• Title/Summary/Keyword: amplitude permeability

Search Result 28, Processing Time 0.03 seconds

Numerical Analysis of Through Transmission Pulsed Eddy Current Testing and Effects of Pulse Width Variation

  • Shin, Young-Kil;Choi, Dong-Myung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.3
    • /
    • pp.255-261
    • /
    • 2007
  • By using numerical analysis methods, through transmission type pulsed eddy current (PEC) testing is modeled and PEC signal responses due to varying material conductivity, permeability, thickness, lift-off and pulse width are investigated. Results show that the peak amplitude of PEC signal gets reduced and the time to reach the peak amplitude is increased as the material conductivity, permeability, and specimen thickness increase. Also, they indicate that the pulse width needs to be shorter when evaluating the material conductivity and the plate thickness using the peak amplitude, and when the pulse width is long, the peak time is found to be more useful. Other results related to lift-off variation are reported as well.

Annealing Effect of Permeability Spectra in Amorphous Fe83Zr7B8Cu2

  • Kim, C.G.;Ryu, G.H.;Yu, S.C.;Moon, Y.M.;H.K. Lachowicz
    • Journal of Magnetics
    • /
    • v.3 no.2
    • /
    • pp.41-43
    • /
    • 1998
  • The frequency spectra of complex permeability have been measured as a function of ac field amplitude in the annealed amorphous $Fe_{83}Zr_7B_8Cu_2 $ ribbons. The longitudinal permeability results from the rotational magnetization at small fields, $h_o$<5 mOe in as-quenched samples. However, at the further increase of ho, the wall motion begins to be involved in the low frequency region. The permeability from the wall motion drastically decreases in the annealed sample, while that from the rotational magnetization increases up to annealing temperature of 50$0^{\circ}C$ and then drops there after.

  • PDF

Changes of Hysteresis Loop Characteristics of the Tendon Under Tensile Stress (Tendon의 인장응력에 따른 자기이력특성 변화의 측정)

  • Kang, Sunju;Son, Derac;Joh, Changbin;Lee, Jungwoo
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.4
    • /
    • pp.123-128
    • /
    • 2015
  • The iron is an element having a high yield strength, mechanical hardness, good electrical conductivity, and also it has been used in various fields because of ease machining. In bridges have been used tendon made of a steel wire for large loads and light weight. Tension measurement of tendon employed in PreStressed Concrete (PSC) bridge is very important for the bridge safety check. NDT (Non-Destructive Testing) is essential for the safety check, however, magnetic NDT is difficult to apply due to the non-linear magnetization curve and hysteresis loop in the magnetic properties. In this work, for basic study of magnetic NDT application, we have constructed a B-H loop measuring system for 7-strand tendon of which diameter is 15.5 mm, and which can apply tensile stress up to 2.0 GPa. We have measured hysteresis loops of two kinds of tendons under different tensile stress. Amplitude permeability and maximum magnetic induction near knee show the most sensitive and high linearity depends on tensile stress. Relative amplitude permeability was decreased from 500 to 200 and maximum magnetic flux density changed 0.6 T.

Higher Expression of TRPM7 Channels in Murine Mature B Lymphocytes than Immature Cells

