• Title/Summary/Keyword: airflow

Search Result 769, Processing Time 0.022 seconds

Off-design Characteristics for Ambient Air Temperature and Turbine Load of Gas Turbine Pre-swirl System (가스터빈 프리스월 시스템의 외기 온도와 터빈 부하 조건에 따른 탈설계점 특성 분석)

  • Park, Hyunwoo;Lee, Jungsoo;Cho, Geonhwan;Cho, Jinsoo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.47 no.12
    • /
    • pp.881-889
    • /
    • 2019
  • The pre-swirl system is the device that minimizes energy loss of turbine cooling airflow from the stationary parts into rotating parts. In this paper, an off-design analysis was conducted for the ambient air temperature and turbine load conditions. The discharge coefficient was constant for ambient air temperature and turbine load. However, adiabatic effectiveness was increased. This is due to the volume flow rate. The volume flow rate was increased at higher ambient temperature and higher turbine load. It means that the volume of cooling air was increased and the cooling performance of the air was improved. Consequently, adiabatic effectiveness increased by 30.46% at 100% turbine load compared to 20% turbine load. And increased by 18.42% at 55℃ ambient air temperature compared to -20℃ ambient air temperature.

Study on Influence of Air Flow of Ceiling Type Air Conditioner on Fire Detector Response (천장형에어컨 기류가 화재감지기 작동에 미치는 영향 분석)

  • Choi, Moon-Soo;Lee, Keun-Oh
    • Fire Science and Engineering
    • /
    • v.32 no.5
    • /
    • pp.40-45
    • /
    • 2018
  • This paper is an analysis of the influence of ceiling air conditioner airflow on fire detector response. In order to analyze the response characteristics of fire detector while forming air flow of a ceiling-type air conditioner, fire tests were carried out in accordance with ISO standard. This experiment was carried out in a fire test site of 10 m (width) ${\times}$ 7 m (length) ${\times}$ 4 m (height). As a result of the experiment, the response of fire detector shows a normal pattern that is delayed as the distance from the fire source is increased in the absence of the air conditioner, but it is confirmed that the pattern is not maintained in the strong air flow. When the air flow of air conditioner was strong, the response time was increased by 121% in the smoke detector and by 39% in the heat detector. In the case of ceiling type air conditioners, it is considered that the number of fire detectors should be increased, or a detector with high sensitivity should be installed for early detection of fire.

The Study of Air Sampling Smoke Detector (공기흡입형 연기감지장치에 관한 연구)

  • 이복영;이병곤
    • Fire Science and Engineering
    • /
    • v.17 no.4
    • /
    • pp.86-91
    • /
    • 2003
  • Since the air stream in the room controlled by HVAC system affects on he expected response of conventional detectors which are designed in accordance with normal characteristics of air stream in the fire incident, unexpected operation time delay may occur in fire. In order to solve this problem and to improve sensitivity so that to initiate fire in its early stages for minimizing damage and protecting people, we studied and developed Air Sampling Smoke Detector. The Air Sampling Smoke Detector is a kind of active-type fire detection system. it draws air continuously from the protected area through an air sampling pipe network to the smoke density analyzer. This study presents smoke density analysing technique and air intake balancing technique through an air sampling pipe network. As a result of evaluating, Air Sampling Smoke Detector was much more sensitive than conventional smoke detectors that passively wait for smoke to reach them and was not affected by ambient airflow in the room by means of balanced air intake through the sampling holes.

SURGICAL MANAGEMENT OF VELOPHARYNGEAL INCOMPETENCE USING SUPERIORLY BASED PHARYNGEAL FLAP (상부기저형 인두피판을 이용한 구개인두 부전증의 외과적 처치)

  • Ann, Jye-Jynn;Chang, Se-Hong;Park, Chi-Hee;Woo, Sung-Do
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.13 no.3
    • /
    • pp.338-345
    • /
    • 1991
  • Velopharyngeal incompetence (VPI) is a condition of inadequate functional valving between the oral and nasal cavities that results in hypernasal speech and nasal air escape. VPI is caused by the following factors ; cleft palate, soft palate defect, pharyngomegaly, velopharyngeal sphincter muscle anomaly and maxillary advancement surgery, etc. Velopharyngeal function is assessed by a variety of measures that include speech evaluation, cephalogram, airflow study, videofluoroscopy and nasoendoscopy. The management of VPI is classified into four main groups ; prosthesis, insertion of implant, palatoplasty and pharyngoplasty. Pharyngeal flap is the most common surgical procedure for correcting VPI since Schoenborn's report in 1875. We report seven cases of VPI which were treated by modified modified superiorly based pharyngeal flap with good results.

