• Title/Summary/Keyword: air quality evaluation

Search Result 607, Processing Time 0.035 seconds

A Study on the Evaluation of Indoor Air Environment in Super High-Rise Dwelling House (都市 超高層 住居建築의 室內空氣環境의 評價에 관한 硏究)

  • Park, Mi-Jin
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.4
    • /
    • pp.119-125
    • /
    • 2002
  • The concept of dwelling space is tend to be changed not only to have reasonable mobility but also to have high quality of indoor air with psychologicaa satisfaction and comfortable. Moreover, recent constructed buildings have a big problem because of exhausted pollution gas and particles from building materials. More serious problem occurs from its high air tightness reducing the ventilation for saving the energy and superior adiabatic insulators to have high heat efficiency. Indoor air quality in super high-rise dwelling house was investigated by measuring pollutants such as $CO_2,=;CO,\;MO_2,\;R_n,\;TSP,\;PM_{10}$, HCHO, Offensive ordor. Subjective evaluation of residential environment is processed for the inhabitants who live in research space by testing environmental load in accordance with environment morphology, exterior environmental factor and post occupancy correlation and influence of attention.

Assessment of Air Quality Impact Associated with Improving Atmospheric Emission Inventories of Mobile and Biogenic Sources

  • Shin, Tae-joo
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.4 no.1
    • /
    • pp.11-23
    • /
    • 2000
  • Photochemical air quality models are essential tools in predicting future air quality and assessing air pollution control strategies. To evaluate air quality using a photochemical air quality model, emission inventories are important inputs to these models. Since most emission inventories are provided at a county-level, these emission inventories need to be geographically allocated to the computational grid cells of the model prior to running the model. The conventional method for the spatial allocation of these emissions uses "spatial surrogate indicators", such as population for mobile source emissions and county area for biogenic source emissions. In order to examine the applicability of such approximations, more detailed spatial surrogate indicators were developed using Geographic Information System(GIS) tools to improve the spatial allocation of mobile and boigenic source emissions, The proposed spatial surrogate indicators appear to be more appropriate than conventional spatial surrogate indicators in allocating mobile and biogenic source emissions. However, they did not provide a substantial improvement in predicting ground-level ozone(O3) concentrations. As for the carbon monoxide(CO) concentration predictions, certain differences between the conventional and new spatial allocation methods were found, yet a detailed model performance evaluation was prevented due to a lack of sufficient observed data. The use of the developed spatial surrogate indicators led to higher O3 and CO concentration estimates in the biogenic source emission allocation than in the mobile source emission allocation.llocation.

  • PDF

Evaluation of Air Quality Inside Passenger Car with Operating Air Quality System (공기질 조절장치 작동 승용차 내부의 공기질 평가)

  • 조완근;박건호
    • Journal of Environmental Science International
    • /
    • v.7 no.5
    • /
    • pp.573-580
    • /
    • 1998
  • This study examined the carbon dioxide ($CO_2$) pollution inside vehicles under low ventilation condition and evaluated the Air Quality System (AQS) for in-vehicle air quality using two techniques. The low ventilation condition is not recommended in order to keep oxygen-rich condition inside vehicles. Under the low ventilation condition, the in-vehicle $CO_2$ concentrations exceeded 1,000 ppm, the air qualify guidelines in the United States, Western Europe, and Japan, indicating more oxygen deficiency inside vehicles. On the contrary, with the AQS-on condition, the in-vehicle $CO_2$ concentrations were less than 1,000 ppm fer most of the driving time, indicating that the AQS could solve the problem of $CO_2$ accumulation inside vehicles under the low ventilation condition. The AQS test conducted by comparing carbon monoxide (CO) and volatile organic compound (VOC) concentrations inside two vehicles indicated that the AQS effectively decreased the in-vehicle concentrations by 21 to 36%, as compared to medium ventilation condition with the windows closed, the vent opened, and air conditioning on. In addition, The AQS test conducted by comparing the interior and exterior concentrations indicated that the AQS effectively decreased the in-vehicle concentrations by 18 to 31%, as compared to medium ventilation condition.

  • PDF

A Finish Material Management Process for Indoor Air Quality -Focused on Apartment Buildings- (실내 공기질을 고려한 마감자재 선정 프로세스 연구 -공동주택을 중심으로-)

  • Kwon, Gi-Deoc;Lee, Dong-Hoon;Lee, Sung-Ho;Zheng, Qi;Kim, Sun-Kuk
    • KIEAE Journal
    • /
    • v.10 no.6
    • /
    • pp.123-130
    • /
    • 2010
  • Indoor air quality has attracted great attention in recent years and thus the importance of managing finishing materials in terms of pollutant source control is being emphasized. Managing the finishing material at the design stage maximizes the efficiency of IAQ control at the following construction stage. However, there are insufficient investigations on the application of a specific finishing material management process, a database management system or a finishing material management process network. As a result, the main purposes of this study comprise comprehensive evaluation of IAQ performance from the selected finishing materials and auxiliary materials, application of the material management system basing on the types and characteristics of toxic substances generated from the indoor finishing materials, investigation of IAQ evaluation standard, and the overall IAQ evaluation method for the design parts. The result of this study will be the basic data to construct DBMS for management of finishing materials with respect to IAQ.

