• Title/Summary/Keyword: air oxidation

Search Result 952, Processing Time 0.025 seconds

Effect of Tillage Depths on Methane Emission and Rice Yield in Paddy Soil during Rice Cultivation (논토양에서 경운방법이 메탄발생과 쌀수량에 미치는 영향)

  • Cho, Hyeoun-Suk;Seo, Myung-Chul;Park, Tea-Sun;Kang, Hang-Won
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.60 no.2
    • /
    • pp.167-173
    • /
    • 2015
  • Green manure crops are organic materials that can supply organic matter and substitute chemical fertilizer, yet emit methane while being decomposed. Therefore, we experimented with different kinds of Green manure crops and tillage depth in order to decrease the amount of methane emitted when utilizing Green manure crops in paddy soil. The amount of methane emitted during the cultivation period of rice started to increase after transplanting and peaked at 63, and 74 days after transplanting, than decreased to almost none starting from 106 days. According to the kind of Green manure crop, it was highest in barley, then hairy vetch and chemical fertilizer. Depending on the tillage depth, the amount of methane emitted decreased by 22.5% in chemical fertilizer, 12.4% in hairy vetch and 11.7% in barley in 20cm tillage compared to 10cm tillage. The air temperature of methane test period was $30{\sim}40^{\circ}C$, and the soil temperature was more than about $2{\sim}10^{\circ}C$ lower than the air temperature. Due to the irrigation started before transplanting, the oxidation-reduction potential (Eh) of soil was rapidly reduced, and showed negative (-) values. Eh values mostly kept the range of -300~-500 mV during rice cultivation. It rapidly increased 106 days after transplanting. Rice yield the highest in hairy vetch and did not show differences according to tillage depth. Methane emission could be effectively reduced if the paddy soil was tilled by 20 cm during the application of hairy vetch.

Thermal and Mechanical Evaluation of Environmental Barrier Coatings for SiCf-SiC Composites (SiCf-SiC 복합재료의 내환경 코팅 및 열, 기계적 내구성 평가)

  • Chae, Yeon-Hwa;Moon, Heung Soo;Kim, Seyoung;Woo, Sang Kuk;Park, Ji-Yeon;Lee, Kee Sung
    • Composites Research
    • /
    • v.30 no.2
    • /
    • pp.84-93
    • /
    • 2017
  • This study investigates thermal and mechanical characterization of environmental barrier coating on the $SiC_f-SiC$ composites. The spherical environmental barrier coating (EBC) powders are prepared using a spray drying process for flowing easily during coating process. The powders consisting of mullite and 12 wt% of Ytterbium silicate are air plasma sprayed on the Si bondcoat on the LSI SiC fiber reinforced SiC composite substrate for protecting the composites from oxidation and water vapor reaction. We vary the process parameter of spray distance during air plasma spray of powders, 100, 120 and 140 mm. After that, we performed the thermal durability tests by thermal annealing test at $1100^{\circ}C$ for 100hr and thermal shock test from $1200^{\circ}C$ for 3000 cycles. As a result, the interface delamination of EBC never occur during thermal durability tests while stable cracks are prominent on the coating layer. The crack density and crack length depend on the spray distance during coating. The post indentation test indicates thermal tests influence on the indentation load-displacement mechanical behavior.

Development of a Gliding Arc Plasma Reforming System to Produce Hydrogen Form Biogas (바이오가스 개질을 위한 글라이딩 아크 플라즈마 개질 시스템 개발)