  • PDF

Measurement Uncertainty of Nicotine in Environmental Tobacco Smoke (ETS)

  • Lee, Jeong-Il;Lee, Cheol Min;Shim, In-Keun;Kim, Seong-Mi;Lee, Woo-Seok;Kim, Yoon-Shin
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.8
    • /
    • pp.2394-2398
    • /
    • 2013
  • Nicotine is the main component of environmental tobacco smoke, and its presence in indoor air is widely used as a secondhand-smoke indicator. Environmental tobacco smoke is a major source of indoor air pollution, but sufficient investigation of the uncertainty of its measurement, which mirrors the reliability of nicotine measurement, has not been performed. We calculated the uncertainty of measurement of indoor air nicotine concentration at low, medium, and high concentrations of 11.3798, 10.1977, $98.3768{\mu}g/m^3$, respectively, and we employed the Guide to the Expression of Uncertainty in Measurements (GUM), proposed by the International Organization for Standardization (ISO). The factors considered in determining the uncertainty were uncertainty of the calibration curve (calibration curve and repeated measurements), desorption efficiency, extraction volume, and sampling airflow (accuracy and acceptable limits of flowmeter). The measurement uncertainty was highest at low concentrations; the expanded measurement uncertainty is $0.9435{\mu}g/m^3$ and is represented as a relative uncertainty of 63.38%. At medium and high (concentrations, the relative uncertainty was 13.1% and 9.1%, respectively. The uncertainty of the calibration curve was largest for low indoor nicotine concentrations. To increase reliability of measurement in assessing the effect of secondhand smoke, measures such as increasing the sample injection rate ($1{\mu}L$ or more), increasing sampling volume to increase collected nicotine, and using gas chromatography-mass spectrometry (GC/MS) or GC/MS/MS, which has a lower quantitation threshold, rather than gas chromatography with nitrogen phosphorous detector, should be considered.

Electromyographic evidence for a gestural-overlap analysis of vowel devoicing in Korean

  • Jun, Sun-A;Beckman, M.;Niimi, Seiji;Tiede, Mark
    • Speech Sciences
    • /
    • v.1
    • /
    • pp.153-200
    • /
    • 1997
  • In languages such as Japanese, it is very common to observe that short peripheral vowel are completely voiceless when surrounded by voiceless consonants. This phenomenon has been known as Montreal French, Shanghai Chinese, Greek, and Korean. Traditionally this phenomenon has been described as a phonological rule that either categorically deletes the vowel or changes the [+voice] feature of the vowel to [-voice]. This analysis was supported by Sawashima (1971) and Hirose (1971)'s observation that there are two distinct EMG patterns for voiced and devoiced vowel in Japanese. Close examination of the phonetic evidence based on acoustic data, however, shows that these phonological characterizations are not tenable (Jun & Beckman 1993, 1994). In this paper, we examined the vowel devoicing phenomenon in Korean using data from ENG fiberscopic and acoustic recorders of 100 sentences produced by one Korean speaker. The results show that there is variability in the 'degree of devoicing' in both acoustic and EMG signals, and in the patterns of glottal closing and opening across different devoiced tokens. There seems to be no categorical difference between devoiced and voiced tokens, for either EMG activity events or glottal patterns. All of these observations support the notion that vowel devoicing in Korean can not be described as the result of the application of a phonological rule. Rather, devoicing seems to be a highly variable 'phonetic' process, a more or less subtle variation in the specification of such phonetic metrics as degree and timing of glottal opening, or of associated subglottal pressure or intra-oral airflow associated with concurrent tone and stricture specifications. Some of token-pair comparisons are amenable to an explanation in terms of gestural overlap and undershoot. However, the effect of gestural timing on vocal fold state seems to be a highly nonlinear function of the interaction among specifications for the relative timing of glottal adduction and abduction gestures, of the amplitudes of the overlapped gestures, of aerodynamic conditions created by concurrent oral tonal gestures, and so on. In summary, to understand devoicing, it will be necessary to examine its effect on phonetic representation of events in many parts of the vocal tracts, and at many stages of the speech chain between the motor intent and the acoustic signal that reaches the hearer's ear.

  • PDF

Changes in Aerodynamic Function and Closed Quotient with the Variable Pitch and Loudness in Male Classic Singers (남성 성악가의 음도고정시 강도 변화와 강도고정시 음도 변화의 공기역학 및 성대접촉율의 변화)

  • Nam, Do-Hyun;Paik, Jae-Yeon;Kim, Jae-Ok;Park, Sun-Young;Choi, Hong-Shik
    • Speech Sciences
    • /
    • v.14 no.2
    • /
    • pp.23-33
    • /
    • 2007
  • This study examined the aerodynamic functions (mean airflow rate MFR, subglottal pressure Psub) and closed quotients (CQs) in the fixed pitch (C3, E3, G3, C4) with the variable loudness (70 and 80 dB) as well as in the fixed loudness at 70 dB and 80 dB with the variable pitch (C3, E3, G3, C4) in five classic male singers (Baritone). Results showed that MFR significantly increased at C3, E3, and G3 and Psub significantly increased at C4 when the loudness increased from 70 to 80 dB. At 70 dB, MFR and Psub significantly increased and CQ significantly decreased when the pitch increased from C3 to C4. At 80 dB, MFR significantly decreased when the pitch increased from C3 to G3. However, Psub showed the significant decrease with the pitch increased at 80 dB. In conclusion, as the loudness increases, the aerodynamic loss is getting higher and vocal efficiency becomes lower at low pitch than at higher pitch. At a low loudness level, the main mechanism to control loudness is the amount of medial compression of the vocal folds rather than the aerodynamic function. In addition, the aerodynamic function and medial compression of the vocal folds have a significant role in increasing the loudness level.

