• Title/Summary/Keyword: amount of water

Search Result 7,117, Processing Time 0.036 seconds

Estimation of Pollution Load in Anyang Stream Basin Using GIS (GIS를 이용한 안양천 유역의 오염부하량 산정)

  • 최종욱;유병태;이민환;김건흥
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.3
    • /
    • pp.1-9
    • /
    • 1999
  • In the estimation of pollution load in water basin, a data information has generally used from surveyed data. A Geographic Information System(GIS) was adopted to evaluate the amount of pollution load in Anyang stream basin which is one of the major tributaries in the Han river flows through urban area. The digital maps of administrative boundary, stream network, sub-basin, soil type, and land-use for spatial data as well as attribute data were generated. And the database of sub-basins and pollution source was structured to estimate pollution load in Anyang stream basin by an Arc/Info GIS.As the results of this investigation, the pollution load of Mokgam-chun sub-basin was the highest amount. And that of Hagi-chun sub-basin and the fourth main stream sub-basin were also high amount in Anyang stream basin. In general, it was found that the pollution load generated from the upstream area in Kyunggi province was higher than that from downstream area in Seoul. Because the point and non-point source pollution load played very significant role in the deterioration of the water quality of the Anyang stream, an integrated approach to water quality management should be required for the sub-basins of high pollution load amount.

  • PDF

The effect of the temperature of rinsing water after brushing on oral malodor (잇솔질 후 양칫물 온도가 구취에 미치는 영향)

  • Chol, Woo-Yang;Kim, Hyun-Sook
    • Journal of Korean society of Dental Hygiene
    • /
    • v.12 no.3
    • /
    • pp.465-470
    • /
    • 2012
  • Objectives : In general, the active of volatile compounds which become usually known as the principal ingredient of bad breath is closely connected with temperature. In this study, an investigation was made into the correlation between oral malodor and the temperature of rinsing water. Specifically, an analysis was made of saliva in rinsing water with relation to amount, flow and pH. In addition, a calculation was made of O'Leary index. The results are expected to be basic data for oral malodor reduction plans. Methods : A total of 30 women who are in their 20s without any systemic disease and teeth braces and non-pregnant were chosen for the study. The research was carried during 3 weeks from 28 Mar to 11 Apr in 2011. Results : Saliva was not significantly affected by the temperature of rinsing water, in connection with saliva amount, saliva flow and saliva pH. The O'Leary index and oral malodor was the highest in warm water, but the subjects preferred rinsing with cold water. Conclusions : In conclusion, oral malodor was found to be reduced in inverse proportion to the temperature of rinsing water. Thus, it is recommended to rinsing water with warm water after tooth brushing.

Experimental Study on the Performance of a CO2 Heat Pump Water Heater under Various Operating Conditions (이산화탄소 급탕 열펌프의 운전조건에 따른 성능 특성에 관한 실험적 연구)

  • Sohn, Dong-Jin;Baek, Chang-Hyun;Heo, Jae-Hyeok;Kang, Hoon;Kim, Yong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.4
    • /
    • pp.273-280
    • /
    • 2011
  • In this study, the steady state performance of a $CO_2$ heat pump water heater was measured with a variation of operating conditions such as refrigerant charge amount, compressor frequency, EEV opening, and water mass flow rate. Transient state performance tests were also conducted to investigate major system effects associated with the interaction between the $CO_2$ heat pump water heater and the water tank. Optimum refrigerant charge amount for the system was 1600 g. At compressor frequencies of 50 Hz and 60 Hz, water mass flow rates of 95 kg/h and 105 kg/h, and EEV opening of 8% and 16%, the water heating temperatures were $65^{\circ}C$ and $68^{\circ}C$ and COPs were 3.0 and 2.8, respectively. In the transient condition, the instantaneous COP decreased with an increase in the inlet water temperature.

