• Title/Summary/Keyword: air situation assessment

Search Result 26, Processing Time 0.027 seconds

Development of RADCON and Establishments of Its Related System

  • Kim, Kuk-Ki;Lee, Kun-Jai;Park, Won jong
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05d
    • /
    • pp.51-56
    • /
    • 1996
  • In a NNP (Nuclear Power Plant) severe accident, radionuclides are dispersed into the air. The official regulatory institute, KINS (Korea Institute of Nuclear Safety), has been authorized and developing Computerized technical Advisory system for the Radiological Emergency preparedness (CARE). In this paper, in line with the CARE system, we presented the result of a modularized intermediate-level emergency dose assessment computer code. The RADCON (RADiological CONsequence analysis) version 3.0, which is operable on PC, is developed for simulating emergency situation by considering continuous washout phenomena, and provide a function of effective emergency planning. The source files are coded by using C language in order to increase the compatibility with the other computer system and modularized to adjust the functions and characteristics of each module fer easy understanding and further modification.

  • PDF

Health Risk Assessment and Analysis on the Volatile Organic Compounds in Some Workplace (모작업장에서 휘발성 유기오염물질의 분석과 근로자들의 건강위해성 평가)

  • Lee, Hyo-Min;Kim, Myung-Soo;Choi, Shi-Nai;Yoon, Eun-Kyung;Park, Jong-Sei
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.3 s.58
    • /
    • pp.530-539
    • /
    • 1997
  • This study was conducted to assess the health risk on the volatile organic compounds such as toluene, xylene, and styrene in painting workplace. It was monitored through personal air sampling during working time in selected 5 workplaces and analysed using gas chromatography. For the settlement of exposure situation, there were regarded working conditions such as working hours, yearly working days, and working years. Also, Monte-Carlo simulation was used for the induction of hazard index using toxicity value from IRIS(Integrated risk information system) database. The results of risk assessment were summarized as follows. 1. The air concentration of toluene was $7.096{\pm}15,644ppm,\;2.586{\pm}4.275ppm\;for\;xylene,\;1.914{\pm}5.320ppm$ for styrene in blast painting workplaces. The level of toluene was different significantly compared with the level of xylene and styrene. 2. Computated chronic daily intake values of 95th percentile on toluene, xylene and styrene treated by Monte-Carlo simulation were 9.616, 3.567, 2.782 mg/kg/day, respectively. 3. Computated hazard index values of 75th percentile on toluene, xylene and styrene treated by Monte-Carlo simulation were 3.5, 1.0 and 1.6, respectively. Adverse health effects on the toluene, xylene and styrene would be expected by working exposure in selected 5 workplaces since the hazard indices of three compounds were exceeded 1 in the surroundings of 75th percentile though having the low emerged frequency.

  • PDF

Proposal of a framework for evaluating the operational impact of cyber attacks on aviation weapons systems(EOICA) (항공무기체계 사이버공격에 대한 작전영향성평가 프레임워크 제안)

  • Hong, Byoung-jin;Kim, Wan-ju;Lee, Soo-jin;Lim, Jae-sung
    • Convergence Security Journal
    • /
    • v.20 no.4
    • /
    • pp.35-45
    • /
    • 2020
  • Cyber attacks on the aviation weapon system, a state-of-the-art asset, have become a reality and are approaching as a constant threat. However, due to the characteristics of embedded software of the current aviation weapon system, it is managed and operated without connection to the network in peacetime, so the response management to cyber attacks is relatively weak. Therefore, when a cyber attack becomes a reality, it is urgent to prepare and evaluate measures for the adverse effects that such attack will have on the execution of the Air Tasking Order(ATO). In this paper, we propose a framework for operational impact assessment in order to avoid confusion in ATO execution and systematic response to cyber attacks on aviation weapons systems. The proposed framework is designed to minimize the negative impact on operations against cyber attacks that may occur under no warning by analyzing the impact on air operations for each aviation weapon system and standardizing countermeasures for this. In addition, it supports the operational commander to make a quick decision to command for the execution of the operation even in a situation where a cyber attack occurs.

A Study on Statistical Parameters for the Evaluation of Regional Air Quality Modeling Results - Focused on Fine Dust Modeling - (지역규모 대기질 모델 결과 평가를 위한 통계 검증지표 활용 - 미세먼지 모델링을 중심으로 -)

  • Kim, Cheol-Hee;Lee, Sang-Hyun;Jang, Min;Chun, Sungnam;Kang, Suji;Ko, Kwang-Kun;Lee, Jong-Jae;Lee, Hyo-Jung
    • Journal of Environmental Impact Assessment
    • /
    • v.29 no.4
    • /
    • pp.272-285
    • /
    • 2020
  • We investigated statistical evaluation parameters for 3D meteorological and air quality models and selected several quantitative indicator references, and summarized the reference values of the statistical parameters for domestic air quality modeling researcher. The finally selected 9 statistical parameters are MB (Mean Bias), ME (Mean Error), MNB (Mean Normalized Bias Error), MNE (Mean Absolute Gross Error), RMSE (Root Mean Square Error), IOA (Index of Agreement), R (Correlation Coefficient), FE (Fractional Error), FB (Fractional Bias), and the associated reference values are summarized. The results showed that MB and ME have been widely used in evaluating the meteorological model output, and NMB and NME are most frequently used for air quality model results. In addition, discussed are the presentation diagrams such as Soccer Plot, Taylor diagram, and Q-Q (Quantile-Quantile) diagram. The current results from our study is expected to be effectively used as the statistical evaluation parameters suitable for situation in Korea considering various characteristics such as including the mountainous surface areas.

