• 제목/요약/키워드: air voids

검색결과 105건 처리시간 0.022초

입상의 이산화티타늄 박막을 이용한 수소센서 (Granular Thin Film of Titanium Dioxide for Hydrogen Gas Sensor)

  • 송혜진;오동훈;정진연;웬득화;조유석;김도진
    • 한국재료학회지
    • /
    • 제19권6호
    • /
    • pp.325-329
    • /
    • 2009
  • Titanium dioxide thin films were fabricated as hydrogen sensors and its sensing properties were tested. The titanium was deposited on a $SiO_2$/Si substrate by the DC magnetron sputtering method and was oxidized at an optimized temperature of $850^{\circ}C$ in air. The titanium film originally had smooth surface morphology, but the film agglomerated to nano-size grains when the temperature reached oxidation temperature where it formed titanium oxide with a rutile structure. The oxide thin film formed by grains of tens of nanometers size also showed many short cracks and voids between the grains. The response to 1% hydrogen gas was ${\sim}2{\times}10^6$ at the optimum sensing temperature of $200^{\circ}C$, and ${\sim}10^3$ at room temperature. This extremely high sensitivity of the thin film to hydrogen was due partly to the porous structure of the nano-sized sensing particles. Other sensor properties were also examined.

중층형 생활한옥 모델시안 연구 - 청주 서운동의 사례를 중심으로 - (The Tentative Plans of Middle-rise Traditional Houses (Han-ok) Located on Seoun-dong in Urban Area of Cheongju, Korea)

  • 김찬구;김태영
    • 한국농촌건축학회논문집
    • /
    • 제24권2호
    • /
    • pp.21-28
    • /
    • 2022
  • Focusing on the creation of a new han ok, especially a mid-rise hybrid-structured Han-ok, this study proposes a middle-rise (four-story) Han-ok on one and two lots located in Seoun-dong, the existing Han-ok intensive housing site in downtown Cheongju. 1) In terms of layout and function, according to the existing L-shaped Han-ok corresponding to the road and the direction, the parking lots and shops on the 1st floor, the business facility on the 2nd floor, the Han-ok on the 3rd and 4th floors are placed. There are yards, open roof yards, and semi-open Daecheong(大廳, main hall), which can be shared by residents. 2) In terms of structure and form, one or two floors (some 3 floors) are 5.4m square and 5.4×6.6m modules of the RC(Reinforced Concrete) group, and the upper floor reflects the 2.7m module, size and shape of the existing Han-ok. By extending the outer wall of the RC group in the lower floors (1st to 3rd floors) to the wooden exterior of the upper floors (2nd to 4th floors), it is attempted to avoid the awkward appearance of the RC group being exposed to wooden structures. And it is also attempted to reflect the wooden shape and design elements through the elevation elements such as horizontal windows, corner windows, picture frames, and vertical slits. 3) In environmental control and facilities, it is attempted to smooth the ventilation of the building by forming a vertical upward airflow from the dark space of the low floor to the positive of the upper floor. This doubles the effect through a vertical rise of cold air generated in a narrow alleyway, piloti parking lot, and the various voids. In addition to the Daecheong and Numaru(loft) of Han ok, the rooftop yard, the terrace, and the balcony, horizontal natural ventilation is generated through divided doors and transom windows.

재생 이산화티탄을 혼입한 모르타르의 NOx 저감률 민감도 분석 (Sensitivity of NOx Removal on Recycled TiO2 in Cement Mortar)

