• Title/Summary/Keyword: airborne virus

Search Result 29, Processing Time 0.021 seconds

Aerodynamic Approaches for Estimation of Waste Disease Spread in Pig Farm through Airborne Contaminants (양돈장의 소모성질병 확산 분석을 위한 현장 모니터링 및 공기유동학적 분석)

  • Seo, Il-Hwan;Lee, In-Bok;Moon, Oun-Kyung;Kwon, Kyeong-Seok
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.56 no.1
    • /
    • pp.41-49
    • /
    • 2014
  • Pig chronic wasting disease, including porcine reproductive and respiratory syndrome (PRRS) and postweaning multisystemic wasting syndrome (PMWS), have made a continuous economic damage in pig farms. Airborne spread of livestock viruses are an important spread factor which is difficult to analyze due to invisible airflow and limitation of measurement. The objective of this study is to analyze airborne disease spread between buildings in the experimental pig farm by means of field experiment and computational fluid dynamics (CFD). The field experiments were conducted to capture airborne virus using air sampler and teflon filter along multi points in the experimental pig farm. The samples were tested in terms of virus detection resulting in positive reaction for PRRS and PCV-2 viruses, which can be a firm evidence of airborne virus spread. The CFD simulation model was developed by considering complex topography, wind conditions, building arrangement, and ventilation systems and was used to analyze airborne virus spread according to different wind conditions. The CFD computed result showed a possibility of airborne virus spread via livestock aerosol from infected pig house to neighboring pig houses according to wind directions. The CFD simulation technique is expected to provide significant data for estimating and making a counterplan against airborne disease spread.

Validation and Application of OpenFOAM for Prediction of Livestock Airborne Virus Spread (공기 중 축산질병 확산예측을 위한 오픈폼 도입 및 검증)

  • Roh, Hyun-Seok;Seo, Il-Hwan;Lee, In-Bok
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.56 no.1
    • /
    • pp.81-88
    • /
    • 2014
  • Accurate wind data is essential for predicting airborne spread of virus. OpenFOAM was used for computational fluid dynamics (CFD) simulation procedure which is under GNU GPL (General Public License). Using complex terrain, DEM (Digital Elevation Map) that was prepared from GIS information covering a research site is converted to a three dimensional surface mesh that is composed by quad and full hexahedral space meshes. Around this surface mesh, an extended computational domain volume was designed. Atmospheric flow boundary conditions were used at inlet and roughness height and was considered at terrain by using rough wall function. Two different wind conditions that was relatively stable during certain periods were compared in 3 different locations for validating the accuracy of the CFD computed solution. The result shows about 10 % of difference between the calculated result and measured data. This procedure can simulate a prediction of time-series data for airborne virus spread that can be used to make a web-based forecasting system of airborne virus spread.

A Inquiry of Tracer Gas for Analysis of Dispersion and Prediction of Infection Possibility according to Airborne Viral Contaminants (건축공간에서 공기 감염균 확산을 해석하기 위한 추적가스 고찰과 농도에 따른 감염 위험성 예측 연구)

  • Lim, Tae-Seob;Kang, Seung-Mo;Kim, Byung-Seon
    • Korean Institute of Interior Design Journal
    • /
    • v.18 no.3
    • /
    • pp.102-113
    • /
    • 2009
  • The SARS virus began to appear and spread in North America and Southeast Asia in the early 2000' s, infecting and harming many people. In the process of examining the causes for the virus, studies on the airborne SARS virus and the way it spread were carried out mainly in the medical field. In the field of architecture, studies were done on the diffusion of air pollutants in buildings using gases such as $CO_2$, $N_2O$, or $SF_6$, but research on virus diffusion was limited. There were also explanations of only the diffusion process without accurate information and discussion on virus characteristics. The aim of this study is to analyze the physical characteristics of airborne virus, consider the possibility of using coupled analysis model and tracer gas for analyzing virus diffusion in building space and, based on reports of how the infection spread in a hospital where SARS patients were discovered, analyze infection risk using tracer gas density and also diffusion patterns according to the location, shape, and volume of supply diffusers and exhaust grilles. This paper can provide standards and logical principles for evaluating various alternatives for making decisions on vertical or horizontal ward placement, air supply and exhaust installation and air volumes in medium or high story medical facilities.

Assessment of Instrument Efficiency in Detecting Airborne Virus (공기 중 바이러스 포집 장비의 효율성 평가)