Self-Diffusion of THO within Tactic Poly(2-hydroxyethyl methacrylate) Membranes

  • Kim, Hye-Kyeong;Jhon, Mu-Shik
    • Bulletin of the Korean Chemical Society
    • /
    • v.4 no.3
    • /
    • pp.128-132
    • /
    • 1983
  • The self-diffusion experiment of water was performed across two series of tactic poly(2-hydroxyethyl methacrylate), P(HEMA) membranes prepared by crosslinking with various amount of hexamethylene diisocyanate (HMDIC). The tagging material was tritium hydroxide (THO) and the efflux of THO was counted on a Liquid Scintillation Counter. The transport data of THO show that the permeability decreases as the amount of HMDIC increased from 2.5 to 10 mole % and the self-diffusions coefficient shows a parallel trend with it. The diffusivity data was discussed in terms of the change of water structural orderliness within membranes. Using the relation between viscosities and diffusivities derived from Eyring's absolute rate theory, the corresponding viscosities of water within two series of tactic P(HEMA) membranes were obtained. From this, it is seen that the viscosity of water within tactic P(HEMA) membranes may have the same values with those of supercooling water whose temperature ranges from -28 to -$36^{\circ}C.$.

A Practical Research for More Efficient Utilization of Water Resources in the South-Western Part of Korea (서남부지역 수자원의 효율적 이용방안)

  • 김현영;서영제;최용선;문종원
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.279-286
    • /
    • 1998
  • The south-western part of Korea is situated in an unbalance of water supply and demand relating to the Keum, Mankyung, Dongjin and Youngsan River and their estuary reservoirs. For example, the Keum River estuary reservoir is discharging the larger amount of yearly runoff into the sea due to the small storage capacity, while Saemankeum estuary reservoir which is under construction, has the smaller runoff amount comparing with its storage capacity, And the downstream area of the Youngsan River, such as Youngkwang, Youngam are deficient in water due in larger demand and smaller supply. In order to solve the above unbalanced water supply and demand and also to improve the water use efficiency, the Hierarchical Operation Model for Multi-reservoir System(HOMMS) has been developed and applied to analyze the multi-reservoir operation assuming that the above reservoirs were linked each other. The result of this study shows that 2,148MCM of annual additional water requirement for agricultural and rural water demands are required in this region at 2011 of target year, and these demands can be resolved by diverting and reusing 1,913MCM of the released water from the estuary reservoirs into the sea.

  • PDF

Study on Ice Making Behavior of Water Solution with Surfactant (계면활성제 첨가수용액의 제빙에 관한 기초연구)

  • ;Hideo Inaba;Akihiko horibe
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.12
    • /
    • pp.1175-1183
    • /
    • 2001
  • Recently, a great attention has been paid to the ice thermal storage system for the purpose of energy saving and reduction in peak electrical demand. In the present study, it has been investigated the freezing behavior of several kinds of water solutions with nonionic surfactant. In order to prevent ice blockage in a cooled pipe, the amount and wall adhesion behavior of ice of the test fluids were observed experimentally under different concentration of water solution with surfactant, temperature of cooled wall, and the shear velocity of test fluids. The results showed that the size of ice crystal became smaller at higher shear velocity at wall. And the lowest limit of wall adhesion of ice in water solution with surfactant was found at 230 W/$m^2$ of heat flux.

  • PDF

A Fundamental Study on the Waste Polyethylene Chips Mixed with Soil (폐비닐 골재 혼합토의 기본 성질에 관한 연구)

  • 김영진;김현민
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.03b
    • /
    • pp.548-555
    • /
    • 2000
  • It was investigated whether the waste polyethylene chips can be recycled as construction materials in geotechnical engineering field. The standard Proctor test, the hydraulic conductivity test, the large box direct shear test, the thermal conductivity test, the frost heaving test and the time domain reflectometry test were performed on weathered granite soil mixed with variable amount of the waste polyethylene chips. The experimental results showed that the hydraulic conductivity and the shear strength of weathered granite soil increase with increasing the amount of the waste polyethylene chips. On the other hand, the thermal conductivity, the amount of frost heaving and the unfrozen water contents of weathered granite soil decrease with increasing the amount of the waste polyethylene chips.