  • 이인규;김진희;김종호;노영숙
    • 한국건설순환자원학회논문집
    • /
    • 제4권4호
    • /
    • pp.388-395
    • /
    • 2016
  • 본 논문에서는 폐수슬러지에서 제조된 재활용 이산화티탄($TiO_2$)을 혼입한 시멘트 모르타르의 NOx 저감 성능에 대해 고찰하였다. 일반적으로, 이산화티탄은 클러스터 형태로 입자가 붙어 있어, 시멘트의 응결과 경화 전에 타설체 하면에 침강하는 특징이 있다. 그 결과로 타설체의 상면과 하면에는 이산화티탄의 분포도가 서로 상당한 차이를 나타내고, 광촉매 효과도 하면에서 우수하게 나타난다. 건물이나 주택과 같은 건축구조물에서는 이를 해결하기 위해, 이산화티탄을 혼입한 프리캐스트 제품을 미리 제작 후, 조립 시에는 타설 시 상면과 하면을 뒤집어 거치하여 상대적으로 높은 이산화티탄 분포면을 대기에 노출시키는 방식을 사용한다. 그러나 콘크리트 도로포장과 같은 현장 타설의 경우, 상면과 하면을 뒤집어 거치할 수 없기 때문에 이산화티탄의 분산성은 중요하다. 이를 개선시키기 위한 본 논문의 결과로 실리카퓸, 고성능감수제, 증점제, 고로슬래그 등 전형적인 시멘트성 재료의 분산에 기여하는 재료는 이산화티탄 클러스터의 분산효과에 미미한 영향을 주었다. 급결제, 발포제, 작은 크기의 잔골재의 조합이 이산화티탄 클러스터의 분산성을 개선하였다. 분산성 개선에도 불구하고, 타설체 상면과 하면의 NOx 제거효율은 하면에 큰 효율을 지속적으로 나타내었고, 이는 표면에 분포하는 공극량에 따라 달라지는 것을 디지털 표면 이미지 분석을 통하여 확인하였다. 많은 공극분포를 갖는 표면은 상대적으로 매끄러운 표면에 비해 NO가스 흡착을 기본적으로 높이게 되고, 이를 기준으로 상대적인 NOx 제거효율이 높아지는 것으로 사료된다.

프리믹스 시멘트의 활용성 분석을 위한 결합재의 혼합방법에 따른 고장도 콘크리트의 물성 분석 (Physical Analysis of High Strength Concrete According to Mixing Methods of Binders for Application Analysis of Pre-Mix Cement)

  • 한천구;이해일
    • 한국건축시공학회지
    • /
    • 제9권5호
    • /
    • pp.127-133
    • /
    • 2009
  • 일반적으로 콘크리트를 고강도화 하기 위해서는 결합재의 강도를 증가시키는 것이 중요하다. 그러나 고강도 콘크리트에 사용되는 광물질 혼화재들이 가진 고결현상으로 인해 개별투입 혼합 시에는 분산성이 크게 저하되어 유동성을 저감시키고, 충분한 강도를 발휘하지 못하는 문제가 발생한다. 이러한 문제를 해결하기 위해 각각의 결합재를 사전에 프리믹스하여 콘크리트를 제조하게 되면 광물질 혼화재가 충분히 결합재 중에 분산되어 콘크리트의 유동성 향상 및 강도증진 등에 기여할 수 있을 것으로 기대된다. 따라서 본 연구에서는 W/B $15{\sim}35%$ 범위내에서 프리믹스 시멘트의 효과를 분석하기 위해 결합재의 혼합방법에 따른 고강도 콘크리트의 물성을 분석하였다. 그 결과 유동성은 프리믹스의 균일분산 및 볼 베어링 효과로 인해 개별혼합보다 양호한 결과를 나타내었고, 공기량은 프리믹스의 시멘트 입자간 공극을 실리카퓸의 미세한 입자가 충전하는 마이크로 필러 효과로 인해 개별혼합 보다 약간 감소하였으며, 응결시간은 프리믹스의 균질한 분산이 수화발열속도에 영향을 주어 개별혼합보다 단축되었다. 압축강도는 프리믹스의 공극구조 치밀화로 인하여 증가하였으며, 강도편차 또한 평균적으로 약 1.69 % 정도 변동계수가 감소하는 효과를 나타내었다.

