• 제목/요약/키워드: air-ground

검색결과 1,407건 처리시간 0.027초

지열원 시스템 히트펌프의 냉방 성능 특성에 관한 실증 연구 (Verification experiment of a ground source multi-heat pump at cooling mode)

  • 임효재;강신형;최재호;최종민;문제명;권영석;권형진;김록희
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.21-26
    • /
    • 2008
  • Recently, small and medium-sized buildings have employed a multi-heat pump. The major benefits of the multi-heat pump over a conventional system are that it is easier system to maintain along with a diversification of facility use, and high comfortability. The performance of multi-heat pump systems can be enhanced by using geothermal energy instead of air source energy. This paper describes the multi-heat pumps applied in an ground source heat pump system for an actual building. The performance of a ground source multi-heat pump installed in the field was investigated in cooling mode. The maximum COP of the systems with single U-tube and double tube ground loop heat exchangers were 6.6 and 6.0, respectively. It is suggested that the new algorithms to control the flow rate of secondary fluid for ground loop heat exchanger have to be developed in order to enhance the performance of the system.

  • PDF

Air sparging에 의한 지하수 순환에 관한 연구 (Investigation into circulation of ground water by air sparging)

  • 이준희;강구영
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 1998년도 공동 심포지엄 및 추계학술발표회
    • /
    • pp.232-235
    • /
    • 1998
  • Air sparging system is a kind of in-situ bioremediation method in the contaminated ground water. When Air sparging, the both of water circulation and oxygen transfer happend in the same time. The hydraulic differential head is zero at the middle height of well, is negative below the height and is possitive above the height. Hydroraulic head gradient is proportioned to air superficial velocity in the well. But over 24m/min of the superficial velocity, the hydraulic head gradient increase little.

  • PDF

식물공장 이중창호의 하절기 열전달 성능 분석 (Performance Analysis of Summertime Heat Transfer Characteristics of the Double Skin Window for Plant Factory)

  • 소재현;김우태
    • 설비공학논문집
    • /
    • 제24권4호
    • /
    • pp.351-357
    • /
    • 2012
  • To reduce the summertime cooling load of a plant factory, a concept design was performed for the double skin window which utilizes the low temperature air from a ground coupled heat exchanger. The design parameters were selected as the number of cavity air inlet, the cavity thickness, the location of cavity air inlet, and the configuration of cavity air outlet. A parametric study was conducted in a systematic way to evaluate the heat transfer characteristics of the double skin window. As the number of cavity air inlet and the cavity thickness increase, the heat flux from outside air to indoor air was decreased. The effect of the location of cavity air inlet was not significant and the larger cavity air outlet area gave us relatively better heat blocking performance from outside hot air. This study demonstrated that it is possible to develop an improved double skin window by utilizing a ground coupled heat exchanger.

시뮬레이션을 통한 지열 히트펌프 시스템과 VRF 시스템의 에너지 성능비교 (Comparison of Energy Performance between Ground-Source Heat Pump System and Variable Refrigerant Flow(VRF) Systems using Simulation)

  • 손병후;임효재;강성재
    • 한국지열·수열에너지학회논문집
    • /
    • 제17권3호
    • /
    • pp.30-40
    • /
    • 2021
  • This paper compares the annual energy performance of four different types of air-conditioning systems in a medium-sized office building. Chiller and boiler, air-cooled VRF, ground-source VRF, and ground-source heat pump systems were selected as the systems to be compared. Specifically, the energy performance of the GSHP system and the ground-source VRF system were compared with each other and also with conventional HVAC systems including the chiller and boiler system and air-cooled VRF system. In order to evaluate and compare the energy performances of four systems for the office building, EnergyPlus, a whole-building energy simulation program, was used. The EnergyPlus simulation results show that both the GSHP and the ground-source VRF systems not only save more energy than the other two systems but also significantly reduce the electric peak demand. These make the GSHP and the VRF systems more desirable energy-efficient HVAC technologies for the utility companies and their clients. It is necessary to analyze the impact of partial load performance of ground-source heat pump and ground-source VRF on the long-term (more than 20 years) performance of ground heat exchangers and entire systems.

