• 제목/요약/키워드: air ventilation rate

Search Result 377, Processing Time 0.027 seconds

Evaluation of Odor Reduction in the Enclosed Pig Building Through Spraying Biological Additives (생물학적 첨가제 살포에 의한 밀폐형 돈사에서의 악취 저감 평가)

  • 김기연;최홍림;고한종;이용기;김치년
    • Journal of Animal Science and Technology
    • /
    • v.48 no.3
    • /
    • pp.467-478
    • /
    • 2006
  • Maintenance of an optimal air quality in the enclosed pig building is potentially important in terms of pig performance and farmer health. The objective of this on-site experiment is to evaluate and compare efficiencies of currently utilized biological additives to reduce odor emissions from the enclosed pig building. As a result, generally all the additives except for salt water, artificial spice and essential oil were proved ineffective in reducing odor generation. The beneficial effects of salt water, artificial spice and essential oil on odor reduction were highlighted on ammonia, odor intensity and offensiveness, and sulfuric odorous compounds, respectively. To efficiently utilize odor masking agent such as the artificial spice, ventilation rate should keep slightly lower than the optimal level. Essential oil functioned well as not only masking agent but also antimicrobial agent for reducing odor. To precisely quantify odor concentration, it should be measured by not the odor sensor but the olfactometry technique.

Diurnal Variations of Equilibrium Factor and Unattached fraction of Radon Progeny in Some Houses and Laboratories (가옥 및 실험실내 라돈평형인자, 비 흡착 라돈자손 비율의 일일 변동 특성)

  • Lee, Seung-Chan;Kim, Chang-Kyu;Lee, Dong-Myung;Kang, Hee-Dong
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.4
    • /
    • pp.399-408
    • /
    • 2001
  • The variation characteristics of radon concentration, equilibrium equivalent concentration and equilibrium factor in some houses and laboratory buildings have been studied. The variation of equilibrium factor and the unattached fraction of radon progeny with ventilation condition have been also estimated. The averages of radon concentration, equilibrium equivalent concentration and equilibrium factor were $30\;Bq\;m^{-3},\;19.6\;Bq\;m^{-3}$ and 0.65 in seven houses, while $55.0\;Bq\;m^{-3},\;31.9\;Bq\;m^{-3}$ and 0.58 in three laboratory buildings, respectively. The diurnal variation of radon concentration, equilibrium equivalent concentration and equilibrium factor in indoor showed a typical pattern that the radon concentration, equilibrium equivalent concentration and equilibrium factor increased at dawn and morning, while decreased at midday and evening. While the equilibrium factor rate deceased in the indoor environment which was well ventilated, the unattached traction of radon progeny increased. The equilibrium factor was in proportion to air pressure and humidity of indoor, whereas in Inverse proportion to temperature.

  • PDF

Phyto-restoration Potential of Soil Properties using Secale cereale for Recycle of Soils with Residual TPHs (Total Petroleum Hydrocarbons) after Off-site Treatment (잔류유분 함유 반출처리토 재활용을 위한 호밀 식재 식물상 토성회복 가능성)

  • Park, Jieun;Bae, Bumhan;Joo, Wanho;Bae, Seidal;Bae, Enjoo
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.3
    • /
    • pp.25-32
    • /
    • 2014
  • The amount of TPH contaminated soil treated at off-site remediation facilities is ever increasing. For the recycle of the treated-soil on farmlands, it is necessary to restore biological and physico-chemical soil characteristics and to remove residual TPH in the soil by an economic polishing treatment method such as phytoremediation. In this study, a series of experiments was performed to select suitable plant species and to devise a proper planting method for the phyto-restoration of TPH-treated soil. Rye (Secale cereale) was selected as test species through a germination test, among 5 other plants. Five 7-day-old rye seedlings were planted in a plastic pot, 20 cm in height and 15 cm in diameter. The pot was filled with TPH-treated soil (residual TPH of 1,118 mg/kg) up to 15 cm, and upper 5 cm was filled with horticulture soil to prevent TPH toxic effects and to act as root growth zone. The planted pot was cultivated in a greenhouse for 38 days along with the control that rye planted in a normal soil and the blank with no plants. After 38 days, the above-ground biomass of rye in the TPH-treated soil was 30.6% less than that in the control, however, the photosynthetic activity of the leaf remained equal on both treatments. Soil DHA (dehydrogenase activity) increased 186 times in the rye treatment compared to 10.8 times in the blank. The gross TPH removal (%) in the planted soil and the blank soil was 34.5% and 18.4%, respectively, resulting in 16.1% increase of net TPH removal. Promotion of microbial activity by root exudate, increase in soil permeability and air ventilation as well as direct uptake and degradation by planted rye may have contributed to the higher TPH removal rate. Therefore, planting rye on the TPH-treated soil with the root growth zone method showed both the potential of restoring biological soil properties and the possibility of residual TPH removal that may allow the recycle of the treated soil to farmlands.