고감성 의류용 복합사 직물의 수분증기 및 열이동 특성 -실험방법에 따른 수분증기 및 열이동- (Water Vapor and Thermal Transmission Properties of Hybrid Yarns Fabrics for High Emotional Garments -Water Vapor and Heat Transport according to Experimental-Method-)

  • 김승진;김현아
    • 한국의류학회지
    • /
    • 제41권1호
    • /
    • pp.84-97
    • /
    • 2017
  • Water vapor and thermal transmission properties of high emotional garments are important to evaluate wear comfort; in addition, the measuring methods of these properties are also critical for breathable and warm suit fabrics. In this study, the water vapor and thermal properties of composite yarn fabrics made of CoolMax, Tencel, and Bamboo fibers with filaments were measured and compared according to the measuring method. Water Vapor Transmittance (WVT) of the fabric woven by the sheath/core composite yarn in the warp direction was the highest due to the small staple fiber volume in the sheath/core yarn structure and high air voids in the sheath/core yarn fabrics. This property was also the highest in fabrics woven by bamboo staple yarns in the weft direction, and was the lowest on hi-multi filament fabrics. However, water vapor resistance ($R_{ef}$) of these fabrics by KSK ISO 11092 showed the opposite results to the water vapor transmittance method ($CaCl_2$ method); in addition, its correlation coefficient was low. The correlation coefficient between $R_{ef}$ and the drying rate was 0.719; therefore, the measurement mechanism of $R_{ef}$ is analogous to the drying property measurement. The thermal conductivity of the fabrics woven with compact staple yarn showed a high value; however, the hi-multi filament fabric showed low thermal conductivity. Therefore, fiber characteristics affect thermal properties more than yarn structure. The correlation between thermal property and moisture transport was also low. This study showed that: water vapor transmittance was active at the loose yarn structure, dry heat transport was vigorous at the compact yarn structure, and heat transport was affected more by fiber characteristics than yarn structure. In conclusion, sheath/core composite yarns were relevant to the high absorptive cool suit along with siro-fil and CoolMax/Bamboo staple yarns that were relevant to the heat diffusive cool suit.

혼화제 종류별로 제조된 콘크리트의 재 혼합 타설시 특성 분석 (Analysis of the Characteristics of Manufactured Concrete, according to the Type of Admixture used when Remixing and Placing it)

  • 류현기;신상용
    • 한국건축시공학회지
    • /
    • 제10권5호
    • /
    • pp.95-102
    • /
    • 2010
  • 최근 들어 경제성장과 산업기반 시설의 확충 등으로 인하여 타사의 레미콘을 종종 혼용 하는 경우가 있는데, 사용되는 혼화재료의 경우 제조회사별로 화학성분 및 첨가량의 차이가 있으므로 서로 다른 레미콘 제조회사의 콘크리트가 혼합되었을 시에 강도 저하 및 응결지연, 내구성 저하 등으로 인한 콘크리트의 성능 저하요인이 발생된다. 혼화제 종류별로 제조된 콘크리트의 재 혼합 타설시의 성능 분석을 한 결과로서 먼저 슬럼프는 모든 콘크리트에서 목표슬럼프 값을 만족하였으며, 공기량 역시 모든 콘크리트에서 목표 공기량을 만족 하였다. 블리딩량 및 블리딩률의 경우 전반적으로 유기산계와 같이 혼합된 콘크리트에서 높은 블리딩량을 나타내었다. 조기재령의 압축강도는 Plain의 나프탈린계에서 가장 큰 강도발현 경향을 나타내었고, 재 혼합 콘크리트에서는 5:5의 유기산계와 나프탈린계에서 가장 큰 압축 강도 발현 경향을 나타내었다. 표준재령의 경우 5:5의 재 혼합 콘크리트 중 나프탈린계+리그닌계를 혼합하였을 때 가장 큰 강도 발현 경향을 나타내었다. 인장강도 역시 압축강도와 유사한 경향을 나타내었다. 길이변화율은 전반적으로 Plain에 비하여 큰 건조수축 경향을 나타내었으며, 재 혼합콘크리트 7:3의 경우에 가장 큰 건조수축경향을 나타내었다. SEM사진 분석결과 재혼합 콘크리트에서 더 많은 미세공극들이 발견되었다. 결과적으로 한 종류의 레미콘을 이용하여 타설하였을 경우 보다 혼합사용 하였을 경우 응결지연 및 초기강도 저하현상이 나타나고, 더 큰 건조 수축 경향을 나타내어 일부 혼화제를 선별하여 혼합 사용하는 경우를 제외하고는 가능한 동일한 혼화제를 사용해야 할 것으로 판단된다.

