• Title/Summary/Keyword: air quality monitoring

Search Result 454, Processing Time 0.029 seconds

Analysis on the Correction Factor of Emission Factors and Verification for Fuel Consumption Differences by Road Types and Time Using Real Driving Data (실 주행 자료를 이용한 도로유형·시간대별 연료소모량 차이 검증 및 배출계수 보정 지표 분석)

  • LEE, Kyu Jin;CHOI, Keechoo
    • Journal of Korean Society of Transportation
    • /
    • v.33 no.5
    • /
    • pp.449-460
    • /
    • 2015
  • The reliability of air quality evaluation results for green transportation could be improved by applying correct emission factors. Unlike previous studies, which estimated emission factors that focused on vehicles in laboratory experiments, this study investigates emission factors according to road types and time using real driving data. The real driving data was collected using a Portable Activity Monitoring System (PAMS) according to road types and time, which it compared and analyzed fuel consumption from collected data. The result of the study shows that fuel consumption on national highway is 17.33% higher than the fuel consumption on expressway. In addition, the average fuel consumption of peak time is 4.7% higher than that of non-peak time for 22.5km/h. The difference in fuel consumption for road types and time is verified using ANOCOVA and MANOVA. As a result, the hypothesis of this study - that fuel consumption differs according to road types and time, even if the travel speed is the same - has proved valid. It also suggests correction factor of emission factors by using the difference in fuel consumption. It is highly expected that this study can improve the reliability of emissions from mobile pollution sources.

Chemical Characteristics and Particle Size Distribution of PM10 in Iron and Steel Industrial Complex (포항철강공단 미세먼지(PM10)의 입경분포 및 화학적 특성)

  • Jung, Jong-Hyeon;Lee, Hyung-Don;Jeon, Soo-Bin;Yoo, Jeong-Kun;Shon, Byung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.11
    • /
    • pp.5601-5609
    • /
    • 2012
  • The fine particulate matter($PM_{10}$) concentrations and contents were measured to check the health and environment influential factors in Pohang Iron and Steel Industrial Complex and its vicinities. In addition, the $PM_{10}$ distribution for each year and season was surveyed using the regional air quality monitoring stations. The measuring on the $PM_{10}$ inside the industrial complex showed $61.3{\pm}12.1{\mu}g/m^3$ for average concentration of $PM_{10}$ which was measured by Dongil Industry and $44.3{\pm}8.1{\mu}g/m^3$ measured by steel manufacturing industry complex management office. Both of them satisfied the environmental air quality standard. The percentage of $SO_4{^2}$, $NO_3{^-}$, $NH_4{^+}$ which are the secondary ions created out of the $PM_{10}$ in Dongil Industry and steel manufacturing industry complex management office was checked and it was revealed that the percentage of ${SO_4}^{2-}$ was high and it is considered that the pollution source related with the sulfides exist at the industrial complex. They were in order of ${SO_4}^{2-}$ > $Cl^-$ > $NO_3{^-}$ > $F^-$ > $NH_4{^+}$ in Dongil Industry and ${SO_4}^{2-}$ > $Cl^-$ > $NO_3{^-}$ > $NH_4{^+}$ > $F^-$ in steel manufacturing industry complex management office.

Measurement of Dust Concentration in a Naturally Ventilated Broiler House according to Season and Worker's Access (윈치커튼식 계사의 시기 및 작업자 출입에 따른 분진 발생 농도 측정 연구)

  • Jo, Ye-seul;Kwon, Kyeong-seok;Lee, In-bok;Ha, Tae-hwan;Park, Se-jun;Kim, Rack-woo;Yeo, Uk-hyeon;Lee, Sang-yeon;Lee, Seung-no
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.6
    • /
    • pp.35-46
    • /
    • 2015
  • Improvement in domestic poultry production has a positive effect on the export competitiveness of the poultry industry. However, overproduction and enlargement of facilities to assure a supply increase a stocking density which make a poor environment in the broiler house. In particular, an intensive rearing environment is vulnerable to dust control that causes respiratory diseases, such as asthma, bronchitis, etc., to farmers and broilers. However, monitoring data and research for environment control are not adequate, and there are no air quality regulations in broiler houses in Korea. In this study, TSP, PM10, inhalable dust and respirable dust concentration were monitored according to season, age of broiler and broiler's activities. Air quality assessment was also performed in accordance with the threshold limit value by Donham et al. (2000). The TSP concentrations were 77.5 %, 219.7 % higher and PM10 concentrations were 121.2 %, 303.8 % higher when change of season and winter respectively than summer. There were significantly different concentrations according to season and age of broiler. Inhalable and respirable dust concentration were also clearly different according to the season and age of broiler. A high dust concentration was observed, specifically exceeding the threshold limit by 119 % in the winter. In the case of the broiler's motion was activity according to worker's access into the broiler house, concentration level was 769.6 % higher than broiler's motion was stable and exceeded the threshold limit. These results suggest that the worker should put on protective equipment to protect there's respiratory health in the broiler house.

