• 제목/요약/키워드: amount of water

검색결과 7,107건 처리시간 0.035초

소량과 다량의 맹물 및 얼음물 섭취가 정상인의 순환에 미치는 영향 (The Effect of Ingesting Small and Large Amount of Tap or Iced Water on Circulation of Normal Men)

  • 최명애;김종임
    • 대한간호학회지
    • /
    • 제17권2호
    • /
    • pp.116-121
    • /
    • 1987
  • This study was undertaken to elucidate effects of ingesting small or large amount of tap or iced water on circulation of normal healthy men with the purpose of furnishing basic data for nursing intervention of myocardial infarction patients. The subjects for this study were normal healthy men consisting of 30men and 30women in age from 22 to 30 years. One group consisting of 30men drank 240m1 tap water on day l and 240m1 iced water 24hours later. The other group drank 960m1 tap water on day 1 and 960m1 iced water 24hours later. Blood pressure and heart rate were taken in a sitting position before ingesting water, and immediately after ingesting it and at 2,5,10,15,30 minute intervals thereafter. Changes of heart rate, systolic and diastolic blood pressure after ingesting water were compared with those of preingestive period. The results obtained were as follows : 1. There were no significant changes in blood pressure and heart rater after ingesting small amount of water regardless of its temperature. 2. No significant decrease in blood pressure after ingesting large amount of tap water at all time peroids was noted. 3. A strongly significant interaction effect bet-ween temperature and volume was demonstrated, that is, there was a highly significant decrease in blood pressure and heart rate at all time periods after ingesting large amount of iced water.

  • PDF

냉매 내 수분의 혼입량이 차량 에어컨의 냉각성능에 미치는 영향 (Effects of Water Amount in Refrigerant on Cooling Performance of Vehicle Air Conditioner)

  • 문성원;민영봉;정태상
    • Journal of Biosystems Engineering
    • /
    • 제36권5호
    • /
    • pp.319-325
    • /
    • 2011
  • This study was conducted to figure out the diagnosis basis of cooling performance depending on water amount in the refrigerant of air conditioner, which can be estimated by the temperatures and pressures along the refrigerant circulation line. A car air conditioner of SONATA III (Hyundai motor Co., Korea) was tested at maximum cooling condition at the engine speed of 1500 rpm in the room controlled at 33~$35^{\circ}C$ air temperature and 55~57% relative humidity conditionally. Measured variables were temperature differences between inlet and outlet pipe surfaces of the compressor, condenser, receive drier and evaporator; and high pressure and low pressure in the refrigerant circulation line; and temperature difference between inlet and outlet air of the cooling vent of evaporator. In this study, changes of the water amount in the refrigerant were correlated to the temperatures and pressure changes and also water amount caused poor cooling performance. As water amount increased in the refrigerant in the air conditioner, the performance of the cooling or the heat transfer became worse. Temporal variations of the surface temperature of the evaporator outlet pipe and the low-side pressure showed various patterns that could estimate the water amount. When the water amount caused bad cooling performance, the patterns of the temperature of the evaporator outlet pipe indicated irregular fluctuation greater than $5^{\circ}C$. When the diagnosis system is using just external sensors of the low-side pressure and the temperatures of inlet and outlet air of cooling vent of the evaporator, the precise pattern of bad cooling performance caused by excess water amount in the cooling line was irregular pressure fluctuation, 25 kPa under 120 kPa, and temperature, $12^{\circ}C$ and less.

상수도(上水道)의 1일(日) 급수량(給水量) 및 배수지(配水池) 용량(容量) 변화(變化)에 관한 연구(硏究) (The Variation of the Urban Water Use and the Distribution Reservior Capacity with Time for a Day)

  • 이경훈;박성천;문병석
    • 상하수도학회지
    • /
    • 제9권2호
    • /
    • pp.118-126
    • /
    • 1995
  • The variation of the urban water demand and the amount of water in the distribution reservoir was studied with time for a day. The city of Kwangju in Korea was selected as a study area. The population of Kwangju in the end of 1993 was more than one million and two hundred thousand peoples. The average of daily water use in 1993 was about three hundred and fifty thousand tons a day. One day was devided into 12 divisions with a 2 hour increment. The water use demand related to the amount of water in the distribution reservoir was observed for the given time interval of a day. The water use index was defind in percentage that indicates the ratio of the amount of water use for a time interval to the amount of water use for a day. The water use index with consideration of the water stored in the reservoir was found to be useful to manage and to operate the water supply systems in real time.

