• 제목/요약/키워드: air stream

검색결과 494건 처리시간 0.023초

성능선도에 의한 다통로 판형열교환기의 간이설계법 (An easy-to-use design procedure for multipass plate heat exchangers based on the performance plots)

  • 유호선;이근휘;방보청
    • 설비공학논문집
    • /
    • 제11권2호
    • /
    • pp.250-261
    • /
    • 1999
  • Based on a set of performance plots relating the design variables to the imposed conditions, an easy-to-use and versatile design procedure for chevron-type multipass plate heat exchangers is developed. In order for the present procedure to cover multipass with unequal passes and non-unity ratio of heat capacity rate, each stream number of transfer unit is adopted as the basic design variable instead of the exchanger number of transfer unit. It is found that there exists a unique relation between the stream and exchanger number of transfer units regardless of the chevron angle and the plate length. In addition, for a given value of the pressure drop the heat transfer area per unit mass flow rate can be expressed in terms of the stream number of transfer unit only. These two relationships in the form of simple plots constitute the framework of design. The sample results in comparison with the available data indicate that the present procedure includes the previous ones as a subset, and that every design method is affected essentially by the selection of specific correlations for the heat transfer coefficient and the friction factor.

  • PDF

Estimating the Air Temperature Cooling Effect of the Cheonggyechun Stream Restoration Project of Seoul, Korea

  • Park Chong-Hwa;Kwon Young-Sang
    • Journal of the Korean Institute of Landscape Architecture International Edition
    • /
    • 제2호
    • /
    • pp.120-129
    • /
    • 2004
  • Urban stream restoration projects can improve water quality, wildlife habitats, urban landscape, outdoor recreation spaces, and urban microclimate. The objectives of this research were to investigate temperature cooling effect of urban streams by using satellite imagery, to evaluate environmental variables related to stream cooling effect, and to estimate the cooling effect of the Cheonggye stream restoration project of Seoul, Korea. Findings of this research can be summarized as follows. First, a method of estimating temperature distribution around urban streams by using satellite imagery was developed. Scatter plots of distance from stream edges and average temperature obtained through multiple buffering were used for the estimation. Second, urban temperature cooling effect of streams was estimated by comparing background temperature and temperature of each buffer zone. Third, environmental factors affecting stream cooling effect were also identified. Fourth, the temperature cooling effect of the restoration project was estimated based on three scenarios. An estimated cooling effect based on the average cooling effect of existing tributaries showed the most significant effect; $2.0^{\circ}C$ lower than the present level at the edge of the renovated stream. It was estimated that the temperature of the same area would be $1.4^{\circ}C$ cooler than the present level if the cooling effect of the Yangjaechun was used as the bench mark But the effect would be $1.2^{\circ}C$ lower than the present level if environmental variables related to the temperature cooling effect of urban streams were used as the bench mark.

  • PDF

액적의 증발에 미치는 수증기 농도의 영향 (Effects of Water Vapor Concentration on a Droplet Evaporation)

  • 김용우;이명준;하종률;정성식
    • 한국분무공학회지
    • /
    • 제4권1호
    • /
    • pp.27-33
    • /
    • 1999
  • An experimental study has been conducted to clarify the effect of vapor on droplet evaporation. Droplets of water, ethanol, n-hexadecane and n-heptane were exposed in air stream. Temperature, pressure, and flow velocity in the ambient air are 470K, 1 atm, and 2m/s, respectively. Measurements are carried out for the wide range of water vapor concentration$(0%\sim40%)$. To obtain the time histories of droplet diameter, suspended droplet in hot and humid air stream was synchronized with a back flash light, and enlarged droplet images were taken on a CCD camera. With the vapor concentration increasing, the evaporation rate constant of water droplet decrease slightly and the droplet of ethanol and n-heptane increase actively. The evaporation rate constant of n-hexadecane which has higher boiling point than water increases within around 30% of the concentration.

  • PDF

확장표면을 적용한 액체식 제습시스템의 성능특성에 관한 연구 (Performance characterization of liquid desiccant system with extended surface)

  • 장영수;송귀은;이대영
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.639-644
    • /
    • 2009
  • This study presents the new idea of liquid desiccant system with extended surface to reduce the system size. The extended surface is inserted between vertical cooling/heating tubes to increase the mass transfer area, and the liquid desiccant flows through the tube wall and the extended surface. Mathematical models for heat and mass transfer between liquid desiccant and air stream at tube wall and extended surface are provided. Dimensionless design parameters governing heat and mass transfer phenomena around the tube and the extended surface are identifier, and dimensionless operating parameters depicting system operating condition including flow rate ratio between dehumidification/regeneration processes, and mass flow rate ratio between air stream and liquid desiccant are explained. The effects of the parameters on system performance are summarized.

  • PDF

고온.저산소 농도영역중의 분무연소해석 (Computer Simulation of Liquid-Fuelled Combustor in Hot Vitiated-Air Stream)

  • 김태한;최병륜
    • 대한기계학회논문집
    • /
    • 제17권12호
    • /
    • pp.3187-3195
    • /
    • 1993
  • Combustion of liquid-fuelled combustion in a high-temperature vitiated-air stream was studied. The mathematical formulation comprise the application of Eulerian conservation equation to the gas phase and Lagrangian equation of droplet motion. The latter is coupled with a droplet-tracking technique (PSI-CELL Model) which regard the droplet phase as a source of mass, momentum, and energy to the gaseous phase. Reaction rate is determined by taking into account the Arrhenius reaction rate based on a single-step reaction mechanism. The calculated profiles show somewhat uncertainess at the upstream, but bases data for designing the combustor followed by 2-phase flow were obtained.

