amplitude and PD (interpupillary distance) of adults in their early twenties with normal binocular vision. Methods: 44 subjects (mean age, $21.75{\pm}1.16$ years) with healthy eyes were examined. The CA/C ratios were measured by using the difference of Gaussian (DOG) target with retinoscopy. Results: The mean CA/C ratio was $0.052{\pm}0.017$ D/$\Delta$. A moderate negative correction was present between CA/C ratio and age (r = -0.50, p = 0.0005), and a highly positive correction was found between CA/C ratio and accommodative amplitude (r = 0.79, p<0.0001). There was no relation between PD and CA/C ratio. Conclusions: The CA/C ratio presented was mean value for adults in their early twenties with healthy eye between 19 and 25 years of age. There was a high correlation between accommodative amplitude and CA/C ratio. Therefore, the CA/C ratio will be useful basic information for comparison in age, gender and binocular anomalies with similar data from other countries.

A NEW HARDWARE CORRELATOR IN KOREA: PERFORMANCE EVALUATION USING KVN OBSERVATIONS

  • Lee, Sang-Sung;Oh, Chung Sik;Roh, Duk-Gyoo;Oh, Se-Jin;Kim, Jongsoo;Yeom, Jae-Hwan;Kim, Hyo Ryoung;Jung, Dong-Gyu;Byun, Do-Young;Jung, Taehyun;Kawaguchi, Noriyuki;Shibata, Katsunori M.;Wajima, Kiyoaki
    • Journal of The Korean Astronomical Society
    • /
    • v.48 no.2
    • /
    • pp.125-137
    • /
    • 2015
  • We report results of the performance evaluation of a new hardware correlator in Korea, the Daejeon correlator, developed by the Korea Astronomy and Space Science Institute (KASI) and the National Astronomical Observatory of Japan (NAOJ). We conduct Very Long Baseline Interferometry (VLBI) observations at 22 GHz with the Korean VLBI Network (KVN) in Korea and the VLBI Exploration of Radio Astrometry (VERA) in Japan, and correlated the aquired data with the Daejeon correlator. For evaluating the performance of the new hardware correlator, we compare the correlation outputs from the Daejeon correlator for KVN observations with those from a software correlator, the Distributed FX (DiFX). We investigate the correlated flux densities and brightness distributions of extragalactic compact radio sources. The comparison of the two correlator outputs shows that they are consistent with each other within < 8%, which is comparable with the amplitude calibration uncertainties of KVN observations at 22 GHz. We also find that the 8% difference in flux density is caused mainly by (a) the difference in the way of fringe phase tracking between the DiFX software correlator and the Daejeon hardware correlator, and (b) an unusual pattern (a double-layer pattern) of the amplitude correlation output from the Daejeon correlator. The visibility amplitude loss by the double-layer pattern is as small as 3%. We conclude that the new hardware correlator produces reasonable correlation outputs for continuum observations, which are consistent with the outputs from the DiFX software correlator.

The comparison of the BAD and the BCD methods in a P300-based concealed information test (P300 숨긴정보검사에서 BAD 방법과 BCD 방법의 비교)

  • Eom, Jin-Sup
    • Korean Journal of Forensic Psychology
    • /
    • v.12 no.2
    • /
    • pp.151-169
    • /
    • 2021
  • In the P300-based concealed information test, most commonly used methods to detect whether a subject is lying are the bootstrapped amplitude difference (BAD) and the bootstrap correlation difference (BCD). Previous studies comparing the accuracy of the two methods reported inconsistent results. Most studies showed that the BAD is more accurate than the BCD, but some studies found that the BCD had a higher accuracy rate than the BAD. The purpose of the study is to identify conditions where the each method has higher accuracy compared to the other. In the result of Monte Carlo study, the false alarm rate of the BAD was generally higher than that of the BCD, and the hit rate of the BAD was higher than that of the BCD. Compared to the condition where the P300 latencies of probe and irrelevant were similar, the hit rate of the BCD was decreased when the P300 latency of probe was about 100 ms faster, and the hit rate of the BCD was increased when the P300 latency of probe was about 100 ms slower. When the P300 amplitude of the probe was slightly larger than that of the irrelevant and the P300 latency of probe was longer than that of target, the hit rate of the BCD was higher than that of the BAD. The reason why the false alarm rate of the BAD is higher than that of BCD and why the hit rate of the BCD is affected by the P300 latency of the probe were discussed.