A Preliminary Study on the Current Status and Health Effects of PM2.5 for Evaluating the Act on Air Quality Management Regions in Jeollabuk-do Province (대기관리권역법 시행효과 평가를 위한 전북지역 초미세먼지 현황 및 건강영향 사전연구)

  • Chang-Jin Ma;Nam-Jeong Jang;Gong-Unn Kang
    • Journal of Environmental Health Sciences
    • /
    • v.50 no.4
    • /
    • pp.282-290
    • /
    • 2024
  • Background: In order to evaluate the national effort to improve air quality through the Act on Air Quality Management Regions, an investigation of the current status of air quality in respective regions and the health impact of air pollution should be undertaken. Objectives: This study is a preliminary study on the status of PM2.5 in the central region of South Korea and its health effects. It can be applied to the evaluation of the effectiveness of the Act on Air Quality Management Regions. Methods: Time series variation of PM2.5 concentrations in the air quality management region (hereafter referred to as AQMR) and in the non-AQMR area in the central region of South Korea were created. Odds ratios (OR) were calculated based on the survey results of whether the residents of Jeollabuk-do were feeling anxiety caused by air pollution by sex, region, and regional characteristics. Relative risk (RR) values of lung cancer deaths in each city in the AQMR for the central region of South Korea were calculated. Results: During the period from Dec. 2018 to Dec. 2021, the average concentration of PM2.5 was higher in the AQMR at 26.0 ㎍/m3 compared to 19.5 ㎍/m3 in the non-AQMR. The odds ratio (OR) calculated using data from the Jeonbuk Research Institute (2020) suggested that women were more uncomfortable or anxious about their lives due to air pollutants than were men. The OR evaluation results also showed that in terms of PM2.5 sensitivity, residents in the non-AQMR were relatively more sensitive than those in the AQMR. The relative risk (RR) was calculated to evaluate the relationship between health hazards (PM2.5) and diseases (lung cancer). As a result, for super-aged people over 80 years old, compared to the non-AQMR (Muju-gun and Jangsu-gun), the residents in the AQMR (Jeonju, Gunsan, and Iksan) have about twice the relative risk of lung cancer. Conclusions: It is necessary to make efforts to improve residents' health and extend their healthy lives through efforts to reduce air pollutants such as PM2.5 in areas specially selected as an AQMR.

Post Occupancy Evaluation for Office Building with An Underfloor Air Distribution System (바닥공조 시스템이 적용된 사무공간의 거주후 성능평가)

  • Yoon, Seong-Hoon;Jang, Hyang-In;Jung, Hae-Kwon;Choi, Sun-Kyu;Yu, Ki-Hyung
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.6
    • /
    • pp.78-85
    • /
    • 2011
  • In this study, an underfloor air distribution(UFAD) system installed on the S. office building was evaluated for its indoor environmental quality performance. Field measurement and survey were conducted for the overall POE(Post Occupied Evaluation). PMV(including temperature, humidity, air velocity and globe temperature) and several environmental components were measured while thermal comfort, thermal sensation, acoustical environment and others. were investigated through survey. Except for the direct upper part of the air supply diffuser on the floor, the indoor velocity was less than 0.25m/s, which has been suggested by ASHRAES tandard 55 as the limit for thermal comfort. MRT of the perimeter zone of the room showed a higher value than that in the interior because of the introduced solar radiation through the building envelope. PMV was generally maintained in the range of thermal comfort (from -0.5 to +0.5), though it weighted to the warm side. It was reported to have 61% positive response on thermal comfort and 55% on neutral thermal sensation. The results of each survey item showed some gender-based differences. Specifically, female respondents had higher degree of dissatisfaction with indoor air cleanness and acoustical privacy. The working surface showed more than 400 lux and the equivalent noise level showed less than 50 dB(A). In conclusion, the results of the measurement and survey showed good agreement. Indoor environmental quality of the subject office room where the UFAD system was installed showed an overall excellent performance.

Evaluation of Air Pollution Monitoring Networks in Seoul Metropolitan Area using Multivariate Analysis (다변량분석법을 활용한 수도권지역의 대기오염측정망 평가)

  • Choi, Im-Jo;Jo, Wan-Keun;Sin, Seung-Ho
    • Journal of Environmental Science International
    • /
    • v.25 no.5
    • /
    • pp.673-681
    • /
    • 2016
  • The adequacy of urban air quality monitoring networks in the largest metropolitan city, Seoul was evaluated using multivariate analysis for $SO_2$, $NO_2$, CO, PM10, and $O_3$. Through cluster analysis for 5 air pollutants concentrations, existing monitoring stations are seen to be clustered mostly by geographical locations of the eight zones in Seoul. And the stations included in the same cluster are redundantly monitoring air pollutants exhibiting similar atmospheric behavior, thus it can be seen that they are being operated inefficiently. Because monitoring stations groups representing redudancy were different depending on measurement items and several pollutants are being measured at the same time in each air monitoring station, it is seemed to be not easy to integrate or transmigrate stations. But it may be proposed as follows : the redundant stations can be integrated or transmigrated based on ozone of which measures are increasing in recent years and alternatively the remaining pollutants other than the pollutant exhibiting similar atmospheric behavior with nearby station's can be measured. So it is considered to be able to operate air quality monitoring networks effectively and economically in order to improve air quality.

A Study on the Measurement and Evaluation of lndoor Air Quality in School (학교 건축물의 실내공기질 측정 및 평가에 관한 연구)

  • Kim, Tae-Woo;Kim, Hyun-Tae;Hong, Won-Hwa
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2005.11a
    • /
    • pp.307-310
    • /
    • 2005
  • In recent years, our society is confronted with many environmental problems. Among them, Especially, Sick House Syndrome is brought into relief as a society's issue and the people's concern of Indoor Air Quality is also increased. Nowadays, about 20percent of korean children is suffered from allergic respiratory diseases such as asthma or rhinitis. From student's physical and mental point of view, indoor environmental condition of school is very important and must be kept by strict regulation Therefore, the aim of this thesis is focused on the measurement and analysis of indoor air quality of classroom.

  • PDF