Study on the Fire Risk Prediction Assessment due to Deterioration contact of combustible cables in Underground Common Utility Tunnels (지하공동구내 가연성케이블의 열화접촉으로 인한 화재위험성 예측평가)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.1
    • /
    • pp.135-147
    • /
    • 2015
  • Recent underground common utility tunnels are underground facilities for jointly accommodating more than 2 kinds of air-conditioning and heating facilities, vacuum dust collector, information processing cables as well as electricity, telecommunications, waterworks, city gas, sewerage system required when citizens live their daily lives and facilities responsible for the central function of the country but it is difficult to cope with fire accidents quickly and hard to enter into common utility tunnels to extinguish a fire due to toxic gases and smoke generated when various cables are burnt. Thus, in the event of a fire, not only the nerve center of the country is paralyzed such as significant property damage and loss of communication etc. but citizen inconveniences are caused. Therefore, noticing that most fires break out by a short circuit due to electrical works and degradation contact due to combustible cables as the main causes of fires in domestic and foreign common utility tunnels fire cases that have occurred so far, the purpose of this paper is to scientifically analyze the behavior of a fire by producing the model of actual common utility tunnels and reproducing the fire. A fire experiment was conducted in a state that line type fixed temperature detector, fire door, connection deluge set and ventilation equipment are installed in underground common utility tunnels and transmission power distribution cables are coated with fire proof paints in a certain section and heating pipes are fire proof covered. As a result, in the case of Type II, the maximum temperature was measured as $932^{\circ}C$ and line type fixed temperature detector displayed the fire location exactly in the receiver at a constant temperature. And transmission power distribution cables painted with fire proof paints in a certain section, the case of Type III, were found not to be fire resistant and fire proof covered heating pipes to be fire resistant for about 30 minutes. Also, fire simulation was carried out by entering fire load during a real fire test and as a result, the maximum temperature is $943^{\circ}C$, almost identical with $932^{\circ}C$ during a real fire test. Therefore, it is considered that fire behaviour can be predicted by conducting fire simulation only with common utility tunnels fire load and result values of heat release rate, height of the smoke layer, concentration of O2, CO, CO2 etc. obtained by simulation are determined to be applied as the values during a real fire experiment. In the future, it is expected that more reliable information on domestic underground common utility tunnels fire accidents can be provided and it will contribute to construction and maintenance repair effectively and systematically by analyzing and accumulating experimental data on domestic underground common utility tunnels fire accidents built in this study and fire cases continuously every year and complementing laws and regulations and administration manuals etc.

Effects of Higher Dietary Cation with or without Protected Fat and Niacin on the Milk Yield and Thermoregulatory Ability in Holsteins During Summer Heat Stress (여름철 고온스트레스 기간에 고 양이온 사료와 반추위 보호지방과 나이아신의 추가공급시 착유우의 유생산 및 체온조절에 미치는 영향)