Comparison of Word Level Stress Features between Korean, English and the Interlanguage of Korean Learners of English (영어 학습자의 중간 언어 단어 수준 강세 비교)

  • Lee, Yunhyun
    • The Journal of the Korea Contents Association
    • /
    • v.20 no.11
    • /
    • pp.378-390
    • /
    • 2020
  • English stress plays such a critical role in understanding spoken English words that its misplacement can lead to a breakdown of communication. Korean learners of English, whose native language is known to lack this feature, are expected to have some difficulty acquiring this English prosodic system. This study explored how Korean is different from English in manifesting prominence at the word level and how the interlanguage of Korean learners of English is dissimilar to both languages in that regard. Four polysyllabic English loanwords in Korean and their English source words were used as stimuli. Ten native English speakers read the English source words while ten Korean learners of English read the English loan words first and then the English source words. The analysis of 120 speech samples revealed that Korean words did not have any salient syllable realized by all stress features: duration, amplitude, and F0. On the contrary, English words had syllables with relative prominence, which was consistently manifested by all the features. Interestingly, in realizing English stress, the interlanguage of the Korean English learners bore more resemblance to that of English than that of their native language.

Changes of Action Potential of Central Neuron by Maximal Voluntary Isometric Contraction (최대 수의적 등척성 수축력에 의한 중추신경원의 활동전위 변화)

  • Moon, Dal-Ju;Kim, Kye-Yoep;Jeong, Jin-Gyu;Kim, Sue-Hyun;Kim, Tae-Youl
    • The Journal of Korean Physical Therapy
    • /
    • v.18 no.3
    • /
    • pp.37-45
    • /
    • 2006
  • Purpose: This study analyzed changes in spinal neuron and action potential of motor unit depending on voluntary contraction on spinal neuron adaptation. Methods: It selected 80 university students in their twenties and divided into experimental groups of 25% MVIC (I), 50% MVIC (II), 75% MVIC (III) and 100% MVIC (IV) depending on maximum voluntary isometric contraction (MVIC) and performed isometric exercise of plantar flexor muscle to each experimental group with given contraction for 20 times. It measured Mmax, H/Mmax, Hmax latency, V/Mmax, V wave latency before and after exercise, compared method and volume of contraction. Results: H/Mmax ratio showed significant difference in comparison among groups (p<0.01) and there was difference in I and IV groups. V/Mmax ratio showed significant difference in comparison among experimental groups (p<0.05) and there was difference in I and IV groups. When voluntary contraction level was maximum, changes were greatest. However, no significantly difference was to Mmax, H latency and V wave latency. Conclusion: These results suggest that amplitude changes of voluntary contraction level, spinal neuron and supra-spinal neuron had a dose connection that the more contraction level, the better central activation seem to decrease highly for a short time.

  • PDF

Comparison of Topex/Poseidon sea levels data and Tide Gause sea levels data from the South Indian Ocean (남인도양에서의 해수면에 대한 위성자료(Topex/Poseidon 고도계)와 현장자료(Tide Gauge 해면계)간의 비교)

  • 윤홍주;김상우;이문옥;박일흠
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.10a
    • /
    • pp.281-285
    • /
    • 2001
  • According to standard procedures as defined in the users handbook for sea level data processes, I was compared to Topex/poseidon sea level data from the first 350days of mission and Tide Gauge sea level data from the Amsterdam- Crozet- Kerguelen region in the South Indian Ocean. The comparison improves significantly when many factors for the corrections were removed, then only the aliased oceanic tidal energy is removed by oceanic tide model in this period. Making the corrections and smoothing the sea level data over 60km along-track segments and the Tide Gauge sea level data for the time series results in the digital correlation and RMS difference between the two data of c=-0.12 and rms=11.4cm, c=0.55 and rms=5.38cm, and c=0.83 and rms=2.83cm for the Amsterdam, Crozet and Kerguelen plateau, respectively. It was also found that the Kerguelen plateau has a comparisons due to propagating signals(the baroclinic Rossby wave with velocity of -3.9~-4.2cm/sec, period of 167days and amplitude of 10cm) that introduce temporal lags($\tau$=10~30days) between the altimeter and tide gauge time series. The conclusion is that on timescales longer than about 10days the RMS sea level errors are less than or of the order of several centimeters and are mainly due to the effects of currents rather than the effects of sterics(water temperature, density) and winds.

