• Title/Summary/Keyword: amplitude difference

Search Result 651, Processing Time 0.025 seconds

A Study on Novel Hybrid Type Encoder Design for the Position Control with the High-resolution (고정도 위치제어용 Hybrid Type Encoder에 관한 연구)

  • Cho S. E.;Lee S. H.;Song S. G.;Park S. J.;Kwon S. J.;Kim C. U.
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.1
    • /
    • pp.87-94
    • /
    • 2005
  • This paper is about the compensation of phase angle error and amplitude difference in stationary 2 pole coordinates by the installation variation of sensor at low cost high resolution digital hybrid encoder. To solve the problem of amplitude difference at the existing hybrid encoder, we normalized the relative magnitude of the two analog signals. and also to solve the problem of installation variation when installed the sensor, we rotate the stationary 2 pole coordinates to compensate the location error of sensor. and we used and tested the QEP function and A/D port in DSP(TMS320F2812) to verify the mentioned proposed method.

Studies on control mechanism and performance of a novel pneumatic-driven active dynamic vibration absorber

  • Kunjie Rong;Xinghua Li;Zheng Lu;Siyuan Wu
    • Structural Engineering and Mechanics
    • /
    • v.87 no.2
    • /
    • pp.117-127
    • /
    • 2023
  • To efficiently attenuate seismic responses of a structure, a novel pneumatic-driven active dynamic vibration absorber (PD-ADVA) is proposed in this study. PD-ADVA aims to realize closed-loop control using a simple and intuitive control algorithm, which takes the structure velocity response as the input signal and then outputs an inverse control force to primary structure. The corresponding active control theory and phase control mechanism of the system are studied by numerical and theoretical methods, the system's control performance and amplitude-frequency characteristics under seismic excitations are explored. The capability of the proposed active control system to cope with frequency-varying random excitation is evaluated by comparing with the optimum tuning TMD. The analysis results show that the control algorithm of PD-ADVA ensures the control force always output to the structure in the opposite direction of the velocity response, indicating that the presented system does not produce a negative effect. The phase difference between the response of uncontrolled and controlled structures is zero, while the phase difference between the control force and the harmonic excitation is π, the theoretical and numerical results demonstrate that PD-ADVA always generates beneficial control effects. The PD-ADVA can effectively mitigate the structural seismic responses, and its control performance is insensitive to amplitude. Compared with the optimum tuning TMD, PD-ADVA has better control performance and higher system stability, and will not have negative effects under seismic wave excitations.

Bycatch Reduction by Experimental Shaking Codend Attached with Canvas in a Bottom Trawl

  • Kim, Yonghae
    • Fisheries and Aquatic Sciences
    • /
    • v.18 no.3
    • /
    • pp.325-332
    • /
    • 2015
  • An active stimulating method for juvenile fishes to drive escaping from mesh of the codend was examined by shaking canvas in the bottom trawl followed by shrimp beam trawl. Field fishing trials by a bottom trawl were carried out between the Geomoondo and Jejudo in west of South sea, Korea by conver-net methods to examine the effect on the reduction of juvenile fish as a discard catch by generating a shaking movement of the codend using two pieces of asymmetrical semi-circular canvas. The mean period of the shaking motion with the round canvas was 10-15 s, and the range of amplitude as a vertical depth change was up to 0.4-0.6 m when towing speed 3.4-4.3 k't as estimated by peak event analysis. The escape rate of juvenile fish in conver-net by total juvenile bycatch (codend and cover-net) in 14 trials increased from 20% in a steady codend to 34% using a shaking codend in the bottom trawl, while the marketing catch or total bycatch was similar between steady and shaking cod ends. There was no difference in the body size of the fish and species composition between the steady and shaking cod ends. Above results demonstrate a new method for bycatch reduction actually up to 18% using an active stimulating device, although further experiments are needed to increase an effective shaking motion of the codend in amplitude and period for more bycatch reduction.

