• 제목/요약/키워드: alkaline corrosion

검색결과 92건 처리시간 0.025초

강재의 마그네타이트 피복에 관한 연구 (Magnetite film on iron)

  • 김헌규;강탁
    • 한국표면공학회지
    • /
    • 제25권2호
    • /
    • pp.66-72
    • /
    • 1992
  • Magnetite film on iron surface could be coated in strongly alkaline solution (12M NaH\OH) which contained additives such as NaHCO3, KCl and NaNO2, Iron plate was immersed in boiling solution ($130^{\circ}C$) contained above mentioned additives for 1 hour. There are some microcracks and these cracks proved to be the sites for the initiation of corrosion when immersed in 3% NaCl solution. To improve corrosion resistance of the coated steel plate, chromating was done as a post treatment. Chromate film was formed on magnetite oxide film potentiostatically at-918mV/SCE for five minutes at temperature of $70^{\circ}C$ in the alkaline solution containing 5g/l Na2Cr2O7.2H2O.Cr3O4 was electrodeposited on magnetite oxide film and Cr2O3 was electrodeposited on iron surface which was assumed as surface revealed due to microcracks. Increased corrosion resistance of chromated magnetite oxide film was proved in salt spray test & immersion test.

  • PDF

Effect of Corrosion Conditions on the Luster Change of Metallic Yarns and Fabric - Analysis of Changes in Reflection and Transmission -

  • Shin, Hye-Sun;Kim, Jong-Jun;Jeon, Dong-Won
    • 패션비즈니스
    • /
    • 제12권3호
    • /
    • pp.54-61
    • /
    • 2008
  • The glitter of lame fabrics containing the metallic yarns may further be altered by $Na_2CO_3$ aqueous solution at an elevated temperature. In this study, the effect of the corrosion treatment on the yarn luster was evaluated using image analysis. The alkaline solution treatment was found to be more effective on the aluminum-based specimens than on the silver-based specimens. It was found that corrosion percentage measurement based on the transmission analysis may provide reasonable quantitative index, even if the measurement relies on an indirect method. Based on the quantitative results, the alkaline treatment condition for the specific specimen would be optimized for a desired glitter modification.

SD460 철근의 세라믹 코팅에 의한 내식성 향상연구 (Corrosion Resistance of SD460 Reinforcing Rod by Ceramic Coating)

  • 박기용;이종권;홍석우
    • Corrosion Science and Technology
    • /
    • 제8권4호
    • /
    • pp.157-161
    • /
    • 2009
  • The corrosion resistance of reinforcing bar was studied to endure the marine environment during shipment. The red rust on the surface did not damage the adherence in the concrete structures, especially in highly alkaline environment, but made the consumer doubt of the quality. The passivation process by alkalization of the quenching water in the tempcore process failed to endure the long shipping period. The ceramic coating by sol-gel process improved the corrosion resistance without damaging the mechanical properties and adherence between concrete and reinfiorcing bar. Optimal concentration of the coating solution and coating temperature were tested. No additional energy was necessary for the coating process by spraying during cooling process, resulting simplified process and low cost. Salt spray test, cyclic corrosion test and atmospheric test were employed to confirm the resistance. The corrosion rates were presented by rating number and polarization resistance. The coating layer was examined by FIB, XRD and SEM etc.

Evaluation of Nonchromated Thin Organic Coatings for Corrosion Inhibition of Electrogalvanized Steel

  • Park, Jong Myung;Kim, Kyoo Young
    • Corrosion Science and Technology
    • /
    • 제6권2호
    • /
    • pp.68-73
    • /
    • 2007
  • The toxicity of chromium that is used to impart corrosion resistance to galvanized steel created environmental and health-related concerns and generated a great deal of interest in developing chrome-free treatment coatings. In the present work, organic-inorganic composite coatings were used to coat electrogalvanized steel (EG) sheets for corrosion protection without degrading its weldability property. The new coatings composed of specially modified polyurethane dispersion hybridized with silicate and unique inorganic-organic inhibitors were developed during this work. It was found that about $1{\mu}m$ thickness of coating layer is secure enough in corrosion resistance of flat and formed part even after alkaline degreasing. Overall chemical resistances including fingerprint resistance and paint adhesion property were satisfied with the test specification of Sony technical standard of SS-00260-2002. Therefore, it is concluded that the newly developed chrome-free product can replace the conventional chromated product.