  • Kim, Jin-Kyoung;Ko, Jae-Hong;Nam, Joo-Hyun;Woo, Ji-Eun;Min, Kyeong-Min;Earm, Yung-E;Kim, Sung-Joon
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.9 no.2
    • /
    • pp.69-75
    • /
    • 2005
  • TRPM7, a cation channel protein permeable to various metal ions such as $Mg^{2+}$, is ubiquitously expressed in variety of cells including lymphocytes. The activity of TRPM7 is tightly regulated by intracellular $Mg^{2+}$, thus named $Mg^{2+}$-inhibited cation (MIC) current, and its expression is known to be critical for the viability and proliferation of B lymphocytes. In this study, the level of MIC current was compared between immature (WEHI-231) and mature (Bal-17) B lymphocytes. In both cell types, an intracellular dialysis with $Mg^{2+}$-free solution (140 mM CsCl) induced an outwardly-rectifying MIC current. The peak amplitude of MIC current and the permeability to divalent cation ($Mn^{2+}$) were several fold higher in Bal-17 than WEHI-231. Also, the level of mRNAs for TRPM7, a molecular correspondence of the MIC channel, was significantly higher in Bal-17 cells. The amplitude of MIC was further increased, and the relation between current and voltage became linear under divalent cation-free conditions, demonstrating typical properties of the TRPM7. The stimulation of B cell receptors (BCR) by ligation with antibodies did not change the amplitude of MIC current. Also, increase of extracellular $[Mg^{2+}]_c$ to enhance the $Mg^{2+}$ influx did not affect the BCR ligation-induced death of WEHI-231 cells. Although the level of TRPM7 was not directly related with the cell death of immature B cells, the remarkable difference of TRPM7 might indicate a fundamental change in the permeability to divalent cations during the development of B cells.

Analysis of Thermo Chemically Decomposing Composites for Rocket Thermal Insulators (로켓 방화벽용 열경화성 복합재의 거동해석)

  • Lee, Sunpyo;Lee, Jung-Youn
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.5 no.4
    • /
    • pp.1-11
    • /
    • 2001
  • A theory for time-dependent, high temperature ablation of poroelastic carbon composite insulators is applied using finite element methods to determine material properties from experimental data. The theory contains important revisions to that in Lee, Salamon and Sullivan[1] by making a sharp distinction between Biots constants and permeability and setting both to analytical functions of porosity. The finite element program and material modeling has been modified to (1) more closely adhere to porous-material theory, (2) include a newly discovered analytical simplification and (3) refine the material property descriptions. Application to experimental problems and comparisons with data permit determination of Biots constants and permeability and their evolution with respect to matrix decomposition and clearly show how material parameters affect the material response, e.g., amplitude and the location of peaks with respect to temperature. In particular, the response is very sensitive to permeability and dominated by it.

  • PDF

Submerged Membrane Breakwaters I: A Rahmen Type System Composed of Horizontal and Vertical Membranes

  • Kee, Sung-Tae
    • International Journal of Ocean Engineering and Technology Speciallssue:Selected Papers
    • /
    • v.5 no.1
    • /
    • pp.14-21
    • /
    • 2002
  • In the present paper, the hydrodynamic properties of a Rahmen-type, flexible, porous breakwater interacting with obliquely or normal- incident small amplitude waves are numerically investigated. This system is composed of dual vertical porous membranes, hinged at the side edges of a submerged horizontal membrane. The dual vertical membranes are extended downward and hinged at seabed. The effects of permeability, Rahmen-type membrane breakwater geometry, pre-tensions on membranes, relative dimensionless wave number, and incident wave headings are thoroughly examined.

  • PDF

Correlation Between Mechanical and Magnetic Properties for Cold Rolled Carbon Steel Sheet (냉연강판의 기계적 물성과 자기적 특성의 상관관계)

  • Park, S.Y.;Ryu, K.S.;Yi, J.K.;Park, J.S.
    • Journal of the Korean Magnetics Society
    • /
    • v.16 no.4
    • /
    • pp.211-215
    • /
    • 2006
  • Measurement methods in order to measure the mechanical properties nondestructively have been studied. The mechanical properties of the structural and turbine rotor steels are related with their magnetic properties. If the magnetic properties of the cold rolled carbon steel sheet (CR) for a car are measured nondestructively, its mechanical properties are analogized by their magnetic properties. And then the mechanical properties are monitored on-line by measuring the magnetic properties. We prepared three CR materials, CBQ 3060, CBQ 3041, and CBQ 3036, were prepared in order to measure their mechanical and magnetic properties. The Vickers hardness,yield strength, and tensile strength were measured by ASTM E 8M, and the reversible magnetic permeability was measured by the surface type probe. The coercivity calculated by the peak interval of reversible magnetic permeability increased linearly with the increase of Vickers hardness, yield strength, and tensile strength. The amplitude of the peak interval of reversible magnetic permeability drastically decreased when the lift-off was increased.