Distribution Characteristics of the Concentration of Ambient PM-10 and PM-2.5 in Daegu Area (대구지역 대기 중 PM-10과 PM-2.5의 농도분포 특성)

  • Do, Hwa-Seok;Choi, Su-Jin;Park, Min-Sook;Lim, Jong-Ki;Kwon, Jong-Dae;Kim, Eun-Kyung;Song, Hee-Bong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.1
    • /
    • pp.20-28
    • /
    • 2014
  • The three air quality monitoring sites, analysed simultaneously PM-10 and PM-2.5, ie. Ihyeondong in industrial area, Manchondong in residential area, Pyeongnidong in streetside, among 13 air quality monitoring sites in Daegu area, were investigated the concentration distribution characteristics of PM-2.5 and PM-10 in the last 2 years (2011~2012). PM-10 concentrations exceeded annual average reference value ($50{\mu}g/m^3$) in Ihyeondong ($52.5{\mu}g/m^3$) and Pyeongnidong ($60.9{\mu}g/m^3$) but satisfied in Manchondong ($44.9{\mu}g/m^3$). All PM-2.5 concentrations exceeded EPA annual standard value of the United States ($15{\mu}g/m^3$) in three points, but also exceeded new control annual standard value ($25{\mu}g/m^3$) coming into effect in 2015. Seasonal concentration of PM-10 appeared the order of spring > winter > fall > summer, and in the case of PM-2.5, the order was winter > spring > fall > summer. Monthly concentrations of PM-10 and PM-2.5 were highest in February and lowest in September. Diurnal concentrations of PM-10 and PM-2.5 increased from 7:00 AM, and recorded the highest concentration between 10:00 AM and 11:00 AM. And after 6:00 PM it lowered continuously and tended to show fixed concentrations from evening until early morning. In addition, the concentration of fine particles during the week was higher than the weekend. The fluctuation in industrial area was larger than the residential area. At the PM-2.5/PM-10 ratio, summer was generally high, spring was the lowest. And, when yellow sand occurred, it was 0.32 to 0.42. It was very low compared to 0.54 to 0.64 during non-yellow sand times. This paper for the state and the characteristics of Daegu' fine particles (PM-10, PM-2.5) will be valuable to future researches of fine particles and air pollution management.

A Study on the Efficient Measurement of Airborne Asbestos Concentrations at Demolition Sites of Asbestos Containing Buildings, etc. in Seoul (서울시내 석면함유 건축물 철거 현장 등에서의 효과적인 공기 중 석면농도 측정을 위한 연구)

  • Lee, Jinhyo;Lee, Suhyun;Kim, Jeongyeun;Kim, Jihui;Chung, Sooknye;Kim, Jina;Oh, Seokryul;Kim, Iksoo;Shin, Jinho;Eo, Soomi;Jung, Kweon;Lee, Jinsook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.2
    • /
    • pp.113-121
    • /
    • 2014
  • Objectives: This study is intended to seek credible and efficient measurements on airborne asbestos concentrations that allow immediate action by establishing complementary data through comparative analysis with existing PCM and KF-100 method real-time monitoring equipment in working areas in Seoul where asbestos-containing buildings are being demolished, including living environment surroundings. Materials: We measured airborne asbestos concentrations using PCM and KF-100 at research institutes, monitoring networks, subway stations and demolition sites of asbestos-containing buildings. Through this measurement data and KF-100 performance testing, we drew a conversion factor and applied it via KF-100. Finally we verified the relationship between PCM and KF-100 with statistical methods. Results: The airborne asbestos concentrations by PCM for the objects of study were less than the detection limit(7 fiber/$mm^2$) in three (20%) out of 15 samples. The highest concentration was 0.009 f/cc. The airborne asbestos concentrations by PCM in laboratories, monitoring networks, subway stations and demolition sites of asbestos-containing buildings were respectively $0.002{\pm}0.000$ f/cc, $0.004{\pm}0.001$ f/cc, $0.009{\pm}0.001$ f/cc, and $0.002{\pm}0.000$ f/cc. As a result of KF-100 performance testson rooftops, the conversion factor was 0.1958. Applying the conversion factor to KF-100 for laboratories, the airborne asbestos concentrations ratio of the two ways was nearly 1:1.5($R^2$=0.8852). Also,the airborne asbestos concentration ratio of the two ways was nearly 1:1($R^2$=0.9071) for monitoring networks, subway stations, and demolition sites of asbestos-containing buildings. As a result of independent sample t-tests, there was no distinction between airborne asbestos concentrations monitored in the two ways. Conclusions: In working areas where asbestos-containing buildings are being demolished, including living environment surroundings, quickly and accurately monitoring airborne asbestos scattered in the air around the working area is highly important. For this, we believea mutual interface of existing PCM and a real-time monitoring equipment method is possible.

