• 제목/요약/키워드: alternating method

검색결과 432건 처리시간 0.031초

Combined BOLD fMRI and Transcranial Magnetic Stimulation Study: Evaluation of Ipsilateral Motor Pathway of Stroke Patients

  • 배성진;장용민;장성호;변우목;강덕식
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2001년도 제6차 학술대회 초록집
    • /
    • pp.104-104
    • /
    • 2001
  • Purpose: In this study, we investigated the possible motor pathways of hemiplegic stroke patients usin combined TMS and BOLD fMRI approach and evaluated the correlation between TMS a fMRI methods. Method: Four subjects, who demonstrated left hemiplegia after stroke, are included. TMS was performed using a Dantec Mag2 stimulator (Dantec Company, USA) in single puls mode with figure eight-shaped coil. Following TMS localization, The BOLD T2*-weight images were acquired with echo planar imaging sequence (TR = 1.2 sec, TE = 60 msec, and flip angle = 90). Motor activation was studied by means of a repetitive fing flexion-extension task. The stimulation protocol comprised 10 cycles of alternating activati and rest (10 images per cycle). Total 60 cycles were performed and each cycle take abou 1.5 sec. The resulting images were then analyzed with STIMULATE (CMRR, U, o Minnesota) to generate functional maps using a student t-test (p < 0.0005) and cluste analysis.

  • PDF

체결력에 따른 볼트 결합구조물의 응력집중계수 평가 (Estimation of stress concentration factor in bolt jointed structure with variable preload)

  • 송준혁
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1998년도 춘계학술대회 논문집
    • /
    • pp.298-303
    • /
    • 1998
  • Most of mechanical structures are combined of substructures such as beam and/or plates. There are few system with unibody structures but are not a few systems with united body structures. Generally the dynamic analysis of whole structures is perform ed under alternating load. However, the analysis of each joint area is more important than others for zero severity. This paper presents the results of analysis of concentration stress in bolt jointed structure with variable preload. At frist, a static vibration test was performed to find out a nominal stress of bolt joint ed plates from the relationship between natural frequency and nominal stress. Then a concentration stress was computed at contact point between bolt and plate in the structure. It is believed that the proposed method has promising implications for safer design with fatigue quality index of stress concentration factor and has merit for cost down and saving time at the beginning of vehicle development.

  • PDF

양휘산법 (楊輝算法) 에 제시된 연환도 (連環圖) 의 일반화 (A generalization of Yeonhwando in Yang Hui Suanfa)

  • 박교식
    • 한국수학사학회지
    • /
    • 제29권4호
    • /
    • pp.219-232
    • /
    • 2016
  • In this paper, the problem posed in Yeonhwando is presumed like the following: "Make the sum of eight numbers in each 13 octagons to be 292, and the sum of four numbers in each 12 squares to be 146 using every numbers once from 1 to 72." Regarding this problem, in this paper, firstly, it is commented that there can be a lot of derived solutions from the Yang Hui's solution. Secondly, the Yang Hui's solution is generalized by using sequence 1 in which the sum of neighbouring two numbers are 73, 73-x by turns, and sequence 2 in which the sum of neighbouring two numbers are 73, 73+x by turns. Thirdly, the Yang Hui's solution is generalized by using the alternating method.

고분자복합소재차체를 적용한 바이모달트램의 전기적 절연 및 접지시스템에 관한 연구 (Study about Electrical Insulation and earthing system of Bimodal Tram with Polymer Composite Body)

  • 이강원;목재균;길경석;박대원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1063-1064
    • /
    • 2008
  • Bimodal tram has a carbody made of polymer composite material which is good electrical insulator. As an series hybrid type, Alternating voltage generated from generator coupled with CNG engine are rectified and transformed to variable voltage ranges which are applied to electrical apparatus and ECUs equipped inside of the tram. The failures of electrical insulation between high voltage($400V{\sim}800V$) and low voltage(24V) or between different kind of voltages such as AC and DC may cause some electrical interferences to prevent from operating rightly and other safety problem. This paper have investigated about the degradation factors of the electrical insulation and the earthing method available to bimodal tram, which is effective for preventing the electromagnetic interference coming from the inside or outside of tram but need some detecting measurements of earth leakage through electrical systems.

  • PDF

유전알고리즘과 CFD기법을 이용한 터빈블레이드 경사각 최적화 (Leaning Angle Optimization of the Turbine Blade using the Genetic Algorithm and CFD method)

  • 이은석;정용현
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.413-414
    • /
    • 2008
  • Abstract should be in English. The leaning angle optimization of turbine blade using the genetic algorithm was conducted in this paper. The calculation CFD technique was based upon the Diagonalized Alternating Directional Implicit scheme(DADI) with algebraic turbulencemodeling. The leaning angle of VKI turbine blade was represented using B-spline curve. The control points are the design variable. Genetic algorithm was taken into account as an optimization tool. The objective was to minimize the total pressure loss. The optimized final geometry shows the better aerodynamic performance compared with the initial turbine blade.

