• 제목/요약/키워드: ambient ionization mass spectrometry

검색결과 9건 처리시간 0.025초

Ambient Mass Spectrometry in Imaging and Profiling of Single Cells: An Overview

  • Bharath Sampath Kumar
    • Mass Spectrometry Letters
    • /
    • 제14권4호
    • /
    • pp.121-140
    • /
    • 2023
  • It is becoming more and more clear that each cell, even those of the same type, has a unique identity. This sophistication and the diversity of cell types in tissue are what are pushing the necessity for spatially distributed omics at the single-cell (SC) level. Single-cell chemical assessment, which also provides considerable insight into biological, clinical, pharmacodynamic, pathological, and toxicity studies, is crucial to the investigation of cellular omics (genomics, metabolomics, etc.). Mass spectrometry (MS) as a tool to image and profile single cells and subcellular organelles facilitates novel technical expertise for biochemical and biomedical research, such as assessing the intracellular distribution of drugs and the biochemical diversity of cellular populations. It has been illustrated that ambient mass spectrometry (AMS) is a valuable tool for the rapid, straightforward, and simple analysis of cellular and sub-cellular constituents and metabolites in their native state. This short review examines the advances in ambient mass spectrometry (AMS) and ambient mass spectrometry imaging (AMSI) on single-cell analysis that have been authored in recent years. The discussion also touches on typical single-cell AMS assessments and implementations.

Peltier Heating-Assisted Low Temperature Plasma Ionization for Ambient Mass Spectrometry

  • Lee, Hyoung Jun;Oh, Ji-Seon;Heo, Sung Woo;Moon, Jeong Hee;Kim, Jeong-hoon;Park, Sung Goo;Park, Byoung Chul;Kweon, Gi Ryang;Yim, Yong-Hyeon
    • Mass Spectrometry Letters
    • /
    • 제6권3호
    • /
    • pp.71-74
    • /
    • 2015
  • Low temperature plasma (LTP) ionization mass spectrometry (MS) is one of the widely used ambient analysis methods which allows soft-ionization and rapid analysis of samples in ambient condition with minimal or no sample preparation. One of the major advantages of LTP MS is selective analysis of low-molecular weight, volatile and low- to medium-polarity analytes in a sample. On the contrary, the selectivity for particular class of compound also implies its limitation in general analysis. One of the critical factors limiting LTP ionization efficiency is poor desorption of analytes with low volatility. In this study, a home-built LTP ionization source with Peltier heating sample stage was constructed to enhance desorption and ionization efficiencies of analytes in a sample and its performance was evaluated using standard mixture containing fatty acid ethyl esters (FAEEs). It was also used to reproduce the previous bacterial identification experiment using pattern-recognition for FAEEs. Our result indicates, however, that the bacterial differentiation from FAEE pattern recognition using LTP ionization MS still has many limitations.

Effect of Ultrasonic Microdroplet Generation in the Low-Temperature Plasma Ionization-Mass Spectrometry

  • Lee, Hyoung Jun;Yim, Yong-Hyeon
    • Mass Spectrometry Letters
    • /
    • 제10권4호
    • /
    • pp.103-107
    • /
    • 2019
  • Low-temperature plasma (LTP) ionization is one of the ambient ionization methods typically used in mass spectrometry (MS) for fast screening of chemicals with minimal or no sample preparation. In spite of various advantages of LTP ionization method, including simple instrumentation and in-situ analysis, more general applications of the method are limited due to poor desorption of analytes with low volatilities and low ionization efficiencies in the negative ion mode. In order to overcome these limitations, an ultrasonic vibrator of a commercial hand-held humidifier was interfaced with an LTP ionization source, which generated microdroplets from sample solutions and assisted with LTP ionization. Ionization behaviors of various chemicals in microdroplet-assisted LTP (MA LTP) were tested and compared with typical LTP ionization from dried samples applied on a surface. MA LTP efficiently ionized small organic, amino, and fatty acids with low volatilities and high polarities, which were hardly ionized using the standard LTP method. Facile interaction of LTP with ultrafine droplets generated by ultrasonic resonator allows efficient ionization of relatively non-volatile and polar analytes both in the positive and negative ion modes.

Differential Rapid Screening of Phytochemicals by Leaf Spray Mass Spectrometry

  • Muller, Thomas;Cooks, R. Graham
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권3호
    • /
    • pp.919-924
    • /
    • 2014
  • Ambient ionization can be achieved by generating an electrospray directly from plant tissue ("leaf spray"). The resulting mass spectra are characteristic of ionizable phytochemicals in the plant material. By subtracting the leaf spray spectra recorded from the petals of two hibiscus species H. moscheutos and H. syriacus one gains rapid access to the metabolites that differ most in the two petals. One such compound was identified as the sambubioside of quercitin (or delphinidin) while others are known flavones. Major interest centered on a $C_{19}H_{29}NO_5$ compound that occurs only in the large H. moscheutos bloom. Attempts were made to characterize this compound by mass spectrometry alone as a test of such an approach. This showed that the compound is an alkaloid, assigned to the polyhydroxylated pyrrolidine class, and bound via a $C_3$ hydrocarbon unit to a monoterpene.

