• 제목/요약/키워드: air-flow system

검색결과 2,491건 처리시간 0.032초

Energy Auditing Using a Building Energy Simulation Program BLDSYM

  • Lee, E.J.;Yoon, J.H.;Kang, Y.H.;Jeon, H.S.
    • 태양에너지
    • /
    • 제15권3호
    • /
    • pp.53-58
    • /
    • 1995
  • The objectives of this study are to introduce the energy simulation program BLDSYM, to verify the approach, and to demonstrate the energy saving opportunities. A case study model for Hoover Middle School, OK, USA has been introduced as a base case simulation. Air-side variable air volume(VAV) and water-side variable flow hydronic(VFH) system have been recommended, modeled and simulated to quantify the energy savings compared with the base system, which is typically constant air and water flow system. More than 30% of energy savings could be obtained with the optimum variable flow system.

  • PDF

Energy Simulation for Energy Saving Opportunities

  • Lee, E.J.;J.H. Yoon;Y.H. Kang;H.S. Jeon
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1995년도 춘계학술발표회 초록집
    • /
    • pp.88-93
    • /
    • 1995
  • The purpose of this study is to introduce the energy simulation program BLDSYM, verify the approach. and demonstrate the energy saving opportunities. A case study model for Hoover Middle School, OK USA has been introduced as a base case simulation. Air-side variable air volume (VAV) and water-side variable flow hydronic (VFH) system have been recommended, modeled and simulated to quantify the energy savings compared with the base system, which is typically constant air and water flow system. More than 30 % of energy savings could be obtained with the optimum variable flow system.

  • PDF

평행유동에서 공랭식 열전모듈 냉각시스템의 성능에 관한 연구 (A Study on Performance of Thermoelectric Air-Cooling System in Parallel Flow)

  • 강상우;신재훈;한훈식;김서영
    • 설비공학논문집
    • /
    • 제23권6호
    • /
    • pp.421-429
    • /
    • 2011
  • Experimental and theoretical studies on cooling performance of two-channel thermoelectric air-cooling system in parallel flow are conducted. The effects of operating temperature to physical properties of thermoelectric module (TEM) are experimentally examined and used in the analysis of an air-cooling system considering thermal network and energy balance. The theoretical predicted temperature variation and cooling capacity are in good agreement with measured data, thereby validating analytic model. The heat absorbed rate increases with increasing the voltage input and decreasing thermal resistance of the system. The power consumption of TEM is linearly proportional to mean temperature differences due to variations of the physical properties on operation temperature of TEM. Furthermore thermal resistance of hot side has greater effects on cooling performance than that of cold side.

냉동시스템의 운전조건에 따른 열교환기 내장형 어큐뮬레이터의 성능 특성 (Performance Characteristics of Accumulator Heat Exchangers with Operating Conditions of a Refrigeration System)

  • 강훈;박차식;전종욱;김용찬
    • 설비공학논문집
    • /
    • 제18권12호
    • /
    • pp.984-991
    • /
    • 2006
  • The applications of multi air-conditioners into multiplex and high-rise buildings have been increased by replacing central air-conditioning systems. The pipe length and altitude difference between the indoor and outdoor units can be increased based on installation conditions, which may increase the possibility of flash gas generation at the expansion device inlet. The flash gas generation causes rapid reduction of refrigerant flow rate passing through the expansion device, yielding lower system efficiency. Accumulator heat exchangers have been widely used in multi air-conditioners in order to minimize flash gas generation and obtain system reliability. However, the studies on the heat transfer characteristics and pressure drops of accumulator heat exchangers are very limited in open literature. In this study, the heat transfer rates and pressure drops of accumulator heat exchangers were measured with refrigerant flow rate and operating conditions by using R-22. The heat transfer rate increased with the increase of refrigerant flow rate, while subcooling decreased. The heat transfer rate enhanced with the reduction of inlet superheat and subcooling due to the increased temperature difference between the accumulator and inner heat exchanger.

고온측 냉매에 따른 이원 냉동시스템의 성능 분석 (Performance Analysis of Cascade Refrigeration System with Respect to Refrigerants Appling to High Temperature Cycle)

  • 윤정인;전민주;손창효
    • 동력기계공학회지
    • /
    • 제21권3호
    • /
    • pp.45-50
    • /
    • 2017
  • This paper presents the Coefficient of performance(COP) and mass flow ratio of cascade refrigeration system with respect to refrigerants appling to high temperature cycle. The operating parameters considered in this study include degree of superheating and subcooling, compressor efficiency, evaporating temperature, condensing temperature and internal heat exchanger effectiveness in high temperature cycle. The result of this study is as follows : The COP of cascade system increases with increasing degree of superheating and subcooling, compressor efficiency and internal heat exchanger effectiveness except increasing condensing temperature. The mass flow ratio of low and high temperature cycle increases with increasing evaporating temperature and condensing temperature, but decreases with increasing internal heat exchanger effectiveness, degree of superheating and subcooling. Also, the mass flow ratio has no correlation with compressor efficiency at high temperature cycle.

