• 제목/요약/키워드: air-duct cooling

검색결과 59건 처리시간 0.019초

철도 차량의 HVAC 위치에 따른 공기조화 시스템 및 Air Duct 구조의 특성에 관한 고찰 (A Survey for the Air Treatment System according to the Position of HVAC and the Feature of Air Duct Structure in the Train)

  • 정화식;박재홍;염규학
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1330-1335
    • /
    • 2007
  • The HVAC and the air duct is to make optimal indoor environment. By the HVAC position, method and the air duct construction, the important elements can affect on cooling performance, passengers' convenience, and energy efficiency. According to this, there are features, such as the indoor temperature distribution, cooling performance, velocity distribution from diffuser, tend to be come out variously. Also, comparing and analysing temperature distribution, cooling performance, air velocity, noise based on the real practical vehicle tests, it shows features in detail. Besides, it can lead to make design the system of HVAC & air duct effectively.

  • PDF

Design of Solar Cell Cooling System Using Convection Phenomena

  • Lee, Jae-hyuk
    • International journal of advanced smart convergence
    • /
    • 제9권2호
    • /
    • pp.123-128
    • /
    • 2020
  • We constructed a cooling system for solar cells using convection phenomena and investigated its cooling performance. The cooling system didn't need any driving power or water resources. The convection cooler manufactured with a right-triangle shape of an air duct was attached to the rear of the solar cell to confirm that cooling was performed using convection phenomena. When the ratio of duct width to attachment surface width was 3:7, and the ratio of entrance height and exit height of duct was 5:1, it showed the best cooling performance. Comparative experiments with solar cells without convection cooler showed that cooling effects from 16.5℃ to 20.9℃ occurred after 40 minutes exposed to the 1300W Xenon lamp condition.

DEVELOPMENT OF NIGHT COOLING SYSTEM FOR GREENHOUSE USING COOL AIR AND WATER FROM AN ABANDONED COAL MINE

  • Whoa S. Kang;Wie S. Kang;Lee, Gwi H.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1996년도 International Conference on Agricultural Machinery Engineering Proceedings
    • /
    • pp.1136-1145
    • /
    • 1996
  • This study was to develop the most effective cooling system which is needed to cool greenhouse during summer night to get early blooming of strawberries. Various cooling systems were designed and constructed to utilize the cool air and water from tan abandoned coal mine. Cooling systems built for this study were an evaporative cooling system with pad, cooling system using a small or large radiator , and duct cooling system using cool are drawn from coal mine. These systems were individual tested to investigate their effects on cooling greenhouse during summer night. Also, a combined cooling system was tested with operating an evaporative cooling system, small radiator, and duct cooling system simultaneously. The results in this study showed that individual cooling systems such as evaporative cooling system, small radiator, and cooling duct had about the same effect on cooling greenhouse. The combined system had little better cooling effect than that of individual cooling syst m except the large radiator . The most effective system for cooling of greenhouse was obtained with using a large a large radiator as the heat exchanger. With operating a large radiator, temperature inside the greenhouse was dropped to about 15-16$^{\circ}C$ while outside temperature was 23-24$^{\circ}C$ during summer night.

  • PDF

축류 팬을 이용한 충돌제트 전자냉각 설계개념에 대한 연구 (Study on the Design Concept of Impinging Jet Electronics Cooling by Using Axial Fan)

  • 이찬;길현권
    • 한국유체기계학회 논문집
    • /
    • 제12권2호
    • /
    • pp.24-30
    • /
    • 2009
  • Flow and noise analyses are conducted for examining a new design concept of impinging jet electronics cooling, and the analysis results are compared with conventional electronics cooling techniques. For the application of impinging jet electronics cooling method, the present study considers the air duct where air is supplied by axial fan and air flow from the duct is impinged vertically onto the electronic component heat source. Applying CFD simulation technique and fan noise model to the present cooling scheme, the cooling performance of the impinging jet as well as the operation condition and the noise characteristics of fan are investigated for various impinging jet nozzle conditions and fan models. Furthermore, the impinging jet electronics cooling analysis results are compared with the conventional parallel-flow cooling scheme to give the design concept and criteria of impinging jet cooling method.

