• Title/Summary/Keyword: air void

Search Result 264, Processing Time 0.022 seconds

A Study on the Sound Absorption Properties of Cellular Concrete with Continuous voids (연속공극을 갖는 기포콘크리트의 흡음특성에 관한 연구)

  • Lee, Seung-Han;Jung, Yong-Wook;Park, Jung-Jun
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.4
    • /
    • pp.566-573
    • /
    • 2003
  • This study was performed to manufacture a rigid sound absorbing material by increasing the continuous void ratio of cellular concrete, thereby achieving an increase in sound absorption ratio and an enhancement in strength of the cellular concrete. By the experiments, it was determined that an increase in sound absorption ratio is achieved by increasing the added amount of air voids, thereby increasing the continuous void ratio. When the material had a thickness of 5 cm, a satisfactory average sound absorption ratio of 70% was obtained at a continuous void ratio of 40% or more. An increase in the thickness of the sound absorbing material resulted in an increase in sound absorption ratio in a super bass range. The specific gravity of cellular concrete meeting an average sound absorption ratio of 70% was 0.4 at a material thickness of 5 cm, and 0.6 or less at a material thickness of 7 cm. The compressive strength of the cellular concrete having a specific gravity of 0.4 meeting an average sound absorption ratio of 70% or more was 1.37 Mpa at a cement fineness of 3,000. This compressive strength was increased to 3.34 MPa at a cement fineness of 8,000. Accordingly, it was determined that the compressive strength of cellular concrete having continuous voids increases with a higher cement fineness.

Void Ratio Evaluation of Unsaturated Soils by Compressional and Shear Waves (압축파와 전단파를 이용한 불포화토의 간극비 산정)

  • Byun, Yong-Hoon;Cho, Se-Hyun;Yoon, Hyung-Koo;Choo, Yun-Wook;Kim, Dong-Su;Lee, Jong-Sub
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.12
    • /
    • pp.41-51
    • /
    • 2012
  • Soils are commonly unsaturated in the near surface. The stiffness of soils is affected by the amount of air and water. The objective of this study is to evaluate the porosity of the unsaturated soils by using the elastic waves including compressional and shear waves. The elastic waves are measured at different degrees of saturation by controlling the matric suction. Thus, the unsaturated soils are characterized at different levels of the matric suction. Shear and compressional waves are measured by using the bender elements and the piezo disk elements, respectively. Both transducers are installed on the walls of the rectangular cell. The unsaturated soils are prepared by using uniform size sands and silts. Test results show that both compressional and shear wave velocities change according to the matric suction. The elastic modulus, the shear modulus, and the Poisson's ratio are estimated based on the measured elastic wave velocities. In addition, the void ratio of the unsaturated soils estimated using elastic wave velocities matches well with the volume based void ratio. This study demonstrates that the elastic waves can be effectively used for the characterization of unsaturated soils.

Effects of the Compaction and Size of Bottom Ash Aggregate on Thermal Conductivity of Porous Concrete (가압다짐과 바텀애시 골재 크기 특성이 다공성 콘크리트의 열전도도에 미치는 영향)

  • Yang, In-Hwan;Jeong, Seung-Tae;Park, Ji-Hun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.3
    • /
    • pp.195-203
    • /
    • 2022
  • In this paper, the effects of the bottom ash aggregate sizes and compaction levels on the thermal conductivity of porous concrete were investigated. In this experimental study, bottom ash was used as aggregates after identifying the aggregate characteristics. SA mixtures included hybrid aggregates, and DA contained only one particle size. The water-binder ratio was fixed at 0.30, and the compaction levels were applied to the concrete specimens at 0.5, 1.5, and 3.0 MPa. Unit weight, total void ratio, and thermal conductivity were measured and analyzed. As the compaction level increased, the unit weight and thermal conductivity increased in the SA mixtures, but the total void ratio decreased. In addition, the thermal conductivity of the specimens under oven-dried condition were lower than that of the specimens under air-dried condition. The correlation between the unit weight, total porosity, and thermal conductivity of porous concrete was analyzed. The thermal conductivity-unit weight correlation was proportional, while the thermal conductivity-total void ratio correlation was inversely proportional.