Impact of Future Chinese Emissions on Ozone Air Quality and Human Health in Northeast Asia (동북아 지역에서 중국의 미래 배출량 변화가 오존농도와 보건에 미치는 영향)

  • Kim, Hyeon-Kook;Lyu, Youngsook;Woo, Jung-Hun;Hong, Sung-Chul;Kim, Deok-Rae;Seo, Jeonghyeon;Shin, Myunghwan;Kim, Sang-Kyun
    • Journal of Climate Change Research
    • /
    • v.7 no.4
    • /
    • pp.451-463
    • /
    • 2016
  • We explore the impact of Chinese future air pollutant emissions on ozone air quality in Northeast Asia (NEA) and health in South-Korea using an assessment framework including ICAMS (The Integrated Climate and Air Quality Modeling System) and BenMAP (The Environmental Benefits Mapping and Analysis Program). The emissions data sets from the climate change scenarios, the Representative Concentration Pathways (RCPs) (emission scenarios, EMSO), are used to simulate ozone air quality in NEA in the current (1996~2005, 2000s), the near future (2016~2025, 2020s) and the distant future (2046~2055, 2050s). Furthermore, the simulated ozone changes in the 2050s are used to analyze ozone-related premature mortality and economic cost in South-Korea. While different EMSOs are applied to the China region, fixed EMSO are used for other country regions to isolate the impacts of the Chinese emissions. Predicted ozone changes in NEA are distinctively affected by large changes in NOx emission over most of China region. Comparing the 2020s with the 2000s situation, the largest increase in mean ozone concentrations in NEA is simulated under RCP 8.5 and similarly small increases are under other RCPs. In the 2050s in NEA, the largest increase in mean ozone concentrations is simulated under RCP 6.0 and leads to the occurrence of the highest premature mortalities and economic costs in South-Korea. Whereas, the largest decrease is simulated under RCP 4.5 leads to the highest avoided premature mortality numbers and economic costs. Our results suggest that continuous reduction of NOx emissions across the China region under an assertive climate change mitigation scenario like RCP 4.5 leads to improved future ozone air quality and health benefits in the NEA countries including South-Korea.

An Assessment of the Radiation Dose from Radiography with the Change in Air Gap (공극(기극(氣隙)) 변화에 따른 방사선촬영 선량평가)

  • Ahn, Byeong Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.6
    • /
    • pp.381-385
    • /
    • 2016
  • This study aims to propose a method for reducing radiation dose in high-voltage radiography using air gap technique while maintaining the same image quality as when using grids. For an experiment, air gaps were set at 10 cm, 15 cm, 20 cm, 25 cm, and 30 cm with a focus-receptor distance of 180 cm; with each air gap distance, tube current was set at 15 mAs, and tube voltage was set at 80 kVp, 85 kVp, 90 kVp, 95 kVp and 100 kVp. Then, radiographs were taken. In a situation of employing a conventional method of using grids, radiographs were taken at 15 mAs and 107 kVp with a focus-receptor distance of 180 cm. According to the results of the experiment, the surface radiation dose from radiography using grids was 0.130 R; the surface radiation dose at a 20cm air gap was 0.124 R; PSNR between these two images was 10.65 [dB]. In conclusion, the air gap distance, which could maintain the image quality similar to that of a case where scattered radiation was removed and grids were used with a small surface radiation dose, was 20 cm. The result of this study is thought to be used as an indicator to remove surface radiation dose in radiography using air gap.

An Analysis of Indoor Air Quality and Risk Assessment for One-room Housing around the University in the Post-Corona Era (포스트 코로나 시대의 대학교 주변 원룸형 주택에 대한 실내 공기질 분석 및 위해성 평가)

  • Bao, Wei;Jung, Jaeyoun;Jeong, Insoo
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.24 no.3
    • /
    • pp.23-30
    • /
    • 2022
  • In this study, in order to grasp the current situation of indoor environmental pollution and indoor ventilation in one-room around the university in the post-corona era, we analyzed the experimental data and conducted a questionnaire survey on university students. By analyzing the content, the effects of formaldehyde, dust and other pollution on the human body, which are usually not easily detectable, are digitized and more easily taken into account. Among the experimental results, the concentration of VOC and HCHO, gas pollutants among indoor pollutants, exceeded the recommended criteria of the Ministry of Environment in most studio apartments. Overall, the average CO2 concentration was lower than the Ministry of Environment's maintenance standard (1000ppm), but it was relatively high in summer and winter, and it is believed to be caused by cooling and heating in an enclosed space. The levels of PM2.5 and PM10, particulate pollutants, increased in November and December, and it is believed that ventilation defects due to degradation in external temperature. There was no clear difference between the two types, and there was a very high correlation between PM2.5 and PM10, HCHO and VOC. It was found that temperature was closely correlated with all sources except CO2, and humidity was closely correlated with all sources except PM2.5 and PM10. Health risk assessment was conducted for formaldehyde. The average ECR of studio R2 in May was 3.91E-4, and the ECR figure in September was 3.65E-4, which was very high compared to other residential spaces. The R2 level was calculated as 4 people per 10,000 people in the lifetime risk of cancer of residents, exceeding the allowable risk. R8 also showed higher ECR results than other spaces after R2, especially in October, 2.01E-4, six times higher than R7 measured in October, and 1.87E-4 in July, four times higher than R9.