수평형 지열 히트펌프 시스템의 냉난방 성능 분석 (Performance Analysis of Ground-Coupled Heat Pump System with Slinky-Type Horizontal Ground Heat Exchanger)

  • 손병후
    • 설비공학논문집
    • /
    • 제24권3호
    • /
    • pp.230-239
    • /
    • 2012
  • Ground-coupled heat pump (GCHP) systems utilize the immense renewable storage capacity of the ground as a heat source or sink to provide space heating, cooling, and domestic hot water. The main objective of the present study is to investigate the cooling and heating performance of a small scale GCHP system with horizontal ground heat exchanger (HGHE). In order to evaluate the performance, a water-to-air ground-source heat pump unit connected to a test room with a net floor area of 18.4 m2 and a volume of 64.4 m3 in the Korea Institute of Construction Technology ($37^{\circ}39'N$, $126^{\circ}48'E$) was designed and constructed. This GCHP system mainly consisted of slinky-type HGHE with a total length of 400 m, indoor heat pump, and measuring devices. The peak cooling and heating loads of the test room were 5.07 kW and 4.12 kW, respectively. The experimental results were obtained from March 15, 2011 to August 31, 2011 and the performance coefficients of the system were determined from the measured data. The overall seasonal performance factor (SPF) for cooling was 3.31 while the system delivered heating at a daily average performance coefficients of 2.82.

Helmet Mounted Display 장비를 사용한 공대지 표적의 위치정보 획득 (Location Information Extraction of An Air-to-Ground Target using Helmet Mounted Display Device)

  • 방극열;하석운
    • 한국컴퓨터정보학회논문지
    • /
    • 제16권3호
    • /
    • pp.1-7
    • /
    • 2011
  • 무장 전투기와 같은 공격용 항공기는 정밀한 공대공 또는 공대지 공격을 위해 표적의 정확한 위치 정보를 필요로 한다. 본 논문에서는 레이더나 FLIR과 같은 표적추적센서 없이 공대공 유도탄의 seeker head를 조종사의 머리가 가리키는 방향으로 유도하는 장비인 HMD만을 사용하여 공대지 표적의 위치정보를 획득하는 방법을 제시한다. 시뮬레이션 실험을 행한 결과 HMD를 수동 센서로 사용할 경우 다른 표적추적센서와의 연동 없이 HMD 만으로도 높은 정밀도의 표적 위치 정보를 획득할 수 있음을 발견하였다.

외기 온도 제어 방식을 적용한 지열 히트펌프 시스템의 냉방 성능 분석 (Cooling Performance Analysis of Ground-Source Heat Pump System with Capacity Control with Outdoor Air Temperature)

  • 손병후
    • 한국지열·수열에너지학회논문집
    • /
    • 제17권4호
    • /
    • pp.68-78
    • /
    • 2021
  • In order to solve the increasing deterioration of the energy shortage problem, ground-source heat pump (GSHP) systems have been widely installed. The control method is a significant component for maintaining the long-term performance and for reducing operation cost of GSHP systems. This paper presents the measurement and analysis results of the cooling performance of a GSHP system using capacity control with outdoor air temperature. For this, we installed monitoring equipments including sensors for measuring temperature, flow rate and power consumption, and then monitored operation parameters from July 9, 2021 to October 2, 2021. From measurement results, we analyze the effect of capacity control with outdoor air temperature on the cooling performance of the system. The average performace factor (PF) of the heat pump was 6.95, while the whole system was 5.54 over the measurement period. Because there was no performance data of the existing GSHP system, it was not possible to directly compare the existing control method and the outdoor air temperature method. However, it is expected that the performance of the entire system will be improved by adjusting the temperature of cold water produced by the heat pump, that is, the temperature of cold water on the load side according to the outside air temperature.