Variation of the M2 tide amplitude around the Jeju-Do (제주도 주변 M 2조의 진폭변화)

  • Kim, Kuh;Lee, Sang-Ho
    • 한국해양학회지
    • /
    • v.21 no.3
    • /
    • pp.171-183
    • /
    • 1986
  • The amplitudes of the M2 tide recorded at Seoguipo and Jeju are 77.9cm and 70.1cm respectively, which differ by 7.8cm over a distance of 30km across the Jeju-Do. The difference is an example of the geographical variation of the tidal amplitude around the Jeju-Do, the larger amplitude being along its southern coast compared with that along its northern coast. This variation can be explained in terms of effects of an island on the wave propagation as modelled by Proudman(1914). A numerical experiment of the M2 tide around the Jeju-Do reproduces the basic pattern of the observed variation and results are consistent with the theory. Due to the rotation of the earth larger and smaller amplitudes result along the left-hand and right-hand coasts of an island for an observer facing the direction of the wave propagation in the northern hemisphere.

  • PDF

Evaluation of difference in respiratory phase between amplitude- and phase-based four-dimensional computed tomography (위상 기반 사차원전산화단층촬영과 진폭 기반 사차원전산화단층촬영 영상에서의 위상차 평가)

  • Lee, So Hyang;Park, Soo Yeon;Kim, Jong Sik;Choi, Byung Ki;Park, Hee Chul;Jung, Sang Hoon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.73-78
    • /
    • 2015
  • Purpose : Under the assumption of change to the amplitude based sorting, the study will use four dimensional computed tomography imaging (4DCT) arrayed using the phase based sorting to analyze the respiratory phase difference. Materials and Methods : The study analyzed the 4DCT (4-dimensional computed tomography) images of 10 liver cancer patients that were treated with respiratory gated radiotherapy from 2015 February to March. Using RPM respiratory gating (RPM 1.7.5, Varian, USA) equipment, imaging according to respiratory cycle of phase based sorting was acquired and using a treatment planning system (Pinnacle 9.2, Philips, USA) the acquired imaging according to respiratory cycle was used to measure the abdominal movement value by respiratory cycle. The measuring point was the point where the center point of the Marker Block and the body surface met in the 50% phase image and here the coordinate values Lateral, Vertical, Longitudinal (X, Y, Z) were set as reference points, and on the X, Z plane identical to the reference point, using the identical method the Y axis coordinate value of each 0%, 30%, 40%, 50%, 60%, 80% phase images were acquired to quantitatively measure the variation of distance to the Y axis. The abdominal movement value according to respiration was applied to the theoretical model that the value decreases linearly from maximum inhalation to maximum exhalation to divide the variation of my value to predict as amplitude value by respiratory cycle and conversely the variation in amplitude was recalculated with the phase variation deviation value to analyze. Results : The deviation value between expected value and actual location was the largest in the 30% phase with 0.24 cm, and standard deviation was also the largest in 30% phase with 0.13 cm. The effective value of the deviation value derived from the average of the deviation squared value of each patient appeared as minimum 0.7 cm, maximum 0.18 cm, average 0.12 cm, and standard deviation 0.4 cm. Also by dividing the actual movement distance value with the peak expiration value then converting it into %Phase, the deviation value with actual phase 16.5% in 30% phase, 10.0% and 40% phase, 10.0% and 60% phase, 15.4% and 80% phase, and overall average about 13%, and arraying based on amplitude, phase shift occurred and further it was from peak expiration the chance of deviation occurrence was increasingly measured. Conclusion : Based on the results of the study there were differences between value acquired based on theoretical model and actual value. Therefore in respiratory gated radiotherapy using external surrogates, there needs to be establishment of respiration gated radiation system that avoids the combination of two Sorting methods considering that there will be occurrence of treatment and corresponding clinical differences due to the phase difference that occur due to the Amplitude based Phase Sorting.

  • PDF

A Study on the Correlation Between Sasang Constitution and Sound Characteristics Used Harmonics and Formant Bandwidth (Harmonics(배음)와 Formant Bandwidth(포먼트 폭)를 이용한 음성특성(音聲特性)과 사상체질간(四象體質間)의 상관성(相關性) 연구(硏究))

