• Title/Summary/Keyword: air quality management

Search Result 664, Processing Time 0.031 seconds

On the management methods for regional air quality improvement

  • Park, Chan Jin
    • Journal of Urban Science
    • /
    • v.6 no.2
    • /
    • pp.1-13
    • /
    • 2017
  • The air quality management in regional viewpoint was investigated for the improvement of national air pollution with various standard air pollutants. The focal region in this research is north-eastern region in asia where the many developing industries are located in neighboring countries. The major concerns were the trends of air quality in recent years and the state of environmental technologies and policies of air quality in each countries. The regional air quality management for the improvement of air pollution and the effective programs were suggested for the effective air quality management.

  • PDF

Direction for the management of air pollutants based on health risk in Korea (위해성을 고려한 대기오염물질의 관리 방향)

  • Kim, Young Ju;Kim, Yong Pyo
    • Particle and aerosol research
    • /
    • v.13 no.2
    • /
    • pp.43-52
    • /
    • 2017
  • Policy direction for the management of air quality in Korea has been on the reduction of the average concentrations of the criteria air pollutants such as sulfur dioxide and fine particles. However, recently, risk based management of air pollutants becomes an important issue. In this study, to develop an effective air quality management policy direction in Korea, (1) the fourth Multiple Air Toxics Exposure Study (MATES IV) carried out in the South Coast Air Quality Management District (SQAQMD) in the USA is reviewed and (2) the results are compared with in these in Seoul and (3) policy directions are suggested. It was found that (1) systematic integrated study comprising of measurement, modeling, emission inventory estimation, and risk assessment was essential to estimate the health risk of air pollutants reliably, (2) cancer risk of diesel particle was dominant over other air pollutants, and (3) health risk based emissions were different from amount based emissions. It was suggested that (1) reducing the exposure from hot spots might important to reduce health risk from air pollutants and (2) an integrated air quality management administration system is important for the efficient management of air pollution.

Air Quality Management in the Industrial Estate, HAP or VOC\ulcorner (산업단지 대기질 관리, HAP인가 VOC인가\ulcorner)

  • 김영성
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.4
    • /
    • pp.513-517
    • /
    • 1999
  • Problems of secondary pollution and hazardous pollutants have rapidly come to the front in our society during the past few years. More attention should be paid to monitoring and assessment in order to identify the nature of complicated problems, but our air-quality policy is hurriedly seeking for management strategies. A typical example is air quality management in the industrial estates such as those located in Yochon and Ulsan. Yochon Industrial Estate was designated as a special air-quality management area of volatile organic compounds(VOCs) in 1996. And VOCs in the air of Ulsan Industrial Estate has been specially controlled since 1997. In this paper, however, it is suggested that hazardous air pollutants(HAPs) rather than VOCs should have been managed in the industrial estates. History of studies on organic compounds in the air of the industrial estates is reviewed. A stepwise approach for air quality management in the industrial estates is recommended.

  • PDF

Management Policy and Control Technology for Indoor Air Quality in Korea (국내 실내공기질 관리정책의 변천 및 제어기술의 현황)

  • Bae, Gwi-Nam;Ji, Jun-Ho
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.4
    • /
    • pp.378-389
    • /
    • 2013
  • In Korea, studies on the indoor air quality have been conducted since mid of 1980s. The turning point occurred in 2003 by establishing the act of the indoor air quality management for public facilities. According to the law, the basic plan for indoor air quality management is prepared by government every five years, affecting greatly governmental policy and related academia and industries. Indoor air quality survey was mostly carried out among indoor air quality researches. After then, assessment of health effect and air cleaning technology were studied. Although various control technologies for particle, bioaerosol, odor, and hazardous chemicals have been applied to indoor environments, breakthrough technologies are needed to solve real problems facing at the applied environments. In the future, issue of indoor air quality is more interested and both management policy and control technology are key factors in order to realize comfort and healthy indoor environments.

Analysis of Air Quality and the Management Plan for Exposure to Hazardous Substances in the Garage of a Fire Station (소방청사 차고지 공기질 분석 및 유해물질 노출 관리 방안)

  • Park, Je-Seop;Han, Dong-Hun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.4
    • /
    • pp.394-404
    • /
    • 2020
  • Objectives: The aims of this study are to derive the characteristics of diesel exhaust gas emissions generated during vehicle checking in the garage of fire stations and of the related improvement plans for proper air quality management. Methods: The researcher measured changes in the air quality inside garages according to the operating conditions of the exhaust facility and before and after vehicle checking at three fire stations. Results: During the checking of fire engines, a large volume of hazardous substances exceeding management standards were generated, and improvement of the discharge facilities was required for proper air quality management. Conclusions: It is necessary to study the hazard evaluation of firefighters' exposure to exhaust gas, to operate exhaust gas ventilation facilities, and to prepare technical standards for proper indoor air quality management.

