• 제목/요약/키워드: ammonia removal,

검색결과 563건 처리시간 0.026초

Melandrin의 합성 (Synthesis of Melandrin)

  • 문정술;이강노;임중기;우원식
    • 약학회지
    • /
    • 제35권4호
    • /
    • pp.332-334
    • /
    • 1991
  • The synthesis of melandrin has been accomplished in good yield by the reaction of 5-tosyloxyanthranilic acid ethyl ester with p-acetoxybenzoyl chloride, followed by removal of protecting groups with methanolic ammonia.

  • PDF

Performance of Chlorella vulgaris for the Removal of Ammonia-Nitrogen from Wastewater

  • Choi, Hee-Jeong;Lee, Seung-Mok
    • Environmental Engineering Research
    • /
    • 제18권4호
    • /
    • pp.235-239
    • /
    • 2013
  • In the present investigation, the efficiency of Chlorella vulgaris (C. vulgaris) was evaluated for the removal of ammonia-nitrogen from wastewater. Eight different wastewater samples were prepared with varied amounts of $NH_4-N$ concentrations from 15.22 to 205.29 mg/L. Experiments were conducted at pH $7.5{\pm}0.3$, temperature $25^{\circ}C{\pm}1^{\circ}C$, light intensity $100{\mu}E/m^2/s$, and dark-light cycles of 8-16 hr continuously for 8 days. From the results, it was found that $NH_4-N$ was completely removed by C. vulgaris, when the initial concentration was between 5.22-25.24 mg/L. However, only 50% removal was obtained when the $NH_4-N$ concentration was 85.52 mg/L, which further decreased to less than 32% when the $NH_4-N$ concentration exceeded 105.43 mg/L. The further influence of nitrogen on chlorophyll was studied by various $NH_4-N$ concentrations. The maximal value of chlorophyll a (Chl a) content was found to be 19.21 mg/L for 65.79 mg/L $NH_4-N$ concentration, and the maximum specific $NH_4-N$ removal rate of 1.79 mg/mg Chl a/day was recorded at an $NH_4-N$ concentration of 85.52 mg/L. These findings demonstrate that C. vulgaris could potentially be employed for the removal of $NH_4-N$ from wastewater.

폭기 에너지 저감 연속회분식반응조 운전과 미생물 군집 변화 특성 (Performance of sequencing batch reactor under aeration-limited condition and characteristics of microbial community change)

  • 황국선;신동혁;정인교;박성제;장인수;김정배;최정동
    • 상하수도학회지
    • /
    • 제33권3호
    • /
    • pp.215-224
    • /
    • 2019
  • Recent focus on wastewater treatment includes energy-saving and renewable energy generation for energy-independence of water infrastructures. Aeration and pumping in biological wastewater removal processes account for nearly 30-60% of the total electricity cost in real wastewater treatment plants. In this study, the performance and microbial characteristics were investigated in sequencing batch reactor under typical oxygen and oxygen limited condition. Under typical DO ($7.55{\pm}0.99mg/L$) and low DO ($0.23{\pm}0.08mg/L$) conditions, COD removal was stable over 91 % during SBR operation. Ammonia removal efficiency was reduced from 95.6 % to 89.2 % when DO concentration was dropped sharply. Phosphorus removal efficiency also reached 77% at oxygen-limited condition. The results indicated that removal efficiency both ammonia and phosphorus was influenced by DO condition. Microbial analysis revealed that Proteobacteria and Bacteroidetes at phylum level was dominant in typical DO and low DO conditions and DO concentration did not much affect phylum distribution. Population decrease of genera of nitrifying bacteria(Dokdonella) and Dechloromonas spp. affect removal efficiency of nitrogen and phosphorus at low DO condition.

하수처리시설의 질산화 진단기반 제어 방법의 개발 및 실규모 플랜트 적용을 통한 평가 (Evaluation of Diagnosis-based Control Strategy for NH4-N and NOX-N Removal of a Full-scale Wastewater Treatment Process)

  • 김예진;김효수
    • 한국환경과학회지
    • /
    • 제27권6호
    • /
    • pp.447-456
    • /
    • 2018
  • In this research, the target process was a modified type of a conventional aeration tank with four different influent feeding points and alternated aeration to obtain nitrogen removal. For more accurate switching of influent feeding, the process was operated under a designed control strategy based on monitoring of $NH_4-N$ and $NO_X-N$ concentrations in the tank. However, the strategy did have some limitations. For example, it was not sensitive to detecting the end of each reaction when losing the balance between nitrification and denitrification of each opposite part of biological tank. To overcome the limitations of the existing control strategy, a diagnosis-based control strategy was suggested in this research using the diagnosis results classified as normal (N), ammonia accumulation (AA) and nitrate accumulation (NA). Using the pre-designed rules for control actions, the aeration and volume of the aerated part of the reactor could be increased or decreased at a fixed mode time. In simulations of the suggested diagnosis-based control strategy, the $NH_4-N$ and $NO_X-N$ removal rates in the reactor were maintained at higher levels than those of the existing control strategy.

