• Title/Summary/Keyword: air-cored

Search Result 55, Processing Time 0.023 seconds

Design and Manufacture of Storage Air Heater (축열식 가열기의 설계 및 제작)

  • Lee, Yang-Ji;Kang, Sang-Hun;Park, Poo-Min;Yang, Soo-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.43-46
    • /
    • 2006
  • Storage air heater(SAH) is a general purpose facility that is used to simulate the high altitude condition of supersonic ground test facility, thurst compensation test of rocket engine nozzle and gas turbine engine combustor test. SAH in KARI is built to simulate the total temperature of the supersonic ground test facility which has a wide flight envelope from altitude 0km, Mach 2 to altitude 25km, Mach 5 and operates up to 1300K, 3.5MPa. In this paper, we introduces the SAH in JAXA which is model of SAH in KARI and summarizes the design process and manufacture of ours.

  • PDF

AC Current Sensor Using Air Core (공심코어를 사용한 교류전류 센서)

  • Park, Young-Tae;Jung, Jae-Kap
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.1
    • /
    • pp.48-52
    • /
    • 2005
  • This paper describes a current sensor for precision current measurement of an electronic watt-hour meter that is going to install in houses in the future. As the current sensor is based on an cored principle (the Rogowski principle) it is not subject to usual limitations of saturation and non-linearity of general current transformers. An advantage of the developed current sensor is that non-linearity error in low current range is improved and the construction can be kept simple using an air core. We present a magnetic field analysis of the sensor using a finite-element solver. We compared the measured values versus the calculated values.

A Study on Unsaturated Zone Characterization and Feasibility of Soil Vapor Extraction at a DNAPL-contaminated Site in Korea

  • Lee, Man Na Mi;Yeo, In Wook
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.6
    • /
    • pp.48-55
    • /
    • 2013
  • This study aimed at characterizing unsaturated zone at the source zone area contaminated by DNAPL and investigating feasibility of soil vapor extraction (SVE). Five boreholes with three multi-level screens at the depth of 3.0~4.5 m, 5.5~7.0 m, and 8.0~12.0 m were installed at the source zone. Pneumatic tests were performed to determine the permeability of porous medium. Permeability was estimated to be 81.6 to 203.7 darcy, depending on the applied solutions, which was contradicted by grain size analysis of cored soil samples leading to 3.51 darcy. This is due to air flow through gravel pack during the early stage of pneumatic test. Pressure-drawdown curve in the late stage also well showed the leaky aquifer type, indicating air leakage to the ground. Air flow tests were also carried out to investigate air flow connectivity between multi-level wells, indicating that the horizontal air flow was well developed between the lower screens of the wells, not between the upper and middle screens due to the leakage to the surface. For the SVE test, there was no noticeable variation in TCE vapor concentration between three different test runs: 1. 8 hours daily for 5 days, 2. 24 hours together with air blowing at another well (BH1), 3. five consecutive days. Even for five-day consecutive test, total amount of removed TCE was estimated only to be as low as 46.5 g.

Electromagnetic Characteristics of High-temperature Superconducting Field Coil for a 1MW class Superconducting Motor (1MW급 초전도 모터용 고온초전도 계자코일의 전자기적 특성)

  • Baik, S.K.;Sohn, M.H.;Lee, J.D.;Lee, E.Y.;Kwon, Y.K.;Moon, T.S.;Park, H.J.;Kim, Y.C.;Park, G.S.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.661-662
    • /
    • 2006
  • On the contrary of a conventional motor with very narrow air-gap, it is difficult to calculate the accurate magnetic field distribution and the performance of an air-cored superconducting motor by 2 dimensional analysis, which does not use high permeability material except outer machine shield. This paper aims to do analysis of magnetic field and force distribution from the 3 dimensional modelling of a 1MW class superconducting synchronous motor. Especially, the field coil composed of Bi-2223 high-temperature superconductor and the outer machine shield are modelled by finite element analysis software according to their structures and the self-inductance and Lorentz force are calculated based on the 3 dimensional magnetic field calculation.

  • PDF

Generation of Ultrawide Band Electromagnetic Pulse from Blumlein Pulse Forming Line

  • Jin, Yun Sik;Kim, Jong Soo;Cho, Chuhyun;Roh, Young Su
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.677-681
    • /
    • 2014
  • A high voltage pulse generator was fabricated to radiate ultrawide band electromagnetic pulse. A coaxial type of Blumlein pulse forming line is employed to produce a pulse of high voltage (>300 kV) and short pulse duration (~5 ns). A helical strip/wire type of air-cored pulse transformer was used to charge the Blumlein pulse forming line up to more than 300 kV. A peaking switch is essential to make the pulse rise time as fast as possible. Typically, the rise time is ~500 ps. The output pulse of the generator is radiated into air through an exponentially tapered TEM horn antenna. The electric field intensity of a radiated pulse was measured as a function of the distance from the transmitting horn as well as the output voltage of the peaking switch. The peak-to-peak value of the electric field intensity at 10 m from the TEM antenna was~100 kV/m.

