Pyo, Soeun;Park, Yoon Ghil;Park, Jinyoung;Ko, Eu Jeong
Journal of Electrodiagnosis and Neuromuscular Diseases
/
v.20
no.2
/
pp.98-105
/
2018
Objective: To evaluate whether the increase of the amplitude of motor evoked potentials (MEPs) during surgery can imply favorable prognosis postoperatively in spinal cord tumor surgery. Method: MEPs were monitored in patients who underwent spinal cord tumor surgery between March 2016 and March 2018. Amplitude changes at the end of monitoring compared to the baselines in limb muscle were analyzed. Minimum and maximum changes were set to $MEP_{min}$ (%) and $MEP_{max}$ (%). Strengths of bilateral 10 key muscles which were documented a day before ($Motor_{pre}$), 48 h ($Motor_{48h}$) and 4 weeks ($Motor_{4wk}$) after the surgery were reviewed. Results: Difference of $Motor_{48h}$ from $Motor_{pre}$ ($Motor_{48h-pre}$) and $Motor_{4wk}$ from $Motor_{pre}$ ($Motor_{4wk-pre}$) positively correlated with $MEP_{min}$, suggesting that smaller the difference of MEPs amplitude, less recovery of muscle strength. There was a negative correlation between the amount of bleeding and $MEP_{min}$, indicating that the greater the amount of bleeding, the smaller the $MEP_{min}$, implying that MEPs amplitude is less likely to improve when the amount of bleeding is large. It also showed significant difference between patients with improved or no change of motor status and patients with motor deterioration after surgery according to anatomical tumor types. Conclusion: Improve of muscle strength was less when the increase of MEPs amplitude was small, and improvement of MEPs amplitude was less when the amount of bleeding was large. Correlation between changes of status of muscle strength after surgery and tumor types was observed. With amplitude increase in MEPs monitoring, restoration of muscle strength can be expected.
Journal of The Korean Society of Integrative Medicine
/
v.8
no.2
/
pp.131-138
/
2020
Purpose : The purpose of this study was to investigate the effects of the frequency band pass filter on the P300 event-related potential in the working memory. Methods : The subjects were 20 women in their 20s who applied for participation in the experiment. Event-related potentials (ERPs) were elicited using 3-back tasks for the working memory, and were recorded from Fz, Cz, and Pz scalp electrodes. The high-pass filters were set to 0.01, 0.1, and 0.3 Hz for analysis purposes, and the low-pass filters were set to 30 and 15 Hz. The 3-back task was presented for a total of 100 times, among which 30 times were designated for the target stimulation (a matched number) and 70 times for the non-target stimulation (an unmatched number). The temporal interval between each stimulation was set at 1 second, while each time duration was randomly presented between 2 to 4 seconds. ERP were analyzed for the P300 recorded from Fz, Pz and Cz scalp electrodes. Results : Latency and amplitude had no significant interaction effects in both the high- and low-pass filters. For the main effects, the latency and amplitude of the P300 event-related potential had no significant difference in the high-pass filters, but the latency had a significant difference in the low-pass filter of Fz, and the amplitude had a significant difference in the low-pass filter of Pz. Conclusion : The results of this study showed that the less than 0.3 Hz high filters had no effects on the differences between the latency and amplitude of the P300 event-related potential in the working memory. The 30Hz low-pass filter, however, was found to be useful for recording the P300 event-related potential in the working memory.
This paper deals with the performance analysis of the jamming effect of cross-eye when the difference between the real amplitude ratio and the nominal amplitude ratio due to mechanical defects is modeled as a random variable with a normal distribution. We propose how to evaluate mean square difference (MSD) obtained using a numerical integration-based approach. The MSD obtained by the proposed method is closer to non-approximated Monte-Carlo simulation-based MSD than the analytic MSD calculated using the first-order Taylor approximation and the second-order Taylor approximation. It is shown that, based on the numerical integration, the effect of amplitude ratio perturbation on the cross-eye jamming performance can be evaluated without going through the computationally intensive Monte-Carlo method.
