• Title/Summary/Keyword: amalgam alloy

Search Result 50, Processing Time 0.032 seconds

A STUDY ON THE REDUCTION OF GALVANIC CURRENT BETWEEN AMALGAM AND GOLD ALLOY WITH VARIOUS CHEMICAL AGENTS (수종 아말감과 금합금의 갈바닉 전류 측정에 관한 연구)

  • Kim, Seung-Soo;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.2
    • /
    • pp.469-481
    • /
    • 1993
  • The purpose of this study was to achieve the reduction of the galvanic current between the dental amalgam alloy and gold alloy. In order to measure the galvanic current between these two metals a prep in the size of $4{\times}13mm$ which was filled with amalgam and another prep of $4{\times}2mm$ was filled with gold alloy was made in the acrylic resin. These two preps were then connected to a 2mm diameter copper wire. Using an ammeter to measure the galvanic current, six different kinds of amalgam and gold alloy were immersed in saline solution with approximately 10mm distance between the two alloys. Chemical agents that are thought to reduce the galvanic current such as hydrazine. silver nitrate, potassium chromate, and bonding agents such as Scotch bond 2(3M) and All bond 2(Bisco) were applied to the alloy surface. Cathodic inhibitor such as hydrazine was applied to gold alloy where as anodic inhibitor such as silver nitrate and potassium chromate were applied to amalgam. Both bonding agents, Scotch bond 2(3M) and All bond 2 (Bisco), were applied to amalgam. The following results were obtained when the currency on the coated alloy surface was compared to the uncoated surface. 1. The galvanic currency went down as the time elapsed and after 30 minutes no change was detected. 2. Initial currency was higher in low copper amalgam compared to high copper amalgam. Intitial currency was the highest in low copper lathe-cut amalgam. 3. Group of gold coated with hydrazine had the most reduction in galvanic currency. 4. Group of amalgam coated with silver nitrate or potassium chromate also showed significant reduction in galvanic currency. 5. The bonding agents also helped reduce galvanic currency. 6. Of all the agents used to reduce galvanic currency, silver nitrate showed the best result.

  • PDF

A Study on Corrosion according to Distance between Amalgam and Dissimilar Metals (아말감과 이종(異種)금속의 거리에 따른 부식에 대한 고찰)

  • Kim, Ju-won;Jeong, Eun-gyeong
    • Journal of dental hygiene science
    • /
    • v.4 no.3
    • /
    • pp.103-109
    • /
    • 2004
  • The present study prepared 72 test samples - 24 made of amalgam alloy, 24 of Verabond (Ni-Cr alloy) for crown and 24 of Talladium $^{TM}alloy$ for denture - according to the manufacturers' manuals and general method in consideration of the width of the mesial-distal dental crown of the lower $1^{st}$ molar and MOD cavity in clinics, put them in a 200 ml beaker containing 80 ml of artificial saliva, and measured their galvanic corrosion at distances of 0 mm, 7 mm and 40 mm after 7 days. Isolated metals in the electrolyte such as Cu, Ag, Ni, Cr, Sn, Zn and Hg were quantitatively analyzed with Inductively Coupled Plasma - Atomic Emission Spectrometer (ICP-AES, JY-50P, VG Elemental Co. France), and from the results were drawn conclusions as follows. First, Cu, Sn, Ag, Hg and Zn were highly advantageous when amalgam contacted gold alloy compared to Ni-Cr alloy for crown and Talladium alloy for denture. In addition, although gold alloy was finest in terms of oral tissue and biocompatibility, it was most disadvantageous when it was with amalgam. Second, when amalgam contacted gold alloy, heavy metals such as Ni and Cr were not isolated at all because gold alloy did not contain such elements but Sn was isolated as much as $227.1{\pm}18.0035{\mu}g/cm^2$ although it was not included in the composition either. Hg was also isolated. These elements are assumed to have been isolated from amalgam itself. Third, when amalgam alloy was apart from gold alloy 0 mm, 7 mm and 40 mm, Cu and Ag showed significance but Hg did not. This suggests that gold alloy must not be used together with amalgam, and must not be used between dissimilar prostheses regardless of distance. Fourth, when amalgam alloy contacted Ni-Cr alloy for crown, Ag was not isolated from the amalgam, but Zn, Ni, Sn, Hg and Cu were isolated in order of quantity. Significance was observed according to distance - 0 mm, 7 mm and 40 mm. Hg was not isolated but heavy metals Ni and Cr were isolated. If amalgam alloy was in the opposite arch or it was apart from Ni-Cr alloy for crown, the isolation Hg was less than that when amalgam alloy contacted Ni-Cr alloy for crown. Fifth, when amalgam alloy contacted Talladium alloy for denture, significance was observed at distances of 0mm, 7 mm and 40 mm. Hg was not isolated but heavy metals Ni and Cr were isolated. If amalgam alloy was in the opposite arch or it was apart from Talladium alloy for denture, the isolation Hg was less than that when amalgam alloy contacted Talladium alloy for denture. Sixth, according to the result of ICPES test on Cu, Sn, Ag, Hg, Zn, Ni and Cr of amalgam alloy, gold ally, Verabond and Talladium alloy when these alloys contacted artificial saliva, significance was observed in Cu and Hg. Seventh, when amalgam alloy contracted two non-precious metals Ni-Cr alloy for crown and Talladium alloy for denture in artificial saliva, significance was observed in the isolated by-products of Hg, Ni and Cr according to distance.

