• Title/Summary/Keyword: airborne based

Search Result 446, Processing Time 0.025 seconds

Effect of surface treatment and luting agent type on shear bond strength of titanium to ceramic materials

  • Karaokutan, Isil;Ozel, Gulsum Sayin
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.2
    • /
    • pp.78-87
    • /
    • 2022
  • PURPOSE. This study aimed to compare the effect of different surface treatments and luting agent types on the shear bond strength of two ceramics to commercially pure titanium (Cp Ti). MATERIALS AND METHODS. A total of 160 Cp Ti specimens were divided into 4 subgroups (n = 40) according to surface treatments received (control, 50 ㎛ airborne-particle abrasion, 110 ㎛ airborne-particle abrasion, and tribochemical coating). The cementation surfaces of titanium and all-ceramic specimens were treated with a universal primer. Two cubic all-ceramic discs (lithium disilicate ceramic (LDC) and zirconia-reinforced lithium silicate ceramic (ZLC)) were cemented to titanium using two types of resin-based luting agents: self-cure and dual-cure (n = 10). After cementation, all specimens were subjected to 5000 cycles of thermal aging. A shear bond strength (SBS) test was conducted, and the failure mode was determined using a scanning electron microscope. Data were analyzed using three-way ANOVA, and the Tukey-HSD test was used for post hoc comparisons (P < .05). RESULTS. Significant differences were found among the groups based on surface treatment, resin-based luting agent, and ceramic type (P < .05). Among the surface treatments, 50 ㎛ air-abrasion showed the highest SBS, while the control group showed the lowest. SBS was higher for dual-cure resin-based luting agent than self-cure luting agent. ZLC showed better SBS values than LDC. CONCLUSION. The cementation of ZLC with dual-cure resin-based luting agent showed better bonding effectiveness to commercially pure titanium treated with 50 ㎛ airborne-particle abrasion.

Evaluation of Impactor's Collection Efficiency on Airborne Bacteria by Type of Agar Media and Storage Condition (배지 종류 및 저장 조건에 따른 impactor의 부유세균 시료 채취 효율 평가)

  • Kim, Ki-Youn;Jang, Gyu-Yeob;Park, Jae-Beom;Kim, Chi-Nyon;Lee, Kyung-Jong
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.2 s.95
    • /
    • pp.145-149
    • /
    • 2007
  • The range of reduction rates of airborne bacteria concentration at 6 hrs, 12 hrs, 24 hrs and 48 hrs, which means a storage time until input of agar media into incubator after air sampling with an impactor. were 15-20%, 25-40%, 35-50% and 55-70%, respectively, compared to initial concentration. Types of agar media and storage thermal condition did not significantly affect a collection efficiency of impactor in terms of evaluating airborne bacteria level (p>0.05). To better improve the impactor's collection efficiency of airborne bacteria, based on the result of this study, it is recommended that the vicinity of $25^{\circ}C$ should be sustained until input of agar media into incubator after air sampling.

A Helicopter-borne Pulse Doppler Radar Signal Processor Development using High Speed Multi-DSP (고속 Multi-DSP를 이용한 헬기탑재 펄스 도플러 레이다 신호처리기 개발)

  • Kwag, Young-Kil;Choi, Min-Su;Jeun, In-Pyung;Hwang, Gwang-Yeon;Lee, Kang-Hoon;Lee, Jae-Ho
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2005.11a
    • /
    • pp.23-28
    • /
    • 2005
  • An airborne radar is an essential aviation electronic system of the helicopter to perform various missions in all-weather environments. This paper presents the results of the design and implementation of the airborne pulse doppler radar signal processor using high multi-DSP for the multi-function radar capability such as short-range, midium-range, and long-range depending on the mission of the vehicle. Particularly, the radar signal processor is developed using two DSP boards in parallel for the various radar signal processing algorithm. The key algorithms include LFM chirp waveform-based pulse compression, MTI clutter filter, MTD processor, adaptive CFAR, and clutter map. Especially airborne moving clutter Doppler spectrum compensation algorithm such as TACCAR is implemented for the multi-mode airborne radar system. The test results shows the good Doppler spectral separation for the clutter and the moving target in the flight test environment using helicopter.

