• Title/Summary/Keyword: amplitude of vibration

Search Result 1,041, Processing Time 0.023 seconds

Vibration Control for a Single Degree of Freedom Structure Using Active Friction Slip Braces (능동 조임 마찰 가새로 보강한 단자유도 구조물의 응답)

  • Lee, Jin-Ho;Zekai, Akbay;Kim, Jung-Gil;Oh, Sang-Gyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.1
    • /
    • pp.131-138
    • /
    • 2006
  • Structural bracing concept equipped with a new and efficient friction based energy dissipation device is referred to Friction SliP Brace (FSB) where the behavior of the brace components is elastic until the axial resistant force in the brace exceeds the friction force developed at the frictional interface of the device. In this study, the FSB concept is modified and new type of hybrid energy dissipation device, the Active Friction SliP Braces (AFSB), is described. The FSB is by far improved in the AFSB by inclusion of an active clamping mechanism on the friction interface. The clamping action regulated by the developed algorithm is altered during the response of the building. The results indicate that the action of dissipating vibrational energy in the AFSB impacts on the response at later cycles by keeping the drift amplitudes at much lower levels, revealing overshooting problem due to its early slippage. Providing predetermined constant incremental strengths to the building by AFSB medium improves response by reducing drift amplitudes and base shear under small and medium amplitude ground accelerations.

A Study on Input Multiplexer for Ku-Band Satellite Transponder (Ku 대역 위성 중계기용 입력 멀티플렉서에 관한 연구)

  • 이주섭;엄만석;염인복;이성팔
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.4
    • /
    • pp.393-400
    • /
    • 2003
  • This paper deals with the design and manufacturing technique of EQM(Engineering Qualification Model) of input multiplexer(IMUX) for the Ku-band satellite transponder. Channel dropping method by circulator chain structure is adopted for demultiplexing each channel. External equalizers are attached behind channel filters fur reduction of group delay variation and amplitude variation simultaneously. Both channel filters and equalizers adopted dual-mode technique in design f3r mass and volume reduction. Channel filters are designed to have 8-pole elliptic response and equalizers to be of 2-pole reflection type. For good temperature stability characteristics, INVAR36 material is used for channel filters and external equalizers. Vibration test, Thermal Vacuum Test, and EMC test have been performed on input multiplexer and it is shown to be suitable for Ku-band satellite transponder.

Direct Non-stepwise Multiple Quantum Excitations in Translation-Vibration Energy Transfer (竝進-振動에너지 變換에 있어서의 多量子 直接 振動 勵起)

  • Yoo Hang Kim;Hyung Kyu Shin
    • Journal of the Korean Chemical Society
    • /
    • v.20 no.2
    • /
    • pp.97-110
    • /
    • 1976
  • Effects of direct multiple quantum excitations in vibrational energy transfer were investigated. Vibrational transition probabilities for 0${\rightarrow}$2, 0${\rightarrow}$3, and 0${\rightarrow}$4 excitations were explicitly formulated including both direct 0→n excitations and stepwise single quantum processes. For the formulation the perturbing force was derived from the exponential potential including terms up to fourth order in the vibrational amplitude. The head-on collinear collision model between a harmonic oscillator and an incident particle was employed, and the formulation was based on the semiclassical approximation. Numerical results were obtained for five different collision systems (Ar${\cdots}$O-N, He${\cdots}$H-H, He${\cdots}$H-Cl, 5${\cdots}$1-2, 2${\cdots}$12-12). Comparison between the present results and those obtained using the linearized interaction potential showed that the overall effect of including the direct multiple quantum transition is to decrease the probabilities at low collision energies and to increase them at high energies. The present results were found to be significantly different from those obtained using the linearized potential for collision systems He${\cdots}$H-H, He${\cdots}$H-Cl, and 5${\cdots}$1-2. For systems Ar${\cdots}$O-N and 2${\cdots}$12-12 the differences were negligible.

