• 제목/요약/키워드: air-conditioner design

검색결과 207건 처리시간 0.026초

Identification of Noise Sources in Scroll Compressor for Air-Conditioner

  • Lee, Jin-Kab
    • Journal of Mechanical Science and Technology
    • /
    • 제14권6호
    • /
    • pp.597-604
    • /
    • 2000
  • Low noise of air-conditioners is one of the most important issues because of the users' strong demand. The main source of noise in an air-conditioner is the compressor. Therefore, noise reduction in a compressor is quite significant as an element technology in the air-conditioner field. Recently, scroll compressors are widely used, because they feature low noise, due to less pulsation of gas pressure, than that of rotary compressors. For reduction of noise, the source of noise must be identified. This paper presents a detailed analysis to identify the noise source and shows the dominant factors of noise of the scroll compressor, which will make it possible to design a scroll compressor with low noise.

  • PDF

실외기 토출 유량 증대를 위한 Shroud 형상 및 휀 위치 최적 설계 (Optimization of Shroud Shape and Fan Location for Increasing Exhaust Flow Rate of Air Conditioner Outdoor Unit)

  • 유기정;김유일;이관수;차우호
    • 설비공학논문집
    • /
    • 제21권11호
    • /
    • pp.599-605
    • /
    • 2009
  • This paper presents a numerical evaluation of the flow rate of air conditioner outdoor unit by investigating the effects of fan location and shroud shape. To determine optimal design parameters, we investigated the exhaust flow rate by changing shroud height, fan height, fan guide height, and fan width. The 3rd order central composite design was performed to select three most important parameters affecting the exhaust flow rate. According to the result of response surface method, the exhaust flow rate of the optimum model increased by 6.25% compared to that of the base model.

액체 제습식 냉방 시스템의 최적 설계 (Optimization Design of Liquid Desiccant Cooling System)

  • 전동순;이상재;김선창;김영률;이창준
    • 설비공학논문집
    • /
    • 제22권7호
    • /
    • pp.419-428
    • /
    • 2010
  • This paper presents the optimization process of liquid desiccant cooling system using LiCl aqueous solution as a working fluid. Operating conditions(mass flow rate, conditioner outlet concentration, difference concentration) and design factors for heat exchangers(difference temperature of the district heating water, leaving temperature difference of the conditioner, leaving temperature difference of the regenerator, air temperature difference of the conditioner, air temperature difference of the regenerator) were optimized by response surface method. As a result, we obtained the 7.297 kW of cooling capacity and 0.788 of COP at optimized condition. Effect of difference temperature of hot water on system performances was also examined. As difference temperature of the district heating water increases, the cooling capacity increases and COP decreases.

부분구조 기반 민감도 해석을 이용한 볼트겹합 구조물의 결합강성 추정 (Identification of Connection Stiffnesses of Bolted Structures Using a Substructural Sensitvitity Analysis)

  • 서세영;방극호;김찬묵;이두호
    • 한국소음진동공학회논문집
    • /
    • 제11권7호
    • /
    • pp.287-294
    • /
    • 2001
  • The identification of connection stiffnesses of bolted structures is presented using FRT-based substructural sensitivity analysis. The substructural design sensitivity formula is derived and plugged into the optimization module of MATLAB to identify connection stiffnesses of an air-conditioner compressor or passenger Car. The air-conditioner composed of a compressor and a bracket, is analysed by using the FRT-based substructural(FBS) method to obtain FTRs an FE model is generated for the bracket, and the impact hammer test is performed for the compressor, Obtained FRTs are combined to calculate the reaction force at the connection point and the system response. By minimizing the difference between a target FRT and calculated one the connection element properties of the air-conditioner syste are identified It is shown that the proposed identification method is effective for a real problem.

  • PDF

5톤 송풍기용 FAN 인양기 구조설계 (Structural Design of CN fan Lift of 5 tonne Fans for Air Conditioner)

  • 이형욱;이광희
    • 융복합기술연구소 논문집
    • /
    • 제9권1호
    • /
    • pp.25-30
    • /
    • 2019
  • Normal cranes cannot be used to move the fan inside the high-rise factories. Due to the size of the fan and safety accidents, there is a need for a structure capable of lifting and transporting. In this study, the safety of the structure was evaluated by considering the center of gravity of the fan and the effect of the fan being tilted up. An analysis of the buckling was performed by hand calculation. Nonlinear analysis was performed using ABAQUS to evaluate the safety of the structure. The safety factor for buckling is above 4.0 and the safety factor for stress is calculated to be 1.31 under the worst load distribution conditions.

