• Title/Summary/Keyword: algebraic reconstruction technique

Search Result 30, Processing Time 0.026 seconds

Spray Measurement Using Optical Line Patternator at High Ambient Pressure (광학 선형 패터네이터를 이용한 고압 환경 하에서의 분무 측정)

  • Koh Hyeonseok;Shin Sanghee;Yoon Youngbin
    • Journal of the Korean Society of Visualization
    • /
    • v.3 no.1
    • /
    • pp.63-70
    • /
    • 2005
  • Optical Line Patternator(OLP) has been applied to get a distribution of the spray at high ambient pressure. OLP is a combined technique of extinction measurement and image processing. The attenuated intensity of laser beam after traversing spray region was measured by using a photo-detector, and the line image of Mie-scattering was captured simultaneously in the path of each laser beam by using a CCD camera. The distribution of extinction coefficient in the spray is obtained by processing these data with the algebraic reconstruction technique. From the distribution of extinction coefficient, the surface distribution of spray can be reconstructed. OLP does not use laser sheet but use laser beam so that the noise effect of multiple scattering, caused by increasing number density of droplet in high pressure environment, is reduced drastically. OLP is expected as a suitable method which can investigate the characteristics of relatively large spray under the high pressure environment such as liquid rocket engine.

  • PDF

Development of Combined Optical System for Analysis of Impinging Butane Flame (충돌 부탄 화염의 분석을 위한 복합 광학 계측 기법 개발)

  • Baek, Seung-Hwan;Ahn, Seong-Soo;Ko, Han-Seo
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.69-73
    • /
    • 2005
  • Three-dimensional density distributions of an impinging and eccentric flame have been analyzed numerically and experimentally by a combined optical system with a digital speckle tomography. The flame has been ignited by premixed butane/air from air holes and impinged vertically against a plate located at the upper side of tile burner nozzle. In order to compare with experimental data, computer synthesized phantoms of impinging and eccentric flames have been made and reconstructed by a developed three-dimensional multiplicative algebraic reconstruction technique (MART). A new scanning technique has been developed for the analysis of speckle displacements to investigate wall jet regions of the impinging flame including sharp variation of the flow direction and pressure gradient. The reconstructed temperatures have been compared with a temperature photography by an infrared camera and results of numerical analysis using a finite-element method.

  • PDF

Tomography Reconstruction of Ionospheric Electron Density with Empirical Orthonormal Functions Using Korea GNSS Network

  • Hong, Junseok;Kim, Yong Ha;Chung, Jong-Kyun;Ssessanga, Nicholas;Kwak, Young-Sil
    • Journal of Astronomy and Space Sciences
    • /
    • v.34 no.1
    • /
    • pp.7-17
    • /
    • 2017
  • In South Korea, there are about 80 Global Positioning System (GPS) monitoring stations providing total electron content (TEC) every 10 min, which can be accessed through Korea Astronomy and Space Science Institute (KASI) for scientific use. We applied the computerized ionospheric tomography (CIT) algorithm to the TEC dataset from this GPS network for monitoring the regional ionosphere over South Korea. The algorithm utilizes multiplicative algebraic reconstruction technique (MART) with an initial condition of the latest International Reference Ionosphere-2016 model (IRI-2016). In order to reduce the number of unknown variables, the vertical profiles of electron density are expressed with a linear combination of empirical orthonormal functions (EOFs) that were derived from the IRI empirical profiles. Although the number of receiver sites is much smaller than that of Japan, the CIT algorithm yielded reasonable structure of the ionosphere over South Korea. We verified the CIT results with NmF2 from ionosondes in Icheon and Jeju and also with GPS TEC at the center of South Korea. In addition, the total time required for CIT calculation was only about 5 min, enabling the exploration of the vertical ionospheric structure in near real time.