Analysis of Electromagnetic Characteristics of a 1MW Class HTS Synchronous Motor (1MW급 고온초전도 동기기의 전자기적 특성 해석)

  • Baik, S.K.;Kwon, Y.K.;Lee, E.Y.;Lee, J.D.;Kim, Y.C.;Moon, T.S.;Park, H.J.;Kwon, W.S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.3
    • /
    • pp.32-36
    • /
    • 2007
  • On the contrary of a conventional motor with very narrow air-gap. it is difficult to calculate the accurate magnetic field distribution and the performance of an air-cored superconducting motor by 2 dimensional analysis. which does not use high permeability material except outer machine shield. This paper aims to do analysis of magnetic field and force distribution from the 3 dimensional modelling of a 1MW class superconducting synchronous motor. Especially. the field coil composed of Bi-2223 high-temperature superconductor and the outer machine shield are modelled by finite element analysis software according to their structures and the self-inductance and Lorentz force are calculated based on the 3 dimensional magnetic field calculation. Moreover. the influence of an important parameter, synchronous reactance, has been analyzed on the machine performances such as voltage variation and output power.

E.M.F Characteristic of Superconducting Synchronous Generator according to Design Parameter (설계변수 변화에 따른 초전도 동기 발전기의 유기기전력 특성)

  • Jo, Young-Sik;Hong, Jung-Pyo;Lee, Ju;Kwon, Young-Kil;Ryu, Kang-Sik
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 1999.02a
    • /
    • pp.65-68
    • /
    • 1999
  • The major deisng parameters that are considered in this paper are: 1) EMF according to width of field coil. 2) EMF according to magnetic shield length. Because of superconducting generator (SG) is actually and air cored machine with its rotor iron and stator iron teeth having been removed. In this case, the desing of the SG must be based on the 3D analysis of the magnetic field. This study presents an effective armature winding type with 3D FEM(Finite Element Method), and compares analyzed and measured results.

  • PDF

A Trial Excavation of Underwater Cultural Properties at Dongsam Site, Busan (부산 동삼지구 수중문화재 시굴조사)

  • Kim, Jin-Hoo;Kim, Hyun-Do
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.154-155
    • /
    • 2005
  • A trial excavation of underwater cultural properties at Dongsam site in Busan has been conducted. The site is located in the vicinity of Dongsam shell mound. The trial excavation consists of the shore investigation and the underwater investigation. For the shore investigation four trenches were digged. For the underwater investigation twenty boreholes were cored, and sediments at four predetermined sites were removed by air lifting technique. From the trial excavation a stump of a tree with many pieces of wood, and a few fragments of earthenwares were found. A comprehensive study of the trail excavation might furnish data for studying ancient coastal environment.

  • PDF

Modeling of Speed Controller for PM Linear Synchronous Motor (직선형 영구자석 동기 전동기의 속도 제어기 설계)

  • Jang, Seok-Myeong;You, Dae-Joon;Jang, Won-Bum;Park, Ji-Hun
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.71-73
    • /
    • 2004
  • This paper presents drive analysis of slotless air-cored PM linear synchronous motor using two-dimensional analytical method. In order to analyze dynamic characteristic, back-EMF and linkage flux are calculated by Permanent Magnet Field and also inductance are given by slotless winding coil. PMLSM drive simulation is performed by PI control system.

  • PDF

The Field Coil End Effect of HTS Synchronous Motor (고온초전도 동기모터의 계자코일 단부의 영향)

  • 백승규;권운식;손명환;이언용;권영길
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.276-279
    • /
    • 2003
  • The superconducting synchronous machine(S.S.M) including generator and motor has different electromagnetic structure from the conventional machine. With the help of superconductor having much higher operating current density than normal conductor, S.S.M can eliminate most of iron core filling inside of the conventional machine. This air-cored structure could be analysed and designed theoretically based on 2-dimensional(2-D) magnetic field distribution assuming that the windings are extended infinitely toward the axial direction. However the actual structure of S.S.M has the end regions interconnecting the straight parts of the same cross-section with the 2-D model. Therefore, this actual 3-D model has smaller field distribution than the 2-D model. In this paper, we consider the effect of the end regions on the output of a HTS model motor and suggest more accurate design approach through comparison of 2-D and 3-D magnetic field analysis.

  • PDF