Solid Phase Crystallization of LPCVD Amorphous Silicon Thin Films by Alternating Magnetic Flux (교번자속인가에 의한 비정질 실리콘 박막의 결정화거동에 대한 연구)

  • 송아론;박상진;박성계;남승의;김형준
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.459-462
    • /
    • 2000
  • A new method for the fabrication of poly-Si films is reported using by alternating magnetic flux crystallization (AMFC) of LPCVD a-Si films. In this work we have studied the crystallization of LPCVD a-Si films by alternating magnetic flux. A-Si films were 1200$\AA$-thick deposited at 48$0^{\circ}C$ at a total pressure of 0.25Torr using Si$_2$H$_{6}$/H$_2$. After this step, these a-Si films were thermally annealed by Alternating Magnetic Flux at 43$0^{\circ}C$ for 1hours. The annealed films were characterized using X-ray diffraction (XRD), Raman Spectra, Atomic Force Microscopy(AFM). Both alternating magnetic flux crystallization and solid phase crystallization were investigated to compare enhanced crystallization a-Si. We have found that the low temperature crystallization method at 43$0^{\circ}C$ by alternating magnetic flux.x.

  • PDF

Effect of Alternating Magnetic Field on Ion Activation in Low Temperature Polycrystalline Silicon Technology

  • Hwang, Jin Ha;Lim, Tae Hyung
    • Journal of the Semiconductor & Display Technology
    • /
    • v.3 no.1
    • /
    • pp.35-39
    • /
    • 2004
  • Statistical design of experiments was successfully employed to investigate the effect of alternating magnetic field on activation of polycrystalline Si (p-Si) doped as n-type using $\textrm{PH}_3$, by full factorial design of three factors with two levels. In this design, the input variables are graphite size, alternating current, and activation time. The output parameter, sheet resistance, is analyzed in terms of the primary effects and multi-factor interactions. Notably, the three-factor interaction is calculated to be a dominant interaction. The interaction between graphite size and activation time and the main effect of current are important effects compared to the other variables and relevant interactions. Alternating magnetic flux activation is proved a significantly beneficial processing technique.

  • PDF

Analysis of Magnetic Field Behavior and Iron Loss in Stator Core of Permanent Magnet Type Motor (영구자석형 모터의 고정자 철심에서 자계의 거동 및 철손 분석)

  • Ha Kyung-Ho;Cha Sang-Yoon;Kim Jae-Kwan;Hong Jung-Pyo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.2
    • /
    • pp.76-82
    • /
    • 2006
  • This paper investigates the magnetic field behavior and its iron losses in the stator core using electrical steels. The analysis model is a brushless motor with the permanent magnet. The elliptical rotating and alternating flux distributions with non-sinusoidal waveform are obtained by Finite Element Method and then their harmonic components are extracted. Based on these results, the local iron losses in the stator core caused by the harmonic flux are calculated. And then this paper explains the relation between flux waveform and iron loss produced in each part of the stator core. Furthermore, the iron loss at no load condition is measured and compared with the analysis results.

Determination of stress intensity factor by means of ACPD technique for ferromagnetic materials (교류전위차법에 의한 강자성체의 응력확대계수 결정)

  • Lee, Jeong-Hee
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.9
    • /
    • pp.1392-1399
    • /
    • 1997
  • In order to determine the Mode I stress intensity factor ($K_1$) experimentally by means of the alternating current potential drop(ACPD) technique, the change in potential drop due to load for a ferromagnetic material containing a two-dimensional surface crack was examined. The cause of the change in potential drop and the effect of the magnetic flux on the change in potential drop were clarified by using the measuring systems with and without removing the magnetic flux from the circumference of the specimen. To remove the magnetic flux, a new measuring system was made by utilizing the characteristic of coaxial transmission line. The change in potential drop in the case without magnetic flux in the air was caused by the change in electromagnetic properties near the crack tip due to magnetization. The relationship between the change in potential drop and the change in $K_I$ was linealized by demagnetization and was found to be independent of the crack length.

Analysis on the alternating torque characteristics of capacitor motor with windings not in quadrature (비대칭축콘덴서 전동기의 진동토오크 특성의 해석)

  • 오경열
    • 전기의세계
    • /
    • v.26 no.4
    • /
    • pp.41-53
    • /
    • 1977
  • With the equivalent series circuit analyzed aby revolving field theory and drawn by using the equivalent circuit constant ratios in capacitor motor with windings not in quadrature having space harmonics in its magnetic field (the above ratios are the equivalent circuit constants for the fundamental flux to the magnetizing reactance of the circuit), the equation for the alternating torque with twice line freequency in the motor is directly derived, and the alternating torque is measured with the self-made stator vibration angle amplitude measuring apparatus that is composed of a pickup, filter, photoelectric pickoff etc. The measured values satisfactorily compared with computed values. The properties of the alternating torque characteristics for respective harmonic fluxes and the r5esultant alternating torque characteristic, the effects of the alternating torque characteristics for respective harmonic fluxes on the resultant alternating torque characteristic, the effects of the variation in the motor constants and the equivalent circuit constant ratios for the fundamental flux on the alternating torque characteristics for respective harmonic fluxes and the resultant alternating torque characteristic, are made clear, applying the equation. There exist the optimum values of the motor constants and the equivalent circuit constant ratios for the fundamental flux for decreasing the alternating torque, and the value could be determined in design by the method presented in this paper.