역률개선회로를 갖는 에어컨용 전력변환장치 (Air-conditioner Power Conversion Equipment with Power Factor Correction Circuit)

  • 문상필;서기영;이현우;김영문
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권5호
    • /
    • pp.345-351
    • /
    • 2000
  • To improve the current waveform of diode rectifiers, we propose a new operating principle of the voltage diode rectifiers. In the conventional voltage rectifier circuit, relatively large capacitors are used to boost the output voltage, while the proposed circuit uses ones and a small reactor not boost the output voltage but improve the input current waveform. A circuit design method is shown and confirmed simulation. It explained that compared conventional PWM(Pulse-width modulated)inverter with HPWM(Half Pulse-width modulated)inverter. Proposed HPWM inverter eliminated dead-time by lowering switching loss and holding over-shooting. Output voltage and current of this paper were applied for real air-conditioner.

  • PDF

병렬구동 방식을 이용한 인버터 에어컨용 역률제어회로 (Power Factor Correction Circuit For Inverter Air-Conditioner Using A Parallel Drive Method)

  • 정용채;정윤철;권경안
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 연구회 합동 학술발표회 논문집
    • /
    • pp.9-12
    • /
    • 1998
  • In this paper, the power factor correction circuit using a parallel drive method is proposed so that the high power inverter air-conditioner with 3[ph] compressor motor may obtain the cost down and the improved performance. The adequate design procedures are presented to reduce the material costs by eliminating the power factor improving LC filter and derating output capacitor and inverter switches. Using the determined components, the prototype circuit with 6[kW] power consumption is built and tested to verify the operation of the proposed circuit.

  • PDF

부분 스위칭 PFC 모듈을 이용한 가정용 에어컨 전원장치 (The Power System for Home Appliance Air-Conditioner using Partial Switching Power Factor Correction Module)

  • 서기영;문상필
    • 조명전기설비학회논문지
    • /
    • 제18권6호
    • /
    • pp.183-190
    • /
    • 2004
  • 본 논문은 냉난방 인버터 에어컨용 전원시스템에 역률개선 회로인 부분 스위칭 PFC 모듈을 적용하여 입력의 역률 개선 및 전류의 고조파 성분을 최소화하여 IEC555-2규정을 만족하는 입력 전원부를 설계하여 인덕터부하에 적용되는 회로 설계시의 문제점들을 해결 할 수 있는 방안들을 제시하였다. 그리고 출력전압의 상승을 억제하면서 전류파형을 개선하는 방법 및 부분 스위칭 PFC회로를 제안하여 스위칭 횟수를 적게 함으로써 압축기의 모터에 인가 할 수 있는 전압을 상승시켜 모터 적정 운전 전압을 확립하였으며, 효율이나 경제성 및 전자 노이즈 등의 문제점들을 해결하였다. 그리고 에어컨의 소비 전력을 줄일 수 있다. 이상의 결과에서 시스템 총합 운전에너지 효율이 상승되는 것을 확인하는 모든 사항은 시뮬레이션과 실험을 통하여 그 타당성을 입증했다.

ESPI를 이용한 전자부품 비파괴 신뢰성평가 (Non-destructive Reliability Evaluation of Electronic Device by ESPI)

  • 윤성운;김경석;조선형;강기수
    • 비파괴검사학회지
    • /
    • 제21권6호
    • /
    • pp.630-633
    • /
    • 2001
  • 본 연구에서는 국내에서 생산되는 에어콘용 팬의 진동해석을 위해 ESPI를 이용하였다. 기존의 진동해석 실험으로 많이 사용되는 가속도계를 에어콘용 팬에 직접 적용하는 데에는 형상의 제약 등으로 적용이 어려워 비접촉 진동해석기술을 요구하였다. 실험은 가진 장치를 이용하여 팬에 가진을 하고 ESPI를 이용하여 진동모드 및 고유주파수, 고유주파수의 범위를 검사하였다. 또한, 실험결과는 유한요소 해석과 비교되었으며, 실험결과로부터 실제 팬의 사용 회전수에서 제품의 신뢰성을 평가하였다 본 연구에서 사용된 ESPI는 품질개선을 위한 재질변화 또는 형상변화 시 설계측면에서 효과적인 설계정보를 제공할 수 있으며, 기존의 진동해석 기술의 단점을 보완할 수 있으리라 사료된다.

  • PDF