• Title/Summary/Keyword: amount of water

Search Result 7,117, Processing Time 0.032 seconds

Experimental Validation on Performance of Waste-heat-recovery Boiler with Water Injection (물분사 폐열회수 보일러의 효용성에 대한 실험적 검증)

  • Jaehun Shin;Taejoon Park;Hyunseok Cho;Junsang Yoo;Seoksu Moon;Changeon Lee
    • Journal of ILASS-Korea
    • /
    • v.28 no.1
    • /
    • pp.43-48
    • /
    • 2023
  • The waste-heat-recovery boiler with water spray (HR-B/WS) applies the heat exchange between the inlet air and exhaust gas with the water spray into the inlet air. The evaporation of water in the inlet air promotes heat recovery from the exhaust gas so that thermal efficiency can be improved by the enhanced condensing effect. The NOx emission can also be reduced by lowering the flame temperature due to the dilution effect of the water. In this study, the validity of this concept is examined by the practical boiler test performed with a 24 kW condensing boiler under the full load condition according to the water injection amount. The theoretical amount of water injection is calculated under the assumption of full evaporation of the sprayed water, which is calculated as 50 g/min. Since the injected water cannot evaporate fully in the actual system, the maximum water spray amount is set as 100 g/min. The results showed that the water injection can increase the thermal efficiency up to 95.59% and reduce NOx and CO emissions simultaneously to 8.9 ppm and 35 ppm at 0% of O2. Although the heat energy loss increased due to the unevaporated water, the increase in water injection amount caused higher thermal efficiency due to the increased amount of the evaporated water.

A Study on the Potential Energy Reserve Amount of Domestic River Water as Unutilized Energy Resource (국내 하천수 미활용에너지 부존량에 관한 조사연구)

  • Park Il-Hwan;Yoon Hyung-Kee;Park Jun-Taek;Chang Ki-Chang;Lee Young-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.6
    • /
    • pp.521-528
    • /
    • 2005
  • This study has been conducted to investigate the potential energy reserve amount of river water as energy resource with useful temperature difference. Since the river water temperature is one of the primary parameters deciding the potential amount of river water energy reserve amount, the climate change effects on it are critically important. In this study, the heat exchange processes and the inter-relationship between the air temperature and river water temperature have been theoretically analyzed. Based on the present study, the potential energy reserve of river water is calculated to amount to 192,000 Tcal/year. Among this, it is estimated that approximately 2,000 Tcal/year can be directly utilized for heat pump energy sources.

Water Absorption Characteristics of Substrate with Physical Properties of wick in Subirrigation System Using wick (심지형 저면관수시스템의 심지의 물리적 성질에 따른 수분흡수 특성)

  • Dong Ho Jung;Jung Eek Son
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2001.04b
    • /
    • pp.41-42
    • /
    • 2001
  • The objectives of this study were to investigate the effect of the physical properties of wick on the water absorption of substrate. Physical properties of wick in this study were cotton composition, width and length. The water Infiltration rate through the wick was 0.24 ㎝/s at 90 -95% cotton content, which was faster than at 80-85% (0.13 cm/s) and 70-75% (0.08 cm/s). As the cotton content increased, the water absorption of substrate became greater : the amount of absorbed water was about 5-7g higher at 90-95% than at 80-85% and 70-75% at a wick width of 1 ㎝, the velocity of water absorption through the wick was fastest with 0.25 ㎝ㆍs/sup -1/. The amount of absorbed water was higher at 3 ㎝ than at 1 and 2 ㎝. However, the water absorption rate through the cross - sectional area of wick (g H₂O /㎠/hr) was higher at a wick width of 2 ㎝ than at those of 1 and 3 ㎝. The amount of absorbed water in the substrate was higher at 2 : 1 than at 1 : 1 (length in substrate : length out of substrate). Absorbed water amount was larger at 30-40% initial moisture content than any other treatment.

  • PDF

Effects of Amount of Slaking Water on Physical and Chemical Properties of Handmade Hydrated Lime used for Preservation of Architectural Heritage (소화에 사용되는 물의 양이 건축 문화재 보존용 수제 소석회의 물리 및 화학적 특성에 미치는 영향)

