• Title/Summary/Keyword: ammonium-based solvent

Search Result 16, Processing Time 0.024 seconds

The Extraction of Metal Contaminants using Supercritical CO2 (초임계이산화탄소를 이용한 방사성 금속이온 추출)

  • Ju, Minsu;Kim, Jung-Hoon;Kang, Se-Sik
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.5
    • /
    • pp.660-667
    • /
    • 2016
  • Conventional decontamination methods utilize water-based systems, which generate high amounts of secondary wastes. Herein, we describe an environmentally benign decontamination method using liquid and supercritical $CO_2$. The use of $CO_2$ as a solvent affords effective waste reduction by its ability to be recycled, thereby leaving be hind only the contaminants upon its evaporation. In this study, a $CO_2$ solution process was assessed using t-salen(t-butylsalen), DC18C6 (dicyclohexano-18Crown6), 8-HQN(8-hydroxyquinoline), NEt4PFOSA(perfluoro-1-octanesulfonic acid tetra-ethyl ammonium salt), and NEt4PFOA(pentadecafluorooctanoic acid ammonium salt) to extract spiked radioactive contaminants(Nb,Zr,Co,Sr) from an inert sample matrix, namely filter paper. With the static extraction method, Sr was extracted with a maximum extraction rate of 97%, and Nb was extracted with a maximum extraction rate of 75%. Additionally, we were also able to extract Co and Zr with maximum extract ion ratesof 73% and 64%, respectively.

Albumin Release from Biodegradable Hydrogels Composed of Dextran and Poly(Ethylene Glycol) Macromer

  • Kim, In-Sook;Jeong, Young-Il;Kim, Do-Hoon;Lee, Yun-Ho;Kim, Sung-Ho
    • Archives of Pharmacal Research
    • /
    • v.24 no.1
    • /
    • pp.69-73
    • /
    • 2001
  • Biodegradable hydrogels based on glycidyl methacrylate dextran (CMD) and dimethacrylate poly(ethylene glycol) (DMP) were proposed for colon-specific drug delivery. GMD was synthesized by coupling of glycidyl methacylate with dextran in the presence of 4-(N, N-dimethylamino)pyridine (DMAP) using dimethylsulfoxide as a solvent. Methacrylate-terminated poly (ethylene glycol) (PEG) macromer was prepared by the reaction of PEG with methacryloyl chloride. CMD/DMP hydrogels were prepared by radical polymerization of phosphate buffer solution (0.1 M, pH 7.4) of GMD and DMP using ammonium peroxydisulfate (APS) and UV as initiating system. The synthetic GMD, DMP and GMD/DMP hydrogels were characterized by fourier transform infrared (FT-lR) spectroscopy. The FITC-albumin loaded hydrogels were prepared by adding FITC-albumin solution before UV irradiation. Swelling capacity of GMD/DMP hydrogels was controlled not only by molecular weight of dextran, but also by incorporation ratio of DMP Degradation of the hydrogels has been studied in vitro with dextranase. FITC-albumin release from the GMD/DMP hydrogels was affected by molecular weight of nextran and the presence of dextranase in the release medium.

  • PDF

Determination of Theophylline and its Metabolites in Human Urine by High-Performance Liquid Chromatography

  • Kim, Kyeong-Ho;Park, Young-Hwan;Park, Hyo-Kyung;Kim, Ho-Soon;Lee, Min-Hwa
    • Archives of Pharmacal Research
    • /
    • v.19 no.5
    • /
    • pp.396-399
    • /
    • 1996
  • High-performance liquid chromatographic method with UV detecction was developed for the determination of theophylline and its metabolites in human urine using ${beta}$-hydroxyethyl theophylline$({beta} -HET)$ as an internal standard. For extraction of urine sample, quality control sample and xanthine-free blank urine were mixed with decylamine (ion-paring reagent) and ${beta}$-HET. After saturation with ammonium sulfate, the mixture was then extracted with organic solvent at pH values of 4.0-4.5. All separations were performed with ion-pair chromatography using decylamine as an ion-pairing reagent and 3mM sodium acetate buffered mobile phase (pH 4.0) containing 1% (v/v) acetonitrile and 0.75 mM decylamine. The detection limits of theophylline, 1, 3-DMU, 1-MU, 3-MX and 1-MX in human urine were 0.17, 0.17, 0.39, 0.19 and 0.19 ${\mu}g$/ml, based on a signal-to-noise ratios of 3.0. The mean intraday coefficients of variation (C.V.s) of each compound on nine replicates were lower than 2.0%, while mean interday C.V.s on three days were lower than 1.6%. All separations were finished within 40miutes.