  • PDF

Study on frequency response of implantable microphone and vibrating transducer for the gain compensation of implantable middle ear hearing aid (이식형 마이크로폰과 진동체를 갖는 인공중이의 이득 보상을 위한 주파수 특성 고찰)

  • Jung, Eui-Sung;Seong, Ki-Woong;Lim, Hyung-Gyu;Lee, Jang-Woo;Kim, Dong-Wook;Lee, Jyung-Hyun;Kim, Myoung-Nam;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.361-368
    • /
    • 2010
  • ACROSS device, which is composed of an implantable microphone, a signal processor, and a vibrating transducer, is a fullyimplantable middle ear hearing device(F-IMEHD) for the recovery of patients with hearing loss. And since a microphone is implanted under skin and tissue at the temporal bones, the amplitude of the sound wave is attenuated by absorption and scattering. And the vibrating transducer attached to the ossicular chain caused also the different displacement from characteristic of the stapes. For the gain control of auditory signals, most of implantable hearing devices with the digital audio signal processor still apply to fitting rules of conventional hearing aid without regard to the effect of the implanted microphone and the vibrating transducer. So it should be taken into account the effect of the implantable microphone and the vibrating transducer to use the conventional audio fitting rule. The aim of this study was to measure gain characteristics caused by the implanted microphone and the vibrating transducer attached to the ossicle chains for the gain compensation of ACROSS device. Differential floating mass transducers (DFMT) of ACROSS device were clipped on four cadaver temporal bones. And after placing the DFMT on them, displacements of the ossicle chain with the DFMT operated by 1 $mA_{peak}$ current was measured using laser Doppler vibrometer. And the sensitivity of microphones under the sampled pig skin and the skin of 3 rat back were measured by stimulus of pure tones in frequency from 0.1 to 8.9 kHz. And we confirmed that the microphone implanted under skin showed poorer frequency response in the acoustic high-frequency band than it in the low- to mid- frequency band, and the resonant frequency of the stapes vibration was changed by attaching the DFMT on the incus, the displacement of the DFMT driven with 1 $mA_{rms}$ was higher by the amount of about 20 dB than that of cadaver's stapes driven by the sound presssure of 94 dB SPL in resonance frequency range.

Phonatory Caracteristics of Vwels and Resonant Consonants using the Electroglottography (전기성문파형검사를 이용한 모음과 공명 자음의 발성특성)

  • Choi, Seong-Hee;Nam, Do-Hyun;Lim, Jae-Yol;Lim, Sung-Eun;Choi, Hong-Shik
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.15 no.2
    • /
    • pp.133-140
    • /
    • 2004
  • Background and Objectives : Vowels and resonant including nasals and liquid are produced with vocal folds vibration have been used for voice therapy of hyperadduction patients. This study was conducted to investigate phonatory characteristics of vowels and resonant consonants through the EGG measures from Lx. Speech studio (Laryngograph Ltd, UK). Materials and Method : 7 male adults produced sustained vowel /a/, /i/, /u/, nasals /m/, /n/, /${\eta}$/and liquid /I/ and read the sentences (1nasals-liquid sentence, 1 non-nasals-liquid sentence) and tongue-tip trill and humming. Fx(Hz), Ox(%) were obtained of vowels, nasals, liquid and each of the posterior vowel /a/ of /ma/, /na/, /la/, /ha/ with same F0(around F#165Hz) and amplitude (75${\pm}$5db). And also DFx(Hz), DQx(%), CFx(%) and CAx(%) were obtained from reading two kinds of sentences. Results : Qx(%) was the highest in /u/ of vowels, and nasal/n/ of the resonant consonants and nasals-liquid sentence was higher Qx than non-nasals-liquid sentence but significant differences were not found. Qx(%) of the posterior vowel /a/ of nasal consonants/n/ was higher than in the isolated vowel/a/ and other posterior vowel of resonant consonants and fricatives /h/. Regularity or periodicity and higher Qx were observed in the nasals-liquid sentence than non-nasals-liquid sentence in graphs of QxFx & CFx produced by Quantiative analysis. In the nasalance score, /u/vowel was significant higher among the vowels and /I/ liquid was significant lower among the resonant consonants and nasals-liquid sentence is higher than non-nasals -liquid sentence. CQ(%) was not significantly correlated with nasalance(%). Conclusion : These findings might signify resonant phonation was not correlated with nasalance.

