• Title/Summary/Keyword: air-dry

Search Result 1,461, Processing Time 0.03 seconds

Modified Atmosphere Packaging of Dry Jujube (건조 대추의 변형기체포장)

  • 하정욱;이동선
    • Food Science and Preservation
    • /
    • v.4 no.3
    • /
    • pp.265-270
    • /
    • 1997
  • Effect of modified atmosphere packaging conditions on quality changes of dry jujube was investigated. Dry jujubes with moisture content of 26.7% were packaged in PET/Al/PE film pouches with modified atmospheres. The tested packages include those with normal air, vacuum, CO2 flushing, N2 flushing and O2 scavenger. Packages were stored at 25$^{\circ}C$ for 6 months, during which ascorbic acid concentration, browning level, titratable acidity and surface color were measured. Generally modified atmosphere packages could improve quality retention of dry jujubes except that vacuum package resulted in large surface color change. CO2-flushed package showed the best quality retention of high ascorbic acid content and low browning during 112 days, but caused high amounts of ascorbic acid destruction and browning in longer storage. In all the modified atmosphere packages titratable acidity reached a maximum followed by decline and subsequent rise, while it increased linearly with time in normal air package. Considering ascorbic acid retention browning level and surface color changes during 112 days, the packages of CO2 flushing and N2 flushing were better than others.

  • PDF

A Simulation for Dry Depositon Velocity of Air Pollutants over various surfaces. (지표 부근에서의 대기오염물질 건성 침적속도에 관한 모수화)

  • 이화운;박종길
    • Journal of Environmental Science International
    • /
    • v.3 no.4
    • /
    • pp.367-372
    • /
    • 1994
  • A predictive model is demonstrated for gas removal rates from the aklosphere by dw deposition. Typical deposition velocities are complex functions of surface types, atmospheric stabilities, friction velocities, air pollutants, and so on. In this paper we simulated the calculation of dry deposition velocities near the earth surfaces, simultaneously we estimated real dry deposition velocities using the previous simulation. The measurement taken over a deciduous forest by Padro et d.(1988) were used to verify this model. In the comparison of the value of deposition velocity between numerical computation and observation, there are partially overestimations and underestimations between them, but we can speak that they are in a good accordance.

  • PDF

Numerical Analysis of Moisture Ventilation in the Dry Room (Dry room내 수분환기에 대한 수치적 연구)

  • 이관수;임광옥;정영식
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.10
    • /
    • pp.908-916
    • /
    • 2000
  • In this paper, the characteristics of moisture ventilation in the lithium ion battery manufacturing dry room are studied numerically using standard $k-\varepsilon$ turbulence model. Both the steady-state and the unsteady behaviors of moisture ventilation are analyzed by considering local and uniform moisture generation. In order to evaluate the characteristics of moisture ventilation, three scales of ventilation efficiency and characteristic ventilation time are presented from the numerical results. It was shown that moisture distribution was dependent strongly on the flow field. The characteristics of moisture ventilation were improved by 20% and 40% in terms of the 1st scale of ventilation efficiency (SVE1) and the 2nd scale of ventilation efficiency (SVE2), respectively, through the modifications of design variables such as the addition of inlets, outlets and partition. A significant improvement in the characteristic ventilation time and the moisture exhaust efficiency was also made by these modifications.

  • PDF

A Numerical Study on the Performance Analysis of the Plume Abatement NWD Cooling Tower (백연 방지를 위한 NWD냉각탑의 성능해석에 관한 수치해석적 연구)

  • 최창혁;최영기;소헌영
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.11
    • /
    • pp.1049-1058
    • /
    • 2001
  • The performance and design analysis for a NWD cooling tower using a combined wet and dry type fill are numerically investigated and compared with the experimental results. The Stoecker's method is applied to the wet section and LMTD or NTU-Effectiveness method to the wet and dry sections. The efficiency ratio of the NWD cooling tower to a wet type crossflow cooling tower is 59.34%. The predicted result shows a good agreement with the experimental data within 1.4% error. Plume abatement is far better with a NWD cooling tower than a counterflow cooling tower. It costs less than a conventional wet/dry tower because the finned exchanger is eliminated. This method also leaves out complexity in structure and Intricacy in operation.

