• 제목/요약/키워드: alpha rendering

검색결과 22건 처리시간 0.018초

Effects of Systemic and Focal Hypoxia on the Activities of Rostral Ventrolateral Medullary Neurons in Cats

  • Yan, Hai-Dun;Kim, Charn;Kim, Ji-Mok;Lim, Won-Il;Kim, Sang-Jeong;Kim, Jun
    • The Korean Journal of Physiology
    • /
    • 제30권1호
    • /
    • pp.105-116
    • /
    • 1996
  • Rendering the brain ischemic would evoke the cerebral ischemic reflex which is characterized by an arterial pressor response, apnea and bradycardia. Since the rostral ventrolateral medulla (RVLM) is known to play a key role in the maintenance of normal cardiopulmonary activity, during the cerebral ischemic reflex some cardiac related cells should be excited and respiration related cells inhibited. In this context, the responses of RVLM neurons to systemie and focal hypoxia were analyzed in the present study. Twenty-five adult cats of either sex were anesthetized with ${\alpha}-chloralose$ and the single neuronal activities were identified from RVLM area. For the induction of focal hypoxia in the recording site, sodium cyanide was applied iontophoretically and for systemic hypoxia the animal was ventilated with nitrogen gas for a twenty-second period. Cellular activities were analyzed in terms of their discharge pattern and responses to the hypoxia by using post-stimulus time and single-pass time histograms. Of eighteen cardiac related cells recorded from the RVLM area, twelve cells were excited by iontophoresed sodium cyanide and of twenty-five respiration related cells, fourteen cells were excited by iontophoresed sodium cyanide. Remaining cells were either inhibited or unaffected. Eight of fifteen cells tested with iontophoresed sodium lactate were excited and remaining seven cells were inhibited. Systemic hypoxia induced by nitrogen gas inhalation elevated the arterial blood pressure, but excited, inhibited or unaffected the single neuronal activities. Some cells showed initial excitation followed by inhibition during the systemic hypoxia. Bilateral vagotomy resulted in a decrease of arterial pressor response to the systemic hypoxia, and a slight decrease in the rhythmicity related to cardiac and/or respiratory rhythms. The single neuronal responses to either systemic or focal hypoxia were not affected qualitatively by vagotomy. From the above results, it was concluded that the majority of the cardiac- and respiration- related neurons in the rostral ventrolateral medulla be excited by hypoxia, not through the mediation of peripheral chemoreceptors, and along with the remaining inhibited cells, all these cells be involved in the mediation of cerebral ischemic reflex.

  • PDF

가이드 수술용 템플릿을 위한 5축 정밀가공공정의 정확성에 관한 연구 (Accuracy of 5-axis precision milling for guided surgical template)

  • 박지만;이태경;정제교;김용;박은진;한종현;곽재영;김성균;허성주
    • 대한치과보철학회지
    • /
    • 제48권4호
    • /
    • pp.294-300
    • /
    • 2010
  • 연구 목적: 컴퓨터-가이드 임플란트 수술은 전통적인 방법에 비해 여러 가지 장점을 가진다. 본 연구의 목적은 가이드 수술용 템플릿 제작을 위한 좌표동기화 5축 정밀가 공공정의 정확도를 범용 CAD 소프트웨어를 통해 역설계공학의 방법으로 평가하는 것이다. 연구 재료 및 방법: 악궁 형태의 모형에 거타퍼쳐 스타핑을 매식한 10 개의 모형을 만들고 상부에 실리콘 인상재를 이용하여 인공치은을 덮어 스타핑의 위치를 보이지 않게 가렸다. 모형의 하면에 동기화를 위한 좌표동기화 형상을 만든 뒤 Cone beam CT에서 3차원 영상을 얻었다. 임플란트 계획 소프트웨어의 CT 이미지 상에서 매식된 스타핑과 동일한 방향으로 스타핑의 1/2 깊이까지 가상의 시술계획을 하고, 스타핑의 방향벡터와 저지점 (1/2지점) 데이터를 석고모형의 영상으로 좌표동기화 하였다. 이후 모형하면의 좌표동기화 형상을 이용하여 가공기기상의 좌표로 좌표변환을 통해 가공좌표동기화를 하였다. 5축 밀링머신의 좌표동기화판에 모형을 고정한 후, 동기화된 가공데이터에 의거하여 스타핑과 동일한 직경의 드릴로 계획된 벡터와 깊이로 정확히 가공 하였다. 모델에 정확히 안착되는 인상트레이를 CT 장비에 미리 고정한 상태에서, 인상트레이에 모델을 적합하여 이미지를 획득한 뒤 3차원 재구성하는 방법으로 영상을 중첩하여 비교 분석하였다. SolidWorks (Dassault Systems, Concord, USA) 범용 CAD 상에 영상을 불러들여 역설계공학의 방법으로 실린더 상부, 하부의 중점에서의 위치편차와 각도편차를 조사하였다. 통계는 SPSS (release 14.0, SPSS Inc., Chicago, USA)를 이용하여 각 편차 사이의 상관관계를 분석하였다 ($\alpha$ = 0.05). 결과: 위치 편차로 인하여 모든 드릴 보어 (bore)에서 상부 1/2에 잔존하는 거타퍼쳐의 일부를 관찰할 수 있었다. 실험 모형상에서 계획된 이미지와 드릴링 후CT에서 역설계를 거친 이미지 사이의 위치편차는 상부에서 0.31 (0.15 - 0.42) mm, 하부에서 0.36 (0.24 - 0.51) mm, 각도편차는 1.62 (0.54 - 2.27)$^{\circ}$이었다. 실린더 상부와 하부 위치 편차는 양의 상관관계를 가졌다 (Pearson Correlation Coeffocient = 0.904, P= .013). 결론: 좌표동기화 5축 정밀가공 공정은 가이드 수술용 템플릿을 제작하는 데에 적합한 정확도를 가진다.