• Title/Summary/Keyword: amperage

Search Result 12, Processing Time 0.027 seconds

Clinical Study of Acupuncture Effect by Measuring Amperage from Chong points (정혈(井穴)의 도전량(導電量) 측정에 의한 무자(繆刺) 및 거자법(巨刺法)의 유용성에 관한 임상 고찰)

  • Ahn, Kyu-Beom;Wang, Wu-Hao;Lim, Jin-Kang;Jang, Hyoung-Seok
    • Journal of Acupuncture Research
    • /
    • v.18 no.4
    • /
    • pp.13-21
    • /
    • 2001
  • Objective : This study is performed to evaluate the clinical effect of acupuncture to acu-points in the normal side by means of amperage measured from chong points. Methods : Among the outpatients with ankle sprain who visited to Department of Acupuncture & Maxibustion, Jaseng oriental medicine hospital from 21, December 2000 to 10, February 2001, we selected 11 persons who showed normal finding in the X-ray. They were divided into two groups. One group was treated with acupuncture to acu-points in the painful side and the other was treated with acupuncture to acu-points in the normal side. Before and after acupuncture, we measured the amperage from their chong points. We selected 10 persons who we thought they were healthy as a control group. We also measured the amperage from their chong points. Results : Between the control and the ankle sprain group, there were significant differences of differences between the amperages of Rt. chong point and Lt. thong point of the same name. Between the group treated with acupuncture to acu-points in the painful side and the group treated with acupuncture to acu-points in the normal side, there were no significant differences of differences between the amperages of Rt. chong point and Lt. chong point of the same name. Conclusion : This result indicated that the acupuncture to acu-points in the painful side was not less effective than the acupuncture to acu-points in the normal side, and so the more study is needed continuously.

  • PDF

Selective Sterilization of Vibro parahaemolyticus from a Bacterial Mixture by Low-Amperage Electric Current

  • Jin, Soo-Chang;Yoo, Hyun-Suk;Woo, Yeon-I.;Lee, Mi-Hee;Vagaska, Barbora;Kim, Jung-Sung;Uzawa, Masakazu;Park, Jong-Chul
    • Journal of Microbiology and Biotechnology
    • /
    • v.19 no.6
    • /
    • pp.537-541
    • /
    • 2009
  • The objective of this study was to investigate the possibility of using low-amperage electrical treatment (LAET) as a selective bacteriocide. Mixtures containing Escherichia coli, Staphylococcus aureus, and Vibrio parahaemolyticus were treated with different electric current intensities and for different times. The results showed that at 263 mA, treating bacteria for 100 ms eliminated all V. parahaemolyticus colonies. Although LAET reduced the populations of the three microorganisms, V. parahaemolyticus was more injured by LAET than S. aureus and E. coli when treated at the same processing conditions.

Distribution Automation Switch Testing Software Development (배전자동화용 개폐기 시험용 소프트웨어 개발)

  • Ok, Ki-Jung;Kim, Jae-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.446-448
    • /
    • 2001
  • We have developed the testing software for KEPCO operators to maintain the small-scale distribution automation system effectively. The testing software is used to monitor the present status, to measure the analog value(voltage, amperage) and to control the switch and FRTU(Feeder Remote Terminal Unit) in order to find out a disabled part of the system. And at the stage of inspection of the switch and FRTU, it can screen the inferior one.

  • PDF

The Characteristics Analysis of The PCB Pattern for The Mobile panel Power Supply on The PMIC (모바일 패널 전원 공급을 위한 PMIC의 PCB 패턴의 특성 분석)

  • Chung, Sung-In;Kim, Seo-Hyeong
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.6
    • /
    • pp.39-44
    • /
    • 2011
  • This purpose of this study is to propose the characteristics analysis of the PCB pattern designed two modes for the output voltage value on the PMIC through converting the limited voltage value inputted from a battery. The PCB design technology has been undergoing difficulty in getting the related technology in a domestic market because of increasing EMI/EMC, Cross-talk, Impedance. And it requires to have the appropriate clearance between the patterns and the technology of PCB pattern width with a amperage according to various uses. The study carried out the characteristics analysis of the PCB pattern designed from a direct output method without a capacitor[mode1], to an output method through a capacitor[mode2] for PMIC output voltage value. Besides, we calculated the pattern width with a amperage using the equation suggested by IPC-2221, presenting the right way of the layout design to analyze the trouble with the test. Therefore, this study is expected to contribute not only to applying the PMIC design for the mobile panel power supply, but also helping the design and application technology in various areas such as car control, camera, note-book, computer, PDA, etc.

A Study on the Combustion of the Ferrosilicon-Minium Delay Powders (지연화학의 연소에 관한 연구)

  • 김용욱;강원만
    • Journal of the Korean Society of Safety
    • /
    • v.1 no.1
    • /
    • pp.33-40
    • /
    • 1986
  • The results from a study on the combustion of the ferrosilicon-miniun delay powder which was examined under the various conditions are as follows. 1. It has been found that in case of these delay powders, decomposition of oxidiging agents occurs first and then reducing agents are oxidized by the gases evolved from the oxidizing agents and by the oxygen in air. Therefore, the main reactions are heterogenous reaction and especially He gas phase plays an important role in combustion reactions of delay Powders. 2. In case the loading pressure is below 100kg per a detonator, the dispresion of burning time is large. 3. Little or no increase in humidity was observed on daily measurement during six month preservation tests. 4. The amperage of electric current for igniting the fuse head has no effect on the burning time of delay conposition itself changed in the detonator.

