• Title/Summary/Keyword: allowable level

Search Result 335, Processing Time 0.025 seconds

The Analysis of Protection Ratio and Its Effect of Interference-to-Noise Ratio for Digital Microwave System with Diversity

  • Suh Kyoung-Whoan;Jang Won-Gyu
    • Journal of electromagnetic engineering and science
    • /
    • v.6 no.3
    • /
    • pp.189-195
    • /
    • 2006
  • In this paper, the derivation of the protection ratio for the digital microwave system with diversity is newly suggested for a basic guidance of initial planning for frequency coordination, and computational results are presented for an actual radio frequency band. The net filter discrimination has been also examined to see the effect of the adjacent channel protection ratio caused by adjacent channel interference. In addition, the protection ratios for the space or frequency diversity system are analyzed in terms of diversity improvement factors to find out an equivalent allowable noise-to-interference ratio (N/I) from degraded fade margin. According to results for 6.2 GHz system, with the space diversity of 25 m distance between antennas or the frequency diversity of ${\Delta}f/f=0.05$, under 64-QAM and 60 km at BER $10^{-6}$, the protection ratio can be greatly reduced in comparison to the non-diversity system. So, assuming that only the same protection ratio as the non-diversity system is kept, it is shown that the system with diversity may get more interference level of N/I allowing from 9.0 to - 5.9 dB or from 6.0 to - 4.3 dB for the space or frequency diversity. In consequence, it is concluded that the diversity system is more robust or tolerable for interferences or fades, which may play an important role in overcoming N/I to some extent.

EVALUATION OF THE APPLICABLE REACTIVITY RANGE OF A REACTIVITY COMPUTER FOR A CANDU-6 REACTOR

  • Lee, Eun Ki;Park, Dong Hwan;Lee, Whan Soo
    • Nuclear Engineering and Technology
    • /
    • v.46 no.2
    • /
    • pp.183-194
    • /
    • 2014
  • Recently, a CANDU digital reactivity computer system (CDRCS) to measure the worth of the liquid zone controller in a CANDU-6 was developed and successfully applied to a physics test of refurbished Wolsong Unit 1. In advance of using the CDRCS, its measureable reactivity range should be investigated and confirmed. There are two reasons for this investigation. First, the CANDU-6 has a larger reactor and smaller excore detectors than a general PWR and consequently the measured reactivity is likely to reflect the peripheral power variation only, not the whole core. The second reason is photo neutrons generated from the interaction of the moderator and gamma-rays, which are never considered in a PWR. To evaluate the limitations of the CDRCS, several tens of three-dimensional steady and transient simulations were performed. The simulated detector signals were used to obtain the dynamic reactivity. The difference between the dynamic reactivity and the static worth increases in line with the water level changes. The maximum allowable reactivity was determined to be 1.4 mk in the case of CANDU-6 by confining the difference to less than 1%.

A Hybrid Approach to Information System Sizing and Selection using Simulation and Genetic Algorithm (시뮬레이션과 유전 알고리즘의 하이브리드 기법을 이용한 정보시스템 용량 산정 및 선택 방안)

  • Min, Jae-H.;Chang, Sung-Woo;Shin, Kyung-Shik
    • Korean Management Science Review
    • /
    • v.24 no.2
    • /
    • pp.143-155
    • /
    • 2007
  • The purpose of this paper is to develop a new method for information system sizing and selection based on a hybrid mixture of simulation and genetic algorithm, and to show its cost-effectiveness by applying it to a real world problem. To serve this purpose, we propose an operational model which identifies a set of system alternatives using simulation, and determines the optimal one using genetic algorithm. Specifically, with simulation, we generate probability distributions describing real data gathered from actual system, which can overcome the major weakness of the existing methodology that normally employs point estimates of the actual data and constant correction factors without theoretical rationale. We next search for the optimal combination of H/W, the number of CPUs, and S/W, which meets both of our business goals of incurring low TCO(total cost of ownership) and maintaining a good level of transaction processing performance. Experimental result shows the proposed method in this paper saves the cost while it preserves the system's capacity within allowable performance range.

