• 제목/요약/키워드: airflow window system

검색결과 9건 처리시간 0.024초

공기식 집열창 시스템이 설치된 건물의 동적부하 해석 (Time Dependent Thermal Load Analysis of the Building with an Airflow Window System)

  • 조성환;박상동
    • 설비공학논문집
    • /
    • 제4권2호
    • /
    • pp.82-95
    • /
    • 1992
  • It has been known that the application of an airflow window system reduces the energy consumption compared with conventional double pane window in a building. But how to analyze thermal load in a building with an airflow window system has not been well known. so two kinds of method (Mode 1 and Mode 2) to analyze time dependent thermal load of the building with an airflow window system are presented in this study. The results of load analysis about the model building(total area : $4521m^2$, 3 floors) by Mode 2 show that the maximum cooling and heating load in a building with an airflow window system are decreased about 12-17% and about 19.5% than with double pane glass window, and yearly energy consumption with an airflow window system is saved about about 20% than with double pane glass window.

  • PDF

통합 시뮬레이션을 통한 리모델링용 이중창 시스템 기류 패턴 분석 (Airflow pattern of Double window system for Remodeling by using Integrated Simulation.)

  • 김은희;남현진;육인수;김정윤;김재민
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1036-1041
    • /
    • 2008
  • Double facade systems are often paid attention of as an effective energy saving measure for curtain wall buildings. However, it is not easy to install the system in existing buildings and requires substantial investment. An innovative double window system is proposed in this study which can be installed with exiting window systems in a cost effective way. the proposed system is connected to existing return ducts to make airflow between the existing window and the newly installed window. To ensure the best performance of the proposed system, simulation-based analysis was implemented in which airflow characteristics of inside double window were examined according to air pressures of return duct and window material by using computer simulation ESP-r. the overview of the proposed system and the results of the simulation-based analysis are presented in this paper.

  • PDF

배기식 3중 집열창의 열적 특성에 대한 수치해석 (Numerical analysis on the thermal characteristics of the exhaust triple-glazed airflow window)

  • 김무현;오창용
    • 설비공학논문집
    • /
    • 제12권1호
    • /
    • pp.40-49
    • /
    • 2000
  • The flow and heat transfer characteristics of the exhaust airflow window system were studied numerically by a finite volume method. Attention was paid to see the decrease in indoor cooling load. The exhaust air flow rate, solar energy power and aspect ratio of window were considered as main variables. From the result of the comparison between the exhaust airflow window and the enclosed window, the indoor heat gain was reduced remarkably by 76%. It is also suggested that in the design of the exhaust airflow window optimum values of aspect ratio, H/W and exhaust air flow rate, Re were about 0.05 and 600, respectively.

  • PDF

한국 전통주거의 기류 분석을 통한 자연통풍 설계 연구 (Natural Ventilation Planning by Analysis on Air Velocity Property of a Traditional Korean House)

  • 최윤정;김인선;허범팔
    • 한국실내디자인학회:학술대회논문집
    • /
    • 한국실내디자인학회 2001년도 춘계학술발표대회 논문집
    • /
    • pp.117-120
    • /
    • 2001
  • This study is a preliminary research to develop design principles for environmentally friendly housing. The purposes of study are to investigate the literatures related passive design for summer and theory of ventilation, to analyze the indoor airflow patterns in traditional Korean house during summer, and to propose the design factors for effective passive cooling system. The analysis for airflow patterns was focused on the ‘An bang’and the ‘Dae Chung’in the ‘An Chae’of a traditional house located in Seoul. Field measurements of air temperature and air velocity were carried out at 30 different measuring points with 8 different window-opening conditions. The measurements were taken on the hottest summer days in August 2000. It is concluded that from an environmentally friendly standpoint design factors to control indoor thermal environment by a passive cooling system during the summer are as follows; ceiling structure has thermal performance like a time-lag effect, optimum height and length of eaves which can prevent sunlight and divert airflow toward the sitting level, building arrangement acceptable the prevailing wind, strategic window arrangement which makes cross ventilation possible (especially north-south) at the sitting level, window opening condition which is possible to intersect two cross-ventilation stream at the main living areas, northward windows remaining in shade to create the air pressure difference, and planning building shape like a bracket that has optimum width and depth.

  • PDF

이중외피시스템을 적용한 고층 주거용건물의 자연환기 성능평가 (A Study on Natural Ventilation Performance for a Double-Skin Facade System in Apartment Buildings)

  • 석호태;김동화;최정민
    • 한국주거학회논문집
    • /
    • 제14권3호
    • /
    • pp.119-126
    • /
    • 2003
  • The purpose of this study is to evaluate the natural ventilation performance for variable external wind speed as a preliminary step to determining the seasonal operating modes of the Double-skin Facade System applied to apartment buildings. For this purpose, two simulation programs are used to compare the Double-Skin Facade System with the Double Sash Window. First, TAS is used to plan a schedule for natural ventilation during the intermediate season and to analyze the cooling loads. Second, CFD is used for a more detailed airflow analysis on a typical floor plan of the model building. The results of the simulations on natural ventilation performance show that the Double-Skin Facade System can reduce the cooling load by 10.5% compared to the Double Sash Window.