  • PDF

A Temporal Trend of Dioxins Levels in Environmental Media

  • Park, Kyunghee;Daeil Kang;Junheon Youn;Lee, Choong;Sunghwan Jeon;Jingyun Na
    • Proceedings of the Korea Society of Environmental Toocicology Conference
    • /
    • 2003.05a
    • /
    • pp.148-148
    • /
    • 2003
  • This study is to investigate the environmental levels and trend of dioxins, which was the 3$\^$rd/ year of environmental monitoring research for endocrine disrupting chemicals since 1999. Total 282 samples were analyzed from 115 sites including 26 sites of airs, 43 sites of waters, 11 sites of sediments and 35 sites of soil, which were the same as those of investigated sites in 2000. Sampling period was from June 2001 to June 2002. Target chemicals were seventeen species of 2,3,7,8-chlorine-substituted PCDD and PCDF congeners and were analyzed by the standard methods, established by National Institute Environmental Research (NIER). The average concentration of dioxins in air decreased from 0.324 pg-TEQ/N㎥ in 2000 to 0.287 pg-TEQ/N㎥ in 2001, and those in water and soil were 0.073pg-TEQ/L and 1.703pg-TEQ/dry g, respectively, which was the less values detected in 2000. In sediment, however, the value was 0.086pg-TEQ/dry g, which was the increase from the value of the year 2000. The concentration range of dioxins in air for 26 sites in 17 regions detected were 0.013∼l.664pg-TEQ/N㎥, 4 sites from those were exceeded the Air Quality Standards of Dioxin in Japan (0.6 pg-TEQ/N㎥). The tolerable daily intake of dioxins was calculated at the highest level (1.664) in air, with referring the soil and food data from Japan, was calculated to be 2.85pg-TEQ/kg/day, which was below the level of 4 pg-TEQ/kg/day suggested in KFDA(Korea). While the average concentration of dioxins in 15 big cities was 0.190 pg-TEQ/N㎥, that in 8 medium/small cities constituting an industrial complex was 0.558 pg-TEQ/N㎥. In water, the concentration range detected were 0∼0.946pg-TEQ/L and the trend of the average concentrations shows an increase from those of 1999 but decreased from those of 2000, any sites however were not exceeded the Water Quality Standards of Dioxin in Japan (1 pg- TEQ/L). In soil. the detected range were 0∼43.333 pg-TEQ/dry g and the average concentration decreased, compared with the results of 2000. According to the monitoring results by land utilization, the detected range were 0∼43.333pg-TEQ/dry g in farmland, 0.017∼0.601 pg-TEQ/dry g in the industrial area, 0.005∼0.049pg-TEQ/dry g in the park and 0.008∼1.825 pg-TEQ/dry g in the rest. In sediment, the detected range increased from 0∼0.244 pg-TEQ/dry g to 0∼0.537 pg-TEQ/dry g, based on the results of 2000. For the proper control of dioxins, continuous monitoring needs to be performed and in addition, the dioxin inventory should be prepared for major sources through the dioxin emission survey. These results would provide sound and solid basis for proper decision making of dioxins management like establishment of environmental quality standards in Korea.

  • PDF

Application of Cationic PVAm - Anionic PAM Dry Strength Aids System on a Kraft Paper Mill (양이온성 PVAm - 음이온성 PAM 건조지력증강제 시스템의 크라프트지 적용 사례)

  • Cho, Byoung-Uk;Ryu, Jeong-Yong;Son, Dong-Jin;Song, Bong-Keun
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.42 no.3
    • /
    • pp.50-57
    • /
    • 2010
  • A mill trial was performed in a kraft paper mill in order to evaluate the possibility of utilizing dual polymer dry strength aids system consisting of cationic PVAm and anionic PAM. It was found that the cationic PVAm - anionic PAM dry strength additives can improve paper strength without significantly disturbing the stability of the kraft papermaking process when virgin UKP was used as a furnish. Tensile strength (25.3% in machine direction, 48.4% in cross machine direction), elongation of paper (31.6%, 15.6%) and tensile energy absorption (48%, 54%) were improved. Air permeability of the kraft paper was improved as well (22%). Tear strength was decreased with PVAm dry strength aids system, but it can be compensated with decreasing refining degree. In addition, the mill trial results indicate that highly air permeable kraft sack paper can be produced by the addition of PVAm dry strength agents at the stock with reduced freeness.