  • Ha, Tae-Hwan;Lee, In-Bok;Kwon, Kyeong-Seok;Lee, Sung-Bok;Song, Sang-Hyeon;Bitog, Jessie. P.;Yoon, Soon-Seek
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.54 no.1
    • /
    • pp.63-72
    • /
    • 2012
  • In livestock industry, damage caused by the epidemic diseases such as Foot-and-Mouth Disease (FMD), Highly-Pathogenic-Avian-Influenza (HPAI) and Porcine-Reproductive-and-Respiratory-Syndrome (PRRS) was very serious. The financial loss incurred from FMD alone which occurred on Nov. 2011 in Korea was estimated at 3 billion won, 23 % of annual livestock industry production. The livestock industry in Korea has greater risk of disease infection because of high density production, etc. Investigating the spread of livestock diseases should consider both direct and indirect contact as well as other various factors including airborne. Airborne infection of livestock disease was first hypothesised in the early 1900s, however, field experimental studies are still limited. Furthermore, no protocol is available in detecting airborne viruses in the field. In this study, effective virus samplers were investigated by comparative analysis of the type of samplers used detect to airborne virus. Laboratory experiments were conducted to compare virus samplers such as Bio-sampler, Dust-sampler, Compact-Cascade-Impactor (CCI) and Microflow in detecting PRRSV. Samples were analyzed by Reverse-Transcription PCR to assess the efficiency of the instrument in detecting the airborne virus. First, samples were classified into five levels according to light intensity of gel images and then the classified results were normalized. In every case, Bio-sampler and Dust-sampler were comparable with each other and have shown to be more effective than CCI and Microflow samplers.

Detection of Airborne Respiratory Viruses in Residential Environments (주거환경 공기 중 호흡기 바이러스의 검출)

  • Park, Keun-Tae;Moon, Kyong-Whan;Kim, Hyung-Tae;Park, Chan-Jung;Jeong, Ho-Chul;Lim, Young-Hee
    • Journal of Environmental Health Sciences
    • /
    • v.37 no.4
    • /
    • pp.306-314
    • /
    • 2011
  • Objectives: Respiratory virus infections are the most common disease among all ages in all parts of the world and occur through airborne transmission. The purpose of this study was to detect and quantitate human respiratory viruses in residential environments. Methods: Air samples were collected from the residential space of apartments in the Seoul/Gyeonggi-do area. The samples were collected from indoor and outdoor air. Among respiratory viruses, influenza A virus, influenza B virus, parainfluenza virus, metapneumovirus, respiratory syncytial virus, and adenovirus were investigated by multiplex polymerase chain reaction. Among the virus-positive samples, we performed adenovirus quantification by real-time polymerase chain reaction. Results: Virus detection rates were 44.0%, 3.8%, 3.4%, and 17.3% in spring, summer, autumn, and winter, respectively. The virus detection rate was higher in winter and spring than in summer and autumn. Adenovirus was most commonly detected, followed by influenza A virus and parainfluenza virus. Virus distribution was not significantly different between indoor and outdoor environments. Conclusions: Although virus concentrations were not high in residential environments, residents in houses with detected viruses may have an increased risk of exposure to airborne respiratory viruses, especially in winter and spring.

Numerical Analysis of Airborne Infection Control Performance of Germicidal Systems in a Temporary Shelter (수치해석을 이용한 임시대피소 내 공기감염확산 저감장치의 성능 분석)

  • Park, Jeongyeon;Sung, Minki;Lee, Jaewook
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.21 no.1
    • /
    • pp.7-15
    • /
    • 2015
  • Purpose : When natural disaster occurs, the victims are evacuated to temporary shelters such as indoor gymnasiums or large space buildings until their homes are recovered. If someone in this temporary shelter is infected with an airborne infectious disease, it becomes easier for the disease to spread to the other people in the shelter than it would be under normal conditions. Therefore, temporary shelters need to provide not only water and food but also hygienic indoor conditions. Methods : In this study, the use of mechanical systems such as ultraviolet germicidal irradiation (UVGI) systems and air cleaners were simulated using numerical analysis to find out how these systems can control airborne infection in temporary shelters. An indoor gymnasium was selected as a temporary shelter for the numerical simulation model considering Korea's post-disaster response system. Influenza A virus was assumed as an airborne infectious disease and the diffusion of the virus was made by one person in the shelter. Results : The result of this study showed that the UVGI systems disinfected the virus more effectively than the air cleaners by creating a more stable airflow after the disinfection process. The air cleaners could remove the virus but since it created an unstable airflow in the temporary shelter, the virus was condensed to a certain area to show a higher virus concentration level than the source location. Implications : In the temporary shelter, it is necessary to use UVGI systems or air cleaners for hygienic indoor conditions.

Comparisons of Certification Standards for Mask and Review on Filtration Efficiency for Viruses (마스크의 인증기준 비교와 바이러스 여과효율에 대한 고찰)

