• Title/Summary/Keyword: amplitude field

Search Result 636, Processing Time 0.033 seconds

Vibration Control of Engine Mount Utilizing Smart Materials (지능재료를 이용한 엔진 마운트의 진동제어)

  • Song, Hyun-Jeong;Choi, Seung-Bok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.297-300
    • /
    • 2005
  • This paper presents vibration control of an engine mount for a passenger vehicle utilizing ER fluid and piezoelectric actuator. The proposed engine mount can be isolated the vibration of wide frequency range with many types of amplitude. The main function of ER fluid is to attenuate vibration for low frequency with large amplitude, while the piezoelectric actuator is activated in hish frequency range with small amplitude. A mathematical model of the engine mount is derived using Hydraulic model and mechanical model. After formulating the governing equation of motion, then field-dependent dynamic stiffness of the engine mount is evaluated for various engine speed and excitation amplitude conditions. Then robust controller is designed to attenuate vibration of wide range frequency component. Computer simulation is undertaken in order to evaluate the vibration control performance such as transmissibility magnitude in frequency domains.

  • PDF

Response Characteristics According to the Selection Procedure of Near Field EQGMS (Near field 지진기록 분류에 따른 특성 비교)

  • 배미혜;한상환
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2002.10a
    • /
    • pp.527-532
    • /
    • 2002
  • Near field ground motions contain distinct and large amplitude pulses in both velocity and displacement. This paper investigates characteristics of near field earthquakes and their effects on seismic demands. 20 EQGMs were selected for this purpose that satisfied 5 conditions for Near field motion. Among them ten EQGMs have one distinct peak velocity pulse in the velocity time history. In this study the responsed are Linear Elastic Response Spectrum(LERS), Response Modification Factor(R) and Inelastic Response Spectrum(IRS). The effect of the selection of Near field EQGMs on these response parameters are investigated.

  • PDF

Basic analysis of suitability for Toughened Glass Stem Insulator applied in the high speed catenary system (고속전차선로 유리애자 현장 적합성 기초연구)

  • Jeon, Yong-Joo;Ryu, Yong-Tae;Lee, Gi-Chun;Lee, Yoo-Kyung
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1067-1068
    • /
    • 2008
  • The Operation of high speed train in year 2004 bring about a great change in railroad industry. Especially in railroad construction field we have acquired great Know-how. And up to now we are building up operation skills. But the high speed train system are totally imported, so it is necessary to investigate some of the equipment based on our own environment. In case of Toughened Glass Stem Insulator, we don't have any application case in domestic and limited in abroad. So there must be some characteristic estimation. The estimation was made in three different ways. First electrical field cause, Second physical field cause and finally in circumstance cause. In Electrical field cause, amplitude and number of time for abnormal peak voltage data are collected. And in physical field cause, amplitude and trend of vibration in to the insulator are examined. And I circumstance cause, possibility of flying gravel and ice clod are investigated. Through this basic data suitability for Toughened Glass Stem Insulator using in domestic will be accumulated.

  • PDF

Basic analysis of suitability for Toughened Glass Stem Insulator applied in the high speed catenary system (고속전차선로 유리애자 현장 적합성 기초연구)

  • Jeon, Yong-Joo;Ryu, Young-Tae;Lee, Gi-Chun;Lee, Yoo-Kyung
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.423-427
    • /
    • 2008
  • The Operation of high speed train in year 2004 bring about a great change in railroad industry. Especially in railroad construction field we have acquired great Know-how. And up to now we are building up operation skills. But the high speed train system are totally imported, so it is necessary to investigate some of the equipment based on our own environment. In case of Toughened Glass Stem Insulator, we don't have any application case in domestic and limited in abroad. So there must be some characteristic estimation. The estimation was made in three different ways. First electrical field cause, Second physical field cause and finally in circumstance cause. In Electrical field cause, amplitude and number of time for abnormal peak voltage data are collected. And in physical field cause, amplitude and trend of vibration in to the insulator are examined. And I circumstance cause, possibility of flying gravel and ice clod are investigated. Through this basic data suitability for Toughened Glass Stem Insulator using in domestic will be accumulated.