  • PDF

Simultaneous Liquid Chromatography Tandem Mass Spectrometric Determination of 35 Prohibited Substances in Equine Plasma for Doping Control

  • Kwak, Young Beom;Yu, Jundong;Yoo, Hye Hyun
    • Mass Spectrometry Letters
    • /
    • v.13 no.4
    • /
    • pp.158-165
    • /
    • 2022
  • Many therapeutic class drugs such as beta-blocker, corticosteroids, NSAIDs, etc are prohibited substances in the horse racing industry. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) technology makes it possible to isolate drugs from interference, enables various drug analyses in complex biological samples due to its sensitive sensitivity, and has been successfully applied to doping control. In this paper, we describe a rapid and sensitive method based on solid-phase extraction (SPE) using solid phase cartridge and LC-MS/MS to screen for different class's 35 drug targets in equine plasma. Plasma samples were pretreated by SPE with the NEXUS cartridge consisted non-polar carbon resin and minimum buffer solvent. Chromatographic separation of the analytes was performed on ACQUITY HSS C18 column (2.1 × 150 mm, 1.8 ㎛). The elution gradient was conducted with 5 mM ammonium formate (pH 3.0) in distilled water and 0.1% formic acid in acetonitrile at a flow rate of 0.25 mL/min. The selected reaction monitoring (SRM) mode was used for drug screening with multiple transitions in the positive ionization mode. The specificity, limit of detection, recovery, and stability was evaluated for validation. The method was found to be sensitive and reproducible for drug screening. The method was applied to plasma sample analysis for the proficiency test from the Association of Racing Chemist.

Improved Radiochemical Yields, Reliability and Improvement of Domestic $^{18}F$-FDG Auto Synthesizer (국산 $^{18}F$-FDG Auto Sysnthesizer의 수율 향상과 성능 개선)

  • Park, Jun-Hyung;Im, Ki-Seop;Lee, Hong-Jin;Jeong, Kyung-Il;Lee, Byung-Chul;Lee, In-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.147-151
    • /
    • 2009
  • Purpose: 2-[$^{18}F$]Fluoro-2-deoxy-D-glucose ([$^{18}F$]FDG) particularly plays as a important role in Positron Emission Tomography (PET) imaging in nuclear medicine. Domestic [$^{18}F$]FDG auto synthesizers are installed in Seoul National University Bundang Hospital (SNUBH) at June 2008, these modules were known that it's synthetic yields were guaranteed in average $45{\pm}5%$ so far. To improve yields and convenience of domestic [$^{18}F$]FDG auto synthesizer, numerous trials in reaction time, base concentration, pressure and temperature were performed to increase [$^{18}F$]FDG yields. Materials and Methods: Several synthetic factors (temperature, time and pressure) and shortcoming were corrected based on many evaporation test. Syringe dispensing of tetra-butylammonium bicarbonate (TBAB) was replaced with micro pipette to prepare tetrabutyl ammonium fluoride salt ([$^{18}F$]TBAF). Troublesome refill of liquid nitrogen every 2 hours which was used to protect vacuum system was changed to charcoal cartridge, base guard filter. To monitor the volume of delivered $[^{18}O]OH_2$ from cyclotron by surveillance camera, we set up the volumetric vial on the cover of the module. In addition to, the recovery vial was added in [$^{18}F$]FDG production system to recover [$^{18}F$]FDG loss due to the leak of valve ($V_{13,14}$) in [$^{18}F$]FDG purification process. Results: When we used micro pipette for adding TBAB ($30\;{\mu}L$ in 12% $H_2O$ in acetonitrile), this quantitative dispensation has enabled to improve $5.5{\pm}1.7%$ residual fluorine-18 activity in fluorine separation cartridge compared to syringe adding. Besides, the synthetic yields of [$^{18}F$]FDG has increased $58{\pm}2.6%$ (n=19), $58{\pm}2.9%$ (n=14), $60%{\pm}2.5%$ (n=17) for 3 months. The life cycle of charcoal cartridge and base vacuum was 3 months prior to filling liquid nitrogen every 2 hours and additional side separator can prevent pump corrosion by organic solvent. After setting of volumetric indicator vial, the operator can easily monitor the total volume of irradiated $[^{18}O]OH_2$ from cyclotron. The recovery vial can be used for the stabilizer when an irregular [$^{18}F$]FDG loss was generated by the leak of valves ($V_{13,14}$). Conclusions: We has optimized appropriate synthetic conditions (temperature, time, pressure) in domestic [$^{18}F$]FDG auto synthesizer. In addition to, the remodeling with several accessories improve yields of domestic [$^{18}F$]FDG auto synthesizer with reliable reproducibility.

