• Title/Summary/Keyword: amplitude difference

Search Result 654, Processing Time 0.024 seconds

The Effect of Femoral Anteversion on Composite Hip and Thigh Muscle EMG Amplitude Ratio During Stair Ascent

  • Nam, Ki-Seok;Park, Ji-Won;Chae, Yun-Won
    • Physical Therapy Korea
    • /
    • v.12 no.1
    • /
    • pp.111-119
    • /
    • 2005
  • The purpose of this study was to compare the differences of hip and thigh muscle activities between subjects with increased and decreased femoral anteversion during stair ascent. Twelve healthy female volunteers participated in this study. The subjects were divided into two groups (group 1 with increased anteversion of the hip, group 2 with decreased anteversion of the hip). This study analyzed differences in each mean peak gluteus maximus (GM), gluteus medius (GD) and tensor fascia lata (TLF) EMG amplitude: composite mean peak hip muscles (GM, GD, TFL) EMG amplitude ratios and in each mean peak vastus medialis oblique (VMO), vastus lateralis (VL), biceps femoris (HM) and semitendinosus (HL) EMG amplitude: composite thigh muscles (VMO, VL, HM, HL) EMG amplitude ratios among subjects with decreased or increased relative femoral anteversion. EMG ratios were compared in the stance and swing phase of stair ascent. Group 1 showed an increased standardized mean GM and GD EMG amplitude and decreased standardized mean TFL to composite mean hip muscles EMG amplitude ratios in stair ascent during both stance and swing phase. Also, group 1 showed an increased standardized mean HL EMG amplitude and decreased standardized mean VL and HM to composite mean thigh muscles EMG amplitude ratios in stair ascent during both stance and swing phases. There was no statistically significant difference in vastus medialis oblique between subjects with increased or decreased relative femoral anteversion. In order to provide rehabilitation professionals with a clearer picture of the specific requirements of the stair climbing task, further research must be expanded to include a wider range of age groups that represent the general public, such as including middle-aged healthy persons.

  • PDF

Strategical Postures for Relieving EMG Amplitude Discrepancy on Bilateral Low Back Muscles and Total Low Back Muscle Fatigue while Lifting Asymmetric Load Dynamically (비대칭무게중심 물체의 동적 들기 작업시 좌.우 허리 근육의 EMG 진폭차이와 피로를 줄이기 위한 자세 연구)

  • Kim, Sun-Uk;Han, Seung-Jo
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.35 no.3
    • /
    • pp.103-109
    • /
    • 2012
  • The purpose of this paper is to suggest the strategical lifting postures able to alleviate imbalanced EMG amplitude leading to an increase in low back muscle fatigue while lifting asymmetric load dynamically. Eleven male subjects are required to lift symmetrically an external load with 15.8kg and load center of gravity (LCG) deviated 10cm to the right from the floor to the waist height at the speed of about 25cm/sec. The EMG amplitudes on bilateral low back muscles (Longissimus, Iliocostalis, and Multifidus) are recorded during 2sec and analyzed. Independent variables are trunk postures (No bending vs. Bending to the LCG) and feet placements (Parallel vs. Right foot in front of the other vs. Right foot behind the other). Dependent variables are EMG amplitude average on six muscles and the EMG amplitude difference between right and left muscle group. Results indicate the phenomenon showing an amplitude increase in the left muscle group is equal to an decrease in the right one is observed in dynamic as well as static lifts, bending the trunk to the LCG increases amplitude discrepancy more than no trunk bending, and the amplitude discrepancy in one foot ipsilateral to LCG in front of the other foot is lowest among other foot postures. As bilateral EMG amplitude discrepancy increases total low back muscle fatigue, the strategical combination of no trunk bending and one foot close to LCG in front of the other is recommended for preventing elevated incidence of low back pain (LBP).

N100 Amplitude Slopes in Major Depressive Disorder, Bipolar Disorder, Schizophrenia and Normal Controls (주요 우울 장애, 정신분열병, 양극성 장애 및 정상 대조군에서의 N100 진폭경사)