Correction of Image Distortion and Coordinate Calibration of the x-ray three dimensional imaging system (X선 3차원 영상 시스템에서의 영상 왜곡 및 영상 좌표계 보정)

  • 노영준;김재완;조형석;전형조;김형철;주효남
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.413-413
    • /
    • 2000
  • In this paper, we propose a series of calibrations f3r the x-ray three dimensional imaging system. In the developed x-ray system, a three dimensional inner and outer shape of an object can be reconstructed out of two dimensional transmitted x-ray image set, which are acquired by projecting x-ray to the object from different views. To achieve this, a reconstruction algorithm which estimates and updates the three dimensional volume from x-ray images is developed. The algorithm is named as uniform and simultaneous algebraic reconstruction technique(USART) which is an iterative method estimating a 3D volume based on its projected images. In this method, it is assumed that the imaging conditions that are the relative positions between the x-ray sources, object and the image planes are blown. Practically it is not easy to know the three dimensional coordinate of the components of the system, since the x-ray is not visible and the image distortions are present due to the optical components in the system. In this paper, methods of correcting image distortions are present firstly. Then the coordinates of the x-ray systems are calibrated from the x-ray images of the grid pattern. Some experimental results on these calibrations are present and discussed.

  • PDF

Analysis of Unsteady and Asymmetric Flows Using Digital Speckle Tomography with Developed Integration Method (개발된 적분법을 포함하는 디지털 스펙클 토모그래피 기법을 이용한 비정상 비대칭 유동 분석)

  • Baek, Seung-Hwan;Kim, Yong-Jae;Ko, Han-Seo
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.517-518
    • /
    • 2006
  • Transient and asymmetric density distributions have been investigated by three-dimensional digital speckle tomography with a novel integration method. Multiple CCD images captured movements of speckles in three angles of view simultaneously because the flows were asymmetric and unsteady. The speckle movements which have been formed by a ground glass between no flow and downward butane flow from a circular half opening have been calculated by a cross-correlation tracking method so that those distances can be transferred to deflection angles of laser rays for density gradients. A novel integration method has been developed to obtain projection data from the deflection angles for the speckle tomography.'The three-dimensional density fields have been reconstructed from the accurate projection values by a real-time multiplicative algebraic reconstruction technique (MART) with the developed integration method.

  • PDF

Analysis of Density Distribution for Butane Using Three-dimentional and Real-time Digital Speckle Tomography (3차원 실시간 디지털 스페클 토모그래피를 이용한 부탄 밀도 분포 분석)

  • Go, Han-Seo;Park, Gwang-Hui;Kim, Yong-Jae
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1789-1794
    • /
    • 2003
  • Transient and asymmetric density distributions have been investigated by digital speckle tomography. Multiple CCD images captured movements of speckles in three angles of view simultaneously because the flows were asymmetric and transient. The speckle movements between no flow and downward butane flow from a circular half opening have been calculated by a cross-correlation tracking method so that those distances can be tranferred to deflection angles of laser rays for density gradients. The three-dimensional density fields have been reconstructed from the fringe shift by a real-time multiplicative algebraic reconstruction technique (MART).

  • PDF

A Tool for Reconstruction of the Sensitivity Encoded Data with Sensitivity Encoding (SENSE)

  • Yun, Sung-Dae;Song, Myung-Sung;Chung, Jun-Young;Park, Hyun-Wook
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.71-71
    • /
    • 2003
  • For fast MRI, the number of phase encoding steps has to be reduced. However, the reconstructed image is aliased if the phase encoding steps don't satisfy Nyquist sampling theory. SENSE is used in order to eliminate the aliasing effect as well as to reduce imaging time. SENSE is a linear algebraic technique applied to the multiple receiver data. In this study, we implement a tool to reconstruct the original image (SENSE image) with Sensitivity Encoding (SENSE)

  • PDF

3D Generic Vertebra Model for Computer Aided Diagnosis (컴퓨터를 이용한 의료 진단용 3차원 척추 제네릭 모델)