  • PDF

AVO analysis using crossplot and amplitude polynomial methods for characterisation of hydrocarbon reservoirs (탄화수소 부존구조 평가를 위한 교차출력과 진폭다항식을 이용한 AVO 분석)

  • Kim, Ji-Soo;Kim, Won-Ki;Ha, Hee-Sang;Kim, Sung-Soo
    • Geophysics and Geophysical Exploration
    • /
    • v.14 no.1
    • /
    • pp.25-41
    • /
    • 2011
  • AVO analysis was conducted on hydrocarbon-bearing structures by applying the crossplot and offset-coordinate amplitude polynomial techniques. To evaluate the applicability of the AVO analysis, it was conducted on synthetic data that were generated with an anticline model, and field data from the hydrocarbon-bearing Colony Sand bed in Canada. Analysis of synthetic data from the anticline model demonstrates that the crossplot method yields zero-offset reflection amplitude and amplitude variation with negative values for the upper interface of the hydrocarbon-bearing layer. The crossplot values are clustered in the third quadrant. The results of AVO analysis based on the coefficients of the amplitude polynomial are similar to those from the crossplots. These well correlated results of AVO analysis on field and synthetic data suggest that both methods successfully investigate the characteristics of the reflections from the upper interface of a hydrocarbon-bearing layer. Analysis based on the incident-angle equation facilitates the application of various interpretation methods. However, it requires the conversion of seismic data to an incident angle gather. By contrast, analysis using coefficients of the amplitude polynomial is cost-effective because it allows examining amplitude variation with offset without involving the conversion process. However, it warrants further investigation into versatile application. The two different techniques can be complement each other effectively as AVO-analysis tools for the detection of hydrocarbon reservoirs.

Comparison of the Determinants in the Differences in Force-Frequency Relationships between Rat and Rabbit Left Atria

  • Ko, Chang-Mann;Kim, Soon-Jin
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.4 no.5
    • /
    • pp.417-425
    • /
    • 2000
  • The underlying mechanism commonly applicable for both the positive and negative force-frequency relationships (FFR) was pursued in left atria (LA) of rat and rabbit. The species differences in the roles of $Na^+/Ca^{2+}$ exchanger and sarcoplasmic reticulum (SR), which are major intracellular $Ca^{2+}$ regulatory mechanisms in the heart, were examined in the amplitude accommodation to the frequency that changed from 3 Hz to the variable test frequencies for 5 minutes in the electrically field stimulated left atria (LA) of rat and rabbit. Norepinephrine strongly increased the frequency-related amplitude accommodation in both of rat and rabbit LA, while monensin, oubain or the reduced $Na^+$ and 0 mM $Ca^{2+}$ containing Tyrode solution increased the frequency-related amplitude accommodation only in the rabbit LA. Monenisn was also able to increase the frequency-related amplitude accommodation only in 1-day old rat LA but not in 4-week old rat LA that had 75% less $Na^+/Ca^{2+}$ exchanger with 97% higher SR than 1-day old rat LA. Taken together, it is concluded that the differences in the prevalence between myocardial $Na^+/Ca^{2+}$ exchanger and SR in the amplitude accommodation to the frequency-change determine the difference in the FFR between rat and rabbit heart.

