• Title/Summary/Keyword: air ventilation rate

Search Result 378, Processing Time 0.032 seconds

Evaluation of Natural Ventilation Performance using the Multi-Functional Floor Heating System (다기능온돌시스템을 이용한 자연환기성능 평가)

  • Cho, Dong-Woo;Yu, Ki-Hyung;Yu, Jung-Yeon;Jung, Hae-Kwon
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.105-112
    • /
    • 2007
  • Recently developed raised floor heating system is not only capable of basic function to reduce noise between floors, but also is a multi-functional floor heating system enabling natural ventilation. The procedure of this system for natural ventilation is to import outdoor air through bottom space of the floor heating system, circulate indoor space and discharge it out of ceiling. In winter, powerless natural ventilation is possible with buoyancy effect caused by temperature difference between outdoor and indoor. And it also allows saving of energy by importing pre-heated air in bottom space of the floor heating system. To evaluate ventilation performance of this system, on-site measurement was conducted in 2 test laboratories, and the nominal air change rate was satisfied as 0.4$\sim$0.8 h-1 under the condition of outdoor temperature $5^{\circ}C{\sim}-5^{\circ}C$, which was evaluated as highly possible to be applied as a natural ventilation system in multi-family houses.

  • PDF

Analysis of Working Environment and Ventilation Efficiency in Pig House using Computational Fluid Dynamics (전산유체역학을 사용한 양돈장 내 작업환경 환기효율성 분석)

  • Oh, Byung-Wook;Lee, Seong-Won;Kim, Hyo-Cher;Seo, Il-Hwan
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.2
    • /
    • pp.85-95
    • /
    • 2019
  • The internal environment in pig house is closely related to the animal productivity. In addition, it is important to consider a working environment inside the pig house due to high gas and dust concentrations. The poor working environment inside the pig house can cause health problems including respiratory diseases. To analyze the working environment, it is important to evaluate the ventilation efficiency to effectively remove harmful gases and dust. The purpose of this study is to develop a 3D CFD model to analyze the working environment in the pig house. CFD model was validated by comparing air temperature distributions between CFD computed and field measured data. The average air flow rate at the pig height was 40.1 % lower than the working height when incoming air was concentrated on upper layer by the installed ventilation system on the experimental pig house. Using the validated CFD model, the regional ventilation efficiency was computed by the TGD(tracer gas decay) method at the pig and working heights. There was a difference of ventilation efficiency on 14 % between the air stagnated section and the rest sections. Stagnated gas concentration can be effected by animal and human health.

Effect of General Ventilation Rate on Concentrations of Gaseous Pollutants Emitted from Enclosed Pig Building (밀폐형 돈사 작업장의 전체 환기율이 가스상 오염물질 노출 농도 변화에 미치는 영향)

  • Kim, Ki Youn;Seo, Sung Chul;Choi, Jeong-Hak
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.1
    • /
    • pp.46-51
    • /
    • 2014
  • Objectives: The principal aim of this study was to compare the concentrations of gaseous pollutants emitted in enclosed pig buildings between different rates of general ventilation and determine the variations in the patterns of gaseous pollutants as affected by ventilation rate. Materials and Methods: The experiment was performed in the growing/finishing room($20.0m{\times}12.0m{\times}3.0m$) of a pig confinement building located on the experimental farm of Seoul National University. The conditions of the general ventilation rate for three treatments were 30%($4.12m^3s^{-1}$), 50%($6.87m^3s^{-1}$) and 70%($9.61m^3s^{-1}$). The data presented in the study were collected overa total of 45 days, 15 days for each of the three treatments from March to May 2011. A total of six air samplings were taken at 1.5m above the floor of the pig building. The environmental agents measured in the pig building were ammonia, hydrogen sulfide and odor concentration index for gaseous pollutants with temperature and hydrogen sulfide for thermal factors. Results: There were significant differences in the ammonia and odor concentration index in the pig building among the three general ventilation rate conditions(p<0.05), whereas hydrogen sulfide did not show a significant difference among three conditions of general ventilation rate(p>0.05). As the general ventilation rate applied to the pig building increases, it appears that all the indoor environmental agents measured in this study simultaneously decrease. Conclusions: The gaseous pollutants significantly affected by the general ventilation rate in pig building were ammonia and odor concentration index(p<0.05). However, it was found that hydrogen sulfide and thermal factors, temperature and relative humidity were not influenced significantly by variation in the general ventilation rate.