  • Kim, Seong Cheon;Yang, Yoon Cheol;Chun, Young Nam
    • Applied Chemistry for Engineering
    • /
    • v.20 no.4
    • /
    • pp.423-429
    • /
    • 2009
  • The purpose of this study is to investigate the optimal condition for the hydrogen-rich gas production and the CO removal by reforming of gliding arc plasma reforming system using biogas. The parametric screening studies were carried out according to changes of steam feed amount, catalyst bed temperature in water gas reactor and catalyst bed temperature, input air flow rate in preferential oxidation reactor. The standard condition is as follows. The steam/carbon ratio, catalyst bed temperature, total gas flow rate, input electric power and biogas composition rate ($CH_4$ : $CO_2$) were fixed 3, $700^{\circ}C$, 16 L/min, 2.4 kW and 6 : 4, respectively. The results are as follow, HTS optimum operating conditions were S/C ratio of 3 and reactor temperature of $500^{\circ}C$. LTS were S/C ratio of 2.9 and temperature of $300^{\circ}C$. Also, PROX I optimum conditions were input air flow rate of 300 mL/min and reactor temperature of $190^{\circ}C$. PROX II were 200 mL/min and $190^{\circ}C$ respectively. After having passed through each reactor, the results were as follows: 55% of $H_{2}$ yield, 0% of CO selectivity, 99% of $CH_4$ conversion rate, 27% of $CO_2$ conversion rate, respectively.

Reduction of Hexavalent Chromium on PVC Filters (혜산산업보건학술상 수상논문 - PVC 여과지에 채취된 6가 크롬의 환원)

  • Sin, Yong-Cheol
    • 월간산업보건
    • /
    • s.356
    • /
    • pp.16-25
    • /
    • 2017
  • Chromium exists at various valences, including elemental, trivalent, and hexavalent chromium, and undergoes reduction-oxidation reactions in the environment. Since hexavalent chromium is known as a human carcinogen, it is most important to evaluate the oxidationreduction characteristics of the hexavalent chromium species. Although hexavalent chromium can be reduced to trivalent state, the detailed information on this in workplace environments is limited. The purpose of this study was to investigate hexavalent chromium reduction in time in various conditions. A pilot chrome plating operation was prepared and operated in a laboratory for this study. There was evidence that the hexavalent chromium was reduced by time after mist generation. The percentage ratio (with 95% confidence intervals in parentheses) of hexavalent chromium to total chromium was almost 100% (99.1 ; 102.3) immediately after mist generation, and was reduced to 87.4% (84.8 ; 89.9) at 1 hour and 81.0% (78.3 ; 83.5) at 2 hours, respectively. Another test indicated that hexavalent chromium collected on PVC filters was also reduced by time after sampling. Hexavalent chromium was reduced to 90.8% (88.2 ; 93.3) at 2 hours after sampling. It also was found that hexavalent chromium was reduced during storage in air. It is recommended that air samples of hexavalent chromium be protected against reduction during storage.

  • PDF

Kinetics of Seed Growth of α-Ferric Oxyhydroxide (α-Ferric oxyhydroxide 입자의 핵성장 반응에 관한 연구)

  • Seul, Soo-Duk;Shin, Dong-Ock
    • Applied Chemistry for Engineering
    • /
    • v.8 no.4
    • /
    • pp.602-609
    • /
    • 1997
  • The seed formation and growth of $\alpha$-ferric oxyhydroxide with aerial oxidative precipitation from aqueous solution of ferrous sulfate with KOH, NaOH, $Na_2CO_3$ and $K_2CO_3$ as precipitants have been studied by free pH drift experiment. It has been shown that all precipitants give same particle formation and growth path, and average particle length from KOH and NaOH as precipitants was about 1.5 times shorter than that of $K_2CO_3$ and $Na_2CO_3$. When initial mole ratio, $R_o=[Fe^{2+}]_o/[OH^-]_o$ of KOH was decreased the particle was grown oxyhydroxide seed growth from aqueous solution of ferrous sulfate with KOH has been studied. The influence of the air flow rate, reaction temperature and initial mole ratio, $R_o=[Fe^{2+}]_o/[OH^-]_o$, on the kinetics of seed growth are investigated by static pH experiment. The oxidation rate of seed growth increased with increase in the air low rate, reaction temperature and initial mole patio. The activation energy of seed growth is 16.16 KJ/mol and the rate equation of seed growth can be written as follows: $-\frac{d[Fe^{2+}]}{dt}=1.46{\times}10^4[P_{o2}]^{0.66}[OH^-]^{2.19}exp(-\frac{16.16}{dt})$.

