• 제목/요약/키워드: air-breakdown

검색결과 236건 처리시간 0.036초

수직배치 구대평판 공기 갭에서 연소화염 존재시의 절연파괴 특성 (Breakdown Characteristics of a Vertical Sphere-Plane Air Gap in the Presence of Combustion Flame)

  • 김인식
    • 조명전기설비학회논문지
    • /
    • 제25권5호
    • /
    • pp.79-84
    • /
    • 2011
  • In this study, breakdown characteristics of a vertical sphere-plane air gap in the presence of combustion flame were examined under the application of a.c. and d.c. high-voltages in order to investigate the effect of flame on the dielectric strength of air. Propane gas is used as the fuel of the flame, and the temperature distribution of air around the flame is measured. The polarity effects for the d.c. voltages and breakdown voltages of air when applied both of a.c. and d.c. voltages were examined in the case of the variation of the gap length and the horizontal distance between the flame and the high-voltage sphere electrode. The influence of relative air density, electrification and shape changes of the flame as factors that affect the breakdown voltages were discussed.

Dry-Air의 습도에 따른 절연파괴 특성 (The Breakdown Characteristics for Dry-Air with Humidity Variations)

  • 박혜리;김영수;최은혁;박광서;김이국;박원주;이광식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.238-240
    • /
    • 2008
  • This paper gives a basic data of the breakdown characteristics of Dry-Air and air based on their dew point and humidity variations in experimental GIS model by applying AC voltage. The breakdown voltage of Dry-Air was increased as gap length had been increased. The characteristics of Dry-air which had low dew point were higher. In the case of air, the breakdown voltage curves were like Dry-Air' s. But the curves were slightly folded up and down because of impurities.

  • PDF

362 kV GIB 내에서 건조공기의 절연파괴 특성 (Breakdown Characteristics of Dry Air under 362 kV GIB)

  • 한기선;주형준;윤진열;유홍근
    • 한국전기전자재료학회논문지
    • /
    • 제23권10호
    • /
    • pp.804-808
    • /
    • 2010
  • In this paper, we studied the dielectric breakdown voltage characteristics by the AC withstand voltage test on using green insulation dry air instead of $SF_6$ insulation gas used in the GIB (gas insulated bus) of 362 kV GIS (gas insulated switchgear). The AC withstand voltage test applied to the standard KEPCO's 362 kV GIB with dry air insulation, and the equivalence of dielectric breakdown voltage for dry air and $SF_6$ gas were examined, and the empirical formulas of dielectric breakdown voltage for dry air were calculated, and the criterion of AC withstand voltage test for dry air insulation was derived. Using the criterion, dry air can be used instead of $SF_6$ gas for 362 kV GIB in the factory acceptance test was confirmed.

평등/불평등 전계하에서 제조공기(I-Air)와 $SF_6$에 대한 압력별 절연파괴특성 (Breakdown Characteristics for Imitation Air and $SF_6$ with Pressure Variation under Uniform and Non-Uniform Field)

  • 이창욱;이창훈;최은혁;장승호;이광식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 추계학술대회 논문집
    • /
    • pp.259-262
    • /
    • 2007
  • In this paper approves AC high voltage by experimental GIS(Gas Insulated Switchgear) chamber and AC 300[kV] power source to study breakdown characteristics by pressure(P) change and change of electrode distance(d) at AC high voltage of Imitation Air(I-Air, $N_2$ : $O_2$ = 79(%) : 21[%]) to alternate $SF_6$ and achieved research. Gave P change of I-Air to study I-Air's breakdown characteristics using uniform(Sphere-Sphere electrode) and non-uniform fields(Needle-Plane electrode) and studied relations breakdown voltage($V_B$) by each P different d.

  • PDF

불평등 전계하의 제조공기(I-Air)에 대한 절연파괴 특성 (Breakdown Characteristics of Imitation Air under Non-Uniform Fields)

  • 이창욱;이창훈;최은혁;윤대희;장승호;김정배;박원주;이광식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.385-388
    • /
    • 2007
  • In this paper approves AC high voltage by experimental GIS(Gas Insulated Switchgear) chamber and AC 300[kV] power source to study breakdown characteristics by pressure(P) change and change of electrode distance(d) at AC high voltage of Imitation Air(I-Air, $N_2$ : $O_2$ = 79[%] : 21[%]) to alternate $SF_6$ and achieved research. Gave P change of I-Air to study I-Air's breakdown characteristics using non-uniform fields(Needle--Plane electrode) and studied relations breakdown voltage ($V_B$) by each P different d.