  • PDF

공동주택단지 내 인공지반 녹지조성 형태에 따른 우수유출 저감효과 (A Study on Runoff Water Reduction Effects According to Shapes of Formation of Artificial Soil Green Area in Multi-Housing Complex)

  • 남미아;장대희;김현수
    • KIEAE Journal
    • /
    • 제13권1호
    • /
    • pp.9-15
    • /
    • 2013
  • This study aims to analyze, by forming an experimental area of artificial soil green area that is of equal scale and analyzing the characteristics of runoff water in accordance with the cross-section configuration, applied the benefits in an actual multi-housing case study complex. In examining the measurement test results of the runoff water infiltration amount and surface runoff amount of a low-profile type green area(Dish type) and a general type green area(Mound type), Dish type was seen to have 1.5-times higher runoff water infiltration amount than Mound type during heavy rainfalls and showed about a 50% reduction with respect to the surface runoff amount. In other words, artificial soil green area offers the benefit of reduction of surface runoff amount and suggests, in actuality even with a change to the cross-sectional configuration of artificial soil green area alone at the time of construction of multi-housings, the possibility of benefits and reduction of costs spent on existing rainwater management facilities.

도시지역의 지하수수지 (Groundwater Balance in Urban Area)

  • 이승현;배상근
    • 한국환경과학회지
    • /
    • 제20권12호
    • /
    • pp.1553-1560
    • /
    • 2011
  • The study analyzes groundwater balance with regard to the water recharge and discharge which contain urbanization components in Suyeong-gu, Busan. It also verifies the reliability and accuracy improvement on the analysis of the balance. The result of the study is viewed as preliminary data which are useful to develop, utilize and manage groundwater. The average quantity of groundwater recharge is 6,014.1 $m^3$/day in the research area during the last ten year period(from 1998 to 2007). The outflow from drainage areas to rivers and coasts is 149.3 $m^3$/day, the inflow from rivers and coasts to drainage area is 439.9 $m^3$/day. The use of the water is 4,243.0 $m^3$/day. The outflow caused by subway in line No.2 and No.3 through Suyeong-gu and the one by building an underground electric complex is 1,500.0 $m^3$/day. The leakage of water works is 6514.9 $m^3$/day. The inflow and outflow of sewerage is 5082.2 $m^3$/day from groundwater to sewer. The amount of groundwater recharge, the inflow from rivers and coasts to drainage area, and the leakage of water works belong to the amount of groundwater inflow and the total amount is 12,968.9 $m^3$/day. The amount of outflow from drainage area to rivers and coasts, the use of groundwater, outflow by subway and underground electric complex tunnel and the amount of inflow of the water to sewerage belong to the amount of outflow of groundwater and the sum amount is 13,031.5 $m^3$/day. The gap between the amount of inflow and outflow of groundwater is 62.6 $m^3$/day, which is considered to reflect the trend that the short term drop in the amount of rainfall results in the amount of groundwater recharge and that the amount of outflow from drainage area to rivers and coasts decreases.

정수공정에서 분배조 및 밸브 개도율 최적화 (Optimization of distribution basin and ratio at valve opening in the water treatment process)

  • 조영만;류동춘;유평종
    • 상하수도학회지
    • /
    • 제29권5호
    • /
    • pp.559-564
    • /
    • 2015
  • Distribution basins are used widely in the water treatment process. Uniform distribution at the distribution basin is an important because it affect precipitation efficiency of sedimentation basin. Generally distribution basin has a free surface water and is consisted of a weir. Study result, when inflow of distribution basin is less, amount of overflow is much at the nearest weir from the inlet. But when inflow is much, amount of overflow is much at the far weir from the inlet. The difference of distribution amount at the pipe is affected by the curvature and length of the pipe. The magnitude of the effect is determined by the relative energy loss and the flow state of the distribution basin. Optimization of the response surface method for minimizing an amount of deviation of the distribution is a very useful technique to determine the optimal ratio of the valve opening.