  • PDF

Effect of Drinking Water Treatment by DOF(Dissolved Ozone Flotation) System (DOF 공정에 의한 정수처리 효과)

  • Lee, Byoung-Ho;Song, Won-Chul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.7
    • /
    • pp.743-750
    • /
    • 2008
  • In water treatment plant the Dissolved Ozone Flotation(DOF) System may be employed because this system has various abilities, such that it can remove SS using microbubbles, and it can exert strong oxidation power in removing taste and odor, color, and microbial agents. In order to investigate effectiveness of the DOF system in water treatment, removal characteristics of various water quality parameters were observed depending on the different levels of ozone concentrations. Removal efficiencies of water quality parameters in DOF system were compared with those in DAF(Dissolved Air Flotation) system and in CGS(Conventional Gravity Settling) system. Optimum ozone dose obtained in the pilot experiments was 2.7 mg/L. With increasing ozone dose higher than 2.7 mg/L, removal rates of turbidity, KMnO$_4$ consumption, UV$_{254}$ absorbance, and TOC were reversely lowered. High concentration of ozone dissociate organic matter in water, so that increasing dissolved organic level in effluent. Removal rates of water quality parameters at optimum ozone dose were obtained, such that removal rates of turbidity, KMnO$_4$ consumption, TOC, and UV$_{254}$ asorbance were 88.9%, 62.9%, 47%, and 77.3% respectively. Removal rate of THMFP was 51.6%. For all the parameters listed above, the DOF system was more effective than the DAF system or the CGS system. It is found that the DOF system may be used in advanced water treatment not only because the DOF system is more efficient in removing water quality parameters than the existing systems, but because the DOF system is also required smaller area than the CGS system for the treatment plant.

A Study on the H2 Oxidation over Pt/TiO2, SO2 Poisoning and Regeneration (Pt/TiO2의 HS 산화반응 및 SO2 피독과 재생 방안 연구)

  • Lee, Dong Yoon;Kim, Sung Su
    • Applied Chemistry for Engineering
    • /
    • v.30 no.6
    • /
    • pp.731-736
    • /
    • 2019
  • In this article, Pt/TiO2 was manufactured in the form of powder and honeycomb, and the influence of SO2, which is a poisonous substance to catalyst, and regeneration method were investigated. The catalytic activity of Pt/TiO2 before and after the exposure to SO2 was also compared. The initial activity of Pt/TiO2 was proportional to the injected H2 concentration (1~5%). And the optimum temperature of the catalyst and conversion rate of H2 were 183 ℃ and 95%, respectively. It was confirmed that when exposing 2,800 ppm of SO2 to the powder and honeycomb Pt/TiO2, the performance of catalyst was not measurable and also 0.69% sulfur (S) remained on the catalyst surface. As a result of the cleaning and heat treatment for the poisoning catalyst, the activity of the powder catalyst exhibited a conversion rate of H2 greater than 96%. Whereas, the honeycomb catalyst showed a conversion rate of H2 greater than 95% when it was regenerated through the heat treatment of H2 or air atmosphere.

Field Applicability of Low Temperature Thermal Desorption Equipment through Environmental Impact Analysis of Remediated Soil and Exhaust Gas (정화토양 및 배출가스의 환경적 특성 분석을 통한 저온열탈착장치의 현장 적용성 평가)

  • Oh, Cham-Teut;Yi, Yong-Min;Kim, Young-Soung;Jeon, Woo-Jin;Park, Gwang-Jin;Kim, Chi-Kyung;Sung, Ki-June;Chang, Yoon-Young;Kim, Guk-Jin
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.3
    • /
    • pp.76-85
    • /
    • 2012
  • Geochemical and ecological properties of remediated soil and gas exhausted from a low-temperature thermal desorption (LTTD) process were analyzed to assess the environmental impact of LTTD treatment. Soil characteristics were examined with regard to the chemical (EC, CEC, and organic matter) and the ecological (dehydrogenase activity, germination rate of Brassica juncea, and growth of Eisenia andrei) properties. The exhaust gases were analyzed based on the Air Quality Act in Korea as well as volatile organic compounds (VOCs) and mixed odor. Level of organic Organic matter of the soil treated by LTTD process was slightly decreased compared to that of the original soil because the heating temperature ($200^{\circ}C$) and retention time (less than 15 minutes) were neither high nor long enough for the oxidation of organic matter. The LTTD process results in reducing TPH of the contaminated soil from $5,133{\pm}508$ mg/kg to $272{\pm}107$ mg/kg while preserving soil properties. Analysis results of the exhaust gases from the LTTD process satisfied discharge standard of Air Quality Law in Korea. Concentration of VOCs including acetaldehyde, propionaldehyde, butyraldehyde and valeraldehyde in circulation gas volatilized from contaminated soil were effectively reduced in the regenerative thermal oxidizer and all satisfied the legal standards. Showing ecologically improved properties of contaminated soil after LTTD process and environmentally tolerable impact of the exhaust gas, LTTD treatment of TPH-contaminated soil is an environmentally acceptable technology.