수모델 실험을 이용한 전통 탕구계의 유동 양상에 미치는 필터의 영향 연구 (A Study on the Effects of the Filter on Flow Pattern of the Traditional Gating System by the Water Modeling Experiment)

  • 황호영;남철희;최영심;홍준호
    • 한국주조공학회지
    • /
    • 제36권6호
    • /
    • pp.208-214
    • /
    • 2016
  • Casting defects, which are closely related to entrapped air bubbles and metallic oxides, occur very frequently in the casting process. Many researchers have shown that these defects can be reduced by adopting an appropriate gating system design. But, it is difficult for field engineers to identify a specific gating system that is more appropriate for their products. In this study, we tried to draw a comparison of gating system designs with and without ceramic foam filters. A ceramic foam filter was added to the horizontal runner just after the sprue to prevent air bubble generation and to reduce turbulence without change of the gating system design. To verify the effects of initial pouring velocity, the experiment was conducted with four different amounts of water volume in the reservoir. Results of the water modeling experiment applying the filter showed remarkably changed flow characteristics. Although the study confirmed that use of the filter may change the flow characteristics, it needs to be noted that only filter use alone cannot solve all the problems caused by a poorly designed gating system.

자동차 공조용 핀형 열교환기의 성능특성에 관한 연구 (A Study on the Performance Characteristics of Fin-type Heat Exchanger for the Automobile Air-Conditioners)

  • 홍경한;전상신;이승재;박찬수;권일욱;김재열;김병철;하옥남
    • 한국공작기계학회논문집
    • /
    • 제13권4호
    • /
    • pp.100-105
    • /
    • 2004
  • Fin-tube type(Fin-type) heat exchanger has been tested in order to replace the heat exchanger of parallel flow type(P.F -type) which is now widly used in automobile air conditioning system The following conclusions are drawn by the comparison of the characteristics of the heat exchangers. Evaporator and condenser capacities and COP(Coefficience of performance) were varied as with the compressor speed, outdoor air temperature and air flow rate changed, which much influenced on the characteristics of the air conditioning system Evaporator and condenser capacities were increased with increasing compressor speed and outdoor air temperature. Evaporator and condenser pressures of Fin-type were decreased by 7% and 5% respectively compared with those of P.F-type. The COP of Fin-type was decreased with increasing outdoor air temperature and compressor speed. The COP of P.F-type was decreased by 14% compared with that of Fin-type.

랩온어칩 내부 미세유동제어를 위한 새로운 유동제어기법 (A New Flow Control Technique for Handling Infinitesimal Flows Inside a Lab-On-a-Chip)

  • 한수동;김국배;이상준
    • 대한기계학회논문집B
    • /
    • 제30권2호
    • /
    • pp.110-116
    • /
    • 2006
  • A syringe pump or a device using high electric voltage has been used for controlling flows inside a LOC (lab-on-a-chip). Compared to LOC, however, these microfluidic devices are large and heavy that they are burdensome for a portable ${\mu}-TAS$ (micro total analysis system). In this study, a new flow control technique employing pressure regulators and pressure chambers was developed. This technique utilizes compressed air to control the micro-scale flow inside a LOC, instead of a mechanical actuator or an electric power supply. The pressure regulator controls the output air pressure by adjusting the variable resistor attached. We checked the feasibility of this system by measuring the flow rate inside a capillary tube of $100{\mu}m$ diameter in the Re numbers ranged from 0.5 to 50. In addition, the performance of this flow control system was compared with that of a conventional syringe pump. The developed flow control system was found to show superior performance, compared with the syringe pump. It maintains automatically the: air pressure inside a pressure chamber whether the flow inside the capillary tube is on or off. Since the flow rate is nearly proportional to the resistance, we can control flow in multiple microchannels precisely. However, the syringe pump shows large variation of flow rate when the fluid flow is blocked in the microchannel.

환형 이젝터 루프 내부의 이상유동특성 파악을 위한 수치해석 및 유동가시화 연구 (Numerical Analysis and Flow Visualization Study on Two-phase Flow Characteristics in Annular Ejector Loop)

  • 이동엽;김윤기;김현동;김경천
    • 한국가시화정보학회지
    • /
    • 제9권4호
    • /
    • pp.47-53
    • /
    • 2011
  • A water driven ejector loop was designed and constructed for air absorption. The used ejector was horizontally installed in the loop and annular water jet at the throat entrained air through the circular pipe placed at the center of the ejector. Wide range of water flow rate was provided using two kinds of pumps in the loop. The tested range of water flow rate was 100${\ell}$ /min to 1,000 ${\ell}$/min. Two-phase flow inside the ejector loop was simulated by CFD analysis. Homogeneous particle model was used for void fraction prediction. Water and air flow rates and pressure drop through the ejector were automatically recorded by using the LabView based data acquisition system. Flow characteristics and air bubble velocity field downstream of the ejector were investigated by two-phase flow visualization and PIV measurement based on bubble shadow images. Overall performance of the two-phase ejector predicted by the CFD simulation agrees well with that of the experiment.

단거리 대공방어유도탄체계와 이기종 함정 전투체계간 최적의 연동 설계 기법 (Optimal Interface Design between Short-Range Air Defense Missile System and Dissimilar Combat Systems)

  • 박현우
    • 한국군사과학기술학회지
    • /
    • 제18권3호
    • /
    • pp.260-266
    • /
    • 2015
  • The warship is run based on the combat system which shares tactical information collected by target detection systems and navigation devices across a network, and conducts the command and control of weapons from target detection to kill assessment. The short-range air defense missile system defends a warship from anti-ship missiles, aircraft, helicopter and other threats in order to contribute to the survival of a warship and the success of missions. The short-range air defense missile system is applied to a various combat systems. In this paper, we have proposed the interface design between the short-range air defense missile and dissimilar combat systems. To employ the short-range air defense missile at dissimilar combat systems, each system is driven by independent processor, and the tasks which are performed by each system are assigned. The information created by them is exchanged through the interface, and the flow of messages is designed.