  • PDF

A Study on the Efficient Applicability of Fenton Oxidation for the Wastewater Containing Non-biodegradable Organics (생물난분해성 유기물질 함유 폐수처리를 위한 Fenton 산화법의 효율적 적용방안에 관한 연구)

  • Jun, Se Jin;Kim, Mi Jeong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.14 no.1
    • /
    • pp.76-83
    • /
    • 2000
  • This research is about wastewater containing non-biodegradable TDI(Toluene Diisocyanate) that is treated by the activated carbon adsorption method. In the case of the Fenton oxidation process being applied to the existing process, optimal pH, reaction time, chemical dosing amount, removal rate, and cost were investigated. A pilot plant test was applied after finding optimal conditions with lab experiments. The optimal conditions were pH 3~5(COD removal rate 84~88%) and reaction time 30min~1hr. In higher $H_2O_2$ dosing amount, COD removal rate was a little higher. But there was little difference in the removal rate according to $FeSO_4{\cdot}7H_2O$ dosing amount. Treatment cost was economical in the case of the Fenton oxidation process being operated earlier than activated carbon adsorption system. But chemical dosing point, chemical mixing effect, chemical dosing amount, removal rate, and the cost of facility and others must be considered in practical process.

  • PDF

Effects of Jangwon-hwan(Zhuangyuan-wan) Water Extract against Xanthine Oxidase / Hypoxanthine-induced Neurotoxicity in the Cultured Mouse Cerebral Cortical Neurons (장원환이 XO/HX에 의해 손상된 대뇌피질 신경세포에 미치는 영향)

  • 김영수;권강범;민영기;조현익;박준배;이호섭;류도곤
    • The Journal of Korean Medicine
    • /
    • v.20 no.4
    • /
    • pp.3-10
    • /
    • 2000
  • In order to elucidate the toxic mechanism of neurotoxical damage and neuroprotective effect of Jangwon-hwan(Zhuangyuan-wan) water extract, this experiment was performed. Neurotoxic effects of xanthine oxidase/hypoxanthine(XO/HX) were examined by MTT and NR assay, neuroprotective effects of Jangwon-hwan(Zhuangyuan-wan) water extract were examined by neurofilament enzymeimmuno assay(EIA). XO/HX induced an increase in cell viability, and a decrease in the amount of neurofilament on cultured mouse cerebral cortical neurons in dose-dependent manner. In neuroprotective effect of herb medicine, Jangwon-hwan(Zhuangyuan-wan) water extract increased the amount of neurofilament on cultured mouse cerebral cortical neurons damaged by XO/HX. From the results, it is suggested that XO/HX showed toxic effect in cultured mouse cerebral cortical Neurons and Jangwon-hwan(Zhuangyuan-wan) water extract is very effective in the prevention of neurotoxicity induced by XO/HX.

  • PDF

Durable Press Performance and Water Repellency of Cotton/Polyester Fabrics Finished by BMDHEU/Fluorochemicals (DMDHEU/FC 일욕가공된 면/폴리에스테르 혼방직물의 DP성 및 발수성)

  • 권영아
    • Textile Coloration and Finishing
    • /
    • v.10 no.5
    • /
    • pp.24-31
    • /
    • 1998
  • The effects of DMDHEU alone and DMDHEU/Fluorochemical(FC) combined treatment on the physical properties of 75%/25% cotton/polyester(CP) blended fabrics were investigated. FC water repellent and DMDHEU durable press finishes were applied in combination to CP fabrics to provide good water repellency as well as great durable press(DP) performance. The physical properties of the fabrics were evaluated by wrinkle recovery angle(WRA), DP performance, contact angle, demand wettability, and water repellency. The durable press/water repellent finished(DP/WR) CP fabrics show considerably improved WRA and DP performance. The DP/WR finishes do not change the water contact angie of polyester fibers significantly, while the DP finishes increase it. Both DP and DP/WR finishes increase the contact angle of cotton fibers. The water uptake amount increases in the following order : DP/WR cotton, DP/WR CP<DP cotton, DP CP < Control CP, Control cotton. The water uptake amount increases in the following order DP/WR CP, DP/WR cotton <DP cotton <DP CP<Control CP, Control cotton. Considerable improvements for water repellency are imparted to the CP fabrics treated with DP/WR, and the level of improvement is not significantly different from that of the DP/WR cotton fabrics. These results lead to the conclusion that DP/YVR treatments a single pad bath on CP are effective finishes for improving both DP performance and water repellency.

  • PDF