Face Validity Analysis of Revised English Proficiency Test for Aviation (EPTA) - Based on the Pilot's Flying Experience - (개정된 항공영어구술능력시험(EPTA)의 안면타당도 분석 - 조종사의 비행경력을 중심으로-)

  • Choi, Kyung Ho;Kim, Soo-Yoon
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.28 no.4
    • /
    • pp.12-20
    • /
    • 2020
  • The purpose of this study was to analyze the face validity of the revised EPTA (English Proficiency Test for Aviation) to see if the tests actually contribute to the enhancement of aviation safety and achieve the purpose of the assessment. In order to reach the above objectives, 103 pilot test takers were surveyed, and nine in-depth interviewees were selected and interviewed. In addition, detailed research results were derived by dividing the participants into the pilot's flight experience (31 captain pilots, 42 first officer pilots, and 30 general commercial pilots). As a result, pilot participants were generally aware that EPTA was more reasonable because the revised EPTA properly implemented the aviation situation and gave participants motivation to learn aviation English. It was also seen that first officer pilots had a higher face validity of EPTA than captain and general commercial pilots. The reason was that first officer pilots considered air traffic control job was more important than other pilots did.

Instrument Flight Certification Process and Flight Test Results of Korean Utility Helicopter (한국형 기동헬기 계기비행 인증절차 및 비행시험 결과)

  • Kwon, Hyuk-Jun;Park, Jong-Hoo;Park, Jae-Young
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.2
    • /
    • pp.173-180
    • /
    • 2014
  • In this paper, the instrument flight certification process and flight test results of Korean Utility Helicopter (KUH) are presented. For the instrument flight certification, the suitability of installed equipments and instruments have been reviewed and verified by ground and flight tests. Next, static and dynamic stability test are conducted in accordance with FAR-29 Appendix B. The static stability is determined by the change of speed and attitude according to control inputs. The dynamic stability is evaluated by how quickly the response of the helicopter due to long and short period control inputs are decreased. The pilot workload evaluation are also carried out by simulated IMC flight tests. This paper presents the workload assessment results when some failures are occurred at cockpit instruments, engine or flight control systems as well as the normal situation. After the simulated IMC flight test is completed, actual instrument flight test are conducted in a real IMC environment according to the air traffic controls.

Analysis of Korean Medical status of Acute Bronchitis, Chronic Bronchitis and Allergic Rhinitis patients (급·만성 기관지염과 알레르기성 비염의 국내 의료 이용 현황 분석)

  • Jung, You Jin;Yang, Woong Mo
    • The Journal of Korean Medicine
    • /
    • v.40 no.3
    • /
    • pp.87-98
    • /
    • 2019
  • Objectives: Patients with respiratory diseases are increasing as air pollution due to fine dust gets worse. Diseases that occupy a large proportion of respiratory diseases in medical institutions are acute bronchitis, chronic bronchitis and Allergic rhinitis. The number of patients with all three diseases is gradually increasing. This study was to suggest assignment of medicine policy for improving accessibility to Korean medical treatment of respiratory diseases analyzing the current treatment status of acute bronchitis, Chronic bronchitis and Allergic rhinitis patients in Western medical and Korean medical institutes in this situation. Methods: This study used 2017 National patient sample data from the Korean Health Insurance Review and Assessment Service for research. Acute bronchitis, Chronic bronchitis, Allergic rhinitis was according to KCD code. This research contains Socio-demographic analysis classified by sex and age, the number of three disease's patients. Also the number of medical treatment, the expense of recuperation cost, medical practices were analyzed compare with Western and Korean medicine. Results: The incidence of three diseases is higher among female than male. There are many patients under the age of 10 in the case of acute bronchitis and allergic rhinitis, while there are many patients over 50 years of age in chronic bronchitis. Western medical treatment take up a larger proportion than Korean medical treatment in part of the number of three disease's patients, the number of medical treatment, the expense of recuperation cost. Conclusions: Much more patients of these diseases visit in Western medical clinic and hospital than Korean medical clinic and hospital for treatment. There are many parts of Korean medical treatment that are not covered by Health insurance benefits like herbal decoction, pharmacopuncture, etc. Korean medicine need to do the efforts for expanding medical field in variety. Also it is demanded for institutional support for reduction of the cost burden and improving on accessibility of Korean medical treatment in order to treat with the increase in respiratory diseases due to fine dust.