  • PDF

A STUDY ON THE MICROSTRUCTURES OF THE AMALGAM ALLOYS AND AMALGAMS (치과용 아말감합금 및 아말감의 마세구조에 관한 연구)

  • Yeon, Sang-Heum;Lee, Chung-Sik;Lee, Myung-Jong;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.1
    • /
    • pp.87-105
    • /
    • 1996
  • The purpose of this study is to investigate the characteristics of the compositions and phases of amalgam alloys and amalgams by using EMPA and X-ray diffractometer. Each specimen was made from Caulk Fine Cut Clow copper lathe cut amalgam), Caulk Spherical (low copper spherical amalgam), Tytin (high copper unicorn position amalgam), Dispersally (high copper admixed amalgam) and Valiant (Palladium enriched amalgam). For preparing amalgam alloys, Tytin and Valiant were used as powder forms and the others were used as tablet forms after being polished with polishing machine. For preparing amalgams, each amalgam alloy and Hg were measured, and triturated by mechanical amalgamater according to user's instructions. After triturating, the triturated mass was inserted to cylindrical metal mold and simultaneously adapted by cylindrical condenser with same diameter and condensed by Instron universal testing machine with 80kg pressure & 1mm/min speed. Each specimen was removed from the metal mold and stored at room temperature for a week. The specimen was polished with the same polishing machine for amalgam alloy. For observation of microstructure and analysis of composition of amalgam alloys and amalgams, EMPA was used to get secondary electron images, backscattered images and characteristic X-ray images of Ag, Sn, Cu, Zn, Hg. To analyze compositions of amalgam alloys and amalgams, X-ray diffractometer was used. Amalgam alloys were scanned at the range of 2${\theta}$ of 30-$85^{\circ}$ and the speed of $4^{\circ}$/min with Cuka line and amalgams were scanned at the range of 2${\theta}$ of 28-$44^{\circ}$ and the speed of $4^{\circ}$/min with Cuka line. By comparing obtained d(distance between surfaces) and d of expected phases and atoms in amalgam alloys and amalgams in ASTM card, phases and atoms were identified. The results were as follows, 1. In Caulk Fine Cut amalgam alloy typical ${\gamma}$ phase was shown, and in amalgam, ${\gamma}$, ${\gamma}_1$ and ${\gamma}_2$ phases were observed. 2. In Caulk Spherical amalgam alloy ${\gamma}$, Ag, Cu and $\varepsilon$ phases were shown, and in amalgam ${\gamma}$, ${\gamma}_1$, ${\gamma}_2$ and $\eta$ phases were observed. 3. In Tytin amalgam alloy ${\gamma}$, Cu and $\varepsilon$ phases were shown, and in amalgam ${\gamma}$, ${\gamma}_1$, $\eta$ and $\varepsilon$ phases were observed. 4. In Dispersalloy ${\gamma}$, Ag, Cu and $\varepsilon$ phases were shown, and in amalgam ${\gamma}$, ${\gamma}_1$, $\eta$ and $\varepsilon$ phases were observed. 5. In Valiant alloy ${\gamma}$, Cu and e phases were shown, and in amalgam ${\gamma}$, ${\gamma}_1$, $\eta$ and $\varepsilon$ phases were observed.