Three-Dimensional Numerical Simulation of Mold-Filing and Void Formation During Vacuum-Assisted Resin Transfer Molding (VARTM 공정에서의 금형 충전 및 기공 형성에 관한 3차원 수치해석)

  • 강문구;배준호;이우일
    • Composites Research
    • /
    • v.17 no.3
    • /
    • pp.1-7
    • /
    • 2004
  • In the vacuum assisted RTM (VARTM) process that has become the center of attention for manufacturing massive composite structures, a good evacuation of air in the fiber preform is recognized as the prime factor. The microvoids, or the dry spots, are formed as a result of improper gate/vent locations and the mold geometry. The non-uniform resin velocity at the flow front leads to the formation of microvoids in the fibers, whereas the air in the microvoids can migrate along with the resin flow during mold filling. The residual air in the internal voids of a composite structure may cause a degradation of the mechanical properties as well as the structural failure. In this study, a unified macro- and micro analysis methods were developed to investigate the formation and transport of air in resin during VARTM process. A numerical simulation program was developed to analyze the three-dimensional flow pattern as well as the macro- and microscopic distribution of air in a composite part fabricated by VARTM process.

Uniformity of Large Gypsum-cemented Specimens Fabricated by Air Pluviation Method (낙사법으로 조성된 대형 석고 고결시료의 균질성)

  • Lee, Moon-Joo;Choi, Sung-Kun;Choo, Hyun-Wook;Cho, Yong-Soon;Lee, Woo-Jin
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.1
    • /
    • pp.91-99
    • /
    • 2008
  • The method to prepare the large cemented sand specimen for calibration chamber test by air-pluviation is investigated in this study. The uniformity of cemented specimen is evaluated by performing the CPTs, DMTs, and bender element tests in the calibration chamber. The sand particles, pre-wetted with 0.5% water content, are mixed with gypsum to provide the homogeneous coating of gypsum particles on the grain surface. It was shown that the pre-wetting of particle surface is effective to minimize the potential for segregation between sands and gypsum during air-pluviation. It was observed that the extreme void ratios ($e_{max}\;and\;e_{mix}$) of the mixture of pre-wetted sand and gypsum powder increase at lower gypsum content while those of the mixture of dry sand and gypsum decrease with increasing gypsum content. It was also shown from the test results that large cemented specimens reconstituted in calibration chamber by rainer system are quite uniform in vertical and horizontal directions.

A Study on the Characteristics of the Super High-Rise Housing Complex in Hong Kong (홍콩 초고층 주거단지의 특징에 관한 연구)

  • Kim Sung-Hwa;Lee Jae-Hoon
    • Journal of the Korean housing association
    • /
    • v.16 no.4
    • /
    • pp.37-44
    • /
    • 2005
  • The purpose of this study is to analyze the typological characteristics of super high-rise housings in Hong Kong. The results are as follows; 1) Most of the plan types of the residential building in Hong Kong are tower types and they show lots of curves on the external resident blocks so that each resident families can face maximum open air. 2) Each residential unit is arranged symmetrically and systematically around the central core. 3) The most of core types are central core types which are usually planned to place void light well to improve lighting and ventilation. 4) Rooms are arranged in line from entrance to kitchen, to living & dinning room, and finally bedroom and bathroom. Dinning area is arranged together with living area. 5) At least, more than two sides of the each unit were facing the open air; one side is for the view from a bedroom or a livingroom, the other side is for the ventilation of a kitchen or a bathroom.

A Study on the Typological Characteristics of the Super High-Rise Housings in Hong Kong (홍콩 초고층 주거의 평면적 특징에 관한 연구)

  • Kim, Sung-Hwa;Lee, Jae-Hoon
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2004.11a
    • /
    • pp.43-48
    • /
    • 2004
  • The purpose of this study is to analyze the typological characteristics of super high-rise housings in Hong Kong. The results are as follows; 1) The Plan types of the residential building in Hong Kong are mostly tower types and they show lots of curves on the external resident blocks so each resident families can face maximum open air. 2)Household arrangements or resident families form are shown as symmetrical and systematic type of structures that centers around the core. 3)The core types are mostly central core types and a portion of central core is planned to place void and alight garden for improving the lighting and ventilating problems. 4)If we review our room arrangements, they are arranged from entrance kitchen, livingroom bedroom to bathroom to the end. Livingrooms and dinning rooms are normally formed together. 5)If external resident blocks are facing the open air, one of the surface is on view axis, kitchen or bathroom are symmetrically located on the other side which faces the units for the purpose of ventilating.

