• Title/Summary/Keyword: amplification factor

Search Result 292, Processing Time 0.02 seconds

Study of modified Westergaard formula based on dynamic model test on shaking table

  • Wang, Mingming;Yang, Yi;Xiao, Weirong
    • Structural Engineering and Mechanics
    • /
    • v.64 no.5
    • /
    • pp.661-670
    • /
    • 2017
  • The dynamic model test of dam-reservoir coupling system for a 203m high gravity dam is performed to investigate effects of reservoir water on dynamic responses of dam during earthquake. The hydrodynamic pressure under condition of full reservoir, natural frequencies and acceleration amplification factors along the dam height under conditions of full and empty reservoir are obtained from the test. The results indicate that the reservoir water have a stronger influence on the dynamic responses of dam. The measured natural frequency of the dam model under full reservoir is 21.7% lower than that of empty reservoir, and the acceleration amplification factor at dam crest under full reservoir is 18% larger than that under empty reservoir. Seismic dynamic analysis of the gravity dams with five different heights is performed with the Fluid-Structure Coupling Model (FSCM). The hydrodynamic pressures from Westergaard formula are overestimated in the lower part of the dam body and underestimated in its upper part to compare with those from the FSCM. The underestimation and overestimation are more significance with the increase of the dam height. The position of the maximum hydrodynamic pressure from the FSCM is raised with the increase of dam height. In view of the above, the Westergaard formula is modified with consideration in the influence of the height of dam, the elasticity of dam on the hydrodynamic pressure. The solutions of modified Westergaard formula are quite coincident with the hydrodynamic pressures in the model test and the previous report.

Performance Evaluation of Seawater-Exchanging Breakwater Using Helmholtz Resonator (헤름홀츠 공명장치를 이용한 해수교환형 방파제의 성능평가)

  • 조일형
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.13 no.2
    • /
    • pp.89-99
    • /
    • 2001
  • In the present paper, Helmholtz resonator, which is widely used as a sound-amplification device, is applied to the development of seawater-exchanging breakwater. The incident waves can induce a large response in the resonator when incident wave frequency is close to one of natural modes of the resonator. Largely amplified potential energy due to the resonance supplies clean seawater into the harbor side throughout the channel. Flow supplied by the resonator circulates the seawater of harbor and helps to improve water quality. Within the framework of linear potential theory, matched asymptotic expansion method is employed to analyze the wave responses in a resonator. The semi-circular shape of the resonator has been chosen as an analytic model for mathematical simplicity. The wave responses of both single and arrays of Helmholtz resonator are investi¬gated. To validate an analytic solution, model test is conducted at 2-dimensional wave tanle Wave hcights in the resonator and velocity at the channel are measured for the state of valve-on and valve-off.

  • PDF

Four-pass dye laser amplifier for the direct pulsed amplification of a tunable narrow-bandwidth continuous-wave laser (좁은 선폭을 갖는 파장가변 연속파 레이저의 펄스형 증폭을 위한 사중경로 색소 레이저 증폭기)

  • 이재용;이해웅;유용심;한재원
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.2
    • /
    • pp.162-168
    • /
    • 1999
  • A new design of four-pass dye laser amplifier affording a narrow-bandwidth pulsed output is demonstrated to suppress the amplified spontaneous emission(ASE) carried by the amplifier output and reduce the possibility of parasitic oscillation in the amplifier. By the direct pulsed amplification of a cw 100 mW dye laser under a Q-switched doubled Nd:YAG laser pumping with energy of 5.6 mJ/pulse, high-peak-power pulsed output with 1.5-mJ energy in 130-MHz bandwidth is obtained corresponding to a power gain greater than $2{\times}10^6$ and an energy efficiency of 27%. The ASE ratio in the four-pass amplifier output is dramatically reduced by using a diffraction grating in the amplifier. Compared with the results obtained from the normal operation of the amplifier with no frequency-selective device, the ASE ratio is reduced by a factor in excess of 10 to remain under 1.5% of the amplifier output whereas the total output energy is slightly increased by ~4%.