A Study on Fisheries Management of Ecosystem-Based TAC using a Linear Programming (선형계획법을 이용한 생태계 기반 TAC 어업관리에 관한 연구)

  • Seo, Young-Il;Cheon, Seong-Hoon;Kim, Do-Hoon
    • The Journal of Fisheries Business Administration
    • /
    • v.45 no.2
    • /
    • pp.61-72
    • /
    • 2014
  • This study aimed to empirically investigate the applicability of ecosystem-based TAC (Total Allowable Catch) fisheries management targeting the large purse seine fishery where multi-species are regulated by TAC. Using a linear programming, the optimal fishing effort and the catch amount by species which maximize fishing profits were analyzed under the constraint condition of catch limits by species. Analytical results showed that an application of TAC on only chub mackerel would have negative impacts on fish stocks such as hairtail and jack mackerel by increasing the level of fishing effort to achieve its allocated catch limit. However, under the constraint condition of catch limits of all species, it was shown that optimal catches of all species were achieved within their catch limits. It implies the importance of ecosystem-based management considering biological and technical interactions of species those were excluded in the traditional single species fisheries management.

Energy extraction system using dual-capacitor switching for quench protection of HTS magnet

  • Choi, Yojong;Lee, Woo Seung;Song, Seunghyun;Jeon, Haeryong;Kang, Hyoungku;Ko, Tae Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.19 no.3
    • /
    • pp.49-53
    • /
    • 2017
  • The superconducting magnets have a large inductance as well as high operating current. Therefore, mega-joule scale energy can be stored in the magnet. The energy stored in the magnet is sufficient to damage the magnet when a quench occurs. Quench heater and dump resistor can be used to protect the magnet. However, using quench heater to create quench resistors through heat transfer can be slower than instantly switching resistors. Also, electrical short, overheating and breakdown can occur due to quench heater. Moreover, the number of dump resistor should be limited to avoid large terminal voltage. Therefore, in this paper, we propose a quench protection method for extracting the energy stored in a magnet by charging and discharging energy through a capacitor switching without increasing resistance. The simulation results show that the proposed system has a faster current decay within the allowable voltage level.

Evaluating the TAC Policy in the Sandfish Stock Rebuilding Plan (도루묵 수산자원회복계획에서의 TAC정책 평가)

  • Kim, Do-Hoon
    • The Journal of Fisheries Business Administration
    • /
    • v.46 no.1
    • /
    • pp.29-39
    • /
    • 2015
  • This study aimed to evaluate the TAC policy and to examine the effective annual TAC quota in the sandfish stock rebuilding plan using a bioeconomic modelling method. In the analysis, first, a sandfish bioeconomic model was developed by combining a sandfish stock population model and economic models by fishery and second, achieving stock rebuilding targets and changes of fishing revenues by the level of annual TAC quota were examined. Model results indicated that the TAC 1,500ton policy would have the greatest impact on the increase of sandfish stock biomass comparing to the status quo and other TAC policies. In addition, it was evaluated that the total fishing revenues of coastal gillnet and danish seine fisheries could be increased the most in the TAC 2,500ton policy. In both cases of TAC 3,500ton and 4,000ton, the fishing revenues of both fisheries were inversely reduced due to the decrease of catch by coastal gillnet and the decline of market prices by danish seine's excessive catch. Furthermore, they would have a negative impact on sandfish stock biomass.

Antimicrobial Effect of Buffered Sodium Citrate (BSC) on Foodborne Pathogens in Liquid Media and Ground Beef

  • Ryu, Si-Hyun;Fung, Daniel -Y. C.
    • Preventive Nutrition and Food Science
    • /
    • v.15 no.3
    • /
    • pp.239-243
    • /
    • 2010
  • The antimicrobial effects of a commercially available, buffered sodium citrate (BSC) were evaluated for the reduction of total aerobic bacteria count, Salmonella Typhimurium, Escherichia coli O157:H7, Listeria monocytogenes and Staphylococcus aureus in a liquid medium and ground beef. BSC at 0, 1, 2 and 4.8% (wt/vol) or 0, 3, and 4.8% (wt/wt) was mixed into inoculated brain heart infusion (BHI) broth and ground beef (80% lean), respectively. BSC at concentrations of 1 and 2% did not inhibit growth of the pathogens tested in BHI broth. E. coli O157:H7 in BHI broth with 4.8% BSC was significantly reduced (p<0.05) by 3~4 log CFU/mL compared with the control for up to 4 days. At 4.8%, BSC treatment of ground beef most significantly reduced (p<0.05) total aerobic count and E. coli O157:H7 by 2.1 and 2.0 log CFU/g, respectively. This study indicates that the legally allowable level of 1.3% (wt/wt) BSC is not effective for reducing the pathogens tested in ground beef stored at $7^{\circ}C$.