연마판의 거칠기에 따르는 SiC 세라믹스의 굽힘강도 특성 (Bending Strength Properties of SiC Ceramics at Different Roughness Values of Polishing Plates)

  • 남기우;김은선
    • 대한기계학회논문집A
    • /
    • 제35권7호
    • /
    • pp.779-784
    • /
    • 2011
  • 본 논문은 첨가제 $SiO_2$를 가지는 3종류의 SiC 세라믹스의 연마판 거칠기에 따르는 균열 치유 연구를 실시하였다. 혼합물은 질소가스 분위기에서 2053 K, 35 MPa, 1시간 동안 소결하였다. SiC 세라믹스 시험편의 최적 균열 치유 조건은 1373 K에서 1시간이다. 균열부의 치유 물질은 SiC와 $O_2$의 산화반응에 의한 유리상 $SiO_2$이다. 최적 치유 조건에서 미연마 SiC 세라믹스의 굽힘 강도는 완전하게 회복되지 않았다. 그러나 SAY, SAYS-1 및 SAYS-2 시험편에서 경제적인 면을 고려하면 1시간 열처리에서 상온 굽힘 강도가 가장 높게 나타난 SAY 시험편이 우수하다. $125\;{\mu}m$ 연마판의 연마 시험편은 결함의 수나 크기가 줄어들었으나, 열처리 후에도 표면 미세 결함이 완전하게 치유되지 못하였다. $40\;{\mu}m$ 연마판의 연마 시험편은 1시간 열처리 후 표면 결함이나 기공은 거의 없었으며, 굽힘 강도는 $6\;{\mu}m$ 연마판 경면 시험편의 강도만큼 회복하였다.

나노합성 무기질 폴리머계 표면처리제가 콘크리트의 내구성에 미치는 영향 (The Influence of Nano Synthesized Polymer Paint on Durability of Concrete)

  • 백종명;박용걸
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제20권1호
    • /
    • pp.56-63
    • /
    • 2016
  • 콘크리트 구조물의 내구성을 향상하기 위해 개발된 통기성이 개선된 나노합성 폴리머 표면처리제를 도포한 콘크리트의 내구성향상 효과를 평가하기 위해 내부 구조와 공극량을 측정하였으며, 염분침투, 탄산화, 동결융해 및 화학적 침식 저항성에 대한 실험을 진행하여 기존 표면처리제와 비교 분석하였다. 공극량과 내부 구조를 측정한 결과, 나노합성 폴리머 표면처리제를 도포한 콘크리트는 $0.3{\mu}m$ 이상의 공극과 $0.1{\mu}m$ 이하의 공극영역에서 세공량이 감소하는 경향을 보였으며, 전자현미경을 통한 촬영된 내부는 수화조직에 의해 치밀함을 보였다. 나노합성 폴리머 표면처리제를 도포한 콘크리트의 염분침투 깊이는 무도포 콘크리트에 비해 약 92% 이상, 수성 에폭시 표면처리제를 도포한 콘크리트보다도 약 70% 이상 감소하였다. 이는 탄산화, 동결융해 및 화학적 침식 저항성 실험에서도 비슷하게 나타났다. 특히 황산 5% 수용액에 침지 실험한 화학적 침식 저항성 실험에서는 침지 12일 이후 무도포 콘크리트와 수성 에폭시 표면처리제를 도포한 콘크리트에서 -4%의 중량감소를 보였지만, 나노합성 폴리머 표면처리제를 도포한 콘크리트는 -1.7%의 중량감소율을 보였으며, Tsivilis et al.에 의한 외관등급 조사법에서도 우수한 결과를 보였다.