  • Kang, Sung-Hoon;Hwang, Jong-Kook;Kwon, Yang-Hee
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.2
    • /
    • pp.21-28
    • /
    • 2019
  • Handmade hydrated lime has been used for preservation and repair of architectural heritage in Korea. However, the effect of the amount of water used for slaking quicklime on the physical and chemical properties of the hydrated lime, which is the result of the slaking process, has not been clearly understood. In this study, particle size distribution, chemical composition and crystalline phases of the hydrated lime are investigated by varying the amount of water used for the slaking. In addition, temperature history during the slaking process is examined. For this, various experiments, such as laser diffraction analysis, X-ray fluorescence, X-ray diffraction, thermogravimetric analysis, and temperature recording using a thermocouple, were performed. When the quicklime came into contact with water, its temperature reached $100^{\circ}C$ within 10 min due to sudden exothermic reaction of calcium oxide, and this temperature was maintained for about 30 min. The water to lime ratio influenced the cooling rate during the slaking process; that is, the more water was used, the longer it took to reach an ambient temperature. The amount of water for the slaking did not have a noticeable effect on the contents of major components of the hydrated lime such as calcium hydroxide and calcium carbonate, but when slaked with more amount of water, average particle size of the lime tended to decrease. The experimental results in this study can be used as references for developing guidelines on the safety or appropriate amount of water in the lime slaking process.

A Study on the Quantity of Using Water in APT for Estimating the Reasionable amount of Water Supplied (아파트에서 적정 급수량 산정을 위한 사용수량에 관한 조사 연구)

  • ChangHuanAn
    • Journal of the Korean housing association
    • /
    • v.5 no.1
    • /
    • pp.85-90
    • /
    • 1994
  • Using water in each apartment is influnced by several facters including the income level of inhabitants, the manner of life, the area apartments and climate. The automization of santory machines or facilites in recently bulit apartements has caused largely increases in amount of water use. Therefore the design for water supply is very important for the maintenance of the optimum level or pressure of water supply. This study is based on the offer of basic data for improving the quality of water supply and imploying the sanitory machine or sanitory facilites by analysis of amount increased of water use rapidly. The quantity of hot and cold water use by year is examined as a factor of construction in apartment.

  • PDF

Estimation of Regional Agricultural Water Demand over the Jeju Island (제주도 권역별 농업용수 수요량 산정에 대한 고찰)

  • Choi, Kwang-Jun;Song, Sung-Ho;Kim, Jin-Sung;Lim, Chan-Woo
    • Journal of Environmental Science International
    • /
    • v.22 no.5
    • /
    • pp.639-649
    • /
    • 2013
  • Over 96.2% of the agricultural water in Jeju Island is obtained from groundwater and there are quite distinct characteristics of agricultural water demand/supply spatially because of regional and seasonal differences in cropping system and rainfall amount. Land use for cultivating crops is expected to decrease 7.4% (4,215 ha) in 2020 compared to 2010, while market garden including various vegetable crop types having high water demand is increasing over the Island, especially western area having lower rainfall amount compared to southern area. On the other hand, land use for fruit including citrus and mandarin having low water demand is widely distributed over southern and northern part having higher rainfall amount. The agricultural water demand of $1,214{\times}10^3\;m^3/day$ in 2020 is estimated about 1.39 times compared to groundwater supply capacity of $874{\times}10^3\;m^3/day$ in 2010 with 42.4% of eastern, 103.1% of western, 61.9% of southern, and 77.0% of northern region. Moreover, net secured amount of agricultural groundwater would be expected to be much smaller due to regional disparity of water demand/supply, the lack of linkage system between the agricultural water supply facilities, and high percentage of private wells. Therefore, it is necessary to ensure the total net secured amount of agricultural groundwater to overcome the expected regional discrepancy of water demand and supply by establishing policy alternative of regional water supply plan over the Island, including linkage system between wells, water tank enlargement, private wells maintenance and public wells development, and continuous enlargement of rainwater utilization facilities.

Investigation on the Distnbution of the Groundwater at paho-Dong Area (지하수 수자원 분포에 관한 조사연구 (경북 달성군 파호동을 중심으로))

  • 나인엽
    • Water for future
    • /
    • v.12 no.2
    • /
    • pp.36-42
    • /
    • 1979
  • This study has been conducted to find out the location and amount of the subterrain water body developed in the alluvial stratum in Paho-Dong, Sungsee-Myo-n, Dalsung-Kun are. An earlier test drilling was done in this area by R.O.K. Agricultural Promotion Corporation. The area consists of a small river basin and surrounding low hills developed around the junction of the Nakdong and Kumho Rivers. The strata of this area are made of Paldal gravel, Bokhyundong and Banyawol layers which were formed in the cretaceous period of the Meso-saicera or acid dikes and covered with-irregular alluvial layers. The alluvial layer in this area is composed of rather minute particles and proportional electric resistance tests on this layer show $10^2\;-\;10^3\;\Omega/cm$. The drillings up to 12meters deep showed only the sand layer (Form 3 to 26meters in thickness) contains water. The sand layers can not be considered a good water trapping one. Applying the data from the drillings to A.Hazen's equation, $K\;=\;{cd_e}^2\;(0.7\;+0.03t)$ to get the theoretical value of the water infilterated, I calculated it as K=13.92m/day. And again the value was set to Dupuit equation, (equation omitted) to acquire the pumping water amount the result was $Q_1\;=\;77.20\;\textrm{m}^3/day$. When the data-applied to the equation for pumping water amount, (equation omitted), the results were $Q_2\;=\;122.39\;\textrm{m}^3/day$ and K = 38m/day $Q_1\;and;Q_2$ (tow types of pumping water amount) represent proper value decrease and maximum value decrease respectively. Therefore, $Q_2$ is the least amount of water we can pump. The area covers about $1,555,000\;\textrm{m}^2$ and the maximum water needed in this area amounts to $155,000\textrm{m}^3$. That means we have to drill 1,406 pumping wells. It is concluded that undertaking the project in this area is irrational or even desperate and surface water should be developed more favorably.