The Countermeasure about Harmonics of the High Voltage Power Facilities (고압수전설비의 고조파에 관한 대책)

  • Kim, Ju-Chan;Sin, Su-Han;Lee, Chung-Sik;Koh, Hee-Seog
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.353-357
    • /
    • 2004
  • This paper presents the result of survey of case study for harmonics in electrical installations of buildings. Recently, many power electronic equipments(power converter, computers, air conditioners electronic ballasts for fluorescent lamps and so on) are used in office buildings, and harmonic current from them influence the other equipments in a distribution line. Notably, voltage distortion or voltage harmonics may approach or exceed is allowable level in power distribution system. Individual electric power consumers and end-users and responsible for reducing current harmonics while companies or utilities are responsible for reducing voltage harmonics at the point of common coupling in distribution system. As for harmonics, which one of the electric power qualities, it becomes important to obtain harmonic voltage/current distribution of the power system precisely because the use of power electronic apparatus in increasing. To suppress harmonics in electrical ins tallations of buildings, one of many methods suggest that resonance frequencies are controlled by modulating the capacities of high-voltage customer's capacitors.

  • PDF

A Case Study of Harmonics in Electrical Installations of Buildings (건축물 전기설비의 고조파에 관한 사례연구)

  • 고희석;김성삼;이현무;김주찬;류희석
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.283-288
    • /
    • 2003
  • This paper presents the result of survey of case study for Harmonics in electrical Installations of buildings. Recently, many power electronic equipments(power converter, computers, air conditioners electronic ballasts for fluorescent lamps and so on) are used in office buildings, and harmonic current from them influence the other equipments in a distribution line. Notably, voltage distortion or voltage harmonics may approach or exceed is allowable level in power distribution system. Individual electric power consumers and end-users and responsible for reducing current harmonics while companies or utilities are responsible for reducing voltage harmonics at the point of common coupling in distribution system. As for harmonics, which one of the electric power qualities, it becomes important to obtain harmonic voltage/current distribution of the power system precisely because the use of power electronic apparatus in increasing. However, there are some difficulties on evaluating the measured data in comparison with the simulated result. The primary cause was indentitied with the resonance of harmonics form many sources. To suppress harmonics in electrical installations of buildings, one of many methods suggest that resonance frequencies are controlled by modulating the capacities of high-voltage customer's capacitors.

  • PDF

FxLMS Algorithm for Active Vibration Control of Structure By Using Inertial Damper with Displacement Constraint (관성형 능동 댐퍼를 이용한 구조물 진동 제어에서 댐퍼 질량의 변위 제한을 고려한 FxLMS 알고리즘)

  • Kang, Min Sig
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.24 no.5
    • /
    • pp.545-557
    • /
    • 2021
  • Engine is the main source of vibration that generates unwanted noise and vibration of vehicle chassis. Especially, in submarine applications, radiation of noise signatures can be detected at some distance away from the submarine using a sonar array. Thus quiet operation is crucial for submarine's survivability. This study addresses reduction of the force transmissibility originating from engines and transmitted to hull through engine mounts. An inertial damper, as an actuator of hybrid mount system, is addressed to reduce even further the level of vibration. Narrow band FxLMS algorithms are broadly used to cancel the vibration of engine mount because of its excellent performance of canceling narrow band noise. However, in real active dampers, the maximum displacement of damper mass is kinematically restricted. When the control input signal from the FxLMS algorithm exceeds this limitation, the damper mass will collide with the mechanical stops and results in many problems. Originated from these, a modified narrow band FxLMS algorithm based on the equalizer technique with the maximum allowable displacement of active damper mass is proposed in this study. Some simulation results showed that the propose algorithm is effective to suppress vibration of engine mount while ensuring given displacement constraint.