천연염색 직물의 환경조건에 따른 변.퇴색 및 물성변화에 관한 연구 (Effect of Storage Conditions on the Color and the Mechanical Properties of Fabrics dyed with Natural Dyes)

  • 이미식;홍문경;김의경;배순화
    • 한국의류학회지
    • /
    • 제25권3호
    • /
    • pp.617-628
    • /
    • 2001
  • Cotton and silk fabrics dyed with brazilein(Caesalpinia Sappan), berberine (Phellodendron Amurense), and shikonin(Lithospermum Erythrorhizon) were stored in the air, in the water, and under the ground for about one year. The change of the color, the flexibility, and the breaking strength were measured at the intervals of few weeks. The results are as follows; 1. The color of the fabrics changed most extensively in the fabrics that were under the ground, then in the order of the ones that were in the water, and in the air. The color of the fabrics changed to the achromatic color over the time. 2. The flexibility change among the dyes was similar. All the fabrics became stiff under the ground and in the water over the storage time. 3. In general, cotton and silk fabrics dyed with berberine showed better strength retention than the fabrics dyed with other substances. 4. The strength retention of cotton fabrics was high in the order of the fabrics which were in the air, in the water, and under the ground. Only minuscule change occurred in the strength of the cotton fabrics. The strength of the fabrics that were in the water and under the ground decreased remarkably after 30 weeks and 20 weeks respectively. 5. The strength retention of silk fabrics was high in the order of the fabrics which were in the air, under the ground, and in the water. In the air, the strength on silk fabrics decreased rapidly after 30 weeks. In the water, the strength of silk fabrics decreased more rapidly than that of the cotton fabrics. Under the ground, the strength retention of silk was higher than that of cotton.

  • PDF

장거리 공중-지상 영상정보용 데이터링크의 수신 안테나 최적 고각 제어 방법 (Optimum Elevation Angle Control of the Receiving Antenna for the Long Distance Air-Ground Common Data Link)

  • 류영재;안재민
    • 한국통신학회논문지
    • /
    • 제41권11호
    • /
    • pp.1528-1538
    • /
    • 2016
  • 영상정보용 데이터링크는 장거리의 공중-지상 환경에서 영상과 신호정보를 전송하도록 설계된 통신 시스템이다. 본 논문은 장거리 공중-지상 채널환경의 신호 분석에 적합한 곡면지구 2-Ray 모델을 사용하여 영상정보용 데이터 링크의 통신거리에 따른 수신전력 변화 폭을 분석하고 지면 반사파에 의한 수신전력의 변화폭을 경감할 수 있는 수신 안테나의 최적 고각 제어방법을 제안한다. 제안된 방법은 추가적인 하드웨어 성능 향상 없이도 기존의 고각 제어 방법에 비하여 추가적인 링크마진을 확보할 수 있다.

공압부양 고속 지상운송채의 비정상 공력해석 (Unsteady Aerodynamic Analysis of an Air-Pressure-Levitated High-Speed Ground Vehicle)

  • 조정현;조진수
    • 한국항공우주학회지
    • /
    • 제36권8호
    • /
    • pp.728-733
    • /
    • 2008
  • 경계요소법을 이용하여 비평면 지면 위를 움직이는 공압부양 고속 지상운송체의 비정상 공력해석을 수행하였다. 비정상 공력해석을 위하여 시간전진법과 이에 연계한 자유후류를 도입하였다. 공압부양 고속 지상운송체가 채널 내를 움직일 때, 채널에 갇힌 공기에 의해 지면효과가 증가하여 운송체의 양력계수와 피칭모멘트 계수가 더욱 증가한다. 즉, 채널과 같은 비평면 지면은 운송체의 종방향 불안정성을 증가시킨다. 반면, 채널과 같은 비평면 지면에 의한 양력상승이 운송체 탠덤날개의 왼쪽과 오른쪽에 동일하게 발생하기 때문에 채널과 같은 비평면 지면효과가 운송체의 횡방향 안정성에 미치는 영향은 크지 않다.