  • PDF

A Study on the Estimation of Irrigation Water for Sewage Treated Water Reuse for Agriculture (하수처리수의 농업용수 재이용을 위한 관개수량 산정방법에 관한 연구)

  • Cho, Hyun Kyung;Kim, Sang Min
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.2
    • /
    • pp.97-104
    • /
    • 2019
  • The purpose of this study was to establish the estimation method of irrigation water amount for sewage treated water reuse for agricultural purpose. To calculate the irrigation water amount, we adopted Penman-Monteith for potential evapotranspiration estimation and applied crop coefficient and irrigation efficiency factor. We developed the irrigation water amount calculation program using C language in Xcode environment. The target district for calculation is having 259 ha of agricultural land located near the Jinyeong Clear Water Circulation Center in Hanrim-myeon, Gimhae city. The meteorological data of the study area were obtained from Changwon weather station from 1986 to 2017. Calculated average and maximum of annual mean potential evapotranspiration were 2.72 mm/day and 6.22 mm/day, respectively. We used K-S (Kolmogorov-Smirnov) for goodness-of-fit test to find optimal probability distribution of annual mean and maximum evapotranspiration. As a result, the normal distribution was selected for the appropriate distribution. The annual mean and maximum potential evapotranspiration for 10-year return period by applying normal distribution were 2.88 mm/day and 6.76 mm/day, respectively. Assuming that the irrigation efficiency is 80%, the irrigation water requirement was calculated as $36.05m^3/day/ha$ and $84.45m^3/day/ha$, respectively, when annual mean and maximum potential evapotranspiration were applied. The actual irrigation water amount can be calculated by applying the crop coefficient and cropping days for the study area based on the developed irrigation water amount estimation program in this study.

Smart Water Purifier by Application Interworking (애플리케이션 연동을 통한 스마트 정수기)

  • Kim, Ji Woo;Lee, Seung Mok;Kim, Tae Hoon;Lee, Seung Ho;Woo, Young Woon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.410-412
    • /
    • 2021
  • Recently, the amount of information and content has increased dramatically. Users can easily obtain recipe through various media. In addition, the water purifier market is growing without a downward trend and demand for more convenient and smart water purifiers are increasing. By using a smart water purifier with application, each individual can improve the quality of the dish by using a certain amount of water that each person prefers. A solenoid valve was used to allow only the amount of water set by individual to flow out and a solenoid valve and smartphones were linked using Bluetooth communication while using smartphone applications developed when setting the amount of water.

  • PDF

A Study on Economic benefits for Water Control Device Installed with a Flush Valve on a Toilet (세척밸브 급수제어장치 설치에 따른 경제적 효과 분석)

  • Park, Kang-Hyun;Kim, Su-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.10
    • /
    • pp.656-661
    • /
    • 2011
  • The amount of water resources that can be used tend to be decreased gradually. In contrast, the rapidly increasing water consumption is a problem that need to be addressed. Renovation and equipment replacement to improve energy efficiency and to reduce expenditure for building usage is required. But the excessive initial investment cost and the prolonged of pay back period may be uneconomical choice. Water usage for cleaning the toilet bowl accounts for 27%of the total water usage. Water-saving valve that can select the amount of water for cleaning toilet bowl can be reduced expenditure. After installing water-saving valve, analysed the economic effects. Water-saving valves compared with flush valves, and researched the amount of water usage. Then analyzed for the economic effects. Water-saving valve was used 5.6 ${\ell}$/time for cleaning toilet bowl. In contrast, flush valve was consumed 8.4 ${\ell}$/time. Water-saving valve's water-saving rate was 33.3%. The initial payback period for Water-saving valve was 459.5 days. By a small investment in water saving valve, the economic benefits can be obtained.