  • PDF

Experimental Research of Change in Magnetic Flux Density Due to Load for Measuring KI (응력확대계수측정을 위한 하중에 의한 자속밀도변화의 실험적 연구)

  • Lee, Jeong-Hee
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.7 no.1
    • /
    • pp.129-132
    • /
    • 2004
  • In order to determine the effective way of measuring the Mode I stress intensity factor, $K_I$, by means of the alternating current potential drop(ACPD) technique for a material containing a two-dimensional surface crack, the change in magnetic flux density above the cracked specimen surface was studied experimentally. The change in magnetic flux in the air above the cracked specimen made of aluminum alloy is measured by changing the load by four-point bending. The magnetic flux in the air is almost not changed by increasing the load in teh specimen. The change in potential drop due to load is not caused by the change in electro-motive force induced in the coiled measuring system. This experimental result agree to the result of theoretical analysis in reference 7).

  • PDF

2-Dimensional Magnetic Properties of Electrical Steel Sheet Under Rotating Magnetic Field (회전자계하 전기강판의 2차원 자기적 특성 분석)

  • Ha, Kyung-Ho;Kim, Ji-Hyun;Kwon, Oh-Yeoul;Cha, Sang-Yoon;Kim, Jae-Kwan;Takahashi, Norio
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.621-622
    • /
    • 2008
  • This paper deals with the magnetic properties under the rotational magnetic field on the electrical steel sheet by using Single Sheet Tester with two excitation coils. Actually, the magnetic flux of stator cores in running motors have the behaviour of rotating and alternating flux. In order to improve motor characteristics, it is require to estimate these magnetic properties. When the magnetic field vectors are rotating around in the plane of the sheet during one period of cycle, the magnetization properties and the core loss are measured and then, the results are compared with the magnetic properties obtained by the alternating magnetic fields.

  • PDF

Iron Loss Analysis Considering Excitation Conditions Under Alternating Magnetic Fields

  • Hong, Sun-Ki;Koh, Chang-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.3
    • /
    • pp.33-38
    • /
    • 2010
  • In this paper, the nature of iron loss in electrical steel during alternating field excitation is investigated more precisely. The exact definition of AC iron loss is cleared by accurately measuring the iron loss for conditions of both the sinusoidal magnetic field and sinusoidal magnetic flux density. The results of this approach to iron loss calculations in electrical steel are compared to experimentally-measured losses. In addition, an inverse hysteresis model considering eddy current loss was developed to analyze the iron loss when the input is the voltage source. With this model, the inrush current in the inductor or transformer as well as the iron loss can be calculated.

Dry Magnetic Particle Inspection of Ingot Cast Billets (강편 빌레트의 건식 자분 탐상)

  • Kim, Goo-Hwa;Lim, Zhong-Soo;Lee, Eui-Wan
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.16 no.3
    • /
    • pp.162-173
    • /
    • 1996
  • Dry magnetic particle inspection(MPI) was performed to detect the surface defects of steel ingot cast billets. Magnetic properties of several materials were characterized by the measurement of the B-H hysteresis curve. The inspection results were evaluated in terms of the magnetizing current, temperature, and the amount of magnetic particles applied to billets. Magnetic flux leakage near the defect site of interest was measured and compared with the results of calculation by the finite element method in the case of direct magnetizing current. Direct and alternating magnetizing currents for materials were deduced by the comparison of the inspections. Results of the magnetic particle inspection by direct magnetizing current were compared with those of finite element method calculations, which were verified by measuring magnetic leakage flux above the surface and the surface defects of the material. For square rods, due to the geometrical effect, the magnetic flux density at the edges along the length of the rods was about 30% of that at the center of rod face for a sufficiently large direct magnetizing current, while it was about 70% for an alternating magnetizing current. Thus, an alternating magnetizing current generates rather uniform magnetic flux density over the rods, except for the region on the face across about 10 mm from the edge. The attraction of the magnetic particle by the magnetic leakage field was nearly independent of the surface temperature of the billets up to $150^{\circ}C$. However, the temperature should have been limited below $60^{\circ}C$ for an effective fixing of gathered magnetic particles to the billet surface using methylene chloride. We also found that the amount of applied magnetic particles tremendously affected the detection capability.

  • PDF

Flux Loss and Neutron Diffraction Measurement Ag-sheathed Bi-2223 Tapes in terms of Flux Creep

  • Jang Mi-Hye
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.5
    • /
    • pp.204-210
    • /
    • 2005
  • Alternating current (AC) losses of two Bi-2223 ([Bi, Pb]: Sr: Ca: Cu: O = 2:2:2:3) tapes [(Tape I, un-twist-pitch) and the other with a twist-pitch of 10 mm (Tape II)] were measured and compared. These samples, produced by the powder-in-(Ag) tube (PIT) method, are multi-filamentary. Also, it's produced by non-twist and different twist pitch (8, 10, 13, 30, 50 and 70 mm). The critical current measurement was carried out under the environment in liquid Nitrogen and in zero-field by 4-probe method. Susceptibility measurements were conducted while cooling in a magnetic field. Flux loss measurements were conducted as a function of ramping rate, frequency and field direction. The AC flux loss increases as the twist-pitch of the tapes decreased, in agreement with the Norris Equation. Neutron-diffraction measurements have been carried out investigate the crystal structure, magnetic structures, and magnetic phase transitions in Bi-2223([Bi, Pb]:Sr:Ca:Cu:O)