  • PDF

Change of Extracellular Matrix of Human Vocal Fold Fibroblasts by Vibratory Stimulation (진동이 성대세포주의 세포외기질 변화에 대한 연구)

  • Kim, Ji Min;Shin, Sung-Chan;Kwon, Hyun-Keun;Cheon, Yong-Il;Ro, Jung Hoon;Lee, Byung-Joo
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.32 no.1
    • /
    • pp.15-23
    • /
    • 2021
  • Background and Objectives During speech, the vocal folds oscillate at frequencies ranging from 100-200 Hz with amplitudes of a few millimeters. Mechanical stimulation is an essential factor which affects metabolism of human vocal folds. The effect of mechanical vibration on the cellular response in the human vocal fold fibroblasts cells (hVFFs) was evaluated. Materials and Method We created a culture systemic device capable of generating vibratory stimulations at human phonation frequencies. To establish optimal cell culture condition, cellular proliferation and viability assay was examined. Quantitative real time polymerase chain reaction was used to assess extracellular matrix (ECM) related and growth factors expression on response to changes in vibratory frequency and amplitude. Western blot was used to investigate ECM and inflammation-related transcription factor activation and its related cellular signaling transduction pathway. Results The cell viability was stable with vibratory stimulation within 24 h. A statistically significant increase of ECM genes (collagen type I alpha 1 and collagen type I alpha 2) and growth factor [transforming growth factor β1 (TGF-β1) and fibroblast growth factor 1 (FGF-1)] observe under the experimental conditions. Vibratory stimulation induced transcriptional activation of NF-κB by phosphorylation of p65 subunit through cellular Mitogen-activated protein kinases activation by extracellular signal regulated kinase and p38 mitogen-activated protein kinases (MAPKs) phosphorylation on hVFFs. Conclusion This study confirmed enhancing synthesis of collagen, TGF-β1 and FGF was testified by vibratory stimulation on hVFFs. This mechanism is thought to be due to the activation of NF-κB and MAPKs. Taken together, these results demonstrate that vibratory bioreactor may be a suitable alternative to hVFFs for studying vocal folds cellular response to vibratory vocalization.

A Study on the Improvement of Misfire Detection Method with Vibration by using the Weight Factor (후진동이 나타나는 실화 진단 방법에서 가중치를 이용한 성능 향상에 대한 연구)

  • Lim Jihoon;Lee Taeyeon;Kim Ealgoo;Hong Sungrul;Sung Jinho;Park Jaehong;Yoon Hyungjin;Park Jinseo;Kim Dongsun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.4
    • /
    • pp.74-80
    • /
    • 2005
  • This paper presents a misfire monitoring method by using the weight factor. According to OBD II(On-Board Diagnostics) regulations of the CARB (California Air Resources Board), an ECU (Electronic Control Unit) should detect misfires which occur in the internal combustion engine. A misfire is 1311owe4 by post-oscillations for short duration. Sometimes, the amplitude of oscillations may be as high as misfire and can be falsely detected as another misfire. To prevent this, the software designers do not attempt to detect another misfire for this short duration, during which the post oscillations exist. Because of this, ECU does not detect all the misfires and hence, the unstable state of automobile cannot be detected. If this happens for a long time, automobile may get damaged. To solve these problems, this paper suggests a new algorithm to detect misfire by using weighting factor Weighting factor is a concept to distinguish the misfire with the post oscillation and to improve the detection rate. This value of weighting factor is used for counting the misfire. This paper also shows the result of experiment done on a automobile using this software. The software is implemented using ASCET-SD which is preferred in the design of engine control. This paper's result show the possibility of improving the misfire detection by implementing this algorithm.