Piggery Slurry Composting Using Batch Operating Autothermal Thermophilic Aerobic Digestion System

  • Ahn, Hee K.;Choi, Hong L.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제19권2호
    • /
    • pp.273-279
    • /
    • 2006
  • The performance of an autothermal thermophilic aerobic digestion (ATAD) system was studied to determine if nitrogen loss, as ammonia, was affected by an exhaust gas condenser. The system was run with and without a condenser while treating $8m^3$ of piggery slurry for 8 days. The system with a condenser (SWC) maintained the reactor temperatures above $40^{\circ}C$ for 2 days during the 8 days run, while the system without a condenser (SWOC) remained above $40^{\circ}C$ for 6 days. The SWC maintained the reactor temperatures mostly at mesophilic conditions while the SWOC at thermophilc conditions. Differences in operation conditions for the two runs were mainly caused by differences in atmospheric temperatures. Soluble chemical oxygen demand (SCOD) and volatile solids (VS) removal efficiencies of the SWC (SCOD: 62%, VS: 41%) were higher than those of the SWOC (SCOD: 40%, VS: 20%). The total Kjeldal nitrogen (TKN) removal efficiency of the SWC (7%) was less than that of the SWOC (25%). The concentration of total volatile fatty acids (VFA) in the SWC was observed to be lower than the threshold value of 0.23 g total VFA/L after 6 days, while the SWOC progressed below the threshold value after 3 days. No offensive odor emissions were observed in either run, which suggest that the use of the ATAD system may be a good odor removal strategy.

Analysis on an Oxidation-Reduction Reaction of Photocatalytic Plasma Complex Module

  • KIM, Young-Do;KWON, Woo-Taeg
    • 웰빙융합연구
    • /
    • 제5권2호
    • /
    • pp.21-27
    • /
    • 2022
  • Purpose: This study is about photocatalytic technology and plasma oxidation-reduction technology. To the main cause of exposure to odor pollution, two deodorization techniques were applied to develop a module with higher removal efficiency and ozone reduction effect. Research design, data and methodology: A composite module was constructed by arranging two types of dry deodorization equipment (catalyst, adsorbent) in one module. This method was designed to increase the responsiveness to the components of complex odors and the environment. standard, unity, two types of oxidizing photo-catalyst technology and plasma dry deodorization device installed in one module to increase the potential by reduction to 76% of ozone, 100%, and 82%. Results: The complex odor disposal efficiency was 92%. Ammonia was processed with 50% hydrogen sulfide and 100% hydrogen sulfide, and ozone was 0.01ppm, achieving a target value of 0.07ppm or less. The combined odor showed a disposal efficiency of 93%, ammonia was 82% and hydrogen sulfide was 100% processed, and ozone achieved a target value of 0.07 ppm or less. Conclusions: Ozone removal efficiency was 76% by increasing Oxidation-Reduction Reaction(ORR). The H2S removal efficiency of the deodorizer was higher than that of the biofilter system currently used in sewage disposal plants.

The Characteristics of Organic Degradation and Ammonia Volatilization in the Liquid Composting of Pig Slurry

  • Kim, Chang-Gyu;Oh, Seung-Yong;Yoon, Young-Man
    • 한국토양비료학회지
    • /
    • 제50권5호
    • /
    • pp.325-335
    • /
    • 2017
  • This study was carried out for 30 days in aeration type and agitation type reactor to characterize organic matter decomposition and ammonia volatilization during the liquid composting of pig slurry, and organic matter and nitrogen removal rate through mass balance analysis was analyzed. In the aeration type reactor, the pH increased from 7.0 to 9.13, and TS 34.5%, VS 33.4%, $BOD_5$ 71.2%, $COD_{Cr}$ 62.3% and TOC 83.2% were removed. In addition, 44.6% of TN and 65.0% of ${NH_4}^+-N$ were removed. In the agitation type reactor, the pH increased from 7.0 to 8.10, and the removal rates of TS 0.9%, VS 0.5%, $COD_{Cr}$ 27.5%, $BOD_5$ 28.9% and TOC 41.3% were obtained. And TN and ${NH_4}^+-N$ showed removal rate of 25.3% and 29.2%, respectively. The first order kinetics constant related to $BOD_5$ degradation was $-0.039day^{-1}$ for aerobic liquid composting and $-0.013day^{-1}$ for agitated reactor. Nitrogen loss in aerobic liquid composting was about 2.3 times higher than that of agitated reactor, whereas FAN/TAN in aerobic liquid composting was about 7.9 times higher than that of agitation type reactor. Therefore, despite the low FAN/TAN in the agitation type reactor, the nitrogen loss rate was relatively high.

삼상유동층 반응기를 이용한 양어장 순환수 처리에 관한 연구 (Recycling Water Treatment of Aquaculture by Using Three Phase Fluidized Bed Reactor)

  • 이병헌;김정숙;강임석
    • 한국양식학회지
    • /
    • 제7권3호
    • /
    • pp.177-187
    • /
    • 1994
  • 본 연구는 삼상유동층 반응기를 양어장 순환수 처리장치로 설치하여 질산화제거를 정량화하고 최적운전방법을 도출하였다. 메디아 농도가 85g/l 일시 유기물질 부하율이 2.739-0.086 kg $COD/m^3/day$인 유동층공법에서 $56.3-94.7\%$의 SCOD 제거효율을 나타냈으며 SCOD 제거효율은 유기물질 부하가 증가할수록, HRT가 작을수록 낮아지는 경향을 보였다. 본 반응조의 최대 유기물질 제거율은 1,200 mg COD/l/day였다. 암모니아성 질소부하율이 $1.575-0.128kg\;NH_4\;^+-N/m^3/day$에서 $67.3-92.6\%$의 암모니아성 질소 제거효율을 얻었으며 암모니아성 질소제거량은 $11.2-488mg\;NH_4\;^+-N/l/day$였다. 메디아농도가 50g/l에 비해 85g/l에서 유기물질 제거 및 암모니아성 질소제거효율이 더 높았으며 메디아농도의 증가는 암모니아성 질소제거에 더 큰 효과를 보인다. 공기주입율은 일단 미생물이 부착을 하고 나면 유기물질 제거에 미치는 영향을 적으나 암모니아성 질소제거에 영향을 주므로 최소 유동가능한 공기주입율과 암모니아성 질소제거측면을 고려한 공기주입율의 산정이 요구된다.

  • PDF