We investigate the sunspot area data spanning from solar cycles 1 (March 1755) to 23 (December 2010) in time domain. For this purpose, we employ the Hilbert transform analysis method, which is used in the field of information theory. One of the most important advantages of this method is that it enables the simultaneous study of associations between the amplitude and the phase in various timescales. In this pilot study, we adopt the alternating sunspot area as a function of time, known as Bracewell transformation. We first calculate the instantaneous amplitude and the instantaneous phase. As a result, we confirm a ~22-year periodic behavior in the instantaneous amplitude. We also find that a behavior of the instantaneous amplitude with longer periodicities than the ~22-year periodicity can also be seen, though it is not as straightforward as the obvious ~22-year periodic behavior revealed by the method currently proposed. In addition to these, we note that the phase difference apparently correlates with the instantaneous amplitude. On the other hand, however, we cannot see any obvious association of the instantaneous frequency and the instantaneous amplitude. We conclude by briefly discussing the current status of development of an algorithm for the solar activity forecast based on the method presented, as this work is a part of that larger project.
Kim, Hee-Sung;Seo, Mi-Sun;Shin, Ji-Young;Kim, Kee-Ho
Speech Sciences
/
v.12
no.3
/
pp.175-183
/
2005
In this study, realization of strong and weak syllables in English by Korean leaners with low English proficiency was examined through experiment. The aspects of three acoustic characteristics-duration, pitch, amplitude-were measured and compared with native speakers of English. It was assumed that production of duration, pitch and amplitude of strong and weak syllable by Korean learners would be different from that of English native speakers. According to the production experiments, English native speakers produced strong syllable longer, higher and louder than weak syllable. However, Korean leaners produced strong syllable higher and louder than weak syllable, but not longer enough. Specifically, weak syllable by Korean leaners was longer and strong syllable shorter than native speakers. Furthermore, the difference in duration of syllables between Korean leaners and English native speakers is more significant than pitch and amplitude. As a result, the duration was more important cue for the realization of stress than pitch and amplitude. However, Korean leaners did not produce duration of stressed syllables as English native speakers did, even though they produce the pitch and amplitude of stressed syllable in a similar way to native speakers. The reasons for those were considered, too.
Proceedings of the Korea Electromagnetic Engineering Society Conference
/
2005.11a
/
pp.13-16
/
2005
Many mobile communication systems require bandpass filter with sharp skirt characteristics and consequently a filter was formed by more order. It needs to improve flatness in passband. In this paper, amplitude equalizer was used to improve the flatness of passband. We modified Chebyshev prototype filter by use of network synthesis and computed the prototype elements for Shaping filter. We designed and realized a 13-order combline bandpass filter and 4-order amplitude equalizer with coaxial dielectric resonators at WiBro band. The measured results show $\pm$0.82 dB amplitude difference in passband, 6 dB improved flatness.
We present a ring hybrid balun with additional two ${\lambda}/4$ short stubs that offers excellent amplitude and phase balance performance. The phase difference which is essentially occurred in $180^{\circ}$ ring hybrid is compensated by a ${\lambda}/4$ short stub in one output port. To compensate the amplitude imbalance inherent in the ring hybrid, the series resistance will be added to the second stub which is connected to another output port. The measured balun shows that phase imbalance is less than $2.5^{\circ}$ and magnitude imbalance is less than 0.2dB over a 1.75-2.25 GHz.