  • Yang, Eunkyoung;Lee, Seung-Hwan;Oh, Sunghee;Kim, Sangrae
    • Korean Journal of Biological Psychiatry
    • /
    • v.16 no.3
    • /
    • pp.181-189
    • /
    • 2009
  • Objectives : N100 amplitude slope(the intensity dependence of the cortical auditory evoked potentials) is widely considered as an indirect indicator of central serotonergic neurotransmission. However, there are only a few studies about N100 amplitude slopes of major psychiatric disorders. In this study, we examined N100 amplitude slope differences among major depressive disorder(MDD), bipolar disorder(BD), schizophrenia (SCZ) and normal controls(NC). Methods : We measured the N100 amplitude slopes of 35 patients with MDD, 33 patients with BD, 27 patients with SCZ and 35 NC subjects. Amplitude differences from N1 to P2 at the five different sound intensities(55, 65, 75, 85 and 95dB) were examined at Cz electrode. The N100 amplitude slope was calculated as the linear regression of five N1/P2 peak-to-peak amplitudes across stimulus intensities. Results : BD patients showed significantly reduced N100 amplitude slope compared with NC(0.54${\pm}$0.70 vs. 0.96${\pm}$0.72, p=0.035). N100 amplitude slope of SCZ patients was significantly reduced compared with NC(0.50${\pm}$0.47 vs. 0.96${\pm}$0.72, p=0.027). N100 amplitude slope of BD patients was significantly lower than that of MDD patients(0.54${\pm}$0.70 vs. 0.94${\pm}$0.60, p=0.046). SCZ patients also showed significant reduction of N100 amplitude slope compared with MDD patients(0.50${\pm}$0.47 vs. 0.94${\pm}$0.60, p=0.036). There was no significant difference of N100 amplitude slope between MDD patients and NC(0.94${\pm}$0.60 vs. 0.96${\pm}$0.72, p=1.000). Conclusion : Interestingly, the N100 amplitude slopes of BD and SCZ were reduced compared to NC and MDD patients. Our results suggest the predictive use of N100 amplitude slope in making differential diagnoses of major psychiatric disorders. Clinical implications of N100 amplitude slope in major psychiatric disorders were discussed.

  • PDF

A Technology of Microwave Direction Finding with Circular Array Combination Method (원형 배열 복합 방식을 이용한 초고주파 방향 탐지 기술)

  • Lim Joong-Soo;Jung Chul-Gu;Chae Gyoo-Soo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.6 s.97
    • /
    • pp.549-555
    • /
    • 2005
  • This paper describes a microwave direction finding technology which is used for RF signal acquisition and monitoring systems. This paper suggests a direction finding method which use a combination of the amplitude-comparison technology and the phase-comparison technology. The amplitude-comparison technology uses the amplitude difference of the RF signals received from the array antennas of direction finding system and removes the ambiguity of wave incident bearing. The phase-comparison technology uses the phase difference of the RF signals received from the same nay antennas and makes a good direction finding accuracy. The suggested direction finding technology is designed to place 8 array antennas in a $45^{\circ}$ distance around the circle for $360^{\circ}$ azimuth angle. Also it is designed to use the phase difference of the received signals ken two nearby antennas to measure the signal incident direction accurately and to use the amplitude difference to remove the ambiguity of wave incident bearing. The simulation and measurement results are under $0.5^{\circ}$ bearing error in $2.0\~6.0$ GHz when SNR is 30 dB.

Enhanced Amplitude Panning for Virtual Source Imaging (가상 음원 이미징을 위한 향상된 진폭 패닝 기법)

  • Hyun, Dong-Il;Park, Young-Cheol;Youn, Dae Hee
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.3
    • /
    • pp.139-145
    • /
    • 2013
  • In this paper, the problems of the conventional amplitude panning method for a stereophonic panning system are analyzed. We observed that the distortion showed a feedforward comb filter response. As a remedy to this distortion, we propose a stereophonic panning system using a feedback comb filter. The comb filter is designed to minimize the difference between interaural level difference(ILD) of the proposed system and that of HRTF because ILD is most salient cue for the perception of the source direction. The proposed system is configured to operate selectively for the frequency band related to the source direction. The performance of the proposed system is verified by subjective listening tests.

Comparison of the Determinants in the Differences in Force-Frequency Relationships between Rat and Rabbit Left Atria

  • Ko, Chang-Mann;Kim, Soon-Jin
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.4 no.5
    • /
    • pp.417-425
    • /
    • 2000
  • The underlying mechanism commonly applicable for both the positive and negative force-frequency relationships (FFR) was pursued in left atria (LA) of rat and rabbit. The species differences in the roles of $Na^+/Ca^{2+}$ exchanger and sarcoplasmic reticulum (SR), which are major intracellular $Ca^{2+}$ regulatory mechanisms in the heart, were examined in the amplitude accommodation to the frequency that changed from 3 Hz to the variable test frequencies for 5 minutes in the electrically field stimulated left atria (LA) of rat and rabbit. Norepinephrine strongly increased the frequency-related amplitude accommodation in both of rat and rabbit LA, while monensin, oubain or the reduced $Na^+$ and 0 mM $Ca^{2+}$ containing Tyrode solution increased the frequency-related amplitude accommodation only in the rabbit LA. Monenisn was also able to increase the frequency-related amplitude accommodation only in 1-day old rat LA but not in 4-week old rat LA that had 75% less $Na^+/Ca^{2+}$ exchanger with 97% higher SR than 1-day old rat LA. Taken together, it is concluded that the differences in the prevalence between myocardial $Na^+/Ca^{2+}$ exchanger and SR in the amplitude accommodation to the frequency-change determine the difference in the FFR between rat and rabbit heart.

