• 제목/요약/키워드: alternating over-current

검색결과 31건 처리시간 0.032초

Characteristics of ZnO Arrester Blocks Leakage Currents under Mixed Direct and 60 Hz Alternating Voltages (직류와 60 Hz 교류가 중첩된 전압에 대한 산화아연 피뢰기 소자의 누설전류 특성)

  • Lee Bok-Hee;Kang Sung-Man;Pak Keon-Young
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • 제54권1호
    • /
    • pp.23-29
    • /
    • 2005
  • This paper presents the characteristics of leakage currents flowing through ZinC Oxide(ZnO) surge arrester blocks under mixed direct and 60 Hz alternating voltages. A mixed voltage, in which an alternating voltage is superimposed upon a direct voltage, appears on the HVDC system network. The mixed direct and alternating voltage generator with a peak open-circuit of 10 kV was designed and fabricated. The leakage currents and V-I curves for the fine and used ZnO surge arrester blocks were measured as a function of the voltage ratio k, where the voltage ratio k is defined as the ratio of the peak of alternating voltage to the peak of the mixed voltages. The resistive component in the leakage current in the low conduction region is significantly increased with increasing the voltage ratio k. The V-I characteristic curves for the mixed voltages lies between the direct and alternating characteristics, and the cross-over phenomenon in the high conduction region was appeared.

A study on the safe operation condition for Bi-2223/Ag tapes with applied alternating currents (교류용 Bi-2223/Ag 선재의 안정 통전 조건에 관한 연구)

  • Yim S. W.;Sohn S. H.;Hwang S. D.;Lim S. H.
    • Progress in Superconductivity
    • /
    • 제6권2호
    • /
    • pp.138-141
    • /
    • 2005
  • Bi-2223/Ag tapes need to be safe, even it is under the over-critical current state for the protection of a superconducting power machine. However, it is not easy to identify the condition for the safe operation because of their broad S/N transition region. In this paper, for the study of the operation condition of Bi-2223/ Ag tapes, we investigated the V-I curves and the temperature variation of Bi-2223/ Ag tapes experimentally, applying alternating over-currents, and analyzed the relationship between resistance and temperature increase. For the experiments, a Bi-2223/Ag tape of 57 A $I_c$ was prepared, and the over-critical current characteristics under adiabatic state from $LN_2$ was measured. From the experiments, we confirmed that the Joule heating predicted by V-I curve corresponded with the increase of the measured temperature exactly. Using the results, a safe operation condition of Bi-2223 tape was discussed.

  • PDF

DC Current sensor using the saturable magnetic cores (자성체포화를 이용한 DC전류센서)

  • Park, Y.T.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.699-702
    • /
    • 2002
  • A DC current sensor is disclosed in which two pairs of saturable cores are provided so as enclose a conductor carrying a direct current to be measured. On each of the saturable cores, a bias winding, a feedback winding and an output winding are wound. Circuit for detection of an asymmetry in the magnetization current, generated by a reference alternating voltage, in a signal-conditioner. The reference alternating voltage is fed to the respective series circuits such that no resultant induction current is induced in the modulating current. The voltages over the resistor form input signals for two peak value detectors, the strength of the output signal of which represents the degree of asymmetry of magnetization current. This paper describes the development a DC current sensor and its signal-conditioner.

  • PDF

Corrosion Rate of Buried Pipeline by Alternating Current

  • Song, H.S.;Kim, Y.G.;Lee, S.M.;Kho, Y.T.;Park, Y.S.
    • Corrosion Science and Technology
    • /
    • 제4권1호
    • /
    • pp.1-7
    • /
    • 2005
  • An alternating current (AC) corrosion on buried pipeline has been studied using coupon and ER probe. Coupons and ER probes were applied to the sites from high value of AC voltage to low value based on the survey of AC voltages on buried gas transmission pipeline over the country. Parameters such as AC current density of coupon, AC voltage, cathodic protection potential, soil resistivity and frequency were monitored continually. Corrosion induced by AC was observed even under cathodically protected condition that met cathodic protection criterion (; below -850 mV vs. CSE). Corrosion rate was affected mainly not by AC voltage but by both of frequency and AC current density. An experimental corrosion rate relation could be obtained according to effective AC current density, in which AC corrosion rate increased linearly with effective AC current density, and its slope was 0.619 in coupon method and 0.885 in ER probes.

Corrosion Rate of Buried Pipeline by Induced Alternating Current (교류가 유도되는 매설배관에서의 교류 부식속도 측정에 관한 연구)

  • Song H. S.;Kim Y. G.;Lee S. M.;Kho Y. T.;Park Y. S.
    • 한국가스학회:학술대회논문집
    • /
    • 한국가스학회 2001년도 추계학술발표회 논문집
    • /
    • pp.45-57
    • /
    • 2001
  • An alternating current (AC) corrosion using coupon has been studied. Coupons were applied in terms of AC voltage from high value to low value through the survey of AC voltages on buried gas transmission pipeline over the country. Parameters such as AC current density of coupon, AC voltage, cathodic protection potential, soil resistivity and frequency were monitored continually. Corrosion induced by AC was observed even under cathodically protected condition that met cathodic protection criterion(: below -850mv vs. CSE). Corrosion rate was affected mainly not by AC voltage but by both of frequency and AC current density. An experimental corrosion rate relationship could be obtained statistically, in which AC corrosion rate increased linearly with effective AC current density and its slope was 0.619.