An Analysis about Recognition of Indoor Air Quality of Workers at Dental Clinics in Jeollanamdo Area

  • Choi, Mi-Suk
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.11
    • /
    • pp.137-142
    • /
    • 2018
  • The purpose of this study is to contribute to the improvement of indoor air quality management in dental clinic by investigating the level of indoor air quality recognition among dental clinic workers. The questionnaire survey was conducted for about 4 weeks from May 20 to June 20, 2018 in dental clinics located in Jeollanamdo area and 143 were used as the analysis data. The method of indoor air quality management in dental clinic was preferred to "natural ventilation" method and the number of natural ventilation was 1 to 2 times per day and the results of survey on indoor environment satisfaction showed that satisfaction level was lowest in noise and smell items. The types of subjective symptoms experienced by workers working at dental clinics are "cough", "eye burn", and "headache" and a survey on the degree of the relationship between subjective symptoms and indoor air quality showed that 94.4% (135) of respondents answered "very relevant" and "slightly related". As a result of multiple regression analysis, the variables affecting the indoor air quality satisfaction of the dental clinic staff were analyzed as the items such as lighting, noise, main work, number of patients, comparing indoor and outdoor air quality and among them, "comparing indoor and outdoor air quality" was analyzed as having a great influence. To improve the indoor air quality satisfaction of dental clinic worker adequate ventilation, designate the person responsible for the indoor air quality management and periodic measurement efforts will be necessary.

Direction for the management of hazardous air pollutants in Korea (우리나라 유해대기오염물질의 관리 방향)

  • Yeo, Min Ju;Kim, Na Kyung;Kim, Bong Mann;Jung, Chang Hoon;Hong, Ji-hyung;Kim, Yong Pyo
    • Particle and aerosol research
    • /
    • v.12 no.3
    • /
    • pp.81-94
    • /
    • 2016
  • Managing hazardous air pollutants (HAPs) becomes an important issue with the amendment of the Clean Air Conservation Act in 2012. In this study, to develop an effective air quality management policy direction against the HAPs in Korea, (1) the HAPs control policies in the USA, United Kingdom, Japan, and the South Coast Air Quality Management District (SQAQMD) are reviewed, (2) the state of the art of the HAPs management in Korea are studied, and (3) policy directions are suggested. It was found that each country has its own policy priority and management directions. It was also found that the current HAPs management status is far behind to the countries compared in HAPs identification, emission inventory, monitoring, modeling, and risk management. Further policy directions are suggested.

An Exploratory Research on Social Workers' Attitude and Related Factors about Indoor Air Quality Management of Social Welfare Facilities (사회복지시설 종사자의 실내공기질 관리에 대한 태도와 관련 요인에 관한 탐색적 연구)

  • Bae, Jin-Hee
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.5
    • /
    • pp.273-284
    • /
    • 2017
  • As these days people spend most of time at inner space, indoor air quality affect human life seriously. Government manage indoor air quality of various facilities based on different laws. Government released that they would try to protect environment for vulnerable people such children and seniors from indoor air pollutants in 2015. But social welfare facilities are exception under current legal systems. Clients of social welfare residential facilities are the disables, the elderly, homeless and children and they usually stay inner space very long time. The purpose of this study is explore workers' attitude and related factors about indoor air quality management of social welfare facilities. 69.5% of respondents agree to government's indoor air quality management, 80.9% of respondents think social welfare facilities must be included in legal system for indoor air quality management. Environmental awareness and law awareness were related with attitude to indoor air quality management. Based on the results of the analysis, I propose the amendment of law on indoor air quality of the Ministry of Environment, cost burden of central or local government and the necessity of education and research on indoor air quality management in social welfare facilities.

Problems and Improvements in the Quality Control of the Air Monitoring Network (대기오염측정망 정도관리의 문제점과 개선방향)

  • Kim, Duck-Sung;Park, Jeong-Ho
    • Journal of Environmental Science International
    • /
    • v.29 no.8
    • /
    • pp.847-855
    • /
    • 2020
  • This study presented problems and improvements in the quality control of an air monitoring network, using Gyeongnam as an example. 1) The effective utilization rate of the air monitoring was 95%, which showed good management, but the maximum of 2% was indicated by zero or detection limit among measurement data. 2) In the equivalence evaluation of PM2.5, the slope and intercept satisfy the evaluation criteria; however, 1% of the PM2.5/PM10 ratios were outliers. 3) All air monitoring stations meet the quality control standards; however, the management status is added to the quality inspection, management system is unified and the related budget is expanded, and systematic commission management is required.

Assessing the Health Benefits of the Seoul Air Quality Management Plan Using BenMAP

  • Park, Jeong-Im;Bae, Hyun-Joo
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.6
    • /
    • pp.571-577
    • /
    • 2006
  • Health benefits from implementing air quality control measures were assessed using the Environmental Benefits Mapping and Analysis Program (BenMAP). BenMAP developed by US EPA is a GIS-based software tool that estimates the health impacts and associated economic values connected with changes in ambient air pollution. Once a set of BenMAP-required data was collected, the health benefits from implementing Seoul Air Quality Management Plan (SAQMP), an official AQ improvement plan for Seoul Metropolitan Area, was assessed using BenMAP. The PM10 concentrations assuming the SAQMP implemented successfully were predicted with the MM5 (Mesoscale Meteorological model version 5)/CMAQ (Community Multiscale Air Quality) model. A PM 10 exposure related premature mortality function was adopted trom a well-known epidemiology study. Economic valuation functions driven from benefit transfer methods were utilized. Through the SAQMP, PM10 concentrations were estimated to be lowered by $15{\mu}g/m^3\;to\;75{\mu}g/m^3$ depending on air quality modeling grids. 5,569 premature deaths (95% CI $3,264{\sim}7,809$ deaths) could be avoided in the Seoul Metropolitan Area. The economic value of the deaths avoided was estimated to $13.2 billion $(95%\;CI\;$890\;million{\sim}$28.2\;billion)$ using the benefit transfer value. BenMAP could be a useful tool for developing effective air quality improvement policy, enabling the policy makers to anticipate the effects of regulatory changes on people's health and the economy.