• 제목/요약/키워드: air quality management

검색결과 664건 처리시간 0.057초

On the management methods for regional air quality improvement

  • Park, Chan Jin
    • 도시과학
    • /
    • 제6권2호
    • /
    • pp.1-13
    • /
    • 2017
  • The air quality management in regional viewpoint was investigated for the improvement of national air pollution with various standard air pollutants. The focal region in this research is north-eastern region in asia where the many developing industries are located in neighboring countries. The major concerns were the trends of air quality in recent years and the state of environmental technologies and policies of air quality in each countries. The regional air quality management for the improvement of air pollution and the effective programs were suggested for the effective air quality management.

  • PDF

위해성을 고려한 대기오염물질의 관리 방향 (Direction for the management of air pollutants based on health risk in Korea)

  • 김영주;김용표
    • 한국입자에어로졸학회지
    • /
    • 제13권2호
    • /
    • pp.43-52
    • /
    • 2017
  • Policy direction for the management of air quality in Korea has been on the reduction of the average concentrations of the criteria air pollutants such as sulfur dioxide and fine particles. However, recently, risk based management of air pollutants becomes an important issue. In this study, to develop an effective air quality management policy direction in Korea, (1) the fourth Multiple Air Toxics Exposure Study (MATES IV) carried out in the South Coast Air Quality Management District (SQAQMD) in the USA is reviewed and (2) the results are compared with in these in Seoul and (3) policy directions are suggested. It was found that (1) systematic integrated study comprising of measurement, modeling, emission inventory estimation, and risk assessment was essential to estimate the health risk of air pollutants reliably, (2) cancer risk of diesel particle was dominant over other air pollutants, and (3) health risk based emissions were different from amount based emissions. It was suggested that (1) reducing the exposure from hot spots might important to reduce health risk from air pollutants and (2) an integrated air quality management administration system is important for the efficient management of air pollution.

산업단지 대기질 관리, HAP인가 VOC인가\ulcorner (Air Quality Management in the Industrial Estate, HAP or VOC\ulcorner)

  • 김영성
    • 한국대기환경학회지
    • /
    • 제15권4호
    • /
    • pp.513-517
    • /
    • 1999
  • Problems of secondary pollution and hazardous pollutants have rapidly come to the front in our society during the past few years. More attention should be paid to monitoring and assessment in order to identify the nature of complicated problems, but our air-quality policy is hurriedly seeking for management strategies. A typical example is air quality management in the industrial estates such as those located in Yochon and Ulsan. Yochon Industrial Estate was designated as a special air-quality management area of volatile organic compounds(VOCs) in 1996. And VOCs in the air of Ulsan Industrial Estate has been specially controlled since 1997. In this paper, however, it is suggested that hazardous air pollutants(HAPs) rather than VOCs should have been managed in the industrial estates. History of studies on organic compounds in the air of the industrial estates is reviewed. A stepwise approach for air quality management in the industrial estates is recommended.

  • PDF

국내 실내공기질 관리정책의 변천 및 제어기술의 현황 (Management Policy and Control Technology for Indoor Air Quality in Korea)

  • 배귀남;지준호
    • 한국대기환경학회지
    • /
    • 제29권4호
    • /
    • pp.378-389
    • /
    • 2013
  • In Korea, studies on the indoor air quality have been conducted since mid of 1980s. The turning point occurred in 2003 by establishing the act of the indoor air quality management for public facilities. According to the law, the basic plan for indoor air quality management is prepared by government every five years, affecting greatly governmental policy and related academia and industries. Indoor air quality survey was mostly carried out among indoor air quality researches. After then, assessment of health effect and air cleaning technology were studied. Although various control technologies for particle, bioaerosol, odor, and hazardous chemicals have been applied to indoor environments, breakthrough technologies are needed to solve real problems facing at the applied environments. In the future, issue of indoor air quality is more interested and both management policy and control technology are key factors in order to realize comfort and healthy indoor environments.