  • PDF

EXPERIMENTAL STUDY ON THE DISSOLUTION COMPONENTS AND CORROSION PRODUCTS OF SEVERAL AMALGAMS IN ARTIFICIAL SALIVA (인공타액에서 수종 아말감의 부식시 용해성분 및 표면 부식 생성물에 관한 실험적 연구)

  • Cho, Seung-Joo;Lee, Myung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.1
    • /
    • pp.1-26
    • /
    • 1994
  • The purpose of this study was to investigate the dissolution components during corrosion of amalgams and to identify surface corrosion products in the modified Fusayama artificial saliva. Four type of amalgam alloys were used: low copper lathe cut amalgam alloy (Cavex 68), low copper spherical amalgam alloy (Caulk Spherical Alloy), high copper admixed amalgam alloy (Dispersalloy) and high copper single composition amalgam alloy (Tytin). Each amalgam alloy and Hg were triturated according to the manufacturer's direction by means of mechanical amalgamator (Capmaster, S.S.White), and then the triturated mass was inserted into the cylindrical metal mold which was 10mm in diameter and 2.0mm in height and condensed with compression of 150kg/$cm^2$ using oil pressor. The specimens were removed from the mold and stored at room temperature for 7 days and cleansed with distiled water for 30 minutes in an ultrasonic cleaner. The specimens were immersed in the modified Fusayama artificial saliva for the periods of 1 month, 3 months and 6 months. The amounts of Hg, Cu, Sn and Zn dissolved from each amalgam specimen immersed in the artificial saliva for the periods of 1 month, 3 months and 6 months were measured using Inductivity Coupled Plasma Atomic Emission Spectrometry (ICPQ-1000, Shimadzu, Japan) and amount of Ag dissolved from amalgam specimen was measured using Atomic Absorption Spectrophotometry (Atomic Absorption/Flame emission spectrophotometer M-670, Shimadzu, Japan). A surface corrosion products of specimens were analysed using Electron Spectroscopy Chemical Analyser (ESCA PHI-558, PERKIN ELMER, U.S.A.). The secondary image and back scattered image of corroded surface of specimens was observed under the SEM, and the corroded surface of specimens was analysed with the EDX. The following results were obtained. 1. The dissolution amount of Cu was the most in high copper admixed amalgam(Dispersalloy) and the least in high copper single composition amalgam(Tytin). 2. Sn and Zn were dissolved during all the experiment periods, and dissolution amounts were decreased as the time elapsed. 3. Initial surface corrosion products were ZnO and SnO. 4. Corrosion of ${\gamma}$ and ${\gamma}_2$ phase in low copper amalgams was observed and Ag-Cu eutectic alloy phase was corroded in low copper spherical amalgam(Caulk Sperical Alloy). 5. Corrosion of ${\gamma}$ and $\eta$' phase in high copper amalgams was observed and Ag-Cu eutectic alloy phase was corroded in high copper admixed amalgam(Dispersalloy). 6. Sn-Cl was produced in the subsurface of low copper amalgams and high copper admixed amalgam.

  • PDF

분산형 Amalgam에 대한 임상적 연구

  • Sunoo, Young-Gook
    • The Journal of the Korean dental association
    • /
    • v.18 no.2 s.131
    • /
    • pp.115-119
    • /
    • 1980
  • The purpose of this study was to observe clinical behavior on a national dispersant amalgam alloy, KISTCAP which newly developed by the KIST (Korea Instute for Science and Technology) in Korea. The results were as follows: 1. There was no significant difference in manipulating between the above mentioned alloy and the conventional lathe cut alloy. 2. The condensation pressure for this alloy was relatively less than that of conventional one. 3. More time was needed to polish the surface of this amalgam filling body than the conventional one. 4. No notable difference was seen in the over-all clinical behavior between the Whitecap and kistcap, except the latter one showed a little more tendency in redish color.