A Study of EEG Analysis for the Moxibustion Stimulation (간접 뜸 자극에 관한 EEG 분석)

  • Park, Dong-Hee;Yoon, Dong-Eop;Jo, Bong-Kwan;Song, Hong-Bock;Kim, Young-Jin
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.170-174
    • /
    • 2007
  • Although research efforts for brain waves have prospered in medicine and engineering, acupuncture still has a long way to go regarding researches on brain waves analysis. Thus this study set out to analyze brain waves stimulated by indirect mugwort moxibustion, which was part of acupuncture techniques, and to investigate their correlations with the automatic nervous system. For the experiments, stimulation was given to Jungwan, Shingwol and Gwanwon, which were some of the spots on the body suitable for acupuncture, through indirect mugwort moxibustion. The subjects' brain waves were measured before the stimulation, during the stimulation, and one hour and two hours after the stimulation. The measurements were analyzed with Matlab 7.0 for FFT and frequency power spectrum. Then the ${\alpha}$, ${\beta}$, ${\delta}$, and ${\theta}$ waves were analyzed and examined for changes to the percentage of each frequency and to the amplitude of vibration according to the stages of stimulation. The EEG data of the entire brain were translated into FFT to analyze the percentage of the ${\alpha}$, ${\beta}$, ${\delta}$, and ${\theta}$ waves. As a result, the ${\alpha}$ waves recorded a double increase after the stimulation. The power spectrum analysis results of the entire brain decreased the ${\alpha}$ and ${\beta}$ waves dropping in the energy level, which suggested that the parasympathetic nerves were activated. When the results of the study were compared with those of the previous study, it's confirmed that indirect moxibustion stimulation could cause changes to the automatic nervous system and bring stability to those who were nervous or under stress due to the proportionate increase of the ${\alpha}$ waves.

  • PDF

Flow Safety Assessment by CFD Analysis in One-Touch Insertion Type Pipe Joint for Refrigerant (CFD 해석을 이용한 냉매용 원터치 삽입식 파이프 조인트의 유동 안전성 평가)

  • Kim, Eun-young;Park, Dong-sam
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.3
    • /
    • pp.550-559
    • /
    • 2022
  • Purpose: Pipes are widely used as applied devices in many industrial fields such as machinery, electronics, electricity, and plants, and are also widely used in safety-related fields such as firefighting and chemistry. With the diversification of products, the importance of technology in the piping field is also increasing. In particular, when changing the existing copper pipe to stainless steel, it is necessary to evaluate safety and flow characteristics through structural analysis or flow analysis. Method: This study investigated the safety by flow analysis of the 6.35 inch socket model, which are integrated insert type connectors developed by a company, using CFD analysis technique. For CDF analysis, RAN model and LES model are used. Result: As results of the analysis, amplitude of the pressure fluctuation acting on the wall of the piping system is formed at a level of 3,780 Pa or less, which is a very small level of pressure compared with the operating pressure or design stress of the refrigerant piping. Conclusion: These results mean that the effect of vibration caused by turbulence on the structural safety of the pipe is negligible.

A comparison study of the effects of handpiece speed on teeth in debonding procedure (탈접착 후처치시 핸드피스(handpiece) 속도가 치아에 미치는 영향에 대한 비교 연구)

  • Park, Soo-Byung;Kim, Gu-Ho;Ha, Man-Hee
    • The korean journal of orthodontics
    • /
    • v.34 no.1 s.102
    • /
    • pp.83-91
    • /
    • 2004
  • This study was performed to examine treatment efficiency and patient discomfort rate according to used handpiece speed in clean-up technique. Brackets were bonded to extracted human premolar(50 teeth). After debonding, 50 extracted human premolar were divided Into each two groups(low speed handpiece group with tungsten carbide bur and high speed handpiece group with ultra-fine diamond finishing bur) of 25 according to used handpiece speed in clean-up technique. In clean-up procedure, teeth vibration and pulp thermal changes were measured. After clean-up procedure, the enamel surfaces of randomly selected 10 teeth from each two groups were taken by SEM and evaluated. The findings of this study were as follows ; 1. During resin removal, tooth vibrations of various amplitude in low speed handpiece group were more than those of high speed handpiece. 2. The pulpal thermal changes of high speed handpiece group were significantly higher than those of low speed handpiece group, also the resin removal time in high speed handpiece group was almost as twice as in low speed handpiece group. 3. The figures of SEM to enamel surfaces after resin removal showed that notches and resin remnants in high speed handpiece group were more than those in low speed handpiece group.