  • PDF

A Study on the Fatigue Crack Propagation Behavior in the SB41 Welding Material (SB41용접재의 피로크랙 진전거동에 관한 연구)

  • 최병기;장경천
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.11 no.2
    • /
    • pp.43-49
    • /
    • 2002
  • SB41 material is welded automatically and is investigated some effects of the welding residual stress in the growth and propagation of fatigue crack, so as to study the fatigue behaviour in the welding residual stress field. The summarized results are as follows; 1) In case of the load amplitude is constant, as the stress ratio is changing to 0.1, 0.33 and 0.5 the propagation life is constant but the growth life decreases. And than, when maximum load or minimum load is constant as the stress ratio increases the growth life and propagation life. 2) It was shown that fatigue crack propagation ratio da/dN was almost constant regardless of the stress ratio change at constant load amplitude and that the larger stress ratio, the slower was the fatigue crack propagation ratio. 3) The opening ratio U is influenced by $K_max$ but it isn't only the function of $K_max$ because data range is very large. 4) The fatigue life of the specimens on tensile compressive residual stress field was decreased and increased respectably more than that of the base metal.

PERFORMANCE OF AN OSCILLATING SUBSOILER IN BREAKIN HARD PAN

  • Bandalan, E.P.;Gupta, C.P.;Salokhe, V.M.;Niyamapa, T.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.1043-1052
    • /
    • 1993
  • Field experiments were conducted to determine the optimum combination of performance parameters of a single-shank, tractor-mounted oscillating subsoiler. Tests were conducted at frequencies of oscillation of 3.7 , 5.67, 7.58, 9.48 and 11.456Hz ; amplitudes of 18, 21, 23.5, 34 and 36.5 mm ; and forward speeds of 1.84, 2.19 and 3.42 kmph at moisture content close to the plastic limit of the soil. It was observed that there was a reduction in average draft but an a increase in average total power requirement for oscillating than non-oscillating subsoiling. The draft and power ratios were significantly affected by the forward speed, frequency and amplitude. Their combined interaction expressed in terms of the velocity ratio parameter( the ratio of peak tool velocity and forward speed) however has the strongest influence. At the same velocity ratio, the draft reduction and power increase were less at higher amplitude of oscillation . As the oscillating frequency is increased toward the soil resonance the draft requirement becomes less. For the field conditions tested. the optimum operation was obtained at an amplitude of 36.5mm, frequency of 9.48Hz and speed of 2.19 kmph with a draft ratio of 0.33 and a power ratio of only 1.24.

  • PDF

Frequency domain elastic full waveform inversion using the new pseudo-Hessian matrix: elastic Marmousi-2 synthetic test (향상된 슈도-헤시안 행렬을 이용한 탄성파 완전 파형역산)

  • Choi, Yun-Seok;Shin, Chang-Soo;Min, Dong-Joo
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.329-336
    • /
    • 2007
  • For scaling of the gradient of misfit function, we develop a new pseudo-Hessian matrix constructed by combining amplitude field and pseudo-Hessian matrix. Since pseudo- Hessian matrix neglects the calculation of the zero-lag auto-correlation of impulse responses in the approximate Hessian matrix, the pseudo-Hessian matrix has a limitation to scale the gradient of misfit function compared to the approximate Hessian matrix. To validate the new pseudo- Hessian matrix, we perform frequency-domain elastic full waveform inversion using this Hessian matrix. By synthetic experiments, we show that the new pseudo-Hessian matrix can give better convergence to the true model than the old one does. Furthermore, since the amplitude fields are intrinsically obtained in forward modeling procedure, we do not have to pay any extra cost to compute the new pseudo-Hessian. We think that the new pseudo-Hessian matrix can be used as an alternative of the approximate Hessian matrix of the Gauss-Newton method.

  • PDF

Highly-sensitive Magnetic Sensor using the Amplitude-Modulation (진폭변조를 이용한 고감도 자기센서)

  • 이상훈;남태철
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1995.05a
    • /
    • pp.90-95
    • /
    • 1995
  • This paper describes the highly-sensitive Si magnetic sensor using the amplitude modulation in order to real ice the integrated magnetic sensor which to sensor a weak magnetic field. Generally, the most important two parameters in Hall IC which degrade the ability of magnetic detection are the variation of offset according to the variation of temperature and the noise of amplifiers. In this paper, we use a Hall element and compensator to reduce the offset and the nouse of amplifiers by Using amplititude modulation method.

  • PDF