Experimental study on the generation of ultrafine-sized dry fog and removal of particulate matter (초미세 크기의 마른 안개 생성과 이를 이용한 미세먼지 제거 연구)

  • Kiwoong Kim
    • Journal of the Korean Society of Visualization
    • /
    • v.22 no.1
    • /
    • pp.34-39
    • /
    • 2024
  • With the fine particulate matter (PM) poses a serious threat to public health and the environment. The ultrafine PM in particular can cause serious problems. This study investigates the effectiveness of a submicron dry fog system in removing fine PM. Two methods are used to create fine dust particles: burning incense and utilizing an aerosol generator. Results indicate that the dry fog system effectively removes fine dust particles, with a removal efficiency of up to 81.9% for PM10 and 61.9% for PM2.5 after 30 minutes of operation. The dry fog, characterized by a mean size of approximately 1.5 ㎛, exhibits superior performance in comparison to traditional water spraying methods, attributed to reduced water consumption and increased contact probability between water droplets and dust particles. Furthermore, experiments with uniform-sized particles which sizes are 1 ㎛ and 2 ㎛ demonstrate the system's capability in removing ultrafine PM. The proposed submicron dry fog system shows promise for mitigating fine dust pollution in various industrial settings, offering advantages such as energy consumption and enhanced safety for workers and equipment.

Development of a dry mock-up system for verifying pyroprocess automation

  • Seungnam Yu;Dongseok Ryu;Byugsuk Park;Jonghui Han
    • Nuclear Engineering and Technology
    • /
    • v.56 no.5
    • /
    • pp.1913-1924
    • /
    • 2024
  • This paper presents the design and operation of an autonomous robot for pyroprocess automation, which requires unique approaches beyond those used in industrial applications to achieve the desired performance. Maintaining an extremely dry atmosphere is crucial to handle various materials, including chloride, and an autonomous system ensures this dry environment. The drying room dehumidifier was carefully selected and designed to generate dry air, and different types of dry air conditioning performance were evaluated, including assessing worker accessibility inside the mock-up to determine the system's feasibility. Containers used for process materials were modified to fit the gripper system of the gantry robot for automation. The loading and unloading of process materials in each equipment were automatically performed to connect the process equipment with the robotic system. The gantry robot primarily operated through macro motion to approach waypoints containing process materials, eliminating the need for precise approach motion. The robot's tapered jaw design allowed it to grasp the target object even with imperfect positioning. Robot motions were programmed using a robot simulator for initial positioning and motion planning, and real accuracy was tested in a mock-up facility using the OPC platform.

A Study of Air Pollutants Dry Deposition (대기오염물질의 건성침적에 관한 연구)

  • Lee, Chi-Young;Kang, Dong-Ku
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.3 s.49
    • /
    • pp.64-68
    • /
    • 2003
  • Measurement of dried deposition for air pollutant was investigated in Gwang-ju Health college area for a year. The average value of air pollutants was investigated three times a month. Measured heavy metals and concentration of mass are not corelated. Heavy metals were thrown up air as state of large particles and they were moved by wind. Deposition of heavy metals and deposition velocities were high in the order of Fe > n > Cu > Pb > Cr and Pb > Fe > Cr > Zn > Cu, respectively. The pattems of deposition velocity of heavy metals for a year were much the same as each other except that Pb is faster than others.

A Study on the Characteristics of Environmental Factors of Granite Dome Models with Different Material during Winter Season

  • Kong, Sung-Hoon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.1
    • /
    • pp.71-76
    • /
    • 2001
  • Factors governing the rate of heat exchange comprise temperature, air velocity, relative humidity, and relation indoors. Recently, there are many researches on the transient analysis of indoor environmental factors such as dry bulb temperature, relative humidity and air velocity in miniature models. The purpose of this study is to measure the environmental factors and to analyze and evaluate the characteristics of indoor environment in different envelop structures using granite dome models. The interior relative humidity is constant regardless of exterior humidity although a little range of variation is shown in comparison to the cement model.

  • PDF