  • Yoon, Chungsik;Go, Sulbee;Park, Jihoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.2
    • /
    • pp.109-123
    • /
    • 2020
  • Objectives: The aims of this study were to review the standards and key components of the standards for disposable masks in Korea, the US, EU, Japan, and China and to evaluate the appropriateness of disposable masks during a virus pandemic. Methods: We reviewed the standards in the above countries and compared their key elements for each standard. For the second purpose, systemic paper gathering using key words like 'mask', 'respirator' 'virus', and 'coronavirus' in the PubMed search engine was performed. Fifty-three papers were selected and reviewed in regard to the appropriateness of test protocols with sodium chloride(NaCl) particles for virus filtration and the effectiveness against viruses. Results: The standards for masks are largely divided into two categories: US standards and EU standards. In Korea, the Ministry of Employment and Labor adapted the EU standards for workers and the Health Masks adopted the Ministry of Employment and Labor standards by the Ministry of Food and Drug Safety. Regarding airborne viral infections, WHO emphasizes only droplet infection, while many studies have shown that small particles enter the air through coughing or sneezing, which increases the possibility of airborne infection. Compared to other particles, various factors such as airborne viability and the ability to replicate the virus in the body are further involved in the virus's airborne infection rate. Airborne infection is classified into absolute air infection, preferential air infection, and opportunistic air infection. The NaCl-certified N95 mask showed good filtration efficiency against viruses and NaCl particles were proved to be a surrogate material for viruses. From this, KF94 is also expected to be effective in blocking viruses. Conclusion: The N95 test method could be used as a surrogate test method for virus filtration. N95-class masks have been found to effectively block viral infections in the air. However, surgical or medical masks are only partially effective against airborne virus infection though they could effectively block large droplet infection. However, most studies considered in this study targeted N95 in foreign countries and studies on masks actually used in Korea are very limited, so studies on microorganisms and reuse on domestic masks should be conducted in the future.

Effects of Hantaan Virus and $IFN-{\gamma}$ on Induction of Surface ICAM-1 in Primary Cultured Human Nasal Epithelial Cells and Human Lung Fibroblasts

  • Park, Ho-Sun;Kim, Sung-Kwang
    • The Journal of Korean Society of Virology
    • /
    • v.28 no.4
    • /
    • pp.317-325
    • /
    • 1998
  • The primary culture of human nasal epithelial cells was performed using the inferior nasal turbinate tissues, and infected with Hantaan virus to examine the hypothesis of airborne transmission of Hantaan virus in humans. The primary culture cells were identified as epithelial cells by morphologic and immunologic analyses. The viral antigens were detected in the primary human nasal epithelial cells infected with Hantaan virus by immunofluorescence staining. The ICAM-1 induction by Hantaan virus or $IFN-{\gamma}$ was examined in the primary human nasal epithelial cells and human lung fibroblasts (WI-38). Hantaan virus induced the surface ICAM-1 in WI-38 cells in a time-dependent manner, and $IFN-{\gamma}$ induced the surface ICAM-1 in a dose-dependent manner in HNEC and WI-38 cells. These results revealed that the human nasal epithelial cells are susceptible to Hantaan viral infection supporting the hypothesis of airborne transmission of Hantaan virus in humans. The human lung fibroblasts also might have an important role in the pathogenesis of Hantaan virus through the induction of ICAM-1.

  • PDF

Airborne infection risk of respiratory infectious diseases and effectiveness of using filter-embeded mechanical ventilator and infectious source reduction device such as air cleaner (실내 공간에서의 호흡기 감염병 공기전파감염 위험도와 공기정화장치(필터 임배디드 기계식 환기설비 및 공기청정기 등 실내 감염원 저감 장치) 사용에 따른 효율)

  • Park, Sungjae;Park, Geunyoung;Park, Dae Hoon;Koo, Hyunbon;Hwang, Jungho
    • Particle and aerosol research
    • /
    • v.16 no.4
    • /
    • pp.73-94
    • /
    • 2020
  • Particulate infectious sources, including infectious viruses, can float in the air, causing airborne infections. To prevent indoor airborne infection, dilution control by ventilation and indoor air cleaners are frequently used. In this study, the risk of airborne infection by the operation of these two techniques was evaluated. In case of dilution control by ventilation, a high efficiency air filter was embedded at the inlet of supply air. In this study, infectious source reduction devices such as indoor air cleaner include all kinds of mechanical-filters, UV-photo catalysts and air ionizers through which air flow is forced by fans. Two mathematical models for influenza virus were applied in an infant care room where infants and young children are active, and the risk reduction efficiency was compared. As a result, in the case of individually operating the ventilator or the infectious source reduction device, the airborne infection risk reduction efficiencies were 55.2~61.2% and 53.8~59.9%, respectively. When both facilities were operated, it was found that the risk of airborne infection was reduced about 72.2~76.8%. Therefore, simultaneous operation of ventilation equipment and infectious source reduction device is the most effective method for safe environment that minimizes the risk of airborne infection of respiratory infectious diseases. In the case of a space where sufficient ventilation operation is difficult, it was found that the operation of an infectious source reduction device is important to prevent the spread of infectious diseases. This study is meaningful in that it provides an academic basis for strategies for preventing airborne infection of respiratory infectious diseases.

A Study on CFD analysis of indoor airborne microbe transport in car for microbiological safety (미생물 안전을 위한 승용차 실내 부유 미생물 거동에 관한 CFD 연구)

  • Choi, Sang-Gon
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.4
    • /
    • pp.225-232
    • /
    • 2013
  • Recently SARS and bird flu has been infected widely in the world; we have to care about germs and virus in indoor air environment. Especially that transmission by means of transportation is a major infection route. In this study, a private car simulated with CFD for prediction of indoor airborne microbe transport. Simulation performed with real situation in car, four occupants with a infected driver and four stage air ventilation controled by HVAC system. Result show that CFD can be visualized microbe transport other occupants and who is more exposed to airborne microbe. also it make a prediction of microbe transport in car.