  • PDF

Effects of Airborne Samples Collected in Yeochun on Gap Junctional Inter cellular Communication in WBF-344 Rat Liver Epithelial Cells (여천공단 일부지역의 대기오염물질이 WBF-344간 상피세포의 Gap Junctional Intercellular Communication에 미치는 영향)

  • 양재만;박재학;김윤신;이영순
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.13 no.3
    • /
    • pp.207-214
    • /
    • 1997
  • We collected airborne complex mixtures in a industrial area of Yeochun, and examined whether these complex mixtures could affect gap junctional intercellular communication (GJIC) in a cultured WBF-344 rat liver epithelial cells (LEC). Since the reduction of GJIC plays an important role in chemical carcinogenesis, measurement of changes of GJIC is a meaningful method to screen carcinogenicity of these mixtures. High and low volume samples were dissolved in dimethyl sulfoxide (DMSO) and tested. Blank filter extractions were also examined for exclud-ing possible toxicity of filter itself, and TPA (12-O-tetradecanoylphorbol-13-acetate) and DMSO were used as positive and negative control, respectively. When the cells were exposed to samples at concentration below that required to maintain rather than 85% cell viability based on the result of neutral red uptake assay, maximal inhibition of GJIC was observed at 1hr after treatment with both high and low volume samples by scrape-loading dye transfer assay. In fluorescence recovery after photobleaching assay, recovery rates via gap junctions were 33%/min in high volume sample and 62%/min in low volume sample. In together, airborne samples collected in Yeochun inhibited GJIC in a cultured WBF-344 rat LEC. These results suggest airborne samples tested in this experiment may attribute to cause a certain type and degree of cancers in in vivo when exposured for some periods.

  • PDF

Validation and Application of OpenFOAM for Prediction of Livestock Airborne Virus Spread (공기 중 축산질병 확산예측을 위한 오픈폼 도입 및 검증)

  • Roh, Hyun-Seok;Seo, Il-Hwan;Lee, In-Bok
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.56 no.1
    • /
    • pp.81-88
    • /
    • 2014
  • Accurate wind data is essential for predicting airborne spread of virus. OpenFOAM was used for computational fluid dynamics (CFD) simulation procedure which is under GNU GPL (General Public License). Using complex terrain, DEM (Digital Elevation Map) that was prepared from GIS information covering a research site is converted to a three dimensional surface mesh that is composed by quad and full hexahedral space meshes. Around this surface mesh, an extended computational domain volume was designed. Atmospheric flow boundary conditions were used at inlet and roughness height and was considered at terrain by using rough wall function. Two different wind conditions that was relatively stable during certain periods were compared in 3 different locations for validating the accuracy of the CFD computed solution. The result shows about 10 % of difference between the calculated result and measured data. This procedure can simulate a prediction of time-series data for airborne virus spread that can be used to make a web-based forecasting system of airborne virus spread.

Ground-Platform Sensor Position Optimization Based Hybrid Time Difference of Arrival Method for Airborne Emitter (Hybrid TDOA 알고리즘 기반의 Airborne Emitter 위치탐지를 위한 Ground-Platform 센서의 위치 최적화)

  • Park, Jin-Oh;Lee, Woo-Seok;You, Byung-Sek;Kook, Chan-Ho;Chung, Jae-Woo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.886-893
    • /
    • 2010
  • This paper considers the problem of time difference-of-arrival(TDOA) source localization when the TDOA and angle of arrival(AOA) measurements from an airborne emitter source are subject to ground-platform sensor position. The optimization of sensors' position is a challenging problem and a solution with good localization accuracy has yet to be found. This paper proposes an estimator that can achieve these purposes and provides optimized sensor position for good localization accuracy using the proposed estimator. The developed algorithm and sensor position are then examined under the special case of a single airborne source. The theoretical developments are supported by simulations.

Field Measurement of Airborne Sound Insulation for Noise Reduction about Community Facilities in an Apartment Complex (공동주택 단지 내 주민공동시설의 소음 방지를 위한 공기전달음 차단 성능 현장 조사)

  • Seong, Yo-Han;Kim, Jin-Sik;Kim, Hye-Won;Cho, Seong-Jun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.249-250
    • /
    • 2023
  • The objective of this study is to evaluate the airborne sound insulation performance between housing units and community facilities during the construction phase. Community facilities adjacent to housing units can lead to noise problems, hence it is necessary to minimize noise transmission during the design phase. However, flanking noise transmitted through gaps of structures, windows, pipes, and other openings may result in substandard sound insulation performance falling below the design standards. Therefore, It is crucial to measure airborne sound insulation in the field during the construction phase. The measurement was conducted using the survey method for the field measurement of the airborne sound insulation in accordance with KS F ISO 10052:2021. Although the noise standards caused by community facilities in apartment complexes are not specified in current laws and regulations, desired noise level was set based on international guidelines for indoor noise. First, the level of noise generated in community facilities was estimated, and then the sound insulation performance was evaluated to determine whether the desired noise level was achieved.