  • PDF

Phase Shift Analysis and Phase Identification for Distribution System with 3-Phase Unbalanced Constant Current Loads

  • Byun, Hee-Jung;Shon, Sugoog
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.4
    • /
    • pp.729-736
    • /
    • 2013
  • Power grids are large complicated networks in use around. An absolute phase value for a particular unknown-phase line at a local site should be identified for the operation and management of a 3-phase distribution network. The phase shift for a specific point in the line, as compared with a phase reference point at a substation, must be within a range of ${\pm}60^{\circ}$ for correct identification. However, the phase shift at a particular point can fluctuate depending on the line constants, transformer wiring method, line length, and line amperage, etc. Conducted in this study is a theoretical formulation for the determination of phase at a specific point in the line, Simulink modeling, and analysis for a distribution network. In particular, through evaluating the effects of unbalanced current loads, the limitations of the present phase identification methods are described.

A Study on the Analysis and Limitations of the Same Phase Identification Under 3-Phase Unbalanced Constant Current Loads (3상 불평형 정전류 부하 조건에서의 동 위상 판별에 대한 분석 및 한계에 관한 연구)

  • Byun, Hee-Jung;Shon, Su-Goog
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.6
    • /
    • pp.38-46
    • /
    • 2012
  • In this paper, the necessity for the identification of the absolute phase value is introduced and analyzed for a particular conductor line of a 3-phase type distribution network and the recent methods are also introduced. For the determination of the exact phase value for a specific point in the line, as compared with the phase reference point, the measured phase value must be within a range of ${\pm}60[^{\circ}]$. However, the phase of a particular point can fluctuate depending on the line constant, transformer wiring method, line length, line amperage, etc. A theoretical formulation such as Simulink modeling and analysis for a distribution network are conducted for the identification of phase at a specific point in the line. In particular, through evaluating the effects of unbalanced current loads at the time of determination of the phase value, the limitations of the present method for the determination of phases is described.

Inhibition of Bacterial Growth with Silver Wire Iontophoresis (은 이온도입이 세균성장에 미치는 영향)

  • Lee Jae-Hyoung;Kim Joo-Young;Jekal Seung-Joo
    • The Journal of Korean Physical Therapy
    • /
    • v.7 no.1
    • /
    • pp.61-67
    • /
    • 1995
  • The silver cation has broad-spectrum antibiotic activity toward Gram-positive, Gram-negative, fungal. aerobic and anerobic micro-organisms. Silver has been used to care of infected wound. pyogenic arthritis, and chronic osteomyelitis. The purpose of this study was to determine whether pure silver wire iontophoresis using milliamperage direct current has an inhibitory effect on growth in vitro of 3 different species of bacteria-Staphylococcus aureus, Escherichia coli, and Pseudomonas aeruginosa. Using agarose based media, silver iontophoresis performed at 0, 1, 2, 4, 8 mA for 15 minutes. All experiments were performed in triplicate. Following iontophoresis, inhibition zone width of bacterial growth was measured with calliper. The inhibition of bacterial growth occured at the anodal silver electrode. Inhibition zone width of bacterial growth was significantly increased in all three bacterial species (p<0.05). Between bacterial species, inhibition zone width was not significantly different. Inhibition gone and amperage showed a highly significant positive linear relationship (p<0.001). The result of this study showed that pure silver wire iontophoresis with milliamperage direct current, as well as microamperage direct current, can inhibit bacterial growth in vivo.

  • PDF

Development of Coaxial Propeller Test Facility and Experimental Study on Hover Performance Characteristics for Drone (드론용 동축 프로펠러 시험장치 개발 및 제자리비행 성능특성에 대한 실험적 연구)

  • Song, Youn-Ha;Kim, Deog-Kwan
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.1
    • /
    • pp.59-67
    • /
    • 2018
  • In this paper, the test facility for coaxial propellers at low Reynolds developed and validated by measured data. The test equipment was designed to measure the hovering performance of propellers according to distances between the upper/lower propellers. Thrust, torque, rotational speed, vibration, and amperage of upper and lower propellers can be measured separately. The data acquisition system was built to collect signals of sensors, and LabVIEW software was used to control the motor and collect the signal. The hover performance tests of single propellers were preceded for the facility validation, and then the performance values of coaxial propellers were measured according to distances and diameter differences between the upper/lower propellers. The results showed that the high efficiency is achieved at 20%~30% distance between the upper propeller and lower one. The configuration that the upper propeller has shorter diameter than the lower one has the highest efficiency than other configuration.

Study of the Tracking Fire Risk by Dust Resistivity of Pens (축사별 먼지 저항률에 따른 트래킹화재 위험성에 관한 연구)

  • Park, Kwang-Muk;Bang, Sun-Bae;Kim, Jae-Hyun;Park, Jin-Yeong
    • Fire Science and Engineering
    • /
    • v.30 no.6
    • /
    • pp.99-104
    • /
    • 2016
  • In animal and plant facilities, dust samples were collected from cattle sheds, pigsties and hen-houses, which have high proportion of electrical fires. The samples were diluted in distilled water and water resistivity was measured. Current measurements and tracking reappearance experiments were conducted using distilled water with dust samples. The analysis results were obtained to track the fire risks according to the dust resistivity. The highest value was the dust from cattle sheds followed in order by the dust of pigsties and hen-houses. In experiments measuring the temperature change and RMS current, the lower resistivity of water showed a significant trend of temperature and high amperage. In the tracking reappearance experiment with the lower resistivity water, the tracking speed was fast and the ignition time was shortened. This study investigated why each dust resistivity shows different results.