소방청사 차고지 공기질 분석 및 유해물질 노출 관리 방안 (Analysis of Air Quality and the Management Plan for Exposure to Hazardous Substances in the Garage of a Fire Station)

  • 박제섭;한동훈
    • 한국산업보건학회지
    • /
    • 제30권4호
    • /
    • pp.394-404
    • /
    • 2020
  • Objectives: The aims of this study are to derive the characteristics of diesel exhaust gas emissions generated during vehicle checking in the garage of fire stations and of the related improvement plans for proper air quality management. Methods: The researcher measured changes in the air quality inside garages according to the operating conditions of the exhaust facility and before and after vehicle checking at three fire stations. Results: During the checking of fire engines, a large volume of hazardous substances exceeding management standards were generated, and improvement of the discharge facilities was required for proper air quality management. Conclusions: It is necessary to study the hazard evaluation of firefighters' exposure to exhaust gas, to operate exhaust gas ventilation facilities, and to prepare technical standards for proper indoor air quality management.

An Analysis about Recognition of Indoor Air Quality of Workers at Dental Clinics in Jeollanamdo Area

  • Choi, Mi-Suk
    • 한국컴퓨터정보학회논문지
    • /
    • 제23권11호
    • /
    • pp.137-142
    • /
    • 2018
  • The purpose of this study is to contribute to the improvement of indoor air quality management in dental clinic by investigating the level of indoor air quality recognition among dental clinic workers. The questionnaire survey was conducted for about 4 weeks from May 20 to June 20, 2018 in dental clinics located in Jeollanamdo area and 143 were used as the analysis data. The method of indoor air quality management in dental clinic was preferred to "natural ventilation" method and the number of natural ventilation was 1 to 2 times per day and the results of survey on indoor environment satisfaction showed that satisfaction level was lowest in noise and smell items. The types of subjective symptoms experienced by workers working at dental clinics are "cough", "eye burn", and "headache" and a survey on the degree of the relationship between subjective symptoms and indoor air quality showed that 94.4% (135) of respondents answered "very relevant" and "slightly related". As a result of multiple regression analysis, the variables affecting the indoor air quality satisfaction of the dental clinic staff were analyzed as the items such as lighting, noise, main work, number of patients, comparing indoor and outdoor air quality and among them, "comparing indoor and outdoor air quality" was analyzed as having a great influence. To improve the indoor air quality satisfaction of dental clinic worker adequate ventilation, designate the person responsible for the indoor air quality management and periodic measurement efforts will be necessary.

우리나라 유해대기오염물질의 관리 방향 (Direction for the management of hazardous air pollutants in Korea)

  • 여민주;김나경;김봉만;정창훈;홍지형;김용표
    • 한국입자에어로졸학회지
    • /
    • 제12권3호
    • /
    • pp.81-94
    • /
    • 2016
  • Managing hazardous air pollutants (HAPs) becomes an important issue with the amendment of the Clean Air Conservation Act in 2012. In this study, to develop an effective air quality management policy direction against the HAPs in Korea, (1) the HAPs control policies in the USA, United Kingdom, Japan, and the South Coast Air Quality Management District (SQAQMD) are reviewed, (2) the state of the art of the HAPs management in Korea are studied, and (3) policy directions are suggested. It was found that each country has its own policy priority and management directions. It was also found that the current HAPs management status is far behind to the countries compared in HAPs identification, emission inventory, monitoring, modeling, and risk management. Further policy directions are suggested.