  • Park, Sung-Jin;Kim, Dal-Rae
    • Journal of Sasang Constitutional Medicine
    • /
    • v.16 no.1
    • /
    • pp.61-73
    • /
    • 2004
  • This study was prepared to investigate the correlation between Sasang constitutional groups and voice characteristics using voice analysis system(in this study, CSL). I focused on the voice characteristics in terms of harmonics, Formant frequency and Formant Bandwidth. The subjects were 71 males. I classified them into three groups, that is Soeumin group, Soyangin group and Taeumin group. The classification method of Constitution used two ways, QSCCII(Questionnarie for the Sasang Constitution Classification II) and Interview with a specialist in Sasang Constitution. So 71 people were categorized into 31 Soeumin(people), 18 Soyangin(people) and 22 Taeumin(people). Pitch is approximately similar to the fundamental frequency(F0) in voices. Shimmer in dB gives an evaluation of the period-to-period variability of the peak-to-peak amplitude within the analyzed voice sample. FFT(Fast Fourier Transform) method in CSL can display sampled voices into harmonics. H1 is the first peak and h2 is the second peak in the harmonics. The amplitude difference of h1 and h2(h1-h2) can be explained as the speaker's phonation type, And Formant frequency and bandwidth can be explained as the speaker's vocal tract. So I checked the harmonics and Formant frequency and Bandwidth as the voice parameters. First I have captured /e/ voices from all subjects using microphone. And then I analyzed /e/ voices with CSL. Power Spectrum and Formant History is the menu in the CSL which can display harmonics and Formant frequency and bandwidth. The results about the correlation between Sasang Constitutional Groups and voice parameters are as follows; 1. There is no significant amplitude difference of harmonics(h1-h2) among three groups. 2. There is the significant difference between Soeumin Group and Soyangin Group in Formant Frequency 1 and Formant Bandwidth 1(p<0.05). Any other parameters have no significance. I assume that Soyangin Group has clearer and brighter voice than Soeumin Group according to the Formant Bandwidth difference. And I think its result has coincidence with the context of "Dongyi Suse Bowon" and "Sasangimhejinam".

  • PDF

A study on monitoring for process time and process properties by measuring vibration signals transmitted to the mold during injection molding (사출성형공정에서 금형에 전달되는 진동 신호 측정을 이용한 성형 단계별 공정시간과 공정특성의 모니터링에 대한 연구)

  • Lee, Jun-han;Kim, Jong-Sun
    • Design & Manufacturing
    • /
    • v.14 no.3
    • /
    • pp.8-16
    • /
    • 2020
  • In this study, the vibration signal of the mold was measured and analyzed to monitoring the process time and characteristics during injection molding. A 5 inch light guide plate mold was used to injection molding and the vibration signal was measured by MPU6050 acceleration sensor module attached the surface of fixed mold base. Conditions except for injection speed and packing pressure were set to the same value and the change of the vibration signal of the mold according to injection speed and packing pressure was analyzed. As a result, the vibration signal had a large change at three points: "Injection start", "V/P switchover", and "Packing end". The time difference between "injection start" and "V/P switchover" means the injection time in the injection molding process, and the time difference between "V/P switchover" and "Packing end" means the packing time. When the injection time and packing time obtained from the vibration signal of the mold are compared with the time recorded in the injection molding machine, the error of the injection time was 2.19±0.69% and the error of the packing time was 1.39±0.83%, which was the same level as the actual value. Additionally, the amplitude at the time of "injection start" increased as the injection speed increased. In "V/P switchover", the amplitude tended to be proportional to the pressure difference between the maximum injection pressure and the packing pressure and the amplitude at the "packing end" tended to the pressure difference between the packing pressure and the back pressure. Therefore, based on the result of this study, the injection time and packing time of each cycle can be monitored by measuring the vibration signal of the mold. Also, it was confirmed that the level and trend of process variables such as the injection speed, maximum injection pressure, and packing pressure can be evaluated as the change of the mold vibration during injection molding.

The comparison of the BAD and the BCD methods in a P300-based concealed information test (P300 숨긴정보검사에서 BAD 방법과 BCD 방법의 비교)

  • Eom, Jin-Sup
    • Korean Journal of Forensic Psychology
    • /
    • v.12 no.2
    • /
    • pp.151-169
    • /
    • 2021
  • In the P300-based concealed information test, most commonly used methods to detect whether a subject is lying are the bootstrapped amplitude difference (BAD) and the bootstrap correlation difference (BCD). Previous studies comparing the accuracy of the two methods reported inconsistent results. Most studies showed that the BAD is more accurate than the BCD, but some studies found that the BCD had a higher accuracy rate than the BAD. The purpose of the study is to identify conditions where the each method has higher accuracy compared to the other. In the result of Monte Carlo study, the false alarm rate of the BAD was generally higher than that of the BCD, and the hit rate of the BAD was higher than that of the BCD. Compared to the condition where the P300 latencies of probe and irrelevant were similar, the hit rate of the BCD was decreased when the P300 latency of probe was about 100 ms faster, and the hit rate of the BCD was increased when the P300 latency of probe was about 100 ms slower. When the P300 amplitude of the probe was slightly larger than that of the irrelevant and the P300 latency of probe was longer than that of target, the hit rate of the BCD was higher than that of the BAD. The reason why the false alarm rate of the BAD is higher than that of BCD and why the hit rate of the BCD is affected by the P300 latency of the probe were discussed.