  • 김현섭;이왕식;이현준;기광석;백광수;안병석;아주말 칸
    • Journal of Animal Science and Technology
    • /
    • v.48 no.4
    • /
    • pp.555-562
    • /
    • 2006
  • The objective of this study was to evaluate the effects of dietary cation-anion difference (DCAD) with or without ruminally protected fat and niacin on the thermoregulatory ability, milk yield and milk composition of lactating dairy cows during summer in Korea. Thirty mid-lactating Holstein cows (134±12.4 DIM and 23.4±2.3kg/d of milk yield) were divided into three groups (10 animals/group). Cows were housed in a free-stall barn and were provided with forced- air ventilation (wind velocity = 4 m/s) using 41 cm diameter fans. Diet one was formulated to contain low DCAD (+15 DCAD) while the remaining two diets were higher in DCAD (+30 DCAD). One higher DCAD diet was formulated to contain by-pass fat and the second higher DCAD diet contained the niacin along with by-pass fat. The maximum ambient temperature during July was 28.5℃ which could be seen as a period of mild heat stress. As summer progressed, August was characterized as a severe heat stress condition with maximum ambient temperature (32.4℃) and THI (74.0). Dry matter, crude protein and total digestible nutrients intake was not affected by the DCAD level and supplementation of ruminally protected fat or niacin. Milk production was higher in cows fed diets supplemented with fat and niacin than those fed un-supplemented diet. No difference in milk yield was observed in cows fed diets supplemented with fat or niacin plus fat. Milk fat and rectal temperature were not affected by the DCAD level and supplementation of ruminally protected fat or niacin. However, respiration rate was decreased in cows fed diets supplemented with either fat or fat and niacin compared to those fed. The results of the present study indicated that higher DCAD (+30) and supplementation of fat along with niacin can somehow mitigate the negative effects of heat stress on milk yield and physiology of lactating Holsteins during July and August in Korea. In present study reduced respiration rate and increased milk yield in lactating cows may be attributed to the cooling effect of supplemented fat along with vasodilatory functions of niacin. (Key Words: DCAD, Heat stress, THI, milk yield, Milk fat, Holstein)

Improvement of Shelf-life and Quality in Fresh-Cut Tomato Slices:

  • Hong Ji Heun
    • Proceedings of the Korean Society of Postharvest Science and Technology of Agricultural Products Conference
    • /
    • 2004.10a
    • /
    • pp.67-72
    • /
    • 2004
  • Quality of fresh-cut tomato slices was compared during cold storage under various modified atmosphere packaging conditions. Chilling injury of slices in containers sealed with Film A was higher than with Film B; these films had oxygen transmission rates of 87.4 and 60.0 ml $h^{-1}\;m^{-2}\;atm^{-1}$ at $5^{\circ}C\;and\;99\%$ RH, respectively. While slices in containers with an initial atmospheric composition of air, $4\%\;CO_2+1\;or\;20\%\;O_2,\;8\%\;CO_2+1\;or\;20\%\;O_2,\;or\;12\%\;CO_2+20\%\;O_2$ showed fungal growth, slices in containers with $12\%\;CO_2+1\%\;O_2$ did not. Low ethylene in containers enhanced chilling injury. Modified atmosphere packaging provided good quality tomato slices with a shelf-life of 2 weeks or more at $5^{\circ}C$. Experiments were conducted to compare changes in quality of slices of red tomato (Lycopersicon esculentum Mill. 'Sunbeam') fruit from plants grown using black polyethylene or hairy vetch mulches under various foliar disease management systems including: no fungicide applications (NF), a disease forecasting model (Tom-Cast), and weekly fungicide applications (WF), during storage at $5^{\circ}C$ under a modified atmosphere. Slices were analyzed for firmness, soluble solids content (SSC), titratable acidity (TA), pH, electrolyte leakage, fungi, yeasts, and chilling injury. With both NF and Tom-Cast fungicide treatments, slices from tomato fruit grown with hairy vetch (Vicia villosa Roth) mulch were firmer than those from tomato fruit grown with black polyethylene mulch after 12 days storage. Ethylene production of slices from fruit grown using hairy vetch mulch under Tom-Cast was about 1.5- and 5-fold higher than that of slices from WF and NF fungicide treatments after 12 days, respectively. The percentage of water-soaked areas (chilling injury) for slices from tomato fruit grown using black polyethylene mulch under NF was over 7-fold that of slices from tomato fruit grown using hairy vetch under Tom-Cast. When stored at $20^{\circ}C$, slices from light-red tomato fruit grown with black polyethylene or hairy vetch mulches both showed a rapid increase in electrolyte leakage beginning 6 hours after slicing. However, slices from tomato fruit grown using the hairy vetch mulch tended to have lower electrolyte leakage than those grown with black polyethylene mulch. These results suggest that tomato fruit from plants grown using hairy vetch mulch may be more suitable for fresh-cut slices than those grown using black polyethylene mulch. Also, use of the disease forecasting model Tom-Cast, which can result in lower fungicide application than is currently used commercially, resulted in high quality fruit for fresh-cut processing. Experiments were conducted to determine if ethylene influences chilling injury, as measured by percentage of slices exhibiting water-soaked areas in fresh-cut tomato slices of 'Mountain Pride' and 'Sunbeam' tomato (Lycopersicon esculentum Mill.). Ethylene concentration in containers without ventilation significantly increased during storage at $5^{\circ}C$, whereas little or no accumulation of ethylene occurred in containers with one or six perforations. Chilling injury was greatest for slices in containers with six perforations, compared to slices in containers with one perforation, and was over 13-fold greater than that of slices in control containers with no perforations. An experiment was also performed to investigate the effectiveness of including an ethylene absorbent pad in containers on subsequent ethylene accumulation and chilling injury. While ethylene in the no-pad controls increased continually during storage of both 'Mountain Pride' and 'Sunbeam' tomatoes at $5^{\circ}C$ under modified atmosphere conditions, no increase in accumulation of ethylene was observed in containers containing ethylene absorbent pads throughout storage. The ethylene absorbent pad treatment resulted in a significantly higher percentage of chilling injury compared with the no-pad control. In studies aimed at inhibiting ethylene production using AVG during storage of slices, the concentration of ethylene in control containers (no AVG) remained at elevated levels throughout storage, compared to containers with slices treated with AVG. Chilling injury in slices treated with AVG was 5-fold greater than that of controls. Further, we tested the effect of ethylene pretreatment of slices on subsequent slice shelf-life and quality. In slices treated with ethylene (0, 0.1, 1, or $10\;{mu}L\;L^{-1}$) immediately after slicing, ethylene production in non-treated controls was greater than that of all other ethylene pre-treatments. However, pretreatment of slices 3 days after slicing resulted in a different pattern of ethylene production during storage. Ihe rate of ethylene production by slices treated with 1 L $L^{-1}$ ethylene 3 days after slicing was greater during storage than any of the other ethylene treatments. With slices pre-treated with ethylene, both immediately and 3 days after slicing, the rate of ethylene production tended to show an negative correlation with chilling injury. Chemical name used: 1-aminoethoxyvinylglycine (AVG).