마이크로기포제를 사용한 콘크리트의 열적 특성에 관한 연구 (Study on the Thermal Characteristics of Concrete Using Micro Form Admixture)

  • 박영신;김정호;전현규;서치호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권2호
    • /
    • pp.101-109
    • /
    • 2013
  • 최근 전세계는 급격한 기후조건과 환경변화에 의해 냉난방 에너지 사용이 증가되고 있으며 이는 화석 연료 사용량 증가와 함께 $CO_2$ 배출량 상승, 지구 온난화 등 환경과 에너지에 대한 수많은 문제를 유발하고 있어 세계 각국은 온실가스 배출 및 에너지 소비 감소를 위한 대응책을 마련하고 있다. 우리나라 또한 정부의 '저탄소 녹색 성장' 및 '친환경 주택 건설기준 및 성능' 등의 정책을 선포하는 등 건물 부분에 있어 환경과 에너지 관리에 대한 노력을 하고 있다. 우리나라의 총 에너지 소비량 중 건물 부문이 차지하는 비율은 약 25%에 달하며 다른 산업 분야에 비해 연간 에너지 소비 증가율이 높은 편이다. 건물에서 에너지 손실이 가장 큰 부위는 외피로서, 이 부분의 에너지 손실을 감소하기 위한 연구가 활발히 진행되고 있으나 이는 대부분 창호 및 단열재를 사용한 연구이며 건물 외피의 70% 이상을 차지하고 있는 콘크리트에 대한 연구는 미미한 실정이다. 따라서 건물의 에너지 손실을 최소화하기 위해서는 콘크리트 자체에서 단열성능을 확보할 수 있어야 하며 이에 대한 연구가 필요하다. 따라서 본 연구는 콘크리트의 단열성능을 확보하면서 구조용으로 사용이 가능한 콘크리트를 개발하기 위한 실험을 진행하였다. Test 1의 실험결과로써, Micro Foam Admixture (MFA)를 사용한 콘크리트는 슬럼프 경시변화가 개선되었으며, MFA의 혼입율을 증가할 경우 압축강도는 감소되고 열전도율은 증가되는 결과를 나타내었다. Test 2의 실험결과에서는 물시멘트비 변화시 물시멘트비 증가에 따라 압축강도는 감소하였고 열전도율은 증가하였다. 그러나 잔골재율 변화에 대한 물성 및 열적 특성은 큰 차이를 나타내지 않았다.

환경친화 옹벽용 포러스콘크리트의 현장적용성에 관한 연구Ⅱ (A Study on the Filed application of Environmental Friendly Porous Concrete For Retaining Wall)

  • 김정환;이남익;이준;박승범;장영일;서대석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.817-820
    • /
    • 2008
  • 본 연구는 투수, 다기능, 수질정화, 흡음성을 가진 포러스 콘크리트를 하천의 제방공사, 농업수로의 제방공사, 도로 법면의 사방공사, 철도의 측방사면공사, 조경담장, 도로 방호벽, 어소블록 등을 구축하도록 하는 옹벽블록을 장투리천에 적용시켰으며 그 결과는 다음과 같다. 포러스 콘크리트 옹벽블록의 시공은 기초터파기, 잡석부설 및 다짐, 기초콘크리트, 부착모르타르 부설, 블록쌓기, 뒷채움 잡석 부설 및 다짐, 블록연결핀으로 연결 등의 순서로 진행되었으며 공종별로 그 특성에 맞는 재료를 선정하여 시공하였다.현장에 적용된 포러스콘크리트 옹벽블록의 품질 특성 평가 결과, 압축강도는 $20.1{\sim}22.5MPa$, 공극률은 $10.0{\sim}10.4$%로 측정되어 시방서에 명기되어 있는 압축강도 18MPa이상, 공극률 10%이상을 모두 만족시키는 것으로 나타났다. Slope/w를 이용하여 포러스콘크리트 옹벽블록의 사면 안정성 검토결과 안전율이 1.739으로 해석되어 설계 기준 안전률인 1.3을 초과하여 안전한 것으로 나타났다. 시공 6개월 후 식생 모니터링 결과, 갯버들이 식재된 식재공에서 양호하게 성장하여 포러콘크리트옹벽블록은 이 치수위주의 하천정비나 불량한 유역관리에 의해 훼손된 하천의 생태서식처를 되살리고 하도와 하천변을 원래의 자연하천에 가깝게 되돌리는 데 유효한 공법으로 판단된다.

  • PDF