  • PDF

A Study on occurrence of porosity and leakage of mercury in dental amalgam's inside (치과용 아말감 내부의 수은 유출과 기포의 발생에 관한 연구)

  • Kim, Joo-Won
    • Journal of Korean society of Dental Hygiene
    • /
    • v.10 no.3
    • /
    • pp.531-540
    • /
    • 2010
  • Objectives : In this study, following the cavity restorations with low copper conventional alloy, high copper admixed one and high copper unicompositional one, which are used the most frequently in a clinical setting at the present, to experiment the time-dependent changes of strength, bubbles were examined. Besides, to examine the detrimental effects of mercury contained in dental amalgam, the amount of mercury release was evaluated. Methods : As dental amalgams which were used herein, [BESTALOY], [Hi-Aristaloy 21] and [Sybraloy] were selected for a low-copper conventional amalgam, a high-copper admixed one and a high-copper unicompositional one in the corresponding order. The formation of bubbles and the weight ratio of mercury release were evaluated using a field emission scanning electron microscope (FE-SEM). Thus, the following results were obtained: Results : 1. The time-dependent amount of mercury release reached a statistical significance in three types of alloys, which was shown in such a descending order as [BESTALOY], [Hi-Aristaloy 21] and [Sybraloy]. 2. A low-copper conventional type, BESTALOY is a cutting type and it was found to have an increased formation of fine bubbles. In the remaining two types, [Hi-Aristaloy 21] (a high-copper admixed alloy) and [Sybraloy] (a high-copper unicompositional alloy), the time-dependent changes in the formation of bubbles was negligible. Conclusions : Accordingly, this type of mercury release from amalgam alloy denotes the difference in the weight ratio of total constituents between after 24 hours and after two weeks. But further studies are warranted to examine the amount of mercury release which is detrimental to human bodies. Besides, a low-copper conventional alloy is a cutting type and it was characterized by the abundant formation of bubbles in a time-dependent manner. This implies that the strength of amalgam is impaired, which should be considered in selecting the appropriate amalgam alloy in a clinical setting.

COMPARISON OF THE PHYSICAL PROPERTIES BETWEEN GALLIUM ALLOY AND HIGH COPPER AMALGAM ALLOYS (갈륨합금과 고동 아말감 합금의 물리적 성질 비교)

  • Kim, Hyeon-Cheol;Lee, Hee-Joo;Hur, Bock
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.278-287
    • /
    • 1998
  • The purpose of this study was to compare the physical properties between high copper amalgam and gallium restorative material. In this study, the specimens for the 4 experimatal groups (Valiant, Valiant PhD, Gallium Alloy GF II. Gallium Alloy GF II triturated with some addition of alcohol) were prepared in the manner of which stated in ADA specification No.1 for amalgam alloy. And then, measured and compared the value of compressive strength. creep, and dimensional change during hardening of each sample. The results were as follows: 1. In the compressive strength, the Valiant-lathe cut type high copper amalgam-had the highest value of strength(p<0.05), and the Valiant PhD-admixed type high copper amalgam-showed the higher value of strength than the Gallium Alloy GF II(p<0.05) but had no significant difference with Gallium Alloy GF II triturated with some addition of alcohol(p>0.05). 2. In the creep. the Valiant PhD showed the highest value of creep (p<0.05), but there was no significant difference between Gallium Alloy GF II and Valiant(p>0.05). 3. In the dimensional change during hardening, no two groups were significantly different at the 0.050 level. 4. There was no significant difference between Gallium Alloy GF II and the same material which was triturated with some addition of alcohol(p>0.05).

  • PDF

A STUDY ON THE MICROSTRUCTURE TRANSFORMATION IN SPHERICAL-DISPERSED TYPE AMALGAM (아말감충전물(充塡物)의 미세구조(微細構造) 변화(變化)에 관(關)한 연구(硏究))