사회복지시설 종사자의 실내공기질 관리에 대한 태도와 관련 요인에 관한 탐색적 연구 (An Exploratory Research on Social Workers' Attitude and Related Factors about Indoor Air Quality Management of Social Welfare Facilities)

  • 배진희
    • 한국콘텐츠학회논문지
    • /
    • 제17권5호
    • /
    • pp.273-284
    • /
    • 2017
  • 2015년에 발표된 실내공기질관리 기본계획은 민감계층을 고려하는 실내 환경보건 강화를 주요 추진 전략중 하나로 담고 있다. 사회복지생활시설은 장애인, 노인, 아동, 노숙인 등이 주 거주지로 삼으며 실내에서 머무는 시간이 매우 긴 공간이다. 그럼에도 불구하고 사회복지시설은 법정 실내공기질 관리 대상 기관이 아니다. 이에 본 연구는 사회복지생활시설 종사자들을 대상으로 실내공기질에 대한 태도와 관련 요인을 조사, 분석하였다. 실내공기질 관리의 필요성에 대해서 69.5%가 찬성하였고, 사회복지시설을 실내공기질 관리 대상 기관에 포함하는 것에 대해 80.9%가 찬성하였다. 응답자 중 90.8%가 본인이 종사하고 있는 시설의 실내공기질 분석을 받을 의향이 있다고 응답하였다. 사회복지시설의 실내공기질 관리 법정 기관화 찬성과 관련 있는 요인은 환경의식이었고, 본인이 종사하고 있는 실내공기질 분석 의사와 관련 있는 요인은 실내공기질 관리법 인지도였다. 분석결과를 기초로 사회복지시설 실내공기질 관리를 위한 환경부 다중이용시설등의 실내공기질 관리법 개정, 중앙 혹은 지방 정부의 비용부담, 사회복지시설 실내 공기질 관리에 대한 교육 및 연구의 필요성을 제안하였다.

대기오염측정망 정도관리의 문제점과 개선방향 (Problems and Improvements in the Quality Control of the Air Monitoring Network)

  • 김덕승;박정호
    • 한국환경과학회지
    • /
    • 제29권8호
    • /
    • pp.847-855
    • /
    • 2020
  • This study presented problems and improvements in the quality control of an air monitoring network, using Gyeongnam as an example. 1) The effective utilization rate of the air monitoring was 95%, which showed good management, but the maximum of 2% was indicated by zero or detection limit among measurement data. 2) In the equivalence evaluation of PM2.5, the slope and intercept satisfy the evaluation criteria; however, 1% of the PM2.5/PM10 ratios were outliers. 3) All air monitoring stations meet the quality control standards; however, the management status is added to the quality inspection, management system is unified and the related budget is expanded, and systematic commission management is required.

Assessing the Health Benefits of the Seoul Air Quality Management Plan Using BenMAP

  • Park, Jeong-Im;Bae, Hyun-Joo
    • 한국환경보건학회지
    • /
    • 제32권6호
    • /
    • pp.571-577
    • /
    • 2006
  • Health benefits from implementing air quality control measures were assessed using the Environmental Benefits Mapping and Analysis Program (BenMAP). BenMAP developed by US EPA is a GIS-based software tool that estimates the health impacts and associated economic values connected with changes in ambient air pollution. Once a set of BenMAP-required data was collected, the health benefits from implementing Seoul Air Quality Management Plan (SAQMP), an official AQ improvement plan for Seoul Metropolitan Area, was assessed using BenMAP. The PM10 concentrations assuming the SAQMP implemented successfully were predicted with the MM5 (Mesoscale Meteorological model version 5)/CMAQ (Community Multiscale Air Quality) model. A PM 10 exposure related premature mortality function was adopted trom a well-known epidemiology study. Economic valuation functions driven from benefit transfer methods were utilized. Through the SAQMP, PM10 concentrations were estimated to be lowered by $15{\mu}g/m^3\;to\;75{\mu}g/m^3$ depending on air quality modeling grids. 5,569 premature deaths (95% CI $3,264{\sim}7,809$ deaths) could be avoided in the Seoul Metropolitan Area. The economic value of the deaths avoided was estimated to $13.2 billion $(95%\;CI\;$890\;million{\sim}$28.2\;billion)$ using the benefit transfer value. BenMAP could be a useful tool for developing effective air quality improvement policy, enabling the policy makers to anticipate the effects of regulatory changes on people's health and the economy.