  • PDF

Development of an Average Bi-directional Flow Tube for the Measurement of Single and Two phase Flow Rate (단상 및 이상유동 유량 계측을 위한 평균 양방향 유동 튜브 개발)

  • Yun, Byong-Jo;Kang, Kyong-Ho;Euh, Dong-Jin;Baek, Won-Pil
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.172-179
    • /
    • 2004
  • Average Bi-directional flow tube was suggested to measure single and two phase flow rate. Its working principle is similar with Pilot tube, however, it makes it possible to eliminate the cooling system which is normally needed to prevent from flashing in the pressure impulse line of Pilot tube when it is used in the depressurization condition. The suggested instrumentation was tested in the air-water vertical test section which has 80mm inner diameter and 10m length. The flow tube was installed at 120 of L/D from inlet of test section. From the test, single air and water flow rate was measured successfully. For the emasurement of two phase flow rate, Chexal drift-flux correlation was used. In the test a new correlation of momentum exchange factor was suggested. The test result shows that the suggested instrumentation using the measured void fraction and Chexal drift-flux correlation can predict the mass flow rates within $10\%$ error of measured data.

  • PDF

DEVELOPMENT OF THE MULTI-DIMENSIONAL HYDRAULIC COMPONENT FOR THE BEST ESTIMATE SYSTEM ANALYSIS CODE MARS

  • Bae, Sung-Won;Chung, Bub-Dong
    • Nuclear Engineering and Technology
    • /
    • v.41 no.10
    • /
    • pp.1347-1360
    • /
    • 2009
  • A multi-dimensional component for the thermal-hydraulic system analysis code, MARS, was developed for a more realistic three-dimensional analysis of nuclear systems. A three-dimensional and two-fluid model for a two-phase flow in Cartesian and cylindrical coordinates was employed. The governing equations and physical constitutive relationships were extended from those of a one-dimensional version. The numerical solution method adopted a semi-implicit and finite-difference method based on a staggered-grid mesh and a donor-cell scheme. The relevant length scale was very coarse compared to commercial computational fluid dynamics tools. Thus a simple Prandtl's mixing length turbulence model was applied to interpret the turbulent induced momentum and energy diffusivity. Non drag interfacial forces were not considered as in the general nuclear system codes. Several conceptual cases with analytic solutions were chosen and analyzed to assess the fundamental terms. RPI air-water and UPTF 7 tests were simulated and compared to the experimental data. The simulation results for the RPI air-water two-phase flow experiment showed good agreement with the measured void fraction. The simulation results for the UPTF downcomer test 7 were compared to the experiment data and the results from other multi-dimensional system codes for the ECC delivery flow.

Assessment of Two Wall Film Condensation Models of RELAP5/MOD3.2 in the Presence of Noncondensable Gas in a Vertical Tube

  • Park, Hyun-Sik;No, Hee-Cheon;Bang, Young-Seok
    • Nuclear Engineering and Technology
    • /
    • v.31 no.5
    • /
    • pp.465-475
    • /
    • 1999
  • The objective of the present work is to assess the analysis capability of two wall film condensation models, the default and the alternative models, of RELAP5/MOD3.2 on condensation experiments in the presence of noncondensable gas in a vertical tube of PCCS of CP-1300. In the calculation of a base case the default model of RELAP5/MOD3.2 under-predicts the heat transfer coefficients, and Its alternative model over-predicts them throughout the condensing tube, Also, both models over-predict the void fractions. The nodalization study shows that the variation of the node number does not change both modeling results of RELAP5/MOD3.2 Sensitivity study for varying input parameters shows that the inlet steam-air mixture flow rate, the inlet air mass fraction, and the inlet saturated steam temperature give significant changes of their heat transfer coefficients Run statistics show that the grind time of the default model is always higher than that of the alternative model by about 23%.

  • PDF