  • PDF

Analysis on Current Distribution in Bi-2223/Ag Tapes with Applied Alternating Over-critical Current

  • Yim, Seong-Woo;Kim, Hye-Rim;Hwang, Si-Dole
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • 제17권6호
    • /
    • pp.678-682
    • /
    • 2004
  • Generally Bi-2223/Ag tapes have a broad S/N transition region and their sheath is a good electric conductor. In this study, the current distribution between superconductor and metal sheath in HTS tapes were investigated. AC with its peak value above 10 times $I_{c}$ was applied to HTS tapes for around 6 cycles and V-I characteristics were measured. Using the resistance of the sheath and V-I curves, the current distribution between superconductor and metal sheath was calculated. When 150 $A_{p}$ was applied, more than 2/3 of the current flows through superconductor. However, in the case of 304 $A_{p}$, most of the applied current came to flow through the metal sheath at the 6th cycle.e.e.e.

Electrical Behaviors of ZnO Elements under Combined Direct and Alternating Voltages

  • Yang, Soon-Man;Lee, Bok-Hee;Paek, Seung-Kwon
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권1호
    • /
    • pp.111-117
    • /
    • 2009
  • This paper presents the characteristics of leakage currents flowing through zinc oxide (ZnO) surge arrester elements under the combined direct-current (DC) and 60 Hz alternating-current (AC) voltages. The current-voltage characteristic curves (I-V curves) of the commercial ZnO surge arrester elements were obtained as a function of the voltage ratio a. At constant peak value of the combined DC and AC voltage, the resistive leakage current of the ZnO blocks was significantly increased as the voltage ratio $\alpha$ increased. The I-V curves under the combined DC and AC voltages were placed between the pure DC and AC characteristics, and the cross-over phenomenon in both the I-V curves and R-V curves was observed at the low current region. The ZnO power dissipation for DC voltages was less than that for AC voltage in the pre-breakdown region and reversed at higher voltages.

A Study of the Charging Current Effect on Underground Distribution Line in Electric Railway (전철 지중배전선로의 충전전류보상에 관한 연구)

  • Kim, Yang-Su;Jang, Woo-Jin
    • Proceedings of the KSR Conference
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.214-218
    • /
    • 2008
  • Because on the high-tension underground distribution line of an electric railway high voltage XLPE Cable two or three circuits between railway stations with a standard as receiving transformer facilities are established at a $30km{\sim}50km$ interval, reactive power in which the phase of a current is larger than that of a voltage is supplied when trains are not working, so when there are no loading or low loading as night. Due to the long-distance trend of the underground distribution system on an alternating current railway distribution line, the terminal voltage of a transformer is over the standard voltage, and after all, commercial cycle overvoltage is continued. To solve this problem, the shunt reactor is installed in middle of power distribution lines to maintain receiver voltage meted under the allowance regulation through control of the reactive power. Also, in case that the thickness of single cable is over $60mm^2$ and length of line is about over 30km, a circuit breaker is broken by shorting shunt ability of charging current in excess of shunt current(31.5A.rms). Therefore, this thesis presents installing the location of shunt reactor for quantitative analysis by using optimum algorism for compensation and control of the charging current.

  • PDF

Development of Clamp Current Meter using a Flexible Rogowski Coil (Flexible Rogowski 코일을 이용한 클램프형 전류 센서의 개발)

  • Chang, Yong-Moo;Kim, Seong-Il
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.472-475
    • /
    • 2002
  • A Rogowski coil can measure alternating currents from a few amps to over 1 million amps in a frequency range from less than 0.1 Hz to about lMhz. A Rogowski coil provides an induced output voltage which is proportional to the rate of change of the primary current enclosed by the flexible or the rigid coil-loop. Therefore, it is necessary to integrate the output voltage in order to produce a voltage proportional to the current. Also. it can reproduce the current waveform on an oscilloscope or any type of data acquisition device. This paper describes the practical design of the combination of a Rogowski coil and an integrator which provides a versatile current measuring system to accommodate a wide range of frequencies, current levels and conductor sizes.

  • PDF

Detection of Metal Impurities at Aluminum processing factory (알루미늄 가공 현장에서 금속 불순물 검출)

  • Hwang, Jong-Myung;Ahn, Bu-Hwan;Lee, Jang-Myung
    • The Journal of Korea Robotics Society
    • /
    • 제4권4호
    • /
    • pp.320-326
    • /
    • 2009
  • This paper proposed a new magnetic field detection algorithm to detect metal pieces in food producing processes. This algorithm can detect mixed metal pieces by sensing magnetic field. Some metal pieces are passed through an over-current circuit to magnetize them. The magnetic field sensor can detect the change in the magnetic field on theconveyor belt caused by the flow of the metal pieces in the food product. However, such a method detects the output of signals that change their amplitude and phase according to the movement of the conveyor belt with the food product, in which the equilibrium of the positive signal that is created in the receiver coil loses its balance due to the magnetized material. This includes not only the signal elements resulting from the effect of the alternating magnetic fields of the mixed metals, but also the signal elements resulting from the effect of the alternating magnetic fields of the examined object itself.

  • PDF