Objective: The aim of this study is to evaluate the fluctuation of signal amplitude during repetitive dynamic contraction based on surface electromyography(EMG). Background: The most previous studies were considered isometric muscle contraction and they were difference to smoothing window length by moving average filter. In practical, the human movement is dynamic state. Dynamic EMG signal which indicated as the nonstationary pattern should be analyzed differently compared with the static EMG signal. Method: Ten male subjects participated in this experiment, and EMG signal was recorded by biceps brachii, anterior/posterior deltoid, and upper/lower trapezius muscles. The subject was performed to repetitive right horizontal lifting task during ten cycles. This study was considered three independent variables(muscle, amplitude processing technique, and smoothing window length) as the within-subject experimental design. This study was estimated muscular activation by means of the linear envelope technique(LE). The dependent variable was set coefficient of variation(CV) of LE for each cycle. Results: The ANOVA results showed that the main and interaction effects between the amplitude processing technique and smoothing window length were significant difference. The CV value of peak LE was higher than mean LE. According to increase the smoothing window length, this study shows that the CV trend of peak LE was decreased. However, the CV of mean LE was analyzed constant fluctuation trend regardless of the smoothing window length. Conclusion: Based on these results, we expected that using the mean LE and 300ms window length increased reproducibility and signal noise ratio during repetitive dynamic muscle contraction. Application: These results can be used to provide fundamental information for repetitive dynamic EMG signal processing.
Ocal, F Ceyda Akin;Karacayli, Ceren;Coban, Volkan Kenan;Satar, Bulent
Journal of Audiology & Otology
/
v.25
no.2
/
pp.98-103
/
2021
Background and Objectives: The aim of the study was to compare effects of tone-burst (TB) and narrow-band (NB) Claus Elberling (CE)-chirp stimuli on amplitude, latency and interaural asymmetry ratio (IAR) of cervical vestibular evoked myogenic potentials (cVEMP) in healthy individuals. Subjects and Methods: The study included 50 healthy volunteers. cVEMP procedure was carried out using 500 Hz TB and NB-CE-chirp stimulus (360-720 Hz, up-chirp) in random order. cVEMP were recorded at 100 dB nHL. For each ear and each stimulus, P1 latency, N1 latency and P1N1 amplitude were measured. IAR was also calculated. Results: Mean age was 26.66±9.48 years. cVEMP's in response to both TB and NB CE-chirp stimuli were obtained in all subjects. No statistically significant difference in P1 latency, N1 latency, and P1N1 amplitude was found between the right and left ears for both TB and NB CE-chirp stimuli (p>0.05). In both sides, P1 and N1 latencies were significantly shorter in NB CE-chirp stimulation compared to TB stimulation (p=0.000). In both sides, no statistically significant difference was found in P1N1 amplitude between two types of stimuli (p>0.05). Conclusions: The chirp stimulus produces robust but earlier cVEMP than TB does. This largest series study on NB chirp cVEMP shows that NB chirp is a good and new reliable alternative.
Ocal, F Ceyda Akin;Karacayli, Ceren;Coban, Volkan Kenan;Satar, Bulent
Korean Journal of Audiology
/
v.25
no.2
/
pp.98-103
/
2021
Background and Objectives: The aim of the study was to compare effects of tone-burst (TB) and narrow-band (NB) Claus Elberling (CE)-chirp stimuli on amplitude, latency and interaural asymmetry ratio (IAR) of cervical vestibular evoked myogenic potentials (cVEMP) in healthy individuals. Subjects and Methods: The study included 50 healthy volunteers. cVEMP procedure was carried out using 500 Hz TB and NB-CE-chirp stimulus (360-720 Hz, up-chirp) in random order. cVEMP were recorded at 100 dB nHL. For each ear and each stimulus, P1 latency, N1 latency and P1N1 amplitude were measured. IAR was also calculated. Results: Mean age was 26.66±9.48 years. cVEMP's in response to both TB and NB CE-chirp stimuli were obtained in all subjects. No statistically significant difference in P1 latency, N1 latency, and P1N1 amplitude was found between the right and left ears for both TB and NB CE-chirp stimuli (p>0.05). In both sides, P1 and N1 latencies were significantly shorter in NB CE-chirp stimulation compared to TB stimulation (p=0.000). In both sides, no statistically significant difference was found in P1N1 amplitude between two types of stimuli (p>0.05). Conclusions: The chirp stimulus produces robust but earlier cVEMP than TB does. This largest series study on NB chirp cVEMP shows that NB chirp is a good and new reliable alternative.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.