Variation of Magnetic Properties of Cu-Zn-Mg Ferrites with Various Compositions and Sintering Temperatures (Cu-Zn-Mg ferrite의 조성성분 및 소결온도에 따른 자기적 특성변화 연구)

  • Koh, Jae-Gui
    • Korean Journal of Materials Research
    • /
    • v.13 no.6
    • /
    • pp.365-368
    • /
    • 2003
  • Small amounts of additives such as mol % 0.13 NiO and mol % 0.01 $CaCO_3$were added to Cu-Zn-Mg ferrites. Basic composition of the Cu-Zn-Mg ferrites was $Cu_{Cu}$X/$Fe_{0.054}$ /$Zn_{0.486}$$Mg_{0.407}$ $Fe_{1.946}$ $O_4$(group A) and $Cu_{0.263}$$Fe_{0.027}$ $Zn_{0.503}$ $Mg_{0.262}$ $Fe_{1.973}$ $O_4$(group B). Specimens were sintered at different temperatures (1010, 1030, $1050^{\circ}C$) for 2 hours in air followed by an air cooling. Then, effects of various composition and sintering temperatures on the microstructure and the magnetic properties such as inductions, coercive forces, and initial permeabilities of the Cu-Zn-Mg ferrites were investigated. The average grain size increased with the increase of sintering temperature. The magnetic properties obtained from the aforementioned Cu-Zn-Mg ferrite specimens were 1,724 gauss for the maximum induction, 1.0 oersted for the coercive force, and 802 for the initial permeability. These magnetic properties indicated that the specimens could be utilized as the core of IFT (intermediate frequency transformer) and antenna in the amplitude modulation.

Simulation study on porosity disturbance of ultra-large-diameter jet borehole excavation based on water jet coal wetting and softening model

  • Guo, Yan L.;Liu, Hai B.;Chen, Jian;Guo, Li W.;Li, Hao M.
    • Geomechanics and Engineering
    • /
    • v.30 no.2
    • /
    • pp.153-167
    • /
    • 2022
  • This study proposes a method to analyze the distribution of coal porosity disturbances after the excavation of ultra-large-diameter water jet boreholes using a coal wetting and softening model. The high-pressure jet is regarded as a short-term high-pressure water injection process. The water injection range is the coal softening range. The time when the reference point of the borehole wall is shocked by the high-pressure water column is equivalent to the time of high-pressure water injection of the coal wall. The influence of roadway excavation with support and borehole diameter on the ultra-large-diameter jet drilling excavation is also studied. The coal core around the borehole is used to measure the gas permeability for determining the porosity disturbance distribution of the coal in the sampling plane to verify the correctness of the simulation results. Results show that the excavation borehole is beneficial to the expansion of the roadway excavation disturbance, and the expansion distance of the roadway excavation disturbance has a quadratic relationship with the borehole diameter. Wetting and softening of the coal around the borehole wall will promote the uniform distribution of the overall porosity disturbance and reduce the amplitude of disturbance fluctuations.

Submerged Membrane Beakwaters II: A Rahmen Type System Composed of Horizontal and Vertical Membranes

  • Kee S.T.
    • Proceedings of the Korean Society of Coastal and Ocean Engineers Conference
    • /
    • 2004.08a
    • /
    • pp.150-159
    • /
    • 2004
  • In the present paper, the hydrodynamics properties of a Rahmen type flexible porous breakwater with dual fixed-pontoon system interacting with obliquely or normally incident small amplitude waves are numerically investigated. This system is composed of dual vertical porous membranes hinged a the side edges of dual fixed pontoons, and a submerged horizontal membrane that both ends are hinged at the steel frames mounted pontoons. The dual vertical membranes are extended downward and hinged at bottom steal frame fixed into seabed. The wave blocking and dissipation mechanism and its effects of permeability, Rahmen type membrane and pontoon geometry, pre-tensions on membranes, relative dimensionless wave number, and incident wave headings are thoroughly examined.

  • PDF