• 제목/요약/키워드: air-ground

검색결과 1,411건 처리시간 0.027초

지중열교환기의 종류에 따른 열전달 성능에 관한 연구 (A study on the Heat Transfer Performance according to Ground Heat Exchanger Types)

  • 황석호;송두삼
    • KIEAE Journal
    • /
    • 제10권4호
    • /
    • pp.75-80
    • /
    • 2010
  • Generally, ground-source heat pump (GSHP) systems have a higher performance than conventional air-source systems. However, the major fault of GSHP systems is their expensive boring costs. Therefore, it is important issue that to reduce initial cost and ensure stability of system through accurate prediction of the heat extraction and injection rates of the ground heat exchanger. Conventional analysis methods employed by line source theory are used to predict heat transfer rate between ground heat exchanger and soil. Shape of ground heat exchanger was simplified by equivalent diameter model, but these methods do not accurately reflect the heat transfer characteristics according to the heat exchanger geometry. In this study, a numerical model that combines a user subroutine module that calculates circulation water conditions in the ground heat exchanger and FEFLOW program which can simulate heat/moisture transfer in the soil, is developed. Heat transfer performance was evaluated for 3 different types ground heat exchanger(U-tube, Double U-tube, Coaxial).

지상운영시험을 통한 ADS-B 효과에 관한 연구 (A Study on Benefits of Ground Operational Test using ADS-B in Tae-An Airport)

  • 홍교영;오경륜;김도현
    • 한국항공운항학회지
    • /
    • 제15권2호
    • /
    • pp.25-31
    • /
    • 2007
  • The ADS-B test is a program that is examining the use of ADS-B, especially CDTI for aircraft surveillance in Korea. The ADS-B project is to provide operational benefits to Air Traffic Controllers in the selected area and provide first operational experience of ADS-B in ATCS environment of South Korea. For these objectives, the ground station has installed in Tae-An airport, Participation in the Ground Test has been limited to 4 Aircraft of Hanseo University which are installed ADS-B equipment. Ground test is a test that is examining on the movement area of Tae-An Airport on the assumption that the visibility is below weather minia of the airport. This test have been experimented as pre-arranged scenarios. In view of the results achieved, it has shown that the volume of voice communication between controller and pilot are remarkably reduced. Additionally, as both pilots and air traffic controllers are able to see the positions of traffic in the vicinity of the aircraft, the test has demonstrated that it is possible for ADS-B not only to decline the controller's workload, but also to enhance pilot situational awareness in the near future.

  • PDF

단일 탐침법을 이용한 수평형 지중열교환기 뒤채움재의 열확산계수 산정 (Thermal Diffusivity Evaluation of Backfilling Materials for Horizontal Ground Heat Exchanger Using Single-Probe Method)

  • 손병후;최항석
    • 설비공학논문집
    • /
    • 제23권5호
    • /
    • pp.356-364
    • /
    • 2011
  • Storage and transfer heat in soils is governed by the soil thermal properties and these properties are therefore needed in many engineering applications, including horizontal ground heat exchanger for ground-coupled heat pumps. This paper presents the evaluation results of the thermal diffusivity of soils (silica, quartzite, limestone, sandstone, granite, and two masonry soils used for the trench backfilling materials of the horizontal ground heat exchanger. To assess this thermal property, we (i) measure the soil thermal conductivities using single-probe method and (ii) use the de Vries method of summing the heat capacities of the soil constituents. The results show that the thermal diffusivity tends to increase as dry soil begins to wet, but it approaches a constant value or even decreases as the soil continues to wet. Combined algorithm with and improved model for the thermal conductivity of soils and the constituent equation provides accurate estimates of the soil thermal diffusivity.

단순 선형열원 모델을 이용한 지중 유효 열전도도와 보어홀 유효 열저항 산정 (Evaluation of Ground Effective Thermal Conductivity and Borehole Effective Thermal Resistance from Simple Line-Source Model)

  • 손병후
    • 설비공학논문집
    • /
    • 제19권7호
    • /
    • pp.512-520
    • /
    • 2007
  • The design of a ground-source heat pump system includes specifications for a ground loop heat exchanger where the heat transfer rate depends on the effective thermal conductivity of the ground and the effective thermal resistance of the borehole. To evaluate these heat transfer properties, in-situ thermal response tests on four vertical test boreholes with different grouting materials were conducted by adding a monitored amount of heat to circulating water. The line-source method is applied to the temperature rise in an in-situ test and extended to also give an estimate of borehole effective thermal resistance. The effect of increasing thermal conductivity of the grouting materials from 0.818 to $1.104W/m^{\circ}C$ resulted in overall increases in effective thermal conductivity by 15.8 to 56.3% and reductions in effective thermal resistance by 13.0 to 31.1%.