Direct Analysis in Real Time Mass Spectrometry: a Powerful Tool for Fast Analysis

  • Li, Xianjiang;Wang, Xin;Li, Linnan;Bai, Yu;Liu, Huwei
    • Mass Spectrometry Letters
    • /
    • 제6권1호
    • /
    • pp.1-6
    • /
    • 2015
  • Direct analysis in real time mass spectrometry (DART-MS) is one of the variants of ambient mass spectrometry. The ionization process of DART-MS is in open environment and only takes few seconds, so it is suitable for fast analysis. Actually, since its introduction in 2005, more and more attentions have been drawn to its various applications due to its excellent properties, e.g., fast analysis, and no or less sample preparation, high salt tolerance and so on. This review summarized the promising features of DART-MS, including its ionization mechanism, equipment modification, wide applications, coupling techniques and extraction strategies before analysis.

Fragmentation Behavior Studies of Chalcones Employing Direct Analysis in Real Time (DART)

  • Motiur Rahman, A.F.M.;Attwa, Mohamed W.;Ahmad, Pervez;Baseeruddin, Mohammad;Kadi, Adnan A.
    • Mass Spectrometry Letters
    • /
    • 제4권2호
    • /
    • pp.30-33
    • /
    • 2013
  • Chalcones are naturally occurring, biologically active molecules generating interest from a wide range of research applications including synthetic methodology development, biological activity investigation and studying fragmentation patterns. In this article, a series of chalcones has been synthesized and their fragmentation behavior was studied using modern ambient ionization technique Direct Analysis in Real Time (DART). DART ion source connected with an ion trap mass spectrometer was used for the fragmentation of various substituted chalcones. The chalcones were introduced to the DART source using a glass capillary without sample preparation step. All the chalcones showed prominent molecular ion peaks $[M]^{{\cdot}+}$ corresponding to the structures. Multistage mass spectral data $MS^n$ ($MS^2$ and $MS^3$) were collected for all the chalcones studied. The chalcones with substitutions at 3, 4 or 5 positions gave product ion peaks with the loss of a phenyl radical ($Ph^{\cdot}$) by radical initiated ${\alpha}$-cleavage, while substitution at 2 position of chalcone in the A-ring gave a product ion peak with the loss of substituted styryl radical (PhCH = $CH^{\cdot}$). In case of the chalcones with the substituent at 4 positions in A and B rings gave both types of fragmentation patterns. In conclusion, chalcones can be easily characterized using modern DART interface in very short time and efficiently without any cumbersome sample pretreatment.

선택적다중이온질량분석기를 이용한 대기 중 휘발성유기화합물 실시간 동시분석법 개발 및 적용 (Development of Real-time and Simultaneous Quantification of Volatile Organic Compounds in Ambient with SIFT-MS (Selected Ion Flow Tube-Mass Spectrometry))

  • 손현동;안준건;하성용;김기범;임운혁
    • 한국대기환경학회지
    • /
    • 제34권3호
    • /
    • pp.393-405
    • /
    • 2018
  • Volatile organic compounds (VOCs) are representative air pollutants due to their detrimental effects on human health and their role in formation of secondary organic aerosols. Assessments and monitoring programs of VOCs using periodic grab sampling like Tedlar bags, canisters, and sorbent traps provide limited information, often with delay times of days or weeks. Selected ion flow tube mass spectrometry (SIFT-MS) is an emerging analytical technique for the real-time quantification of VOCs in air. It relies on chemical ionization of the VOCs molecules in air introduced into helium carrier gas using $H_3O^+$, $NO^+$, and $O_2{^+}$ precursor ions. Real-time monitoring method of 60 VOCs in the ambient air was developed using TO-15 standard gas mixture. Calibration curves, method detection limit, and quantitation reproducibility of the target compounds were tested. Dynamic dilution system was used to dilute standard gas from 0.174 ppbv to 100 ppbv, where calibration curves showed good linearity with $r^2$> 0.95 in all target analytes. Limit of detection (LOD) all compounds were sub ppbv, and some halogenated compounds showed pptv levels. Seven consecutive analyses of target compounds showed good repeatability with relative standard deviation of less than 10%. One day monitoring of VOCs in ambient air was conducted in Geoje. Average concentration of target VOCs in Geoje were relatively lower than other regions, among which formaldehyde showed the highest concentration ($15.4{\pm}5.78ppbv$). SIFT-MS provided good temporal resolution data (1 data per 3.2 minute), which can be used for identifying ephemeral short-term event. It is expected that SIFT-MS will be a versatile monitoring platform for VOCs in ambient air.