Usefulness of Gated RapidArc Radiation Therapy Patient evaluation and applied with the Amplitude mode (호흡 동조 체적 세기조절 회전 방사선치료의 유용성 평가와 진폭모드를 이용한 환자적용)

  • Kim, Sung Ki;Lim, Hhyun Sil;Kim, Wan Sun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.29-35
    • /
    • 2014
  • Purpose : This study has already started commercial Gated RapidArc automation equipment which was not previously in the Gated radiation therapy can be performed simultaneously with the VMAT Gated RapidArc radiation therapy to the accuracy of the analysis to evaluate the usability, Amplitude mode applied to the patient. Materials and Methods : The analysis of the distribution of radiation dose equivalent quality solid water phantom and GafChromic film was used Film QA film analysis program using the Gamma factor (3%, 3 mm). Three-dimensional dose distribution in order to check the accuracy of Matrixx dosimetry equipment and Compass was used for dose analysis program. Periodic breathing synchronized with solid phantom signals Phantom 4D Phantom and Varian RPM was created by breathing synchronized system, free breathing and breath holding at each of the dose distribution was analyzed. In order to apply to four patients from February 2013 to August 2013 with liver cancer targets enough to get a picture of 4DCT respiratory cycle and then patients are pratice to meet patient's breathing cycle phase mode using the patient eye goggles to see the pattern of the respiratory cycle to be able to follow exactly in a while 4DCT images were acquired. Gated RapidArc treatment Amplitude mode in order to create the breathing cycle breathing performed three times, and then at intervals of 40% to 60% 5-6 seconds and breathing exercises that can not stand (Fig. 5), 40% While they are treated 60% in the interval Beam On hold your breath when you press the button in a way that was treated with semi-automatic. Results : Non-respiratory and respiratory rotational intensity modulated radiation therapy technique absolute calculation dose of using computerized treatment plan were shown a difference of less than 1%, the difference between treatment technique was also less than 1%. Gamma (3%, 3 mm) and showed 99% agreement, each organ-specific dose difference were generally greater than 95% agreement. The rotational intensity modulated radiation therapy, respiratory synchronized to the respiratory cycle created Amplitude mode and the actual patient's breathing cycle could be seen that a good agreement. Conclusion : When you are treated Non-respiratory and respiratory method between volumetric intensity modulated radiation therapy rotation of the absolute dose and dose distribution showed a very good agreement. This breathing technique tuning volumetric intensity modulated radiation therapy using a rotary moving along the thoracic or abdominal breathing can be applied to the treatment of tumors is considered. The actual treatment of patients through the goggles of the respiratory cycle to create Amplitude mode Gated RapidArc treatment equipment that does not automatically apply to the results about 5-6 seconds stopped breathing in breathing synchronized rotary volumetric intensity modulated radiation therapy facilitate could see complement.

Calculation of Wave Amplitude Functions, Wave Resistance, Wave Elevation Along the Hull, Sinkage and Trim by First-Order Thin-Ship Theory (얇은배 선형이론에 의한 진폭영수 조피저항 선측파고, 침하와 Trim의 계산)

  • Gang, Sin-Hyeong;Lee, Yeong-Gil;Hyeon, Beom-Su
    • 한국기계연구소 소보
    • /
    • s.9
    • /
    • pp.153-167
    • /
    • 1982
  • From first-order thin-ship theory, we can obtain the" wave resistance, wave amplitude functions, wave elevation along the hull, sinkage and trim of a ship moving with constant speed into calm water. Generally, these calculations of ship is called with Michell’s Theory, and there is all the difference between calculated wave resistance and residual resistance from conventional wave resis¬tance test. But, these calculated results are important reference materials for initial hull form design procedure. Various calculated results for Shearer’ s Model, Wigley’s Model and Series 60 4210W Model have been calculated using this theory. The results are compared with the corresponding experimental values, and the agreement between theoretical and experimental values is considered satisfactory.

  • PDF