  • PDF

On the Utilization of Inactive BHC isomers -Synthesis of 3-(2,4,5-trichlorophenyl)-1-methyl urea as a herbicide- (BHC 이성질체(異性質體)의 활용(活用)에 관(關)한 연구(硏究) -제초제(除草劑)로서 3-(2,4,5-trichlorophenyl)-1- methyl urea의 합성(合成)-)

  • Lee, Kyu-Seung;Park, Chang-Kyu
    • Applied Biological Chemistry
    • /
    • v.22 no.2
    • /
    • pp.109-122
    • /
    • 1979
  • Present study was carried out to reduce residual toxicity of BHC insecticides inherent in the organochlorine pesticides. For This end, r-isomer, the most potent insecticidal component among the BHC stereoisomers, was isolated and thus fortified by means of solvent precipitation. In parallel, 3-(2,4,5-trichlorophenyl)-1-methyl urea was prepared in good yield from technical BHC via 1,2,4-trichlorobenzene, 1,2,4,-trichloronitrobenzene, and 2,4,5-trichloroaniline. In addition, certain merit of the compound which make it possible to use as a herbicide is discussed. The results are summarized as follows; 1. Recrystallizing technical BHC from methanol-water binary solvent system, r-isomer was enriched to 49.7% at 95% recovery of r-isomer. 2. By partitioning technical BHC in 85% of methanolic solution into chloroform, r-isomer was fortified to 89.6% at 90.5% recovery of r-isomer. 3. Yield of 1,2,4-trichlorobenzene from technical BHC was greatly dependent upon concentration of alkalies and to less degree on the alkalies. 4. Surfactants, in particular cationic a quartenary ammonium salt, increased yield of 1,2,4-trichlorobenzene from technical BHC by alkaline hydrolysis. 5. Conversion of 1,2,4-trichlorobenzene to 2,4,5-trichloronitrobenzene was effected almost quantitatively utilizing $HNO_3-H_2SO_4$ nitrating agent at low temperature. 6. Yield of 91.4% was observed for the synthesis of 2,4,5-trichloroaniline by reducing 2,4,5-trichloronitrobenzene in the presence of iron turning and hydrochloric acid. 7. Overall yield based on BHC of 3-(2,4,5-trichlorophenyl)-1- methyl urea was 60.8%. 8. Inhibition effects, both germination and growth, 3-(2,4,5-trichlorophenyl)-1-methyl urea on several crops were found comparable to or more potent than those of $linuron{\circledR}\;and\;diuron{\circledR}$. In addition, it was also noted that susceptibility to the prepared compound depended upon the crops as well as specific part (shoots, roots) of the plant exposed to the chemicals.

  • PDF