선박용 소각로 이젝터의 배출온도 변화에 따른 유동과 배기특성 (The Stream and Exhaust Gas Characteristics for Variation of Exhaust Gas Temperature of Marine Incinerator Ejector)

  • 김태한
    • 한국해양공학회지
    • /
    • 제14권2호
    • /
    • pp.60-64
    • /
    • 2000
  • An experimental study was performed to investigate the optimal ejector and operating condition of vessel incinerator. Exhaust gas temperature and secondary air which makes vacuum pressure at ejector throat regions were considered as an important factor. According to the measurement of pressure temperature and nitrogen oxides between non combustion and combustion we found the stream and exhaust gas characteristics of incinerator. This results can give us the exhaust gas temperature control system air pollutant reduction method and the optimum ejector design.

  • PDF

측정방법에 따른 흡기포트 분사식 다공 가솔린인젝터의 분무각 비교 (Comparison of Spray Angles of Multihole Port Fuel Gasoline Injector with Different Measuring Methods)

  • 김재호;임정현;노수영;문병수
    • 한국분무공학회지
    • /
    • 제5권3호
    • /
    • pp.17-26
    • /
    • 2000
  • The main parameter commonly used to evaluate spray distribution is spray angle. Spray angle is important because it influences the axial and radial distribution of the fuel. Spray angles were measured and compared for the two non-air assisted injectors such as 2hole-2stream 4hole-1stream injectors used for port fuel injection gasoline engines with n-heptane as a fuel by three different measuring techniques, i.e., digital image processing, shadowgraphy, and spray patternator, respectively. Fuel was injected with the injection pressures of 0.2-0.35 MPa into the room temperature and atmospheric pressure environment. In digital image processing approach, the selection of the transmittance level is critical to obtain the edge of spray and hence to measure the spray angle. From the measurement results by the shadowgraphy technique, it is dear that the spray angle is varied during the spray injection period. The measurement results from spray patternator show that the different spray angles exist in different region. Spray angle increases with the increase in the injection pressure. it is suggested that the spray angle and stream separated angle should be specified when spray is characterized for 2hole-2stream injector, because spray angle is much different though stream separated angle is same. It was also considerably affected by the measurement techniques introduced in this experimental work. However, the optimal axial distance for measuring the spray angle seems to be at least 60-80 mm from the injector tip for two non-air assisted injectors.

  • PDF

축열식 촉매 산화(RCO) 반응의 성능 최적화를 위한 전산 해석 (Numerical Calculations for the Optimal Performance of Regenerative Catalytic Oxidation(RCO))

  • 정유진;이재정;정종현;김진욱;손병현
    • 한국산학기술학회논문지
    • /
    • 제12권11호
    • /
    • pp.5384-5391
    • /
    • 2011
  • 본 논문에서는 RCO 반응기의 최적 조업 조건을 도출하고자 현재 조업 중인 RTO 반응기 촉매층의 압력분포, 유속분포, 유선장, 체류시간, 온도분포 등에 대하여 분석하였고 최적의 조업 조건을 도출하기 위한 전산유체해석을 수행하였다. 전산 해석 결과, 현재 조업중인 반응기 촉매층의 축열재로 인한 압력손실은 크지 않은 것으로 나타났으며, 세라믹 필터 이후 유속은 1.8~2.7 m/s로 특별한 편류없이 비교적 안정적 유속분포를 보이고 있었다. 기류분포를 좀 더 개선하려고 한다면 설비 내부에 플래넘과 촉매층 접속 구간 연장 등의 방법을 고려할 수 있을 것으로 판단된다. 그러나 기류 안내판이나 다공판 부착 등의 방법은 큰 효과는 없을 것으로 나타났다.

이류체 분사노즐의 혼합영역 형상에 따른 분무특성 (Spray characteristics on mixing region scale of twin fluid atomizer)

  • 김병문;김혁주;이충원
    • 대한기계학회논문집
    • /
    • 제15권6호
    • /
    • pp.2147-2159
    • /
    • 1991
  • 본 연구에서는 가장 다순한 내부혼합형 이류체분사노즐의 기류속도, 액체유량, 노즐직경 및 혼합길이, 기액접촉각을 변화시켜 평균입경(SMD), 분무각, 입도분포, 분 무분사량분포 등을 조사하여 노즐형상에 따른 분무특성의 변화를 자세히 밝혀, 분무특 성을 조절할 수 있는 이류체분사 노즐의 설계에 대한 기초적 자료를 제시하고자 한다.

기류순환이 연기농도와 감지기 작동에 미치는 영향 (Smoke Density and Operation of Fire Detector Influenced by Air Stream)

  • 이복영;이병곤
    • 한국화재소방학회논문지
    • /
    • 제16권4호
    • /
    • pp.28-32
    • /
    • 2002
  • 성능위주의 화재감지설비 설계시 공조설비 또는 실내 온도조절장치에 의한 실내기류 순환으로 연기기류가 정상해석에 의한 연기분포, 연기농도가 형성되지 못하여 화재감지지연이 예상되는 것을 실험 및 분석을 통하여 성능위주의 예방설비 구현을 위한 연구를 수행하였다. 실험연구는 공조설비가 가동하고 있는 통신기계실의 화재시 화재감지기의 작동을 예측하고자 천장부의 연기농도분포를 측정·분석하는 실험을 수행하였으며, 그 결과 기류순환에 의해 기존 Passive Type의 화재감지장치는 감지불가 또는 감지지연이 예상되었으며, 조기화재감지를 위하여 방호공간의 공기를 강제로 흡입·분석하여 화재를 감지하는 Active Type의 Air Sampling Smoke Detection system의 적용이 필요한 것으로 나타났다.