  • PDF

The Effects of Breath-Counting Meditation on Sasang Constitution (수식관 호흡이 사상체질에 미치는 영향)

  • Bae, Hyo-Sang;Kim, Ji-Hwan;Lee, Yong-Jae;Son, Han-Beom;Park, Seong-Sik
    • Journal of Sasang Constitutional Medicine
    • /
    • v.27 no.2
    • /
    • pp.231-239
    • /
    • 2015
  • Objectives The purpose of this study is to find out whether or not there are differences of effects when we count breaths on inspiration or expiration, and how differently the effects show up according to gender or Sasang Constitution Methods A group of 79 participants were enrolled and diagnosed Sasang Constitution by Sasang Constitution Diagnosis System of the Korea Institute of Oriental Medicine. Physical responses to respiratory changes were measured by Biofeedback sensors that were attached to the participants while they were seated comfortably on a sofa and breathing normally without counting for 5 minutes, counting on inspiration for 5 minutes, and counting on expiration for 5 minutes. Results and Conclusions 1. Mean heart rate and respiration rate decreased in association with breathing counting on inspiration and expiration more than breathing normally without counting. Especially respiration rate was stabilized during counting on inspiration and mean heart rate was stabilized during counting on expiration. 2. Interaction between breathing methods and gender did not appear. In comparison between gender, LF/HF ratio was higher in male during breathing normally without counting and counting on inspiration. Body temperature was higher in male during counting on inspiration and expiration. 3. Interaction between breathing methods and Sasang Constitution did not appear. In comparison between Sasang Constitution, mean heart rate was higher in Soyang-in, Soeum-in than Taeeum-in and abdominal amplitude was lower in Taeeum-in than Soeum-in.

A computer based simulation model for the fatigue damage assessment of deep water marine riser

  • Pallana, Chirag A.;Sharma, Rajiv
    • Ocean Systems Engineering
    • /
    • v.12 no.1
    • /
    • pp.87-142
    • /
    • 2022
  • An analysis for the computation of Fatigue Damage Index (FDI) under the effects of the various combination of the ocean loads like random waves, current, platform motion and VIV (Vortex Induced Vibration) for a certain design water depth is a critically important part of the analysis and design of the marine riser platform integrated system. Herein, a 'Computer Simulation Model (CSM)' is developed to combine the advantages of the frequency domain and time domain. A case study considering a steel catenary riser operating in 1000 m water depth has been conducted with semi-submersible. The riser is subjected to extreme environmental conditions and static and dynamic response analyses are performed and the Response Amplitude Operators (RAOs) of the offshore platform are computed with the frequency domain solution. Later the frequency domain results are integrated with time domain analysis system for the dynamic analysis in time domain. After that an extensive post processing is done to compute the FDI of the marine riser. In the present paper importance is given to the nature of the current profile and the VIV. At the end we have reported the detail results of the FDI comparison with VIV and without VIV under the linear current velocity and the FDI comparison with linear and power law current velocity with and without VIV. We have also reported the design recommendations for the marine riser in the regions where the higher fatigue damage is observed and the proposed CSM is implemented in industrially used standard soft solution systems (i.e., OrcaFlex*TM and Ansys AQWA**TM), Ms-Excel***TM, and C++ programming language using its object oriented features.

Comparison of Muscle Activity and Input Performance of Operators Using a Computer Mouse and a Trackball

  • Yoo, Hwan-Suk;Yi, Chung-Hwi;Kwon, Ho-Yun;Jeon, Hye-Seon;Yoo, Won-Gyu
    • Physical Therapy Korea
    • /
    • v.16 no.4
    • /
    • pp.37-43
    • /
    • 2009
  • This study compared the electromyographic activities and input performance of computer operators using a computer mouse and a trackball. Muscle activities were assessed at the upper trapezius (UT), middle deltoid (MD), extensor digitorum (ED), and first dorsal interosseous muscle (FDI). Twenty-six healthy subjects were recruited, and the test order was selected randomly for each subject. The task set was to click moving targets on a Windows program. The EMG amplitude was normalized using the percentage of reference voluntary contraction for UT and MD and the percentage of maximal voluntary contraction for ED and FDI. To analyze the differences in EMG activity, a paired t-test was used. UT muscle activities were significantly greater when the computer mouse was used (p<.05). FDI muscle activities were significantly greater when the trackball was used (p<.05). Using a trackball can reduce the load on the UT during computer work and help to prevent and manage work-related musculoskeletal disorders.

  • PDF