  • Lee, Ju-Sung;Baek, Seung-Yeob;Lee, Kun-Woo
    • Korean Journal of Computational Design and Engineering
    • /
    • v.15 no.4
    • /
    • pp.297-305
    • /
    • 2010
  • Medical image acquisition techniques such as CT and MRI have disadvantages in that the numerous time and efforts are needed. Furthermore, a great amount of radiation exposure is an inherent proberty of the CT imaging technique, a number of side-effects are expected from such method. To improve such conventional methods, a number of novel methods that can obtain 3D medical images from a few X-ray images, such as algebraic reconstruction technique (ART), have been developed. Such methods deform a generic model of the internal body part and fit them into the X-ray images to obtain the 3D model; the initial shape, therefore, affects the entire fitting process in a great deal. From this fact, we propose a novel method that can generate a 3D vertebraic generic model based on the statistical database of CT scans in this study. Moreover, we also discuss a method to generate patient-tailored generic model using the facts obtained from the statistical analysis. To do so, the mesh topologies of CT-scanned 3D vertebra models are modified to be identical to each other, and the database is constructed based on them. Furthermore, from the results of a statistical analysis on the database, the tendency of shape distribution is characterized, and the modeling parameters are extracted. By using these modeling parameters for generating the patient-tailored generic model, the computational speed and accuracy of ART can greatly be improved. Furthermore, although this study only includes an application to the C1 (Atlas) vertebra, the entire framework of our method can be applied to other body parts generally. Therefore, it is expected that the proposed method can benefit the various medical imaging applications.

Development Of Four-Dimensional Digital Speckle Tomography For Experimental Analysis Of High-Speed Helium Jet Flow (고속 헬륨 제트 유동의 실험적 분석을 위한 4차원 디지털 스펙클 토모그래피 기법 개발)

  • Ko, Han-Seo;Kim, Yong-Jae
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.17 no.2
    • /
    • pp.193-203
    • /
    • 2006
  • A high-speed and initial helium jet flow has been analyzed by a developed four-dimensional digital speckle tomography. Multiple high-speed cameras have been used to capture movements of speckles in multiple angles of view simultaneously because a shape of a nozzle for the jet flow is asymmetric and the initial jet flow is fast and unsteady. The speckle movements between no flow and helium jet flow from the asymmetric nozzle controlled by a solenoid valve have been obtained by a cross-correlation tracking method so that those distances can be transferred to deflection angles of laser rays for density gradients. The four-dimensional density fields for the high-speed helium jet flow have been reconstructed from the deflection angles by a developed real-time tomography method.

2D Temperature Measurement of CT-TDLAS by Using Two-Ratios-of-Three-Peaks Algorithm (컴퓨터토모그래피 레이저흡수분광법(CT-TDLAS) 기반 2차원 온도분포 산정 Two-Ratios-of-Three-Peaks (2R3P) 알고리듬 개발)

  • CHOI, DOOWON;CHO, GYONGRAE;SHIM, JOONHWAN;DEGUCHI, YOSHIHIRO;KIM, DONGHYUK;DOH, DEOGHEE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.3
    • /
    • pp.318-327
    • /
    • 2016
  • In order to improve the performance of temperature field measurements by CT-TDLAS (Computer Tomography Tunable Diode Laser Absorption Spectroscopy), a new reconstruction algorithm, named two-ratios-of-three-peaks method is proposed in this paper. Further, two methods for selecting appropriate initial values of the iterative calculation of CT-TDLAS are proposed. One is MLOS (multiplicative line of sight) method and the other one is ALOS (additive line of sight) method. Two-ratios-of-three-peaks (2R3P) algorithm combined with MART (multiplicative algebraic reconstruction technique) is finally developed for the enhancements of reconstructive calculations. The results have been compared with those obtained by the conventional one-ratio-of-two-peaks (1R2P) algorithm. In order to evaluate the performance of this algorithm, numerical test has been performed using phantom Gaussian temperature distributions with $11{\times}11$ square mesh. The performance of the constructed algorithm has been demonstrated by comparing the results obtained in actual burner experiments with those obtained by thermocouples. It has been verified that 2R3P algorithm with MART and MLOS showed best performance than that of 1R2P algorithm.