자동차 냉/난방 성능 향상을 위한 공기조화 덕트의 기류해석 (Aerodynamic Analysis of Automotive HVAC Duct for Enhancement of Cooling/Heating Performance)

  • 주재우;이기돈;허만웅;김광용;박준규;윤정환;김홍빈
    • 설비공학논문집
    • /
    • 제24권1호
    • /
    • pp.23-28
    • /
    • 2012
  • In the present work, numerical analyses of air flow in HVAC duct have been carried out for enhancement of cooling/heating performance. For the analyses, three-dimensional Reynolds-averaged Navier-Stokes equations have been solved with the shear stress transport turbulence model. The numerical results were validated in comparison with the experimental data. Based on the numerical results, the HVAC duct was designed to reduce the pressure loss. The modified duct geometry shows largely reduced pressure drop in comparison with the reference geometry. And, through modified duct shape, the performance of air conditioning has been enhanced.

전동차 공조기 덕트 내의 유동특성에 관한 수치해석적 연구 (Numerical study on the flow characteristics in Air-conditioner duct of EMU)

  • 김승택;김성종;박근수;박형순
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 추계학술대회 논문집(III)
    • /
    • pp.345-350
    • /
    • 2003
  • The inside of EMU is supplied with the cooling air from air-conditioner and the fresh air from exterior through the air-conditioner duct which is one of the air conditioning system. The shape of air-conditioner duct is a major factor in determining the air-conditioning efficiency, thermal comfort and energy efficiency. Therefore, this study is to understand the flow characteristics in the air-conditioner duct by three dimensional numerical simulation. The air-conditioner duct was calculated for the design volume flow rate, $2,726\;m^3/h/unit$. From the result of calculation and measurement, the velocity at diffuser outlet presented good agreement in general. [n this present study, the calculation was also performed for three volume flow rate(1,800, 2,200, 3,000 $m^3/h/unit$) and total pressure characteristic curve with volume flow rate was presented.

  • PDF

폐광의 냉기 및 냉수를 이용한 온실의 야냉 시스템 개발 (Development of Night Cooling System for Greenhouse Using Cool Air and Water from an Abandoned Coal Mine)

  • 강화석;강위수;이귀현;오재헌;김일섭;류근창
    • 한국환경농학회지
    • /
    • 제15권2호
    • /
    • pp.223-231
    • /
    • 1996
  • 폐광으로부터 유출되는 냉기 또는 냉수를 이용하여 여름 동안 야간에 온실을 냉방시키는데 있어 가장 효율적인 냉각방법을 결정하기 위해 여러 종류의 냉각 장치가 제작 및 냉각 실험되어졌다. 온실을 냉방시키는데 있어 여러 냉각장치의 효율을 비교할 때 독립적으로 소형 radiator, 냉각 pad 및 냉기를 사용한 냉각방법은 거의 비슷한 결과를 나타냈다. 또한 대형 radiator를 제외한 여러 냉각장치를 동시에 가동하였을 때는 독립적으로 이러한 냉각장치를 각각 가동하였을 때 보다 약간 향상된 냉각 효율을 나타냈다. 그러나 대형 radiator를 독립적으로 사용했을 때 온실의 냉각 효율은 다른 냉각 방법에 비하여 상당히 좋았으며, 야간의 외기 온도가 $23-24^{\circ}C$ 범위에 있을 때 온실내의 공기 온도는 약 $15^{\circ}C$로 냉각되었다.

  • PDF

Measurements of Ventilation Effectiveness in an Underfloor Air-Conditioned Space Using a Tracer Gas Technique

  • Han, Hwa-Taik;Seo, S.Y.;Kim, M.H.;Kim, Young-Il
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제7권
    • /
    • pp.91-100
    • /
    • 1999
  • This paper investigates ventilation characteristics of an environmental chamber simulating an under-floor air conditioning system for isothermal and cooling supply air conditions. The tracer gas sulfur-hexafluoride (SF$F_6$) was injected into a supply duct using step-up and step-down methods. Local mean and room mean ages were calculated from the concentrations measured at internal points and at the exhaust duct. The air change efficiency of the chamber has been found to be greater in cooling conditions than in isothermal conditions. Also the room air change efficiency is not significantly affected but slightly improved by the presence of a supply diffuser.