  • Chang, Sang-Kohn;Min, Byeong-Sun;Park, Sang-Jin;Choi, Ho-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.9 no.1
    • /
    • pp.81-87
    • /
    • 1983
  • The purpose of this study was to observe and identify the phases of amalgam and to know the transformation of microstructure in the set amalgam by lapse of time. In this study, shofu spherical-D alloy was used. After trituration of amalgam alloy and mercury (Wig-L-Bug), it was filled in the stone dies. This specimens being polished and etched by usual method was observed under optical microscope using metallurgical microscope. And then X-ray diffractometer was used to analyze the phases contents and transformation of microstructure at $2{\frac{1}{2}}$ hours, 15 hours, 28 hours and 2 years after being amalgamated. The following results were obtained: 1. Shofu spherical-D alloy powder was composed of ${\gamma}$ phase, ${\epsilon}$phase and Ag-Cu eutectic phases. 2. ${\gamma}_2$ phases were appeared at $2{\theta}$ values ($32.0^{\circ}$ and $43.8^{\circ}$) in the amalgam which was analyzed at $2{\frac{1}{2}}$ hours and 15 hours after trituration with mercury. 3. In the amalgam at 28 hours, ${\gamma}_2$ phase was found at $2{\theta}$ value ($43.8^{\circ}$) at 35 hour, $r_2$ phase was appeared at $2{\theta}$ value $32.0^{\circ}$. 4. No ${\gamma}_2$ phases were observed in the 2 years old amalgam. But ${\eta}$ ($Cu_6Sn_5$) phases were found at $2{\eta}$ values $29.4^{\circ}$ and $42.4^{\circ}$.

  • PDF

A STUDY ON THE GALVANIC CURRENT BETWEEN GOLD AND AMALGAM (아말감과 금합금의 Galvanic 전류 측정에 관한 실험적 연구)

  • Kim, Yeoung-Nam;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.10 no.1
    • /
    • pp.63-70
    • /
    • 1984
  • It was the purpose of this study to determine the galvanic current between a gold alloy inlay and four types of amalgam using the circuit through pulp chambers when the freshly extracted teeth with those restorations were brought into contact in a physiologic saline solution, and to investigate the effectiveness of cavity varnish or ammonated silver-nitrate on the surface of amalgam restoration in reducing galvanic current. The current was measured with current-to-voltage converter and recored on a physiograph 6630-257. The following results were obtained. 1. Generally, galvanic current decreased as the time elapsed. 2. Galvainc current decreased significantly in the first day and after then minimal change was observed until 30th day. 3. Initial galvanic current was 29.6 ${\mu}A$ in the cut amalgam and 24.5 ${\mu}A$ in Dispersalloy amalgam and after then the current was significantly decreased. 4. Initial galvanic current was 12.6 ${\mu}A$ in spherical amalgam (low copper amalgam) and 13.8 ${\mu}A$ in Tytin amalgam and the amount of change was lower in sperical amalgam and Tytin amalgam than that in lathe cut amalgam and Dispersalloy amalgam. 5. Painting ammoniated silver-nitrate or Copalite on the surface of amalgam resotration decreased initial galvanic current and ammoniated silver-nitrate is more effective in decreasing galvanic current than Copalite. 6. Galvanic current by contact between amalgam restoration and gold restoration increased abruptly and dropped rapidly becoming almost.

  • PDF

A COMPARATIVE STUDY ON THE MICROLEAKAGE OF THE AMALGAM AND GALLIUM ALLOY (아말감과 갈륨알로이의 미세 변연 누출에 관한 비교 연구)

  • Kim, Jung-Wook
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.2
    • /
    • pp.323-334
    • /
    • 1998
  • The purpose of this study was to compare the microleakage of the amalgam and the gallium alloy when several lining materials were applied. The ANA 2000, high copper lathecut type amalgam(AM group) and Gallium Alloy GF II (GF group) were used. The fifty extracted sound molars were randomly assigned to AM group and GF group, and the buccal and lingual class V cavities with a size $3{\times}2{\times}2mm$ were prepared. The prepared cavities were randomly assigned to group 1 : no liner used control, group 2 : Copalite, group 3 : Panavia 21, group 4 : All-bond 2, and group 5 : Superbond C&B. After liner placement and amalgam filling, the specimens were stored in $37^{\circ}C$ normal saline for 24 hours and then thermocycled from $5^{\circ}C$ to $55^{\circ}C$ thousand times. The specimens were stored in the 1% methylene blue solution for 24 hours and sectioned and examined by stereomicroscope. The results obtained from this study can be summarized as follows : 1. In the GF group, microleakage values of group 2, 3, 4, 5 were significantly lower than that of group 1 (p<0.05). 2. In the AM group, microleakage values of group 3 and 4 were significantly lower than that of group 1 (p<0.05), but microleakage values of group 2 and 5 did not differ from that of group 1 (p>0.05). 3. The GF group was similar(group, 1 3, 4) or superior(group 2, 5) to the AM group in the aspect of the microleakage.

  • PDF