지중열 이동 시뮬레이션을 이용한 수평형 지열시스템의 채열성능 예측 (Prediction of the Heat Exchange Rate for a Horizontal Ground Heat Pump System Using a Ground Heat Transfer Simulation)

  • 남유진;채호병
    • 설비공학논문집
    • /
    • 제25권6호
    • /
    • pp.297-302
    • /
    • 2013
  • The ground source heat pump (GSHP) system has attracted attention, because of its stability of heat production, and the high efficiency of the system. However, there are few studies on the prediction method of the heat exchange rate for a horizontal GSHP system. In this research, in order to predict the performance of a horizontal GSHP system, coupled simulation with a ground heat transfer model and a heat exchanger circulation model was developed, and calculation of heat exchange rate was conducted by the developed tool. In order to optimally design the horizontal GSHP system, the flow rate of circulation water, and the depth and buried spaces of heat exchangers were considered by the case study. As a result, the temperature of circulation water and the heat exchange rate of the system were calculated in each case.

지열히트펌프와 지역냉난방 시스템의 운영사례를 중심으로 경제성 비교분석 연구 (A Study of Comparative Economic Evaluation for the System of Ground Source Heat Pump and District Heating and Cooling:Focusing on the Analysis of Operation Case)

  • 이기창;홍준희;공형진
    • 설비공학논문집
    • /
    • 제28권3호
    • /
    • pp.103-109
    • /
    • 2016
  • The purpose of this study is to perform comparative economic evaluation for the systems of ground source heat pump (GSHP) and district heating and cooling (DHC) by focusing on the analysis of operation case of GSHP. The adapted research object is a public office building located in Seoul. The capacity of ground source pump is about 3,900 kW. Ground heat exchanger is closed loop type. The analysis period for life cycle cost is 30 years. Economic evaluation is assessed from the viewpoints of the following four parts: initial cost, energy cost, maintenance and replacement cost, and environment cost. The total life cycle cost of GSHP is approximately 8,447 million won. The cost of the DHC System is approximately 3,793 million won. The cost of the DHC is approximately 46% lower than GSHP system under the condition of current rate for GSHP and DHC.

건식정제에 의한 견운모광의 품위향상연구 (Improvement in Grade of Sericite Ore by Dry Beneficiation)

  • 조건준;김윤종;박현혜;조성백
    • 한국재료학회지
    • /
    • 제19권4호
    • /
    • pp.212-219
    • /
    • 2009
  • A study on the dry beneficiation of sericite occurring in the Daehyun Mine of the Republic of Korea region as performed by applying selective grinding and air classification techniques. Quartz and sericite occurred in the raw ore as major components. The results of liberation using a ball mill and an impact mill showed that the contents of $R_2O$ were increased while $SiO_2$ was decreased in proportion to decreasing particle size. According to the XRD, XRF analysis and the EDS of SEM analysis, the ball mill gave a better grade product in $R_2O$ content than the impact mill when the particle size was the same. When the raw ore was ground by the impact mill with arotor speed 57.6 m/sec and then followed by 15,000rpm classification using an air classifier, the chemical composition of the over flowed product was 49.65wt% $SiO_2$, 32.15wt% $Al_2O_3$, 0.13wt% $Fe_2O_3$, 10.37wt% $K_2O$, and 0.14wt% $Na_2O$. This result indicates that the $R_2O$ contents were increased by 49.5% compared to that of the raw ore. From these results described above, it is suggested that hard mineral such as Quartz little ground by selective grinding using impact mill whereas soft mineral such as sericite easily ground to small size. As a result of that hard minerals can be easily removed from the finely ground sericite by air classification and the $R_2O$ grade of thus obtained concentrate was improved to higher than 10wt% which can be used for ceramics raw materials.