Study on Chemical Characterization of PM2.5 based on Long-term Database (1990 ~ 2012) and Development of Chemical Species Profiles During Haze Days and Asian Dust Days in Yongin-Suwon Area (장기간 (1990 ~ 2012) 측정자료를 이용한 용인-수원지역에서의 PM2.5의 화학적 특성연구 및 헤이즈와 황사 현상 시 화학성분별 질량분율표의 개발)

  • Lim, Hyoji;Lee, Tae-Jung;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.3
    • /
    • pp.223-238
    • /
    • 2015
  • The $PM_{2.1}$ was collected by LVCI (low volume cascade impactor) during Group-A Period (September 1990 to December 2012) and the $PM_{2.5}$ was collected by HVAS (high volume air sampler) during Group-B Period (September 2009 to April 2012) at Kyung Hee University, Global Campus located on the boarder of Yongin and Suwon. The 8 water-soluble ions ($Na^+$, $NH_4{^+}$, $K^+$, $Mg^{2+}$, $Ca^{2+}$, $Cl^-$, $ NO_3{^-}$, and $SO_4{^{2-}}$) were analyzed by IC, and the 14 inorganic elements (Al, Mn, Si, Fe, Cu, Pb, Cr, Ni, V, Cd, Ba, Zn, Ti, Ag) were analyzed by XRF and ICP-AES after performing proper pre-treatments of each sample filter. The average total mass fractions of $SO_4{^{2-}}$, $NO_3{^-}$, and $NH_4{^+}$+ to $PM_{2.5}$ samples during Group-B Period were 0.39 in normal days, 0.44 in haze days, and 0.27 in Asian dust days, respectively; however, the average total mass fractions of Al, Fe, and Si to $PM_{2.5}$ mass were 0.043 in normal days, 0.021 in haze days, and 0.036 in Asian dust days, respectively. Especially the concentration of Pb was significantly decreased during Group-B Period rather than during Group-A Period, while Cr and Ni was increased during Group-B Period. In this study, we intensively compared the annual and seasonal patterns of major chemical species among normal days, haze days, and Asian dust days. Further we developed mass fraction profiles by collecting episode cases of haze days and Asian dust days, which were consisting of 22 chemical species. Those profiles are considered to be useful when applying various receptor models and establishing air quality management plans near future.

Seasonal Monitoring of Airborne Microbial Concentrations in Kindergartens (유치원의 실내환경에서 공기중 미생물 수의 계절적 변화)

  • Hwang, Gwang-Hwan;Lee, A-Mi;Sin, Hyeon-Jin;Kim, Jong-Seol
    • Korean Journal of Microbiology
    • /
    • v.39 no.4
    • /
    • pp.253-259
    • /
    • 2003
  • To assess microbiological indoor air quality in kindergartens, concentrations of viable airborne microorganisms were seasonally determined at three kindergartens in Ulsan from April, 2002 to January, 2003. Sampling was performed with an impaction-type air sampler and three different media. The numbers of bacteria grown on Staphylococcus medium were between 84 and 4,150 MPN/m3 with an average of 827 MPN/m3, and those on standard method agar ranged from 50 to 2,636 MPN/m3 with an average of 580 MPN/m3. The bacterial concentrations were highest in summer, followed by fall, spring, and winter, and were significantly correlated with indoor temperature. Among the colonies, 45.6~61.0% were observed as Gram-positive cocci and 8.5~20.6% were Gramnegative rods. Micrococcus species were the dominant organisms. The numbers of fungi ranged from 0 to 1,888 MPN/m3(661 MPN/m3 average) based on colony counts with dichloran rose bengal chloramphenicol agar. On average, the fungal concentrations were highest in summer and lowest in winter. Penicillium species and Aspergillus species were identified from the colonies. The obtained data can be utilized as a step to set a guideline for bioaerosols in indoor environment of schools.