  • PDF

Si 모재 위의 $Si_xGe_{1-x}$ 박막에서 부정합 전위와 임계두께에 관한 연구 (Study on Misfit Dislocations and Critical Thickness in a $Si_xGe_{1-x}$ Epitaxial Film on a Si Substrate)

  • 신정훈;김재현;엄윤용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.298-303
    • /
    • 2001
  • The critical thickness of an epitaxial film on a substrate in electronic or optoelectronic devices is studied on the basis of equilibrium dislocation analysis. Two geometric models, a single dislocation and an array of dislocations in heteroepitaxial system, are considered respectively to calculate the misfit dislocation formation energy. The isotropic linearly elastic stress fields for the models are obtained by means of complex potential method combined with alternating technique, and are used for calculating the formation energies. As a result, the effect of elastic mismatch between film and substrate on critical thickness is presented and $Si_xGe_{1-x}/Si$ epitaxial structure is analyzed to predict the critical thickness with varying germanium concentration.

  • PDF

Control Algorithms of Large Synchronous Machines for Starting Gas Turbosets

  • Hwang, Seon-Hwan;Kim, Jang-Mok;Ryu, Ho-Seon;Yoon, Gi-Gab
    • Journal of Power Electronics
    • /
    • 제9권2호
    • /
    • pp.146-155
    • /
    • 2009
  • The static frequency converter (SFC) systems are used as a method of driving large synchronous machines in many power and industrial plants. In this paper, new control algorithms of SFC systems for starting gas turbo sets are proposed for a four quadrant operation: start-up at standstill; an acceleration up to the speed of the rated voltage; field weakening to reach the rated speed; synchronization to the main alternating current (AC) source; and dynamic braking to stop safely within the rating of the synchronous machine. Experimental results show that the proposed algorithms are proper and effective.

Ag/AsGeSeS 다층박막의 광유기 이방성(PA) 특성 (Characteristics of the photoinduced anisotropy(PA) in Ag/AsGeSeS multilayer thin films)

  • 박종화;나선웅;여철호;박정일;이영종;정홍배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.362-365
    • /
    • 2001
  • The chalcogenide glasses of thin films have the superior property of photoinduced anisotrophy(PA). In this study, we observed the linear dichroism(D) using the irradiation with polarized He-Ne laser light, in the $Ag/As_{40}Ge_{10}Se_{15}S_{35}$ multi-layer. Mutilayer structures formed by alternating metal(Ag) a chalcogenide$(As_{40}Ge_{10}Se_{15}S_{35})$. Such multilayer structures have a greater sensitivity to illumination am larger dichroism in comparison the conventional double layer structure. Also new phenomena are discovered. These results will be show a capability of new method that suggested more improvement of photoinduced anisotropy property.

  • PDF

The Measurement of Maxwell Displacement Current of Phospholipid Monolayers on the Water Surface

  • Park, Keun-Ho
    • 한국응용과학기술학회지
    • /
    • 제14권2호
    • /
    • pp.35-40
    • /
    • 1997
  • The organization of phospholipid monolayers and their monolayers mixed with fatty acid containing azobenzene on the water surface was investigated by means of the displacement current measurement method. The phase transition from the gaseous phase to the gaseous-fluid phase which accompanies the polar ordering of phospholipid molecules was detected in the range of immeasurably low surface pressure. The molecular area which gives the onset of the transition was determined for phospholipid monolayers. The Maxwell displacement current(MDC) pulses were generated across mixed monolayers due to the photoisomerization of fatty acid containing azobenzene by alternating irradiation of ultraviolet and visible light, because the condensation of pure azobenzene monolayers was loosened by the introduction of phospholipids into the monolayers. The displacement currents generated during light irradiation were also investgated in connection with monolayer compression cycles. It was found that the maximum of MDC appeared at the molecular area just before the initial rise of surface pressure in compression cycles.

A Study of fracture Mechanics Analysis Methodology for Stress Corrosion Cracks in Pressure Component Weld feints

  • Park, June-soo;Kim, Jong-Min;Pak, Jai-hak;Jin, Tae-eun
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2003년도 춘계학술발표대회 개요집
    • /
    • pp.216-218
    • /
    • 2003
  • A fracture mechanics analysis methodology for stress corrosion cracks (SCCs) existing in the Alloy 600 nozzle weld joint for control rod drive mechanisms (CRDMs) of pressurized water reactor is studied. Effects of weld residual stresses on the sub-critical crack behavior during the reactor operation are investigated by a fracture mechanics analysis, which is combined with the finite element alternating method. It is found that effects f the residual stresses on the stress intensity factor (SIF) and crack growth rate (CGR) are dominant and values of SIF and CGR of cracks in the region of weld joint are increased by a factor of three or more on an average.

  • PDF