  • PDF

Epidemic acute interstitial pneumonia in children occurred during the early 2006s (2006년 초에 유행한 소아 급성 간질성폐렴)

  • Cheon, Chong Kun;Jin, Hyun-Seung;Kang, Eun Kyeong;Kim, Hyo Bin;Kim, Byoung-Joo;Yu, Jinho;Park, Seong Jong;Hong, Soo-Jong;Park, June Dong
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.4
    • /
    • pp.383-390
    • /
    • 2008
  • Purpose : This study was aimed to analyze the clinical characteristics of patients with acute interstitial pneumonia who had presented similar clinical patterns from March to June, 2006 and to describe our experience of treatment and to identify risk factors associated with prognosis. Methods : The clinical characteristics, radiologic and histopathologic findings and response to steroids of 15 patients (non-survival group [n=7] and survival group [control, n=8]) with acute interstitial pneumonia were investigated through the review of medical records. Results : The mean age of the patients was 26 (range: 3-48) months. Cough, cyanosis and fever were frequent symptoms. The most frequent radiologic findings on admission were pneumomediastium and extensive ground glass opacity. Surgical lung biopsy was performed on 8/15 (53.3%) patients and diffuse alveolar damage was found. Mechanical ventilation was applied for 9/15 (60.0%) patients for 40 (range: 1-99) days. Five patients in survival group received steroid treatment and 7 patients in non-survivial group (P=0.20). One patient in survival group received steroid pulse treatment and 4 patients in non-survival group (P=0.12). Seven patients died all of respiratory failure. The survival rate was 53.4%. Conclusion : The patients with acute interstitial pneumonia which occurred on spring 2006 showed high mortality because of rapidly and extensively progressing pulmonary fibrosis and air leakage. Therefore, we should consider surgical lung biopsy and steroid application earlier. We should recognize this acute interstitial pneumonia occurring on spring in domestics and need to investigate the cause and treatment in large scale.