한지(韓紙)의 환기성능에 관한 실험적 연구 (The Experimental Study on the Efficiency of Ventilation of Korean Paper (Hanji))

  • 이종원;임정명
    • 설비공학논문집
    • /
    • 제16권5호
    • /
    • pp.482-489
    • /
    • 2004
  • The purpose of this study is to reevaluate the performance of Hanji as a architectural material. Recent studies report that one of the causes of the Sick-HouseㆍSick-Building Syndrome is due to the contaminants from interior materials and the lack of ventilation. In this study, the properties of Hanji are investigated. The major focuses of this research are (1) how efficient the Hanji is for ventilation of the house and (2) whether the usage of Hanji brings required ventilation volume to the house. According to the test results, differential pressure in the air and the amount of ventilation showed linear relationship. Test results differ from various kinds of Hanji. Since houses usually have double window system, Hanji can be used to the windows system, especially for inner part of double window system. It is suggested that the combination of Hanji windows for the inner part and glass windows for outer part is very effective, and offers a solution to improvement of indoor air quality and the lack of ventilation with passive ventilation that has less energy consumption.

역사적 건축물의 에너지 효율 향상을 위한 계획기법 -서양의 연구동향 및 사례를 중심으로- (Technical Measures for Improving Energy Efficiency in Historic Buildings -Focused on Researches and Case Studies of the West-)

  • 김태영
    • 한국농촌건축학회논문집
    • /
    • 제20권1호
    • /
    • pp.69-76
    • /
    • 2018
  • This study is to research technical measures for improving energy efficiency in the conservation and reuse of historic buildings focused on the recent research trends and case studies of the west. These measures are broadly classified into three types, the passive measures for saving energy and increasing comfort, the most cost-effective energy saving strategies, and the renewable energy sources. Firstly, the passive measures are divided into the elements and systems. The passive elements are awnings and overhanging eaves, porches, shutters, storm windows and doors, and shade trees. There are also the natural ventilation systems such as the historic transoms, roofs and attics to improve airflow and cross ventilation to either distribute, or exhaust heat. Secondly, the most cost-effective energy efficiency strategies are the interior insulation, airtightness and moisture protection, and the thermal quality improvement of windows. The energy efficiency solutions of modern buildings are the capillary-active interior insulation, the airtightness and moisture protection of interior walls and openings, and the integration of the original historic window into the triple glazing. Beyond the three actions, the additional strategies are the heat recovery ventilation, and the illumination system. Thirdly, there are photovoltaic(PV) and solar thermal energy, wind energy, hydropower, biomass, and geothermal energy in the renewable energy sources. These energy systems work effectively but it is vital to consider its visual effect on the external appearance of the building.

설비공학 분야의 최근 연구 동향 : 2016년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2016)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제29권6호
    • /
    • pp.327-340
    • /
    • 2017
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2016. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of flow, heat and mass transfer, the reduction of pollutant exhaust gas, cooling and heating, the renewable energy system and the flow around buildings. CFD schemes were used more for all research areas. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results of the long-term performance variation of the plate-type enthalpy exchange element made of paper, design optimization of an extruded-type cooling structure for reducing the weight of LED street lights, and hot plate welding of thermoplastic elastomer packing. In the area of pool boiling and condensing, the heat transfer characteristics of a finned-tube heat exchanger in a PCM (phase change material) thermal energy storage system, influence of flow boiling heat transfer on fouling phenomenon in nanofluids, and PCM at the simultaneous charging and discharging condition were studied. In the area of industrial heat exchangers, one-dimensional flow network model and porous-media model, and R245fa in a plate-shell heat exchanger were studied. (3) Various studies were published in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, subjects include mobile cold storage heat exchanger, compressor reliability, indirect refrigeration system with $CO_2$ as secondary fluid, heat pump for fuel-cell vehicle, heat recovery from hybrid drier and heat exchangers with two-port and flat tubes. In the alternative refrigeration/energy system category, subjects include membrane module for dehumidification refrigeration, desiccant-assisted low-temperature drying, regenerative evaporative cooler and ejector-assisted multi-stage evaporation. In the system control category, subjects include multi-refrigeration system control, emergency cooling of data center and variable-speed compressor control. (4) In building mechanical system research fields, fifteenth studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, renewable energies, etc. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which could be help for improving the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the analyses of indoor thermal environments controlled by portable cooler, the effects of outdoor wind pressure in airflow at high-rise buildings, window air tightness related to the filling piece shapes, stack effect in core type's office building and the development of a movable drawer-type light shelf with adjustable depth of the reflector. The subjects of building energy were worked on the energy consumption analysis in office building, the prediction of exit air temperature of horizontal geothermal heat exchanger, LS-SVM based modeling of hot water supply load for district heating system, the energy saving effect of ERV system using night purge control method and the effect of strengthened insulation level to the building heating and cooling load.