  • PDF

Time-Delay and Amplitude Modified BP Imaging Algorithm of Multiple Targets for UWB Through-the-Wall Radar Imaging

  • Zhang, Huamei;Li, Dongdong;Zhao, Jinlong;Wang, Haitao
    • Journal of Information Processing Systems
    • /
    • v.13 no.4
    • /
    • pp.677-688
    • /
    • 2017
  • In order to solve the undetected probability of multiple targets in ultra-wideband (UWB) through-the-wall radar imaging (TWRI), a time-delay and amplitude modified back projection (BP) algorithm is proposed. The refraction point is found by Fermat's principle in the presence of a wall, and the time-delay is correctly compensated. On this basis, transmission loss of the electromagnetic wave, the absorption loss of the refraction wave, and the diffusion loss of the spherical wave are analyzed in detail. Amplitude compensation is deduced and tested on a model with a single-layer wall. The simulating results by finite difference time domain (FDTD) show that it is effective in increasing the scattering intensity of the targets behind the wall. Compensation for the diffusion loss in the spherical wave also plays a main role. Additionally, the two-layer wall model is simulated. Then, the calculating time and the imaging quality are compared between a single-layer wall model and a two-layer wall model. The results illustrate the performance of the time-delay and amplitude-modified BP algorithm with multiple targets and multiple-layer walls of UWB TWRI.

Runup and Reflection of Waves on Impermeable Slopes of Coastal Structures (불투수성 경사면에서 파의 처오름과 반사)

  • Lee, Cheol-Eung
    • Journal of Industrial Technology
    • /
    • v.21 no.B
    • /
    • pp.175-185
    • /
    • 2001
  • A numerical model is represented to calculate the reflected waves, the runup of waves and the wave induced velocities on impermeable slopes for the normally incident wave trains of nonlinear monochromatic wave and solitary wave. The finite amplitude shallow water equations with the effects of bottom friction are solved numerically in time domain using an explicit dissipative Lax-Wendroff finite difference method. The numerical model is verified by comparisons with the other numerical results, the measured data and asymptotic results. It is found that the uprushing and downrushing of incident waves may be accurately predicted by the present numerical model. Therefore, the present numerical model can be applicable to swells as well as long waves.

  • PDF

Genetic Algorithm Based Linear Region Extension for Multivariable Monopulse Tracking Systems (다변수 모노펄스 추적 시스템에서 유전 알고리즘 기반 선형구간 확장)

  • Jung, Jinwoo;Kim, Jaesin;Ryu, Young-Jae
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.272-278
    • /
    • 2017
  • In this paper, we consider a single-channel amplitude comparison monopulse system(SCACMS). The monopulse ratio curve(MR-C) of the SCACMS can be controlled by an amplitude difference between sum and different signal, a phase difference and the coefficient of the signal processor. We first propose the SCACMS with multiple variables, and then apply a genetic algorithm to optimize the multiple variables in terms of minimizing a root mean square error. The simulation results show that when three variables of the SCACMS are jointly optimized, the linear region of the MR-C can be extended approximately 187 % compared to that of two variables.

A study of optical characteristics correlated with low dielectric constant of SiOCH thin films through Ellipsometry (Ellipsometry를 이용한 저 유전 상수를 갖는 SiOCH박막의 광학특성 연구)

  • Park, Yonh-Heon;Hwang, Chang-Su;Kim, Hong-Bae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.198-198
    • /
    • 2010
  • The low-k SiOCH thin films were prepared by CCP-PECVD method using BTMSM(Bis-trimethylsilylmethane) precursors deposited on p-Si wafer. The structural complexity originate the complex refractive constants of the films, and resulted the elliptical polarization of the incident linearly polarized light source of Xe-ramp in the range from 190nm to 2100nm. Phase difference and amplitude ratio between s wave and p wave propagating through SiOCH thin film was studied. After annealing, the amplitude of p wave was reduced more than s wave, and phase difference between p and s wave was also reduced.

  • PDF