Sorption characteristics of iodide on chalcocite and mackinawite under pH variations in alkaline conditions

  • Park, Chung-Kyun;Park, Tae-Jin;Lee, Seung-Yeop;Lee, Jae-Kwang
    • Nuclear Engineering and Technology
    • /
    • 제51권4호
    • /
    • pp.1041-1046
    • /
    • 2019
  • In terms of long-term safety for radioactive waste disposal, the anionic iodide (I-129) with a long half-life ($1.6{\times}10^6yr$) is of a critical importance because this radionuclide migrates in geological media with limited interactions. Various studies have been performed to retard the iodide migration. Recently, some minerals that are likely generated from waste container corrosion, have been suggested to have a considerable chemical interaction with iodide. In this study, chalcocite and mackinawite were selected as candidate minerals for underground corrosion materials, and an iodide sorption experiment were carried out. The experiment was performed under anoxic and alkaline conditions and the pH effects on the iodide sorption were investigated in the range of pH 8 to 12. The results showed that both minerals demonstrated a noticeable sorption capacity on iodide, and the distribution coefficient ($K_d$) decreased as the pH increased in the experimental condition. In addition, when the alkalinity increased higher than a pH of 12, the sorption capacity of both minerals decreased dramatically, likely due to the competition of hydroxy ions with the iodide. This result confirmed that chalcocite was an especially good sorbing media for iodide under alkaline conditions with a pH value of less than 12.

Characterizations of Precipitated Zinc Powder Produced by Selective Leaching Method

  • Marwa F. Abd;F. F. Sayyid;Sami I. Jafar Al-rubaiey
    • Corrosion Science and Technology
    • /
    • 제23권1호
    • /
    • pp.54-63
    • /
    • 2024
  • This work investigated the influence of concentration and applied potential on the characteristics of zinc powder (purity, apparent density, morphology, particle size distribution, and particle zeta potential) produced by the electrochemical process from waste brass. High-purity zinc powder is obtained using selective leaching of industrial brass waste in acidic, neutral, and alkaline solutions. The free immersion method with and without voltage using linear polarization technique is used. In the electrochemical process, hydrochloric acid HCl in three different concentrations (0.1, 0.2, and 0.3) M is used. The time and the distance between the electrodes are set to be 30 min and 3 cm, respectively. It has been found that the percentage purity is 98%, 96%, and 94% for the acidic, neutral, and alkaline solutions, respectively. In addition, the morphology of zinc powder analyzed by SEM was dendritic and mossy. It has been recorded that the purity of zinc increases with the increase of the concentration and applied potential. The highest value of purity for zinc powder was %98.58 in 1000 mV and 0.3M concentration for graphite cathode.

알칼리성 환경에서 부동태 피막 개선에 대한 양쪽성 이온 및 인산염 그룹을 갖는 염화물 이온의 역할 (Role of chloride ions with Zwitterions and phosphate groups on the improvement of the passive film in alkaline environment)

  • 트란득탄;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 봄 학술논문 발표대회
    • /
    • pp.43-44
    • /
    • 2022
  • In this study, the optimum amount of chloride ions is used to collaborate with hybrid corrosion inhibitor for carbon steel rebar treatment in simulated pore concrete (SCP) solution is discovered. The corrosion inhibition performance of hybrid inhibitors is carried on by open circuit potential (OCP), electrochemical impedance spectroscopy (EIS), and potentiodynamic polarization (PP). The highest corrosion inhibition resistance is found in case of LP-C2 after 240 h exposure. Surface studies including scanning electron microscopy (SEM), and atomic force microscopy (AFM) were used to figure out the surface morphology of the steel rebar treated with hybrid inhibitors in order to collaborate well with electrochemical studies. Anodic type inhibition action was confirmed by potentiodynamic polarization study.

  • PDF

Composite of Indium and Polysorbate 20 as Inhibitor for Zinc Corrosion in Alkaline Solution

  • Li, Xiaoping;Liang, Man;Zhou, Hebing;Huang, Qiming;Lv, Dongsheng;Li, Weishan
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권5호
    • /
    • pp.1566-1570
    • /
    • 2012
  • The combined use of indium and polysorbate 20 (Tween 20) was considered as a new inhibition technique for zinc corrosion. Zn and Zn-In alloy coatings were prepared by electrodeposition and their morphology and composition were characterized by scanning electron microscopy (SEM) and inductively coupled plasma atomic emission spectrometry (ICP-AES). The corrosion inhibition effect of indium and Tween 20 on zinc was investigated by polarization curves and electrochemical impedance spectroscopy (EIS). The corrosion inhibition efficiencies obtained from Tafel and EIS analyses are well in agreement. Zinc corrosion can be inhibited to some extent by the individual use of indium and Tween 20 and higher corrosion inhibition efficiency can be obtained by the combined use of indium and Tween 20.