  • PDF

Characteristics of Speech Breathing in de novo Idiopathic Parkinson's Disease during Passage Reading Tasks (De novo 특발성 파킨슨병 환자의 문단 읽기 과제에서의 호흡 특성)

  • Kim, Byung-Me;Sohn, Young-Ho;Baek, Seung-Jae;Lee, Phil-Hyu;Nam, Chung-Mo;Lee, Ji-Eun;Choi, Yae-Lin
    • Phonetics and Speech Sciences
    • /
    • v.3 no.1
    • /
    • pp.103-110
    • /
    • 2011
  • Idiopathic Parkinson's Disease patients' speech is hypokinetic dysarthria and their speech is possibly the consequence of impaired respiratory support. The purpose of this study was focused on the respiratory characteristics of speech breathing in de novo IPD who were not given prior vocal or anti-Parkinson treatment. A total of 40 subjects participated in the study: 20 de novo IPD patients between the ages of 50 and 80, and 20 normal subjects with similar age, height, and weight matches. Forced Expiratory Vital Capacity (FVC), Forced Expiratory Volume in 1 sec (FEV1) and $FEV_1$ as a percentage of FVC (FEV1/FVC) was measured with a PC-based spirometer (Cosmed). In addition, Maximum Phonation Time (MPT), Mean Airflow Rate (MFR), Subglottal Pressure (Psub) and the number of syllables produced per breath were measured with a Phonatory Aerodynamic System (Kay PENTAX). All subjects were asked to read a standardized Korean paragraph and the following measurements were obtained from the task. Results indicated no statistically significant differences in respiratory function (FEV1/FVC%) and aerodynamic function between the two groups, but the number of syllables per breath was significantly lower in the IPD patient group than in the normal group and it could be predicted by FVC and MFR. Therefore, the study shows that the MFR from the lungs during speech in de novo IPD patients is used inefficiently.

  • PDF

Multiple Small Nodular Lung Lesions with Severe Dyspnea (심한 호흡곤란을 보인 다발성 소결절성 폐질환)

  • Yang, Suck-Chul;Lee, Kyung-Sang;Yoon, Ho-Joo;Shin, Dong-Ho;Park, Sung-Soo;Lee, Jung-Hee;Hahm, Shee-Young;Lee, Chul-Burm
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.2
    • /
    • pp.285-290
    • /
    • 1996
  • Diffuse panbronchiolitis is a chronic inflammatory lung disease of unknown etiology which is characterized by chronic airflow limitation and airway inflammation, predominantly localized in the respiratory bronchioles with infiltration of inflammatory cells, and has typical clinical, radiological and pathological features. Obstructive respiratory functional impairment, occasional symptoms of wheezing, and also cough and sputum resemble the feature of emphysema, bronchial asthma, or chronic bronchitis, respectively. We experienced a case of pathologically proven advanced diffuse panbronchiolitis in a 55-year-old man with productive cough and exertional dyspnea. The chest radiography showed multiple tiny nodular densities on whole lung fields. It was confirmed by thoracoscopy-guided lung biopsy and the patient was improved after initiation of treatment with low-dose erythromycin.

  • PDF

Doubled Thrust by Boundary Layer Control in Scramjet Engines in Mach 4 and 6

  • Mitani, Tohru;Sakuranaka, Noboru;Tomioka, Sadatake;Kobayashi, Kan;Kanda, Takeshi
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.734-741
    • /
    • 2004
  • Boundary layer ingestion in airframe-integrated scramjet engines causes engine stall (“engine un start” hereafter) and restricts engine performance. To improve the unstart characteristics in engines, boundary layer bleed and a two-staged injection of fuel were examined in Mach 4 and Mach 6 engine tests. A boundary layer bleed system consisting of a porous plate, an air coolers, a metering orifice and an ON/OFF valve, was designed for each of the engines. First, a method to determine bleed rate requirements was developed. Porous plates were designed to suck air out of the Mach 4 engine at a rate of 200 g/s and out of the Mach 6 engine at a rate of 30 g/s. Air coolers were then optimized based on the bleed airflow rates. The exhaust air temperature could be cooled below 600 K in the porous plates and the compact air coolers. The Mach 4 engine tests showed that a small bleed rate of 3% doubled the engine operating range and thrust. With the assistance of two-staged fuel injection of H2, the engine operating range was extended to Ф0.95 and the maximum thrust was tripled to 2560 N. The Mach 6 tests showed that a bleed of 30 g/s (0.6% of captured air in the engine) extended the start limit from Ф0.48 to Ф1 to deliver a maximum thrust of 2460 N.

  • PDF