백운산 지역에서 계류수의 이화학적 성질에 미치는 양어장의 영향(II) (Influences of Fish Farm on the Physicochemistry of Stream Water Quality in (Mt.) Paekun Area(II))

  • 박재현;우보명;김우룡;안현철
    • 한국환경복원기술학회지
    • /
    • 제4권1호
    • /
    • pp.32-40
    • /
    • 2001
  • Quantifications of fish farm influences on stream water quality may provide basic informations on watershed management to reduce environmental impact due to fish farm development and to conserve stream water quality in forested watershed area. In this research stream water qualities around Mt. Paekun area were monitored seasonally and the following results were obtained. Due to the increase of pH in effluent water from the fish farm it was believed that alkalization of stream water can be accelerated by large scale development of fish farms in the forested watershed area. Negative effects on stream water quality were observed by indications of increase in electrical conductivity and temperature of effluent water from the fish farm. Decreases in physicochemical indices such as the amount of dissolved oxygen, percentage of dissolved oxygen, total amount of cation, total amount of anion and total amount of ion in effluent water from the fish farm were also negative aspects in downstream ecology. It is recommended that water purification system as well as eco-friendly fish farm design should be incorporated to large scale fish farm development plan in forested watershed area.

  • PDF

학교건축의 적정 급수량 산정을 위한 사용수량 분석 (An Analysis on Water Supply Amount for Economic Plan in School Buildings)

  • 이재윤
    • 한국산학기술학회논문지
    • /
    • 제16권4호
    • /
    • pp.2924-2932
    • /
    • 2015
  • 본 연구는 초등학교, 중학교 및 고등학교의 급수설비 사용수량의 분석 통해 급수량 산출자료를 추정하여 학교시설 급수시스템의 적정 급수계획에 필요한 기초자료를 얻고자 하였다. 이를 위하여, 강원지역 6개 도시에 소재하는 초 중 고등학교 54개 학교를 대상으로 5년간의 급수설비 사용수량을 분석하였다, 분석결과, 1) 월평균 사용수량의 평균은 $600.7(m^3/mon)$이었으며, 초등학교와 중학교가 $484.2(m^3/mon)$, 고등학교가 $833.8(m^3/mon)$로 분석 되었다. 2) 학급당 월평균 사용수량의 평균은 $27.0(m^3/mon/class)$이었으며, 초등학교와 중학교가 $24.4(m^3/mon/class)$, 고등학교가 $32.(m^3/mon/class)$로 분석 되었다. 3) 1인1일 평균 사용수량의 평균은 55.8(l/c/d)이었으며, 초등학교와 중학교가 54.4(l/c/d), 고등학교가 58.6(l/c/d)로 분석 되었다.

둑높이기 농업용저수지의 환경용수 방류기준 설정 (Optimizing Rules for Releasing Environmental Water in Enlarged Agricultural Reservoirs)

  • 유승환;이상현;최진용;박태선
    • 한국농공학회논문집
    • /
    • 제54권5호
    • /
    • pp.17-24
    • /
    • 2012
  • The main purposes of the agricultural reservoir enlargement (ARE) project are to secure water supply reliability (WSR) for agriculture and to release environmental water during dry seasons. In this study, an operational rule that will simultaneously satisfy both the above issues was developed. Initial amount of water storage at the beginning of non-irrigation season (1st October) was divided into 3 stages, and the target level of water storage at the beginning of irrigation seasons (1st April) was set up. Required operational curves and release amounts were estimated based on the stages and target water levels. To evaluate the applicability of this rule, the amount of water released for environmental purposes and WSRs were analyzed for three reservoirs (Unam, Jangchi and Topjeong). The ratio between annual amount of release and additional amount of water storage were 1.6, 1.85, and 4.1 for the Unam, Jangchi, Tapjeong reservoirs, respectively. Also, the WSRs of all reservoirs were found to become higher than when the design standard was applied. Therefore, it is considered that the proposed rule is more suitable for the enlarged agricultural reservoirs operation as it satisfies the WSRs while securing the environmental water release.

공항용수 원단위 산정 및 용수 사용량 추정방법 (Estimation of water unit factor and water demand of domestic airports)

  • 김태영;김태환;허동;박희경
    • 상하수도학회지
    • /
    • 제23권2호
    • /
    • pp.231-239
    • /
    • 2009
  • The purpose of this research is to provide more reliable water unit factors of domestic airports by investigating of general informations related to the domestic airport. The informations of domestic airports such as passengers, settled population of airports, building areas and water amount are investigated to estimate the unit factor of water of domestic airports. The domestic airports are divided into three type such as central airport, position airport and general airport. Through analysis of relationship between water amount and the others, the unit factor of water could be calculated. The water amount of central airport as Incheon international airport and position airports could be estimated by unit factor of settled population. The others could be estimated by unit factor of building area.