  • PDF

일체형 팬 앤 패드 시스템과 에어 덕트를 이용한 온실 냉방 (Greenhouse Cooling Using Air Duct and Integrated Fan and Pad System)

  • 남상운;김영식
    • 생물환경조절학회지
    • /
    • 제20권3호
    • /
    • pp.176-181
    • /
    • 2011
  • 온실의 한쪽 벽에 패드를 설치하고 반대쪽 벽에 팬을 설치하여 가동하는 팬 앤 패드 냉방 온실의 온도 경사 문제를 극복하기 위한 목적으로 일체형 팬 앤패드 시스템과 에어 덕트를 설치한 온실의 냉방 실험을 통하여 냉방성능을 분석하였다. 일체형 팬 앤 패드 증발냉각기의 효율은 1단 가동시 75.7%, 2단 가동시 88.6%로 나타나 대체로 우수한 냉각효율을 보이는 것으로 판단된다. 온실의 냉방성능 실험 결과 무차광 조건에서 온실 냉방 시스템을 가동할 경우 대조구 온실에 비해서 $5.7\sim7.6^{\circ}C$ 정도의 냉방효과가 있으며 차광 조건에서는 $7.4\sim9.7^{\circ}C$ 정도의 냉방효과가 있는 것으로 나타났다. 본 시스템을 적용할 경우 여름철 온실의 최고기온을 $37^{\circ}C$ 정도로써 외기온 대비 $5^{\circ}C$ 이내로 유지할 수 있으며, 적절한 차광을 실시할 경우에는 $33^{\circ}C$ 정도에 $2^{\circ}C$ 이내로 유지하는 것이 가능하여 고온기 작물재배에 큰 도움을 줄 수 있을 것으로 생각한다. 한편, 본 냉방 실험에서 온실의 온도 분포를 분석한 결과 18m 길이의 온실 내 최대 온도 편차는 차광시 $1.6\sim1.7^{\circ}C$, 무차광시 $2.3\sim2.7^{\circ}C$ 정도로 나타났다. Kittas 등(2003)과 Nam 등(2005)의 자료와 비교한 결과 본 연구에서 구상한 일체형 팬 앤 패드 시스템과 에어 덕트를 이용한 온실 냉방시스템은 기존의 팬 앤 패드 냉방 온실의 최대 단점인 온도 편차를 40~50% 정도 개선할 수 있는 것으로 나타났다. 본 시스템은 자연환기 상태에서 가동할 수 있으므로 단동 온실에 적용하기가 쉬우며, 일체형 증발냉각기 출구로부터 온실 내 에어 덕트 시점까지의 연결 덕트 부분을 철저하게 단열하면 냉방성능을 더욱 향상시킬 수 있을 것으로 판단된다.

차량 엔진룸내 부품 냉각용 덕트 개발을 위한 실험 (Experiment for Duct Development to Cool Components in Vehicle Engine Room)

  • 이석영
    • 에너지공학
    • /
    • 제27권4호
    • /
    • pp.98-102
    • /
    • 2018
  • 자동차 엔진룸내 부품의 내구성 향상을 위하여 냉각 가능성을 판단하고자 발전기, 배터리, ECU 및 파워스틸 오일 등 4가지 부품을 목표로 흡입공기를 사용한 냉각용 덕트를 설치하여 부품에 대한 공랭효과를 향상시키기 위한 실험을 수행하였다. 실험 결과, 전반적으로 부품 온도가 저감되었으며 감소된 온도 차이는 발전기, ECU, 파워스틸 오일 및 배터리 순으로 크게 나타났다. 이러한 부품에 따른 온도 차이를 개선하기 위해서는 차후에 덕트 내부에 대한 유동해석을 통한 최적화 설계가 필요하다고 판단된다.