Development of Ambient Ionization Mass Spectrometry Imaging for Live Cells and Tissues

  • 김재영;서은석;이선영;정강원;문대원
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2015년도 제49회 하계 정기학술대회 초록집
    • /
    • pp.229.1-229.1
    • /
    • 2015
  • 생체 시료인 세포나 조직을 분석을 위해 임의로 파괴하거나 훼손하지 않은 본래의 상태에서 세포에 존재하는 다양한 생체분자 물질의 질량과 조성을 분석하고 영상화할 수 있는 대기압 표면 질량분석 이미징 기술을 개발했다. 생체 시료의 표면을 질량 분석을 하기 위해서는 대기압 분위기에서 시료에 열적 손상이 없는 조건으로 시편의 이온화 및 탈착 과정이 이루어지게 하기 위해 저온 대기압 탈착/이온화원으로 저온대기압 플라즈마 젯과 펨토초 적외선 레이저를 결합하여 대기압 이온화원을 제작하였다. 기존에 잘 알려진 저온 대기압 플라즈마 젯 소자는 유리관에 방전기체를 흘려주고 전극에 고전압을 인가하는 방식으로 제작했으며, 또 다른 대기압 이온화원으로서 근적외선 대역의 고출력 펨토초 레이저 빔을 현미경용 대물렌즈로 집속하여 생체시료에 조사시켰다. 수백 나노미터에서 수 마이크로미터 수준으로 빔을 집속할 수 있는 펨토초 레이저는 금나노로드의 도움으로 생체 시료를 매우 작은 수준으로 탈착하는 데 주로 사용하며, 수십 마이크로미터에서 수 밀리미터 정도의 크기를 가지는 저온 대기압 플라즈마 젯은 탈착된 물질을 이온화시키는데 사용하여, 이 두 가지 이온화원을 결합하여 이온화원으로 사용한다. 시료에서 발생한 이온을 질량분석기 입구까지 잘 끌고 갈 수 있도록 이온 전달관을 설계하고 보조펌프를 장착 사용한다. 이렇게 자체 개발한 대기압 이온화원을 상용 질량분석기기와 결합하여 대기압 분위기에서 시료의 표면을 질량분석할 수 있는 시스템과 측정 기술을 개발했다. 현미경 스테이지에 정밀 2-D 자동 스캐닝 스테이지를 장착하여 질량분석 정보에 공간 정보를 더할 수 있는 질량분석 이미징 기술 방법을 개발하여 생체 시편의 질량분석 이미징을 얻었다. 수분을 포함하는 생채시료로부터 단백질, 지질, 대사물질을 직접 분리하여 분석하는 이 새로운 질량분석법은 기존의 분석법에 비해 훨씬 더 많은 생체분자 정보를 얻을 수 있으며 공간정보를 더해 영상화할 수 있는 큰 장점이 있다. 대기압 표면 질량분석 기술은 생체시료를 파괴해서 용액화할 필요도 없으며, 진공 챔버에 넣기 위해 필요한 복잡한 전처리 과정 단계를 간략화 할 수 있으며 최종적으로는 살아있는 세포나 생체 조직도 정량 분석이 가능하여 생명과학 및 의료진단 분야에서 응용할 수 있는 분야는 무궁무진할 것이다.

  • PDF

Phytochemical analysis of Panax species: a review

  • Yang, Yuangui;Ju, Zhengcai;Yang, Yingbo;Zhang, Yanhai;Yang, Li;Wang, Zhengtao
    • Journal of Ginseng Research
    • /
    • 제45권1호
    • /
    • pp.1-21
    • /
    • 2021
  • Panax species have gained numerous attentions because of their various biological effects on cardiovascular, kidney, reproductive diseases known for a long time. Recently, advanced analytical methods including thin layer chromatography, high-performance thin layer chromatography, gas chromatography, high-performance liquid chromatography, ultra-high performance liquid chromatography with tandem ultraviolet, diode array detector, evaporative light scattering detector, and mass detector, two-dimensional high-performance liquid chromatography, high speed counter-current chromatography, high speed centrifugal partition chromatography, micellar electrokinetic chromatography, high-performance anion-exchange chromatography, ambient ionization mass spectrometry, molecularly imprinted polymer, enzyme immunoassay, 1H-NMR, and infrared spectroscopy have been used to identify and evaluate chemical constituents in Panax species. Moreover, Soxhlet extraction, heat reflux extraction, ultrasonic extraction, solid phase extraction, microwave-assisted extraction, pressurized liquid extraction, enzyme-assisted extraction, acceleration solvent extraction, matrix solid phase dispersion extraction, and pulsed electric field are discussed. In this review, a total of 219 articles published from 1980 to 2018 are investigated. Panax species including P. notoginseng, P. quinquefolius, sand P. ginseng in the raw and processed forms from different parts, geographical origins, and growing times are studied. Furthermore, the potential biomarkers are screened through the previous articles. It is expected that the review can provide a fundamental for further studies.