  • PDF

온도변화에 따른 $SF_6$와 I-Air의 절연파괴특성 비교 (A Comparision of the Breakdown Characteristics for $SF_6$ and I-Air based on Temperature variations)

  • 박혜리;김도석;이상호;우성훈;이광식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.235-237
    • /
    • 2008
  • This paper gives a basic data of the breakdown characteristics of l-Air(Imitation Air, $N_2:O_2=79:21$) and $SF_6$ gas based on temperature variations in experimental GIS model by applying negative DC voltage. The breakdown charcteristics were compared with gas pressures and each gas already entered in GIS model. The characteristics of l-Air and $SF_6$ were different in specific temperature range that $SF_6$ gas was being liquefied. The breakdown voltages of $SF_6$ were more higher than l-Air except for 4[atm] at $-10{\sim}0[^{\circ}C]$.

  • PDF

평등/불평등 전계 하에서의 제조공기(I-Air) 절연파괴특성 (Breakdown Characteristics of Imitation Air under Uniform Fields and Non-Uniform)

  • 이창욱;이창훈;최은혁;김정배;이광식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1424-1425
    • /
    • 2007
  • In this paper approves AC high voltage by experimental GIS(Gas Insulated Switchgear) chamber and AC 300[kV] power source to study breakdown characteristics by pressure(P) change and change of electrode distance(d) at AC high voltage of Imitation Air(I-Air, $N_2$ : $O_2$ = 79[%] : 21[%]) to alternate $SF_6$ and achieved research. Gave P change of I-Air to study I-Air's breakdown characteristics using niform fields(Sphere-Sphere electrode) and non-uniform fields(Needle-Plane electrode) and studied relations breakdown voltage ($V_B$) by each P different d.

  • PDF

공기중 절연파괴에 있어서 전극표면의 요철에 의한 영향 (The Effect of Surface Roughness on Breakdown in Air)

  • 오철한;김미태
    • 전기의세계
    • /
    • 제28권11호
    • /
    • pp.33-36
    • /
    • 1979
  • In a uniform field, when an electrode with a hemispherical protrusion is set in atmosphere, by applying the streamer breakdown criterion and the surface roughness factor, the effect of field distortion due to electrode surface roughness on breakdown is investigated theoretically. A quantitative relation between the threshold of breakdown and the air pressure times the heigh of protrusion is derived by the aid of a computor and the results are compared with that of SF$_{6}$./.

  • PDF

Lightning Impulse Breakdown Characteristic of Dry-Air/Silicone Rubber Hybrid Insulation in Rod-Plane Electrode

  • Kwon, Jung-Hun;Seo, Cheong-Won;Kim, Yu-Min;Lim, Kee-Joe
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1181-1187
    • /
    • 2015
  • Sulfur hexafluoride (SF6) gas is used widely in electric power equipment such as Gas Insulated Switchgear (GIS), Gas Insulation transmission Line (GIL), and Gas Circuit Breaker (GCB). But applications of SF6 should be restricted because SF6 gas is one of the greenhouse effect gases. To reduce use of SF6 gas, a study on eco-friendly alternative insulation medium is needed. In this paper, we investigated lightning impulse (LI) breakdown of dry-air which is attracting attention as an ecofriendly alternative gas and the LI breakdown of hybrid insulation combined with dry-air and solid insulation (Room-Temperature Vulcanizing Silicone Rubber-RTV SIR) and dry-air in inhomogeneous fields according to gap distance and pressure. The experiment results showed that the LI breakdown strength of hybrid insulation system was higher than that of dry-air insulation system. It was verified that the development of technology related to eco-friendly power apparatus compact such GIS, GCB and GIL can be used as basic research data.

Breakdown characteristics of SF6 and Imitation Air in Temperature Decline

  • Lim, Chang-Ho;Choi, Eun-Hyeok;Kim, Do-Seok;Kim, Young-Su;Park, Won-Zoo;Lee, Kwang-Sik
    • 조명전기설비학회논문지
    • /
    • 제21권4호
    • /
    • pp.115-121
    • /
    • 2007
  • This paper describes experiments of the breakdown characteristics by temperature change of $SF_6$ gas and Imitation Air(I-Air) in model GIS(Gas Insulated Switchgear). From the results of the experiments, the breakdown characteristics classify the vapor stage of $SF_6$ according to Paschen's law, in which the stage of coexistence for gas & liquid of the voltage value increases. This results in large deviation and the breakdown of the voltage(VB) low stage as the interior of the chamber is filled with a mixture of $SF_6$ that is not liquefacted and remaining air that can not be ventilated. The ability of $SF_6$ liquid($LSF_6$) insulation is higher than high-pressurize $SF_6$ gas. The VB of the I-Air decreases as the temperature drops and the VB also drops. It is considered that the results of this paper are fundamental data for the electric insulation design of superconductor and cryogenic equipment that will be studied and developed in the future.