  • PDF

3D Dynamic Finite Element Analysis and Corresponding Vibration of Asphalt Track Considering Material Characteristics and Design Thickness of Asphalt Concrete Roadbed Under Moving Load (아스팔트 콘크리트 설계두께 및 재료특성을 반영한 아스팔트 콘크리트 궤도 3차원 이동하중 동적해석 및 진동특성)

  • Lee, SeongHyeok;Seo, HyunSu;Jung, WooYoung
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.1
    • /
    • pp.67-76
    • /
    • 2016
  • The asphalt-concrete trackbed system has many advantages in terms of maintenance and economics. However, methods to investigate practical use corresponding to the development of the trackbed system must be developed. The primary objective of this study was to evaluate the dynamic performance of the asphalt system in accordance with both the elastic and viscoelastic material characteristics and design thickness of the asphalt trackbed. More specifically, in order to reduce the uncertainty error of the Finite Element(FE) model, a three-dimensional full scale FE model was developed and then the infinite foundation model was considered. Finally, to compare the condition of viscoelastic materials, performance evaluation of the asphalt-concrete trackbed system was used to deal with the dynamic amplification factors; numerical results using isotropic-elastic materials in the FE analysis are presented.

Evaluation of Earthquake Ground Motion Considering Dynamic Site Characteristics in Korea (국내 지반특성에 적합한 설계지반운동 결정 방법에 대한 연구)

  • Yoon, Jong-Ku;Kim, Dong-Soo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.3
    • /
    • pp.23-32
    • /
    • 2004
  • The local geologic and dynamic site characteristics, which include soil profiles, shear wave velocity profiles and depths to the bed rock were gathered from 148 sites all over the Korean peninsula and those values are compared to those in the western USA. Site response analyses were performed based on equivalent linear scheme using design rock-outcrop acceleration of 0.154g which corresponds to the collapse level of earthquake for seismic category I structure. The results show that the amplification factor based on Korean seismic design guideline underestimates the motion in short-period range and overestimates the motion in mid-period range. It is suggested that the existing Korean seismic guideline based on UBC is required to be modified considering dynamic site characteristics in Korea for the reliable estimation of site amplification.

Shaking table tests on the seismic response of slopes to near-fault ground motion

  • Zhu, Chongqiang;Cheng, Hualin;Bao, Yangjuan;Chen, Zhiyi;Huang, Yu
    • Geomechanics and Engineering
    • /
    • v.29 no.2
    • /
    • pp.133-143
    • /
    • 2022
  • The catastrophic earthquake-induced failure of slopes concentrically distributed at near-fault area, which indicated the special features of near-fault ground motions, i.e. horizontal pulse-like motion and large vertical component, should have great effect on these geo-disasters. We performed shaking table tests to investigate the effect of both horizontal pulse-like motion and vertical component on dynamic response of slope. Both unidirectional (i.e., horizontal or vertical motions) and bidirectional (i.e., horizontal and vertical components) motions are applied to soft rock slope model, and acceleration at different locations is reordered. The results show that the horizontal acceleration amplification factor (AAF) increases with height. Moreover, the horizontal AAF under unidirectional horizontal pulse-like excitations is larger than that subject to ordinary motion. The vertical AAF does not show an elevation amplification effect. The seismic response of slope under different bidirectional excitations is also different: (1) The horizontal AAF is roughly constant under horizontal pulse-like excitations with and without vertical waves, but (2) the horizontal AAF under ordinary bidirectional ground motions is larger than that under unidirectional ordinary motion. Above phenomena indicate that vertical component has limited effect on seismic response when the horizontal component is pulse-like ground motion, but it can greatly enhance seismic response of slope under ordinary horizontal motion. Moreover, the vertical AAF is enhanced by horizontal motion in both horizontal pulse-like and ordinary motion. Thence, we should pay enough attention to vertical ground motion, especially its horizontal component is ordinary ground motion.