Measurement of Formaldehyde in the Atmosphere using a Dual-channel Glass Coil Sampler (이중 채널 유리코일 샘플러를 이용한 대기 중 포름알데하이드 측정)

  • Park Seung-Shik;Hong Sang-Bum;Lee Jai-Hoon;Cho Sung-Yong;Kim Seung-Jai
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.2
    • /
    • pp.259-266
    • /
    • 2006
  • A dual-channel glass coil sampling technique was used to measure hourly formaldehyde concentration in the ambient air. The dual-channel coil sampling assembly consists of three parts; an all-pyrex 28-turn coil made of 0.2-cm internal diameter glass tubing for gas-liquid contact and scrubbing of soluble gases, an inlet section upstream of the coil for introducing sample air and scrubbing solution, and a widened glass section downstream of the coil for gas-liquid separation. The scrubbing solution used was a dilute aqueous DNPH (dinitrophenylhydrazine) solution. Hourly concentration of formaldehyde was determined at a Gwangju semi-urban site during two intensive studies between September and October using the dual channel glass-coil/DNPH sampling technique and HPLC (High Performance Liquid Chromatography) analysis. The mean concentration was 1.7($0.4{\sim}4.7$) and 3.0($0.5{\sim}19.1$) ppbv for the September and October intensives, respectively, which are considerably low, compared to those measured in polluted urban areas around the world including several urban areas of Korea. The diurnal variation showed significant increase of formaldehyde in the daytime suggesting the dominance of formation of formaldehyde due to photochemical oxidation of methane and other hydrocarbons. An increase in the formaldehyde sometimes in the night might be due to an increase in primary source, i.e. traffic emissions. It was also found that rapid increase in formaldehyde levels from 3.0 to 19.1 ppbv in the afternoon on October 20 was due to plumes from burning of agricultural wastes such as rice straw and stubble. It is expected from the measurement data that the constructed dual-channel glass coil sampling system can be utilized for measuring atmospheric concentration of the formaldehyde with high time resolution.

Characteristics of Carbonaceous Particles Derived from Coal-fired Power Plant and Their Reduction (석탄 화력발전소에서 발생하는 미연분의 특성분석 및 저감방법)

  • Park, Ho-Young;Kim, Young-Ju;Yu, Geun-Sil;Kim, Chun-Kun;Kim, Dong-Hun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.10
    • /
    • pp.1065-1073
    • /
    • 2006
  • The unturned carbon in fly ash, recently occurred in the coal-fired Yong Hung power station, caused some problems in ash utilization and boiler efficiency. This paper describes the analysis of unburned carbon and six coals, some tests performed at Yong Hung Boiler, and the results of combustion modification for the reduction of unburned carbon in fly ash. From the physical and chemical analysis of unburned carbon in fly ash, most particles were turned out to be hollow cenosphere and agglomerated soot particles. The sooting potential from six coals used in the plant were investigated with CPD(Chemical Percolation Devolatilization) model. The results showed that the higher potential was presented to Peabody, Arthur, Shenhua coals rather than other coals. It was necessary to measure the coal flow rates at each coal feeding pipe for four burner levels since they affect the extent of mixing of soot with oxidant, in turn, the oxidation rate of soot particles. The unbalance in coal flow rate was found in several coal pipes. We successfully reduced unturned carbon in ash by increasing the excess air and changing the SOFA's yaw angle.