소프트웨어 오류 추정 기법을 활용한 공대지 사격 오류 요인 분석 모델 (The Fault Analysis Model for Air-to-Ground Weapon Delivery using Testing-Based Software Fault Localization)

  • 김재환;최경희;정기현
    • 한국시뮬레이션학회논문지
    • /
    • 제20권3호
    • /
    • pp.59-67
    • /
    • 2011
  • 본 논문에서는 오류 검출을 위해 소프트웨어 오류 추정 기법을 활용하여 항공무장 시스템인 공대지 사격의 오류 요인을 분석하기 위한 모델을 제시하고 모델을 기반으로 오류 요인 영향을 분석하였다. 선행 연구에서는 공대지 무기체계의 정확도에 영향을 미치는 오류 요소를 분석하고 결함위치추정 기법인 FBEL(Factor-based Error Localization) 기법을 제안하였으며 실사격 자료에 적용하여 오류 요소를 분석하였다. 그러나 다양한 요인 중 하나의 요인인 정확도를 고정하여 적용하므로 다양한 사격 정확도 변화에 따른 사격 오류 발생 요소와의 상관관계는 밝히지 못하였다. 본 연구에서는 사격 오류 요소의 상관관계 분석을 통하여 보다 세밀한 오류 분석 모델을 제시하고 시간과 비용이 제한적이거나 테스트 케이스가 적은 상태에서 오류 발생 가능 요소를 추정하는 방법을 제안한다. 제안된 방법은 실사격 자료를 이용한 시뮬레이션을 통해 그 효용성을 입증하였으며, 무기체계 공대지 시험평가에서 어떤 요소들이 정확도에 영향을 미치는 지를 분석하는데 성공적으로 활용될 수 있음을 보였다.

에너지플러스 시뮬레이션을 통한 하천수 열원 히트펌프 시스템의 적용 가능성 분석 (An Applicability Analysis of River Water Source Heat Pump System using EnergyPlus Simulation)

  • 손병후
    • 한국지열·수열에너지학회논문집
    • /
    • 제18권2호
    • /
    • pp.10-21
    • /
    • 2022
  • A water source heat pump (WSHP) system is regarded as an energy-efficiency heating and cooling supply system for buildings due to its high energy efficiency and low greenhouse gas emissions. Recently, water sources such as river water, lake water, and raw water are attracting attention as heat sources for a heat pump system in Korea. This paper analyzed the applicability of a river water source heat pump system (RSHP). The river water temperature level was compared with the outdoor air and ground temperature levels to present applicability. In addition, the cooling and heating performance were compared through a simulation approach for the RSHP and a ground source heat pump (GSHP) applied to a large-scale office building. To compare the temperature level, the actual data were applied to the river water and the outdoor air, while the simulation results were applied to the ground circulation water. The results showed that the change in river water temperature throughout the year was similar to the change in outdoor air temperature. However, unlike the outdoor air temperature, the difference between the hourly and daily average river water temperatures was not large. The temperature level of river water was lower during the heating season and somewhat higher during the cooling season than that of the ground circulation water. Finally, the performance of the RSHP system was 13.4% lower than that of the GSHP system on an annual-based.

지구온난화에 따른 지열히트펌프와 공기열히트펌프의 성능 변화 분석 (Analysis of Performance Changes in Ground source Heat Pump and Air Source Heat Pump According to Global Warming)

  • 서진영;함세현;이동찬
    • 한국지열·수열에너지학회논문집
    • /
    • 제19권4호
    • /
    • pp.8-17
    • /
    • 2023
  • The air temperature is gradually increasing owing to global warming, especially in summer, therefore, the performance of an air source heat pump (ASHP) is expected to be decreased. Accordingly, the performance gap between the ASHP and ground source heat pump (GSHP) should be increased, however, the quantitative comparison has not been yet investigated. In this study, impact of global warming on the performance of the ASHP and GSHP is investigated based on the climate data for 1930, 1980, and 2030. The coefficient of performance (COP) as well as annual power consumption of the ASHP and GSHP are compared and analyzed. In the case of COP, the COP of GSHP hardly changes over the years owing to the constant ground temperature, while that of ASHP decreases by 3.7% for cooling and increases by 0.71% for heating. In the case of annual power consumption, the cooling and heating power consumption of GSHP increases by 12.69% and decreases by 15.58%, respectively, over the year owing to the changes in heating and cooling loads. As for the ASHP, the cooling and heating power consumption increases by 16.64% and decreases by 17.8%, respectively. For a more accurate comparison, power consumption ratio is introduced and shows that total annual power consumption of the GSHP to ASHP decreased from 68% in 1930 to 65% in 2030. Therefore, as global warming accelerates, the effect of reducing power consumption by using GSHP compared to ASHP is expected to be increasing.