Evaluation of Carbon Dioxide Concentrations and Ventilation Rates in Elementary, Middle, and High Schools (초·중·고등학교의 이산화탄소 농도 및 환기량 평가)

  • Choe, Youngtae;Heo, Jung;Park, Jinhyeon;Kim, Eunchae;Ryu, Hyoensu;Kim, Dong Jun;Cho, Mansu;Lee, Chaekwan;Lee, Jongdae;Yang, Wonho
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.3
    • /
    • pp.344-352
    • /
    • 2020
  • Objectives: Much attention has been paid to indoor air quality. Ventilation within schools is important because of indoor air quality and its effect on health and learning performance. In this study, we evaluated the carbon dioxide (CO2) concentrations and ventilation rates in schools. Methods: This study measured the concentration of CO2 in elementary, middle, and high school classrooms over six months. The seasons during the study were summer, fall, and winter. Sensor-based monitoring was used and the basic characteristics of the classroom were investigated. The body surface area of the students was used to calculate the CO2 generation rate, and the air change per hour (ACH) was evaluated using mass balance modeling. Results: The average CO2 concentration measured in most schools exceeded 1000 ppm. The ventilation rates varied from season to season. Compared to the recommended ventilation rate of 4.9 ACH, the roughly 3 ACH calculated in this study indicates that most schools possessed insufficient ventilation. Conclusions: The concentration of CO2 in school classrooms could be an indicator of indoor air quality and can affect students' learning ability. In this study, CO2 concentrations exceeding the standard indicate a lack of ventilation along with problems with indoor air quality. Therefore, appropriate improvements are needed to overcome these problems.

A Study on the Air Flow Characteristics in an Apartment Complex and Ventilation Performance of an Individual Unit for Improving IAQ (주동형태 변화에 따른 아파트 단지내 기류분석 및 단위주호의 환기성능에 관한 연구)

  • Lee, Jung-Hyun;Lee, Seung-Hee;Kim, Taeyeon
    • KIEAE Journal
    • /
    • v.5 no.3
    • /
    • pp.11-16
    • /
    • 2005
  • The recent trends of high-density and high-rise in apartment housing have caused the problems of decrease in ventilation rates and increase of indoor pollutant contaminants. SHS(Sick House Syndrome) has now become a major issue and threats the health of residents. To solve these indoor air problems, increase in ventilation rate is considered as one of the most efficient approach. Thus, the recent housing development is pursuing improvement in the site design and the layout of apartment building blocks to promote natural ventilation is now investigated as one of the fundamental solutions. This study was focused on the air flow characteristics of outdoor environment in an apartment complex to keep the pollutants out of the site. Age of air and pressure difference have been used as indices of the outdoor air quality. Four different types of apartment building layouts have been analyzed by CFD simulation. This study again selected a real apartment housing complex as a case study model. By analyzing the pressure differences between the front and rear of an apartment building block, the ventilation performance in each individual unit was evaluated, and its impact on ventilation performance is investigated by analyzing the stagnant air around the apartment building blocks. During this process, existing patterns of apartment housing layout have been evaluated, and the most appropriate site layout has been chosen to analyze the outdoor airflow patterns. Based on the analysis of airflow patterns of site layout, the possibilities of improving ventilation performance of an individual apartment housing is proposed.

Comparative Study on Efficiencies of Naturally-Ventilated Multi-Span Greenhouses in Korea (다연동 온실의 자연환기효율성 비교 분석)

  • Kwon, Soon-Hong;Jung, Sung-Won;Kwon, Soon-Gu;Park, Jong-Min;Choi, Won-Sik;Kim, Jong-Soon
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.20 no.1
    • /
    • pp.8-18
    • /
    • 2017
  • This research analyzed the ventilation effect of the multi-span greenhouse based on the types of greenhouse structure, weather conditions, and locations inside the greenhouse. To compare and analyze the ventilation effects with different types of greenhouse, the uniform environmental conditions should be selected in advance. But these factors are not controlled and require tense many precision facilities and labor forces. Thus, the CFD simulation was used for the air stream to be analyzed qualitatively and quantitatively. In addition, for the ventilation effect analysis, the TGD (Tracer Gas Decay) was used to overcome the shortcomings of the current ventilation measurement method. The calculation error of ventilation rate using TGD was low (10.5%). Thus, the TGD is very effective in calculating the ventilation efficiency. The wind direction of 90 degrees showed the best ventilation effect. The ventilation rate also decreased along the air circulation path, and the rate was the lowest around the outlet. The computed fluid method (CFD) turned out to be a power tool for simulating flow behavior in greenhouse.