Resolving data imbalance through differentiated anomaly data processing based on verification data (검증데이터 기반의 차별화된 이상데이터 처리를 통한 데이터 불균형 해소 방법)

  • Hwang, Chulhyun
    • Journal of Intelligence and Information Systems
    • /
    • v.28 no.4
    • /
    • pp.179-190
    • /
    • 2022
  • Data imbalance refers to a phenomenon in which the number of data in one category is too large or too small compared to another category. Due to this, it has been raised as a major factor that deteriorates performance in machine learning that utilizes classification algorithms. In order to solve the data imbalance problem, various ovrsampling methods for amplifying prime number distribution data have been proposed. Among them, SMOTE is the most representative method. In order to maximize the amplification effect of minority distribution data, various methods have emerged that remove noise included in data (SMOTE-IPF) or enhance only border lines (Borderline SMOTE). This paper proposes a method to ultimately improve classification performance by improving the processing method for anomaly data in the traditional SMOTE method that amplifies minority classification data. The proposed method consistently presented relatively high classification performance compared to the existing methods through experiments.

The Influence of the Application Methods of Direct Analysis Method for the Evaluation of Frame Stability (골조 안정성 평가를 위한 직접해석법의 적용 방법에 따른 영향)

  • Kim, Hee-Dong
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.4
    • /
    • pp.293-303
    • /
    • 2010
  • The purpose of this study was to evaluate the influence of the methods of application of the direct analysis method, using the load amplification factor suggested by the KBC 2009 design code, for the evaluation of frame stability. For this purpose, the direct analysis method was performed for three-story-one-bay and five-story-three-bay unbraced steel frames with various notional loads, bending stiffness reductions, and factor B2s. The results of the analyses were compared with the results of the second-order inelastic analysis to evaluate the influence of the applied methods. The scale of the frame, the axial load ratio, and the axial load distribution pattern were added to the main parameters to investigate the external effects. The research results showed that the influence of the methods of application of the direct analysis method is not significant in the case of the required axial strength and the application of the additional notional loads; and that the application of the factor B2 with the story stiffness concept to the direct analysis method is appropriate for the required flexural strength.

Optimal Cylindrical Capacitive Sensor(CCS) taking into account the Circumferential Gaps between Sensor Electrodes (센서 전극 사이의 간극을 고려한 최적의 정전용량 센서)

  • Ahn, Hyeong-Joon;Park, Jong-Min;Han, Dong-Chul
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.613-618
    • /
    • 2004
  • CCS was developed and applied to rotating machines because of accurately measuring the spindle error motion without significant efforts. However, researches on the CCS have been focused on ideal cases where circumferential gaps were ignored. This paper presents the effects of circumferential gaps and proposes an optimal CCS considering the circumferential gaps. First, electrostatic analysis of the CCS that includes the circumferential gaps is performed using the FEM, and an additional capacitance due to the circumferential gap can be approximated as an equivalent extended sensor length. Second, a mathematical model of the CCS considering the circumferential gaps is derived, and the optimal CCS is determined through minimization of the weighted error amplification factor. Finally, two CCSs, both considering and ignoring the circumferential gaps, are built, and the effectiveness of the optimal design is verified through simulation and experiment.

  • PDF

Wave Interaction with a Porous Circular Cylinder of Non-Uniform Porosity (비 균일한 공극율을 갖는 투과성 원기둥과 파의 상호작용)

  • Cho, Il-Hyoung
    • Journal of Ocean Engineering and Technology
    • /
    • v.23 no.6
    • /
    • pp.23-31
    • /
    • 2009
  • The interaction of incident monochromatic waves with a bottom-mounted vertical porous circular cylinder is investigated using the framework of the three-dimensional linear potential theory. The porosity of the circular cylinder is uniform vertically but varies in the circumferential direction. By adjusting the porosities of the circular cylinder, both the wave blocking performance of a porous semi-circular breakwater and the wave responses inside a circular harbor with an entrance are applied as calculation examples. It is found that the reflected waves, wave run-up, and wave forces are significantly reduced due to wall porosity, which are positive factors for a breakwater, and the amplification factor of a circular harbor at resonant frequencies is greatly reduced by a porous sidewall.