  • PDF

A Novel Timing Control Method for Airborne SAR Motion Compensation (항공기 요동보상을 위한 SAR시스템의 타이밍 제어 기법)

  • Lee, Hyon-Ik
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.453-460
    • /
    • 2010
  • For high quality image acquisition, compensating air-vehicle motion is essential for airborne SAR system. This paper describes a timing control based motion compensation method for airborne SAR system. Efficient timing control is critical for SAR system since it maintains many timing signals and timing setting for the signals should be updated frequently. This paper proposes Timing Cluster method as an efficient means for timing control of SAR system. Moreover, this paper suggests a simple and efficient method to compensate air-vehicle motion based on the Timing Cluster method. Timing Cluster method enables SAR system to control the timing in a timing noncritical way just maintaining little amount of information.

Estimation of Factors Influencing Airborne Fiber Concentrations through an Observation Survey of Asbestos-containing Materials in Buildings (석면함유 건축물의 관찰조사를 통한 실내공기 중 섬유 농도 변화 요인 추정)

  • Lee, Seungchul;Kim, Boowook;Yi, Gwang Yong;Shin, Yong Chul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.2
    • /
    • pp.174-183
    • /
    • 2015
  • Objectives: The objective of this study is the estimation of factors influencing airborne fiber concentrations by means of an observation survey of asbestos-containing materials in buildings. Methods: Forty-five samples were collected from four commercial buildings by NIOSH Method 7400 and classified according to current condition, potential activity, construction year, and operations and maintenance(O&M). Results: Airborne fiber concentrations by current condition(classified as good, fair and poor) were significantly different(p<0.05). Concentrations by potential activity were significantly different among groups(p<0.05), and those from the low activity group were higher than those from the middle activity group. Based on construction year, airborne fiber concentrations from the decade of the 1990's were higher than those from the 1960's. When O&M status was considered, airborne fiber concentrations from 1960's buildings were lower than those buildings not operated and maintained(p<0.01), because dust generation was influenced by O&M status. It was found that airborne fiber concentrations were related to current condition and potential activity via regression analysis, but the coefficient of determination was low. Also, correlation analysis showed that the higher the potential activity, the more current condition is worsened, but the relationship was not significant(r=-0.455, p>0.05). Conclusions: Airborne fiber concentrations in asbestos-containing buildings had weak relationships with current condition and potential activity.

Characteristics of Bioaerosol Generation of Household Humidifiers by User Practices (가정용 가습기의 사용자 습관에 따른 실내공기 중 바이오에어로졸의 발생특성)

  • Kim, Ik-Hyeon;Kim, Ki Youn;Kim, Daekeun
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.6
    • /
    • pp.503-509
    • /
    • 2012
  • Objectives: This study was performed in order to evaluate the generation characteristics of airborne bacteria and fungi while operating a household humidifier, in consideration of user habits. Methods: Microbial samples were collected in a closed chamber with a total volume of 2.76 $m^3$, in which a humidifier was operated according to experimental strategies. A cultivation method based on the viable counts of mesophilic heterotrophic bacteria and fungi was performed. Experimental strategies were divided into three classes: the type of water in the water reservoir (tap water, cooled boiled water); the frequency of filling the reservoir (refill every day, no refill); and the sterilization method (sterilization function mode, humidifier disinfectants). Results: Significant increases in the concentration of airborne bacteria were observed while the humidifier was in operation. The concentration had increased to 2,407 $CFU/m^3$ by 120 hours when tap water filled the reservoir without any application of sterilization, while for cooled boiled water, it was merely 393 $CFU/m^3$ at a similar time point. Usages of disinfectant in the water tank were more effective in decreasing bioaerosol generation compared to sterilization function mode operation. Generation characteristics of airborne fungi were similar to those of bacteria, but the levels were not significant in all experiments. Calculated exposure factor can be used as an indicator to compare biorisk exposure. Conclusion: This study identified the potential for bioaerosol generation in indoor environments while operating a household humidifier. User practices were critical in the generation of bioaerosol, or more specifically, airborne bacteria. Proper usage of a humidifier ensures that any biorisks resulting from generated bioaerosol can be prevented.