Evaluation of Ventilation Systems in an Enclosed Growing Pig House (무창육성돈사의 환기시스템에 따른 환기효율 평가)

  • Song, J.I.;Choi, H.L.
    • Journal of Animal Science and Technology
    • /
    • v.44 no.1
    • /
    • pp.135-144
    • /
    • 2002
  • An experiment was conducted to evaluate a ventilation system, which was devised to encourage farmers to use the enclosed growing and finishing pig housing system. A roof-air-entry ventilation system in winter and a side-wall-air-entry system in summer were evaluated. Air flow rate on the floor level which is the low part of pen and the living area of pigs in the enclosed growing and finishing pig house during winter was measured at 0 to 0.19 m/s at the minimum ventilation efficiency of 1,440 $m^{3}/h$. During summer the air flow rate was detected at 0.07 to 0.42 m/s at the maximum ventilation efficiency of 24,000 $m^{3}/h$. Therefore, it is concluded that the side-wall ventilation system is suitable for growing and finishing pigs in the enclosed house during the days of mid-summer and the roof-ventilation system was suitable during the coldest days of mid-winter. In addition, although the enclosed pig house has the system in which air exhausts through only one side wall, air should enter through both-side walls for the better ventilation performance.

Analysis on the Optimum Location of an Wet Air Cleaner in a Livestock House using CFD technology (전산유체역학 기법을 이용한 돈사 내 습식 공기 정화기의 적정 위치 설계)

  • Kwon, Kyeong-Seok;Lee, In-Bok;Hwang, Hyun-Seob;Bitog, Jessie.P.;Hong, Se-Woon;Seo, Il-Hwan;Choi, Ji-Sun;Song, Sang-Hyeon;Moon, Oun-Kyung
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.52 no.3
    • /
    • pp.19-29
    • /
    • 2010
  • In South Korea, as the living standard has been getting higher, meat consumption is steadily increasing. To meet the country's demand, livestock houses become larger and wider with increased raising density. In larger livestock houses, pollutants such as flake of pig skin, excrement, odor, various dusts and noxious gas like ammonia are excessively accumulated inside the facility. These will cause weak immunity for the pigs, diminution of productivity and degeneration of working condition. These problems can be solved through the ventilation performance of the facility. In the winter time, ventilation must be controlled to minimum to maintain a suitable thermal condition. However, this affects the other internal environmental condition because of the minimum ventilation. The installation of "wet air cleaner" especially in the winter time can be an alternative solution. For efficient application of this machine, there is a need to understand the existing ventilation condition and analyze the interaction of existing ventilation system with the wet air cleaner considering its appropriate location. In this study, the existing ventilation system as well as the internal environmental condition negatively inside the facility with the wet air cleaner has been studied using CFD technology. The CFD simulation model was validated from the study conducted by Seo et al. (2008). Results show that the elimination rate of ammonia was 39.4 % and stability could be improved to 35.1 % (Comparing case 5 to 1 where wet air cleaner machine was not used). It can therefore be concluded that case 5 shows the optimum location of a wet air cleaner in the livestock house.

Low Temperature Storage of Rough Rice Using Cold-Air in Winter(I) - Storage Characteristics after Rough Rice Cooling - (겨울철 냉기를 이용한 벼의 저온저장(I) - 벼 냉각 후 저장특성 -)

  • Lee J. S.;Han C. S.;Ham T. M.;Yon K. S.
    • Journal of Biosystems Engineering
    • /
    • v.30 no.3 s.110
    • /
    • pp.155-160
    • /
    • 2005
  • The objective of this research was to establish a domestically available cooling storage technique by cold-air in winter, using winter cool air ventilation fur determining rough rice cooling method in the storage and dry bin. The rough rice storage characteristics of two test conditions, winter cool-air ventilation storage and ambient temperature storage, were evaluated from January to July 2001, using a storage and dry bin of 300-ton capacity. Results of this research are as follows: Grain temperature was from $-5.1\~-8.5^{\circ}C$ after winter cool-air ventilation, and grain initial temperature for ambient temperature bin storage was $0.3\~1.9^{\circ}C$. Moisture content of rough rice decreased from $0.28\;to\;0.93\%$ and from $1.53\;to\;1.92\%$ to compare with original moisture contents for winter cool-air ventilation, and for ambient temperature bin storage, respectively. Broken ratio of brown rice from winter cool-air ventilation bin increased from $0.16\;to\; 0.92\%$, and brown rice broken ratio was from $2.24\;to\;2.86\%$ for ambient temperature bin storage to compare with initial broken ratio. Hardness of stored rice increased along storage period increase in alt storage methods, and cooling bin storage increased rice hardness of 0.271kgf: this increasing was lower then the other methods from 0.059 to 2.239kgf. Germination rates were decreased approximately 9.03, 3.14 and $3.20\%$ for upper, middle, and bottom of ventilating winter air bin, respectively, and germination rates of 2.70, 3.47 and $4.14\%$ were approximately decreased for upper, middle, and bottom parts of ambient temperature bin storage, respectively.