Environmental monitoring system research based on low-power sensor network (저전력 센서네트워크 기반 환경모니터링 시스템 연구)

  • Kim, Ki-Tae;Kim, Dong-Il
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.807-810
    • /
    • 2011
  • The sensor network technology for core technology of ubiquitous computing is in the spotlight recently, the research on sensor network is proceeding actively which is composed many different sensor node. USN(Ubiquitous Sensor Network) is the network that widely applies for life of human being. It works out to sense, storage, process, deliver every kind of appliances and environmental information from the stucktags and sensors. And it is possible to utilize to measure and monitor about the place of environmental pollution which is difficult for human to install. It's studied constantly since it be able to compose easily more subminiature, low-power, low-cost than previous one. And also it spotlights an important field of study, graft the green IT and IT of which the environment and IT unite stragically onto the Network. The problem for the air pollution in the office or the indoor except a specific working area is the continuously issue since the human beings have lived in the dwelling facilities. Measures for that problem are urgently needed. It's possible to solve for the freshair of outside with enough ventilation but that is the awkward situation to be managed by person. This study is the system engineering to management for indoor air condition under the sensor network. And research for efficiently manage an option.

  • PDF

Health and Environmental Risk Assessment of Pollutants in Pohang (포항지역 오염물질 보건.환경 위해성 평가 -미세먼지의 발생특성 및 농도분포를 중심으로-)

  • Jung, Jong-Hyeon;Choi, Won-Joon;Leem, Heon-Ho;Shon, Byung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.7
    • /
    • pp.2719-2726
    • /
    • 2010
  • The purpose of this study was to investigate the scientific basic grounds for the assessment of health and environmental diseases resulting from air pollutants in Pohang. For this study, we investigated pollutants, weather characteristics and concentration distribution of fine particles ($PM_10$) yearly and each season, using data from Air Quality Monitoring Stations. The properties of concentration distribution and seasonal fluctuation of $PM_10$ were studied qualitatively and quantitatively using CALPUFF, air dispersion model. The average concentration of $PM_10$ for each season was spring($75.7{\mu}g/m^3$)>summer($56.8{\mu}g/m^3$)>winter($53.6{\mu}g/m^3$)>fall( $52.7{\mu}g/m^3$). In the case of spring, high concentrations appear due to the Asian dust frequently occurring. The contributions of $PM_10$ classified by the types of pollution source in Pohang were point source 62%>mobile source 33%>area source 5%. An important point is that 97% of emissions were produced from the iron manufacture in steel industry. Therefore, it is necessary to control the emission sources of pollutants and to construct an observation system at Pohang steel industrial complex from now on. It’s time to control the risk factors for health and environmental disease to protect the health of resident in Pohang and its neighboring areas.

A Meta-analysis of Ambient Air Pollution in Relation to Daily Mortality in Seoul, $1991\sim1995$ (메타분석 방법을 적용한 서울시 대기오염과 조기사망의 상관성 연구 (1991년$\sim$1995년))

  • Dockery, Douglas W.;Kim, Chun-Bae;Jee, Sun-Ha;Chung, Yong;Lee, Jong-Tae
    • Journal of Preventive Medicine and Public Health
    • /
    • v.32 no.2
    • /
    • pp.177-182
    • /
    • 1999
  • Objectives: To reexamine the association between air pollution and daily mortality in Seoul, Korea using a method of meta-analysis with the data filed for 1991 through 1995. Methods: A separate Poisson regression analysis on each district within the metropolitan area of Seoul was conducted to regress daily death counts on levels of each ambient air pollutant, such as total suspended particulates (TSP), sulfur dioxide $(SO_2)$, and ozone $(O_3)$, controlling for variability in the weather condition. We calculated a weighted mean as a meta-analysis summary of the estimates and its standard error. Results: We found that the p value from each pollutant model to test the homogeneity assumption was small (p<0.01) because of the large disparity among district-specific estimates. Therefore, all results reported here were estimated from the random effect model. Using the weighted mean that we calculated, the mortality at a $100{\mu}g/m^3$ increment in a 3-day moving average of TSP levels was 1.034 (95% Cl 1.009-1.059). The mortality was estimated to increase 6% (95% Cl 3-10%) and 3% (95% Cl 0-6%) with each 50 ppb increase for 9-day moving average of SO2 and 1-hr maximum O3, respectively. Conclusions: Like most of air pollution epidemiologic studies, this meta-analysis cannot avoid fleeing from measurement misclassification since no personal measurement was taken. However, we can expect that a measurement bias be reduced in a district-specific estimate since a monitoring station is hefter representative cf air quality of the matched district. The similar results to those from the previous studios indicated existence of health effect of air pollution at current levels in many industrialized countries, including Korea.

  • PDF